• 제목/요약/키워드: Partial Test

검색결과 1,769건 처리시간 0.03초

저압용 전기전자기기에 부분방전시험의 적용을 위한 기초연구 (A Basic Study on the Application of Partial Discharge Test on Low-voltage Electrical and Electronic Devices)

  • 길경석;송재용;문승보;차명수;황돈하;강동식
    • 한국전기전자재료학회논문지
    • /
    • 제19권6호
    • /
    • pp.586-590
    • /
    • 2006
  • This paper deals with the application of a partial discharge (PD) test on low-voltage electrical and electronic devices, which is recently being accepted as a non-destructive and a effective dielectric test method. A comparative analysis combined with the Withstand Voltage Test (WVT) specified in IEC standards was carried out on low-voltage insulation transformers. The results showed that the WVT causes insulation degradation of the specimen during the test by applying high voltage. However, the PD test can be performed in ranges from 30 % to 50 % of the test voltage specified in the WVT. Therefore, the PD test is successfully applicable for a non-destructive test method on low-voltage electrical and electronic devices as a replacement of the WVT.

경로 지연 고장 테스팅을 위한 부분 확장 주사방법 (Partial Enhanced Scan Method for Path Delay Fault Testing)

  • 김원기;김명균;강성호;한건희
    • 한국정보처리학회논문지
    • /
    • 제7권10호
    • /
    • pp.3226-3235
    • /
    • 2000
  • 반도체 집적 회로가 점점 복잡해지고 고속화되면서 반도체 집적 회로의 동작에 대한 검사 뿐 아니라, 회로가 원하는 시간 내에 동작함을 보장하는 지연 고장 검사의 중요성이 점점 커지고 있다. 본 논문에서는 경로 지연 고장에 대한 효율적인 테스트 입력 생성을 위하여 새로운 부분 확장 주사 방법을 제안한다. 본 논문에서는 유추와 할당을 적용한 테스트 입력 자동 생성기를 기반으로 하여 새로운 부분 주사 방법을 구현하였다. 우선적으로 표준 주사환경에서 테스트 입력을 생성한 후에 테스트 입력이 제대로 생성되지 않은 주사 사슬에 대하여 테스트 입력 생성기를 수행하는 동안의 정보를 이용하여 확장 주사 플립플롭이 적용될 플립플롭을 결정하였다. 확장 주사 플립플롭을 결정하는 기준으로서는 고장 검출율과 하드웨어 오버헤드를 사용하였다. 순차 회로인 ISCAS 89 벤치 마크 회로를 이용하여 실험을 수행하였으며, 실험을 통하여 표준 주사와 확장 주사 환경, 부분 확장 주사 환경에서 고장 검출율을 비교, 확인하였다. 그리고 새로운 알고리즘이 적용된 부분 확장 주사 방법에서 높은 고장 검출율을 확인함으로써 효율성을 입증하였다.

  • PDF

Regression Diagnostic Using Residual Plots

  • Oh, Kwang-Sik
    • Communications for Statistical Applications and Methods
    • /
    • 제8권2호
    • /
    • pp.311-317
    • /
    • 2001
  • It is necessary to check the linearity of selected covariates in regression diagnostics. There are various graphical methods using residual plots such as partial residual plots, augmented partial residual plots and combining conditional expectation and residual plots. In this paper, we propose the modified pseudolikelihood ratio test statistics based on these residual plots to test linearity of selected covariate. These test statistics which measure the distance between the nonparametric and parametric models are derived as a ratio of quadratic forms. The approximate distribution of these statistics is calculated numerically by using three moments. The power comparison of these statistics is given.

  • PDF

Partial Compatibility Test 를 이용한 로봇의 위치 추정 및 매핑의 Data Association (Data Association of Robot Localization and Mapping Using Partial Compatibility Test)

  • 염서군;최윤성;무경;한창수
    • 한국정밀공학회지
    • /
    • 제33권2호
    • /
    • pp.129-138
    • /
    • 2016
  • This paper presents a natural corners-based SLAM (Simultaneous Localization and Mapping) with a robust data association algorithm in a real unknown environment. Corners are extracted from raw laser sensor data, which are chosen as landmarks for correcting the pose of mobile robot and building the map. In the proposed data association method, the extracted corners in every step are separated into several groups with small numbers of corners. In each group, local best matching vector between new corners and stored ones is found by joint compatibility, while nearest feature for every new corner is checked by individual compatibility. All these groups with local best matching vector and nearest feature candidate of each new corner are combined by partial compatibility with linear matching time. Finally, SLAM experiment results in an indoor environment based on the extracted corners show good robustness and low computation complexity of the proposed algorithms in comparison with existing methods.

