• Title/Summary/Keyword: Partial Test

Search Result 1,769, Processing Time 0.032 seconds

Innovative Dietary Intervention Answers to Baby Colic

  • Xinias, Ioannis;Analitis, A.;Mavroudi, Antigoni;Roilides, Ioannis;Lykogeorgou, Maria;Delivoria, Varvara;Milingos, Vasilis;Mylonopoulou, Mayra;Vandenplas, Yvan
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.20 no.2
    • /
    • pp.100-106
    • /
    • 2017
  • Purpose: The purpose of this paper is to evaluate the efficacy of a lactose- reduced synbiotic partial whey hydrolysate in formula fed infants presenting with colic and the impact of this dietary intervention in mean crying time and quality of life. Methods: Forty infants with infantile colic were treated during one month with parental reassurance and the intervention formula (partial whey hydrolysate, reduced lactose, Bifidobacterium lactis BB12 and galacto-oligosaccharides) and were compared to a control group of 20 infants with infantile colic treated with parental reassurance and a standard infant formula. Parents completed a quality of life (QoL) questionnaire assessing the burden of infantile colic. Wilcoxon test, t-test and Mann-Whitney test were used to compare QoL scores before and after intervention as well as between the intervention and control group. Results: At inclusion, duration of crying did not differ between both groups. Crying duration decreased with 2.7 hours (from 3.2 to 0.5 hours) in the intervention group while duration of crying decreased only with 1.2 hours in the control group (p<0.001). Stool composition became looser in the intervention group, but defecation frequency did not change. The median scores of the QoL questionnaire improved significantly in the intervention group for all parameters. In the control group, parameters improved significantly also but not for the parent-child and social interaction. The score changes were significantly greater in the intervention than in the control group. Conclusion: The intervention formula (partial whey hydrolysate, synbiotic, reduced lactose) significantly reduced the duration of crying and improved QoL of the parents and infants.

A Study on the Effects of Perceived Parenting Attitudes on Regulatory Focus Among College Students: Mediating the Effects of Ego-Resiliency (대학생이 지각한 부모양육태도가 조절초점에 미치는 영향: 자아탄력성의 매개효과)

  • Cho, Gyeong Suk
    • Korean Journal of Child Studies
    • /
    • v.37 no.5
    • /
    • pp.19-31
    • /
    • 2016
  • Objective: The purpose of this study was to test the mediating effects of ego-resilience on relationship between perceived parenting attitudes and regulatory focus among college students. Methods: In this study, 256 college students were surveyed. The collected data were put through correlation analysis using PASW Statistics 18.0. In addition, 3-stage multiple regression analyses and the Sobel test were used to test any mediating effects. Results: The findings show that the diversity of concerns and interests, emotion control, and positive future orientation, the subfactors of ego-resiliency, all have partial mediating effects on the relationship between father's care and promotion focus. Only positive future orientation had partial mediating effects on the relationship between mother's care and promotion focus. Conclusion: Father's care turned out to be an independent variable to explain better the mediating effects of ego-resiliency on relations between parenting attitudes and regulatory focus, which implies the influence and importance of father's care on college students.

On-line Condition Monitoring for Electric Equipments (전력 설비 시스템의 온라인 감시)

  • Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04c
    • /
    • pp.103-105
    • /
    • 2008
  • In, this paper, we consider the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PO) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PO testing delivers the best possible information about defects and enables the classification of the risk. Because alternating voltage (AC) is the most important test voltage, the AC generation on site is considered. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PO measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers - is described.

  • PDF

HPF Application Test for PD Detection of XLPE Power Cable (XLPE 전력케이블의 부분방전 검출을 위한 HPF 적용 시험)

  • Kim, Jung-Yoon;Yang, Jong-Kyung;Park, Noh-Joon;Choi, Yong-Sung;Park, Dae-Hee;Lee, Yong-Sung
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.4
    • /
    • pp.161-165
    • /
    • 2006
  • In this paper, we developed HPF (high pass filter) consists of lumped LC components to decrease the noises that are detected in PD (partial discharge) measuring test, and adapted it to field test. We tested it under laboratory circumstances like the fields, and measured the phase change properties of detected signal in UHF sensor with Lemke Probe and oscilloscope (TDS-3054, Tektronix). As a result, we obtained available data showing the decrease of noises in the experiments with the developed HPF from the joint box of 22.9kV distribution line. The result can be adapted to prevent the degeneration of the XLPE power cable, and to observe and diagnosis the underground power transmission cable at the ultra-high voltage.

Filter Test for Partial Discharge Detection of Underground Distribution Cables (지중배전케이블의 PD 검출용 필터 시험 연구)

  • Lee, Yong-Sung;Kim, Jung-Yoon;Lee, Kwan-Woo;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.215-216
    • /
    • 2005
  • To decrease and remove of much noises that is detected in PD (partial discharge) measuring test. we forced on detection of those. We made W-LC filter for measuring PD. which adapted that to field test. We tested after design laboratory circumstances like field line. and then the phase change properties of detected signal in UHF sensor were measured by Lemke Probe and oscilloscope (TDS-3054. Tektronix). Eventually we checked decrement of noises from experimental result. Also from experimental result at the joint box of 22.9[kV] distribution line. we obtained reasonable data which enable noises to decrease. Hereafter those results will be adapted at ultra-high voltage for trouble prevention and on-line cable watch. diagnosis of those.

