• 제목/요약/키워드: Partial Discharge(PD)

검색결과 502건 처리시간 0.022초

Analysis of Off-Line and On-Line Partial Discharge in High Voltage Motor Stator Windings

  • Kim, Hee-Dong;Kong, Tae-Sik;Lee, Sang-Kil;Kim, Beom-Soo;Kim, Doo-Young
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1086-1092
    • /
    • 2015
  • The off-line and on-line partial discharge (PD) in the stator winding of three high-voltage (HV) motors (1,400 HP, 6.6 kV) is measured and analyzed in this paper. The off-line PD is measured at high values between 24,300 ~ 36,100 pC after 18 years of motor operation. Spare replacement motors were not available for testing the degree of deterioration of the stator windings in standstill status. Therefore, on-line periodic analysis was conducted to monitor the trend of PD after installing a ceramic sensor (110 pF, 6.6 kV) in the terminal box for each phase of each motor. In the stator winding of the No.1 and No.2 HV motors, which showed high magnitudes of off-line PD and low magnitudes of on-line PD, defects are expected to appear in the neutral end of the winding. On the contrary, in the stator windings of the No.3 HV motor, which exhibits high off-line and on-line PD magnitude, defects are expected to appear in the terminal end of the winding where a voltage close to the phase voltage is applied.

Partial Discharge Signal Denoising using Adaptive Translation Invariant Wavelet Transform-Online Measurement

  • Maheswari, R.V.;Subburaj, P.;Vigneshwaran, B.;Iruthayarajan, M. Willjuice
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.695-706
    • /
    • 2014
  • Partial discharge (PD) measurements have emerged as a dominant investigative tool for condition monitoring of insulation in high voltage equipment. But the major problem behind them the PD signal is severely polluted by several noises like White noise, Random noise, Discrete Spectral Interferences (DSI) and the challenge lies with removing these noise from the onsite PD data effectively which leads to preserving the signal for feature extraction. Accordingly the paper is mainly classified into two parts. In first part the PD signal is artificially simulated and mixed with white noise. In second part the PD is measured then it is subjected to the proposed denoising techniques namely Translation Invariant Wavelet Transform (TIWT). The proposed TIWT method remains the edge of the original signal efficiently. Additionally TIWT based denoising is used to suppress Pseudo Gibbs phenomenon. In this paper an attempt has been made to review the methodology of denoising the PD signals and shows that the proposed denoising method results are better when compared to other wavelet-based approaches like Fast Fourier Transform (FFT), Discrete Wavelet Transform (DWT), by evaluating five different parameters like, Signal to noise ratio, Cross-correlation coefficient, Pulse amplitude distortion, Mean square error, Reduction in noise level.

불평등 전계에서 $SF_6/CF_4$ 혼합가스의 절연내력과 PD특성 (Breakdown Voltage and PD Characteristics of $SF_6/CF_4$ Mixtures in Nonuniform Field)

  • 황청호;성허경;허창수
    • 전기학회논문지
    • /
    • 제57권4호
    • /
    • pp.635-640
    • /
    • 2008
  • New gas mixtures are now finding applications such as interrupting media for high-voltage circuit breakers. These mixtures consist of a high content of carbon tetrafluoride($CF_4$) added to sulfur hexafluoride($SF_6$). Nowdays $SF_6$ has been established for the use in gas insulated substations due to its high insulation withstand level and good arc quenching capability. At this paper Breakdown characteristics were investigated for $SF_6/CF_4$ mixtures when AC voltage and standard lightning impulse voltage(LI) was applied in a needle-plane electrodes. And partial discharge(PD) experiments were carried out in the test chamber which was made in needle-plane electrode. And ${\Phi}$-Q-N distribution of partial discharge signals was analyzed. The total pressure of the $SF_6/CF_4$ mixtures was varied within the range of 0.1-0.5 Mpa in the test chamber. The breakdown voltage in needle-plane electrode displayed N shape characteristics for increasing the content of $SF_6$ at positive impulse voltage and the PD inception voltage was increased slightly when pressure of $SF_6/CF_4$ Mixtures was increased. Maximum PD inception voltage is showed in 80% SF6/20%$CF_4$.

An Application of the Novel Techniques Detecting Partial Discharge Employable to GIS Using Optical Sensor

  • Ryu, Cheol-Hwi;Jung, Seung-Yong;Koo, Ja-Yoon;Yeon, Man-Seung
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권3호
    • /
    • pp.396-400
    • /
    • 2007
  • A novel technique has been proposed and related experimental works have been performed in order to detect the partial discharges and the location of the possible defects introduced into the Gas Insulated Switchgear. For this purpose, a prototype HY Pockels sensor has been developed and then employed in order to investigate its field applicability for finding the location of the defects using a 170kV GIS mock-up. Our proposed sensor enables us to measure the electric field variation due to the PD occurrence. In addition, the different PD patterns are observed, which might be dependant on the location and the distance of the sensor with respect to the PD source. Throughout this work, its linear response has been proved to be admissible as a function of the applied voltage. And also the position of the PD source might be distinguished by comparing the PD patterns.

부분방전에 의한 주계전기의 절연성능 평가 (Insulation Performance Estimation of Main Relays by Partial Discharges)

  • 길경석;김일권;박대원;송재용;이강원;조은제
    • 한국철도학회논문집
    • /
    • 제10권4호
    • /
    • pp.388-392
    • /
    • 2007
  • A new dielectric test on main relays of electric traction vehicles, the partial discharge(PD) test, is proposed. The PD test will not affect the insulation performance of specimen during the test and provide much more detailed information on insulation, the types of defects, and so on. Insulation performance of relays is estimated by discharge inception voltage(DIV), discharge extinction voltage (DEV), and apparent charge as a function of test voltage and time. Three main relays of different manufacturing date were estimated by applying AC voltage with three patterns in ranges of $0{\sim}1,200[V]$. From the results, we could estimate insulation state and which types of defects exist in them.