Reliability based partial safety factor of concrete containing nano silica and silica fume

  • Nanda, Anil Kumar;Bansal, Prem Pal;Kumar, Maneek
    • Computers and Concrete
    • /
    • 제26권5호
    • /
    • pp.385-395
    • /
    • 2020
  • The influence of combination of nano silica and silica fume, as partial cement replacement materials, on the properties of concrete has been studied through the measurement of compressive strength. The compressive strength of concrete in terms of mean, standard deviation and with-in-test coefficient of variation related to the variation in the nominated parameters have also been developed. The compressive strength data developed experimentally has been analyzed using normal-probability distribution and partial safety factors of composite concretes have been evaluated by using first order second moment approach with Hasofer Lind's method. The use of Nano silica and silica fume in concrete decreases the partial safety factor of concrete i.e., increase the reliability of concrete. The experimental results show that the properties of concrete having nano silica and silica fume in combination were better than that of a plain concrete. The SEM test results showing the level of Ca(OH)2 in plain concrete and consumption level Ca(OH)2 of concrete containing nano silica & silica fume have also been presented.

ppcor: An R Package for a Fast Calculation to Semi-partial Correlation Coefficients

  • Kim, Seongho
    • Communications for Statistical Applications and Methods
    • /
    • 제22권6호
    • /
    • pp.665-674
    • /
    • 2015
  • Lack of a general matrix formula hampers implementation of the semi-partial correlation, also known as part correlation, to the higher-order coefficient. This is because the higher-order semi-partial correlation calculation using a recursive formula requires an enormous number of recursive calculations to obtain the correlation coefficients. To resolve this difficulty, we derive a general matrix formula of the semi-partial correlation for fast computation. The semi-partial correlations are then implemented on an R package ppcor along with the partial correlation. Owing to the general matrix formulas, users can readily calculate the coefficients of both partial and semi-partial correlations without computational burden. The package ppcor further provides users with the level of the statistical significance with its test statistic.

Experiments on the bearing capacity of tapered concrete filled double skin steel tubular (CFDST) stub columns

  • Ren, Qing-Xin;Hou, Chao;Lam, Dennis;Han, Lin-Hai
    • Steel and Composite Structures
    • /
    • 제17권5호
    • /
    • pp.667-686
    • /
    • 2014
  • Tapered concrete filled double skin steel tubular (CFDST) columns have been used in China for structures such as electricity transmission towers. In practice, the bearing capacity related to the connection details on the top of the column is not fully understood. In this paper, the experimental behaviour of tapered CFDST stub columns subjected to axial partial compression is reported, sixteen specimens with top endplate and ten specimens without top endplate were tested. The test parameters included: (1) tapered angle, (2) top endplate thickness, and (3) partial compression area ratio. Test results show that the tapered CFDST stub columns under axial partial compression behaved in a ductile manner. The axial partial compressive behaviour and the failure modes of the tapered CFDST stub columns were significantly influenced by the parameters investigated. Finally, a simple formula for predicting the cross-sectional capacity of the tapered CFDST sections under axial partial compression is proposed.

부분방전 시험을 위한 기준신호 연구 (A Study on Calibration Signal for Test of the Partial Discharge)

  • 오용;윤주호;최용성;박대희;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.65-67
    • /
    • 2007
  • In this paper, we developed HPF (high pass filter) consisted of lumped LC components to decrease the noises that are detected in PD (partial discharge) measuring test, and adapted it to field test.

  • PDF

전력용 기기의 예방진단을 위한 부분방전측정 (The measurement of partial discharge for preventive diagnosis in power machinery)

  • 김태성;구할본;임장섭;정우성
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제7권1호
    • /
    • pp.42-48
    • /
    • 1994
  • The preventive diagnosis technique for power system is being highlighted as a research area for deterioration of insulation in machinery because of high-voltage power system. We make efforts to develop not only diagnosis of aging state but also detection of defects in the initial stage from preventive diagnosis technique. Especially, partial discharge is actively studied as a non-destructive diagnosis technique and very useful because partial discharge measurement reduces damage than conventional diagnosis technique. The loaded stress during this test is smaller than that of other diagnosis techniques. But the continuous research for various complicated analysis method is required because partial discharge has very small signals and its signals have complex forms. In this paper, the measurement of partial discharge was investigated and studied on many specimens with void. We made samples having artificial voids and measured partial discharge. In order to use as a practical diagnosis technique, we studied ways of measurement, measured illustrations and types of partial discharge which could be used in order to diagnose defects of power machinery.

  • PDF

변압기 부분방전에 의한 초음파 신호의 발생형태 (Patterns of the Ultrasonic Signal caused by Partial Discharge in Transformer)

  • 권동진;최인혁;정길조;박찬영;나현석;박재준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.581-584
    • /
    • 2000
  • Generally, it is known that many partial discharges are occurred in one voltage cycle. In this case, it is not easy to distinguish between ultrasonic signals caused by the partial discharge. We describes a pattern of the ultrasonic signal by the partial discharge in transformer. The test setup for ultrasonic signal measurement was to simulate a internal partial discharge by using a needle to plane electrodes. We compared the number of partial discharge and ultrasonic signal in one voltage cycle. The results showed that it was possible to distinguish between ultrasonic signals by analysing partial discharge detection method and ultrasonic signal on time domain.

  • PDF