• Title/Summary/Keyword: Partial Reliability

Search Result 433, Processing Time 0.023 seconds

Partial Safety Factors by SOSM/RC Combined Method (제2계 2차모멘트/신뢰성조건 조합방법에 의한 부분안전계수)

  • 이종헌;신현묵;손승요
    • Computational Structural Engineering
    • /
    • v.1 no.1
    • /
    • pp.79-85
    • /
    • 1988
  • The inverse algorithm of Point-Fitted Paraboloid Approximation is derived and used in reliability-based calculations. The algorithm of Reliability- Conditioned method is modified in the calculation of failure points such that nonlinear performance functions can be treated in like manner as linear cases without new formulations. SOSM/RC combined method results in probability of failure closed to specified one, and partial safety factors become nearly constant for a wide range of load ratio.

  • PDF

Normality of the MPLE of a Proportional Hazard Model for Informative Censored Data (정보적 중도절단을 고려한 최대 편우도 추정량의 정규성)

  • 정대현;원동유
    • Journal of Applied Reliability
    • /
    • v.1 no.2
    • /
    • pp.149-163
    • /
    • 2001
  • We study the normality of the maximum partial likelihood estimators for the proportional hazard model with informative censored data. The proposed models cover the cases in which the times to a primary event may be informatively or randomly censored and the times to a secondary event may be randomly censored. To estimate the parameters and to check the normality of the parameters in the model, we adopt the partial likelihood and counting process to use the martingale central limit theorem. Simulation studies are performed to examine the normality of the MPLE's for the five cases in which they depend upon the proportions of randomly censored and informative censored data.

  • PDF

System Reliability-Based Safety Assessment of Steel Cable-Stayed Bridges (체계신뢰성방법에 기초한 강사장교의 안전도평가)

  • 조효남;임종권;박경훈
    • Computational Structural Engineering
    • /
    • v.11 no.4
    • /
    • pp.351-360
    • /
    • 1998
  • 본 논문에서는 실용적 체계신뢰성에 기초한 강사장교의 안전도평가를 위한 체계적인 모형을 제안하였다. 공용중인 강사장교의 시스템 안전도평가를 위하여 요소신뢰성해석을 위한 케이블, 주형 그리고 주탑의 한계 상태모형과 각 요소들간의 조합파괴를 포함하는 주파괴경로를 정의할 수 있는 체계신뢰성해석 모형을 제안하였다. 요소신뢰성해석을 위한 수치해석기법으로는 AFOSM(Advanced First Order Second Moment) 방법을 사용하였고, 체계신뢰성해석을 위해서는 부분 ETA(partial Event Tree Analysis) 모형을 사용하였다. 제안된 방법의 타당성을 고찰하기 위하여 진도대교의 안전도 평가에 적용하였다. 부분 ETA 모혀을 사용한 체계신뢰성 평가 방법은 기존의 요소신뢰성 방법에 비해 구조물의 여용성을 충분히 반영하는 상당히 합리적이며 실제적인 결과를 보여주는 실용적인 방법으로 판단된다.

  • PDF

The impact of Wushu Image on Self-Congruity and Loyalty of Chinese College Students

  • Haoyu Tan;Sunmun Park
    • International Journal of Advanced Culture Technology
    • /
    • v.12 no.2
    • /
    • pp.438-447
    • /
    • 2024
  • The subjects of this study were college students who participate in Wushu in China. A total of 300 people, 189 male and 111 female, were sampled as research subjects through convenience sampling by sharing the questionnaire link online and sending emails. The research tool used in this study was a questionnaire. Based on the questionnaire that had secured reliability and validity in previous research, it was modified and supplemented to suit this study. The statistical analysis used for data analysis was frequency analysis, exploratory factor analysis, reliability analysis, and multiple regression analysis using SPSS Windows 20.0 Version. First, Wushu image was found to have a partial effect on self-congruity. Second, Wushu image was found to have a partial effect on loyalty. Third, the self-congruity of Wushu participants was found to partially affect loyalty.

Reliability Improvement of Insulation Diagnosis Using the Hydro-Generator On-Line Partial Discharge Monitoring System (수력발전기 On-line 부분방전 측정 시스템을 이용한 절연상태 진단의 신뢰성 향상)

  • Ok, Yeon-Ho;Lee, Eun-Woong;Lim, Jae-Il;Park, Ji-Kun;Kwak, Won-Ku;Lee, Jae-Heung;Shin, Jae-Pil;Shin, Byoung-Chol
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.469-475
    • /
    • 2009
  • Accident dangerousness of domestic hydro power generators which are operated in Korea is on the increase because of use at the long term. On this, the Off-line diagnosis techniques developed to the On-line by continued domestic technical development since 2000. Especially, On-line insulation diagnosis of domestic hydro power generator is possible by localization of partial electric discharge sensor and On-line insulation diagnosis system. This paper shows the diagnosis result that is applied localized Ceramic Coupler and PDMS-HG(Partial Discharge Monitoring System for Hydro Generator) at four Chung-ju hydro Generator used for 25 years. Particularly, the confidence of insulation diagnosis is improved by using high frequency filter and sampling the partial discharge signals which occur in site. For reviewing the confidence of On-Line insulation diagnosis system, we measured the outside noises and partial discharge signals during practical operation by using the partial discharge diagnosis system of the Full A/D process. And we reviewed the confidence of the On-Line insulation diagnosis system by comparing and analyzing these data.

