• 제목/요약/키워드: Partial Test

검색결과 1,769건 처리시간 0.027초

A Covariate-adjusted Logrank Test for Paired Survival Data

  • Jeong, Gyu-Jin
    • Communications for Statistical Applications and Methods
    • /
    • 제9권2호
    • /
    • pp.533-542
    • /
    • 2002
  • In this paper, a covariate adjusted logrank test is considered for censored paired data under the Cox proportional hazard model. The proposed score test resembles the adjusted logrank test of Tsiatis, Rosner and Tritchler (1985), which is derived from the partial likelihood. The dependence structure for paired data is accommodated into the test statistic by using' sum of square type' variance estimators. Several weight functions are also considered, which produce a class of covariate adjusted weighted logrank tests. Asymptotic normality of the proposed test is established and simulation studies with moderate sample size show the proposed test works well, particularly when there are dependence structure between treatment and covariates.

시중 즉석 조리 면의 Back Extrusion 텍스처 데이터에 대한 Partial Least Square Regression 분석 (Analysis of Partial Least Square Regression on Textural Data from Back Extrusion Test for Commercial Instant Noodles)

  • 김수경;이승주
    • 산업식품공학
    • /
    • 제14권1호
    • /
    • pp.75-79
    • /
    • 2010
  • 시중 즉석 면류의 관능적 성질과 back extrusion test 데이터에 대하여 partial least square regression(PLSR)을 실시하였다. 즉석유탕면 8종과 즉석비유탕면 2종에 대한 관능적 속성으로서 경도(A), 탄성(B), 껄끄러운 정도(C), 이에 박히는 정도(D), 굵기감(E)를 검사하였고, 실험 데이터로 힘-변형 곡선 전체를 사용하였다. PLSR의 회귀계수는 힘-변형곡선의 압착단계, 항복단계, 압출단계로 크게 구분되어 각관능속성에 대한 특유의 양 또는 음의 효과를 나타냈다. PLSR의 상관계수는 E>D>A>B>C, 오차(root mean square error of prediction expressed in sensory units)는 D>C>E>B>A, 예측능(relative ability of prediction)는 D>C>E>B>A 로 나타나 종합적으로 '이에 박히는 정도'가 PLSR의 적용에 가장 우수하게 나타났다. '경도'는 예측능은 낮았지만 상관성은 높아서 시료간 순위의 결정에 합당하게 평가되었다.

능력별 집단편성에 대한 교사와 학생의 인식 (A Study of Recognition About Students' Ability Grouping)

  • 김달효
    • 수산해양교육연구
    • /
    • 제19권3호
    • /
    • pp.390-402
    • /
    • 2007
  • According to the paradigm of Neo-liberalism, the issue of ability grouping has grown more and more in education of Korea. And because of the influence of ability grouping, now ability grouping is enforcing partially in the subjects of English and Mathematics. But ability grouping is going to expand to the all subjects. So, it is very important that how teachers and students are recognize about partial ability grouping in the subjects of English and Mathematics. Because that information about partial ability grouping can guide direction for the future educational policy. The purpose of this study was to actually analyze teacher's and students' recognition of partial ability grouping in the subjects of English and Mathematics. To accomplish this purpose, 622 middles school students and 552 teachers were sampled. As a tool of investigation, questionnaires about teacher's and students' recognition of partial ability grouping had made by researcher of this study were used. And as processing of data, t-test, F-test, Scheff-test were used. The result of this study is as follow. First, teachers who are experiencing ability grouping recognized more negative about ability grouping than teachers who are not experiencing ability grouping. Second, students who have low ability recognized more negative about ability grouping than students who have high ability. Third, teachers who are experiencing ability grouping recognized more ineffective about ability grouping than teachers who are not experiencing ability grouping. Fourth, students who have low ability recognized more ineffective about ability grouping than students who have high ability.

154kV급 중간접속부내의 부분방전 진단을 위한 HFCT 적용 기준신호 측정연구 (Measurement of Basis Signal with HFCT for Diagnosing Partial Discharge in Middle Joint Box of 154kV Grade)

  • 이용성;김정윤;이정용;최용성;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.217-219
    • /
    • 2005
  • To detect partial discharge of 154kV joint box, we have made experiment by using the HFCT sensor. Generally the signals which are detected in partial discharge test of underground power transmission cable are accompanied with both noises of high voltage and noises of surrounding power cable. The most noise in near to end part of joint box is corona, beside other noises flowed from surrounding area. Partial discharge test is difficulty due to these noises. First, we test reliability on both injection of calibration signal in NJB and removal of low frequency. After that, we had analyzed frequencies by measuring signals in IJB with 300[m] distance from NJB. Also we had measured S/N ratio by using the indirected injection method of calibration signal in IJB. In this experiment, two measurement methods were difference of detection acquisition, but these had the equal frequency properties.

  • PDF

154kV급 중간접속부내의 부분방전 진단을 위한 HFCT 적용 기준신호 측정 (Measurement of Basis Signal with HFCT for Diagnosing Partial Discharge in Middle Joint Box of 154kV Grade)

  • 안종현;윤주호;최용성;박대희;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.75-78
    • /
    • 2007
  • To detect partial discharge of 154kV joint box, we have made experiment by using the HFCT sensor. Generally the signals which are detected in partial discharge test of underground power transmission cable are accompanied with both noises of high voltage and noises of surrounding power cable. The most noise in near to end part of joint box is corona, beside other noises flowed from surrounding area. Partial discharge test is difficulty due to these noises. First, we test reliability on both injection of calibration signal in NJB and removal of low frequency. After that, we had analyzed frequencies by measuring signals in IJB with 300[m] distance from NJB. Also we had measured S/N ratio by using the indirected injection method of calibration signal in IJB. In this experiment, two measurement methods were difference of detection acquisition, but these had the equal frequency properties.