  • PDF

Implementation of Ray Tracing Processor for the Parallel Processing (병렬처리를 위한 고속 Ray Tracing 프로세서의 설계)

  • Choe, Gyu-Yeol;Jeong, Deok-Jin
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.5
    • /
    • pp.636-642
    • /
    • 1999
  • The synthesis of the 3D images is the most important part of the virtual reality. The ray tracing is the best method for reality in the 3D graphics. But the ray tracing requires long computation time for the synthesis of the 3D images. So, we implement the ray tracing with software and hardware. Specially we design the hit-test unit with FPGA tool for the ray tracing. Hit-test unit is a very important part of ray tracing to improve the speed. In this paper, we proposed a new hit-test algorithm and apply the parallel architecture for hit-test unit to improve the speed. We optimized the arithmetic unit because the critical path of hit-test unit is in the multiplication part. We used the booth algorithm and the baugh-wooley algorithm to reduce the partial product and adapted the CSA and CLA to improve the efficiency of the partial product addition. Our new Ray tracing processor can produce the image about 512ms/F and can be adapted to real-time application with only 10 parallel processors.

  • PDF

PD Diagnosis on 22.9kV XLPE Underground Cable using Ultra-wideband Sensor

  • Lwin, Kyaw-Soe;Lim, Kwang-Jin;Park, Noh-Joon;Park, Dae-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.3
    • /
    • pp.422-429
    • /
    • 2008
  • This paper presents compact low frequency ultra-wide band (UWB) sensor design and study of the partial discharge diagnosis by sensing electromagnetic pulse emitted from the partial discharge source with the newly designed UWB sensor. In this study, we designed a new type of compact low frequency UWB sensor based on microstrip antenna technology to detect both the low frequency and high frequency band of the partial discharge signal. Experiments of offline PD testing on medium voltage (22.9kV) underground cable mention the comparative results with the traditional HFCT as a reference sensor in the laboratory. In the series of comparative tests, the calibration signal injection test provided with the conventional IEC 60270 method and high voltage injection testing are included.

COMPLETION OF HANKEL PARTIAL CONTRACTIONS OF NON-EXTREMAL TYPE

  • KIM, IN HYOUN;YOO, SEONGUK;YOON, JASANG
    • Journal of the Korean Mathematical Society
    • /
    • v.52 no.5
    • /
    • pp.1003-1021
    • /
    • 2015
  • A matrix completion problem has been exploited amply because of its abundant applications and the analysis of contractions enables us to have insight into structure and space of operators. In this article, we focus on a specific completion problem related to Hankel partial contractions. We provide concrete necessary and sufficient conditions for the existence of completion of Hankel partial contractions for both extremal and non-extremal types with lower dimensional matrices. Moreover, we give a negative answer for the conjecture presented in [8]. For our results, we use several tools such as the Nested Determinants Test (or Choleski's Algorithm), the Moore-Penrose inverse, the Schur product techniques, and a congruence of two positive semi-definite matrices; all these suggest an algorithmic approach to solve the contractive completion problem for general Hankel matrices of size $n{\times}n$ in both types.

Oeterioration Diagnosis of Stator Windings in High Voltage Induction Motor Using Partial Discharge Characteristics (부분방전 특성을 이용한 고압 유도전동기 고정자 권선 열화진단)

  • 김덕근;정영일;이은석;임용배;김종서
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.481-484
    • /
    • 2001
  • High voltage induction motors are widely used in industrial factory because have many benefits. But the insulated materials of induction motor are aged by using time, electrical, thermal, circumstantial stresses and so on. Motor failures are occurred by these deterioration phenomena and give rise economic problems to user. In many motor failures, insulated material problems of stator winding happen frequently and occupy high percentages in the failure source. In this paper, the testing specimen(motorette) is manufactured by modeling of stator winding of high voltage induction motor and accelerating test is carried out. Partial discharge signals detected by RF sensor are used to analyze deterioration condition of stator windings. According to aging time, the 3D ( ${\Phi}$-Q-N) distribution and skewness of partial discharge signals are changed.

  • PDF

PD Measurement in oil with defects (결함별 절연유중 부분방전 측정 연구)

  • Sun, J.H.;Yi, S.H.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2004.11d
    • /
    • pp.67-69
    • /
    • 2004
  • Since partial discharges in power transformers weaken their insulation performance the detection of partial discharge is very important for prevention of fatal incidents. This study describes use of electromagnetic coupler for measurement of partial discharge of transformers. Spiral antennas of which bandwidth is 0.5GHz to 3GHz were used as coupler and setup in chamber for partial discharge tests. Test results showed that outputamplitudes are increased with PD increase and frequencies of signal measured by these antennas are mostly distributed below about 800MHz.

  • PDF