Resistance Model for Reliability Analysis of Existing Steel Girder Bridges (강거더 교량의 신뢰성해석을 위한 저항모델 개발)

  • Eom, Jun Sik
    • Journal of Applied Reliability
    • /
    • v.13 no.4
    • /
    • pp.241-252
    • /
    • 2013
  • Because of financial and safety concerns, there are needs for more accurate prediction of bridge behavior. Underestimation of the bridge load carrying capacity can have serious economic consequences, as deficient bridges must be repaired or rehabilitated. Therefore, the knowledge of the actual bridge behavior under live load may lead to a more realistic calculation of the load carrying capacity and eventually this may allow for more bridges to remain in service with or without minor repairs. The presented research is focused on the reliability evaluation of the actual load carrying capacity of existing bridges based on the field testing. Seventeen existing bridges were tested under truck load to confirm their adequacy of reliability. The actual response of existing bridge structures under live load is measured. Reliability analysis is performed on the selected representative bridges designed in accordance with AASHTO codes for bridge component (girder). Bridges are first evaluated based on the code specified values and design resistance. However, after the field testing program, it is possible to apply the experimental results into the bridge reliability evaluation procedures. Therefore, the actual response of bridge structures, including unintentional composite action, partial fixity of supports, and contribution of nonstructural members are considered in the bridge reliability evaluation. The girder distribution factors obtained from the tests are also applied in the reliability calculation. The results indicate that the reliability indices of selected bridges can be significantly increased by reducing uncertainties without sacrificing the safety of structures, by including the result of field measurement data into calculation.

Evaluation of Reliability on the 6.6kV Class Ceramic Coupler for On-line Partial Discharge Measurement in Winding Machines (권선형기기 On-line 부분방전 측정용 6-6kV급 Ceramic Coupler의 신뢰성 평가)

  • Kang Dong-Sik;Kim Yong-Joo;Yun Youn-Ho
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.2
    • /
    • pp.69-75
    • /
    • 2005
  • In order to improve the reliability of high voltage rotating machines and mold transformers, it is necessary to understand the breakdown mechanism and life assessment of the high voltage winding parts. Especially the on-line PD test provides the ability to monitor effects, such as slot discharge, internal discharge, and end-winding discharge without interrupting the electrical machines, this method has been proven the major testing technology. Capacitive couplers have been the most widely used sensors for the on-line partial discharge detection in rotating machines nowadays. This paper deals with the electrical characteristics and long-term reliability of a ceramic coupler(CC), which can be easily mounted into high voltage input terminal part, has been developed and tested to continuously measure PD activity during operating condition. This paper presents electrical characteristics (dielectric loss angle, capacitance, PD inception level, breakdown voltage, and frequency response bandwidth) and long-term life test result of the developed 6.6 kV class on-line ceramic coupling sensor. It was found that this sensor had good electrical characteristics to detect PD activity during the operating condition with its detection frequency band is between several and several tens MHz. Also, the voltage life of the 6.6kV class ceramic coupler was calculated over 60 years.

Load & Resistance Factors Calibration for Limit State Design of Non-Perforated Caisson Breakwater (직립무공케이슨방파제 한계상태설계를 위한 하중저항계수 보정)

  • Kim, Dong Hyawn
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.31 no.6
    • /
    • pp.351-355
    • /
    • 2019
  • Load resistance factors for the limit state design of vertical caisson breakwaters are presented. Reliability analysis of 16 breakwaters in nationwide ports was conducted to calculate the partial safety factors and they were converted into load and resistance factors. The final load resistance factor was calibrated by applying the optimization technique to the individually calculated load resistance factors. Finally, the breakwater was redesigned using the optimal load resistance factor and verified whether the target level was met. The load resistance factor according to the change of the target reliability level is presented to facilitate the limit state design of breakwater.

On-line integration of structural identification/damage detection and structural reliability evaluation of stochastic building structures

  • Lei, Ying;Wang, Longfei;Lu, Lanxin;Xia, Dandan
    • Structural Engineering and Mechanics
    • /
    • v.63 no.6
    • /
    • pp.789-797
    • /
    • 2017
  • Recently, some integrated structural identification/damage detection and reliability evaluation of structures with uncertainties have been proposed. However, these techniques are applicable for off-line synthesis of structural identification and reliability evaluation. In this paper, based on the recursive formulation of the extended Kalman filter, an on-line integration of structural identification/damage detection and reliability evaluation of stochastic building structures is investigated. Structural limit state is expanded by the Taylor series in terms of uncertain variables to obtain the probability density function (PDF). Both structural component reliability with only one limit state function and system reliability with multi-limit state functions are studied. Then, it is extended to adopt the recent extended Kalman filter with unknown input (EKF-UI) proposed by the authors for on-line integration of structural identification/damage detection and structural reliability evaluation of stochastic building structures subject to unknown excitations. Numerical examples are used to demonstrate the proposed method. The evaluated results of structural component reliability and structural system reliability are compared with those by the Monte Carlo simulation to validate the performances of the proposed method.

Al-foil Electrode for Detecting Partial Discharge in Middle Joint Box (초고압 전력케이블용 중간접속부내 부분방전 검출을 위한 박전극)

  • Shin, Hyun-Mahn;Kim, Hyang-Kon
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.211-213
    • /
    • 2008
  • To detect partial discharge of 154kV joint box, we have made experiment by using the Al-foil electrode sensor. Generally the signals which are detected in partial discharge test of underground power transmission cable are accompanied with both noises of high voltage and noises of surrounding power cable. The most noise in near to end part of joint box is corona, beside other noises flowed from surrounding area. Partial discharge test is difficulty due to these noises. First, we had used Al-Foil sensor on middle joint box of 154[kV] underground transmission power cable, and then analysed reliability of calibration signal by using the Al-Foil electrode sensor of NJB. From above results, decrement properties measured highly. But incase of injecting calibration signal of 500[pC] after measuring signals in IJB, the S/N ratio had about 25[dB] acquisition.

  • PDF