  • PDF

Effect of $H_2S$ Partial Pressure and pH of Test Solution on Hydrogen Induced Cracking of High Strength Low Alloy Steels

  • Kim, Wan Keun;Koh, Seong Ung;Kim, Kyoo Young;Yang, Boo Young;Jung, Hwan Kyo
    • Corrosion Science and Technology
    • /
    • 제4권6호
    • /
    • pp.236-241
    • /
    • 2005
  • Hydrogen induced cracking (HIC) is one of the hydrogen degradation phenomena of linepipe steels caused by $H_2S$ gas in the crude oil or natural gas. However, NACE TM0284-96 standard HIC test method is hard to satisfy the steel requirements for sour service application since it uses more severe environmental conditions than actual conditions. Therefore, in order to use steels effectively, it is required to evaluate HIC resistance of steels in the practical range of environmental severity. In this study, HIC resistance of two high strength low alloy (HSLA) steels being used as line pipe steels was evaluated in various test solutions with different $H_2S$ pressures and pH values. The results showed that the key parameter affecting crack area ratio (CAR) is $H_2S$ partial pressure of test solution when the pH value of test solution is not over 4. Hydrogen diffusivity was not a constant value, but it was rather affected by the hydrogen ion concentration (pH value) in the solution.

초음속 충동형 축류터빈의 부분분사비 효과에 대한 실험적 연구 (Experimental Investigation of the Effect of Partial Admission Ratio on the Performance of Supersonic Impulse Turbine)

  • 정은환;박편구;김진한
    • 한국추진공학회지
    • /
    • 제11권4호
    • /
    • pp.59-66
    • /
    • 2007
  • 부분분사비에 따른 초음속 충동형 터빈 성능변화에 대하여 실험적 연구를 수행하였다. 실험은 개방형액체로켓 엔진의 터보펌프에 사용되는 터빈을 이용하였으며 부분분사비 조절을 위해 실험용 노즐블럭을 설계/제작하였다. 실험에 사용된 터빈은 축대칭 수축-확산형 노즐을 갖고 있으며 작동노즐의 개수조절을 통해 부분분사비를 변화시켰다. 작동유체는 고압공기를 사용하였다. 실험결과 초음속 충동형 축류터빈은 부분분사비 변화에 따른 성능변화가 크지 않은 것으로 나타났다.

초고압 전력케이블용 중간 접속부 내의 부분방전신호 검출을 위한 박전극 응용 (The Application of Al-foil Electrode for Detecting Partial Discharge Signal in Middle Joint Box of EHV Power Cable)

  • 이용성;양종경;양종석;최용성;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.142-144
    • /
    • 2005
  • To detect partial discharge of 154kV joint box, we have made experiment by using the Al-foil electrode sensor. Generally the signals which are detected in partial discharge test of underground power transmission cable are accompanied wi th both noises of high voltage and noises of surrounding power cable. The most noise in near to end part of joint box is corona, beside other noises flowed from surrounding area. Partial discharge test is difficulty due to these noises. First, we had used Al-Foi1 sensor on middle joint box of 154[kV] underground transmission power cable, and then analyzed reliability of calibration signal by using the Al-Foi1 electrode sensor of NJB. From above results, decrement properties measured highly. But incase of injecting calibration signal of 500[pC] after measuring signals in IJB, the S/N ratio had about 25[dB] acquisition.

  • PDF

제어유의 문류품분효전에 미치는 형력의 영향 (A Study on the Effect of Pressure upon A.C Partial Discharge in Insulating Oil)

  • Sang-Hoon Kook
    • 대한전기학회논문지
    • /
    • 제32권7호
    • /
    • pp.227-233
    • /
    • 1983
  • Noticing that action of gaseous phase in insulating oil concerns to the discharging characteristics, I investigated the smalness pressure effects on quantity of the partial discharge and discharging pulse frequency. Tests are carried out between the niddle points in insulating oil at pressure being changed by gradual charge of inert gas Ar. At pressure as low as of 0.1-0.5 torr pulse frequency and maximum partial discharge reach peak while at pressure haigher than 20 torr no pulse is observed. The fact that pulse frequency has peak value at certain presure, which is changed either by charging Ar or by adding oil, implies that the action of gaseous phase depends on pressure. Test results are that partial discharge pulse are governed by pressure of Ar-charged oil, and less partial discharge pulses correspond to smaller bubbles whereas more partial descharge pulses correspond to larger bubbles.

  • PDF

SF_6 가스와 절연지의 절연계에서 가스압력에 따른 부분방전현상 (Partial Discharge Phenomenon with $SF_6$ Gas Pressures in Insulation consisting of Insulation Paper and $SF_6$ Gas)

  • 선종호;김광화;박정후;조정수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권2호
    • /
    • pp.65-71
    • /
    • 2001
  • This paper describes partial discharge phenomenon with SF6gas pressures in insulation consisting of insulation paper and SF6 gas. We made the specimens with SF6 gas gaps which exist between aramid papers and electrodes and calculated the electric field intensity in the these gaps. We measured the partial discharge inception voltages and the AC breakdown voltages with the test method of IEC 60060-2 and did the partial discharge degradation experiments with a constant voltage. According to gas pressures, the breakdown voltages in SF6gas gaps were calculated by Paschen's law. And these results showed the ability applying partial discharge inception voltages evaluation to Paschen's law and the relationship between the PD quantities occurring insulation breakdown and PD occurring area.

  • PDF