초광대역과 단일주파수(협대역) UHF 부분방전 검출기법 비교 (Ultra-wide bandwidth versus narrow bandwidth PD detection techniques for UHF partial discharge monitoring system)

  • 박기준;구선근;윤진열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1655-1657
    • /
    • 2002
  • Ultra-wide bandwidth (UWB), narrow bandwidth (single frequency), and a combination of both technologies have been studied for the ultra-high frequency (UHF) partial discharge (PD) monitoring system as a detection scheme. We have experimentally compared those detection methods using a mock-up of 362 kV class single phase gas-insulated switchgear (GIS) and a stable PD source. A rolling-ball type PD cell that produces PDs of about 10 pC, is placed at one end of the GIS. An internal UHF PD sensor was attached several meters away from the PD source. The PD spectrum was measured up to 3 GHz. A useable bandwidth of more than 1 GHz was used to measure UWB signals from the PD. To simulate the narrow bandwidth scheme a bandwidth of 100 kHz centered at several different frequencies was used.

  • PDF

전력케이블의 절연결함에 따른 부분방전 특성분석 (Analysis of PD Characteristics by Types of Insulation Defects in Power Cables)

  • 최재성;박찬용;김선재;한주섭;길경석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1977-1983
    • /
    • 2009
  • This paper described partial discharge(PD) patterns depending on types of insulation defects in CNCO-W cable(Concentric Neutral Closs-linked Polyethylene Insulated Polyolefin-Water Proof Sheathed Power Cable). The PD measurement system consists of a coupling network, a detection impedance, and a low noise amplifier. A 16 bit, 250 MS/s data acquisition system was used to analyze PD patterns. To simulate insulation defects in a power cable, a needle with the curvature radius of $10{\mu}m$ was inserted into the insulation part. We measured phase ($\Phi$), magnitude (q), and counts (n) of PD pulse for the defects, and classified PD patterns using the PRPD (phase Resolved Partial Discharge) method. From the analysis of acquired PD signals, we could find that a unique PD pattern is formed according to the types of defect.

  • PDF

수력발전기 고정자 노후권선의 모의결함 시편에 대한 부분방전 파라미터 변화 분석 (Analysis of Parameters on Partial Discharges from Insulation Defects of used Hydro Generator Stator Windings)

  • 오봉근;김현일;강성화;임기조
    • 한국전기전자재료학회논문지
    • /
    • 제20권7호
    • /
    • pp.645-649
    • /
    • 2007
  • Partial discharge(PD) test for simulated insulation defects of used hydro generator stator winding was conducted to analyze the PD Parameters. Simulated insulation defects are classified by 5 types corona, slot, internal, multi and aging defect. Phase resolved partial discharge, statistical parameter (skewness, kurtosis), PD magnitude as a function of the test voltage(Q-V curve) and PD magnitude change under test voltage for 2 minutes are used as PD parameters. The analysis of PD parameters by 4 types are proved to be useful methods. In particular, PD parameter characteristics of aging defect could help to assess the aging condition of stator winding because aging defect has more weak insulation strength than other insulation defects : PD distribution is wide and flat, PD rises rapidly near $0^{\circ}\;and\;180^{\circ}$ and Q-V curve rises sharply and then gently drops.

몰드 변압기의 절연 진단을 위한 로고우스키형 부분방전 센서의 설계 및 제작 (Design and Fabrication of Rogowski-type Partial Discharge Sensor for Insulation Diagnosis of Cast-Resin Transformers)

  • 이경렬;김성욱;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제35권6호
    • /
    • pp.594-602
    • /
    • 2022
  • Cast-resin transformers are widely installed in various electrical power systems because of their low operating cost and low influence on external environmental factors. However, when they have an internal defect during the manufacturing process or operation, a partial discharge (PD) occurs, and eventually destroys the insulation. In this paper, a Rogowski-type PD sensor was studied to replace commercial PD sensors used for the insulation diagnosis of power apparatus. The proposed PD sensor was manufactured with four different types of PCB-based winding structures, and it was analyzed in terms of the detection characteristics for standard calibration pulses and the changes of the output voltage according to the distance. The output increased linearly in accordance with the applied discharge amount. It was confirmed that the hexagon structure sensor had the highest sensitivity, because the winding cross-sectional area of the sensor was larger than others. In addition, as the distance from the defect increased, the output voltage of the sensors decreased by 7.32% on average. It was also confirmed that the attenuation rate according to the distance decreased as the input discharge amount increased. For the application of this new type sensor, PD electrode system was designed to simulate the void defect. Waveforms and PRPD patterns measured by the proposed PD sensors at DIV and 120% of DIV were the same as the results measured by MPD 600 based on IEC 60270. The proposed PD sensors can be installed on the inner wall of the transformer tank by coating its surfaces with a non-conductive material; therefore, it is possible to detect internal defects more effectively at a closer distance from the defect than the conventional sensors.

사우디아라비아 380kV XLPE Cable의 신뢰성 확보를 위한 온라인 부분방전 모니터링 시스템 구축 (Construction of On-line Partial Discharge Monitoring System for 380kV XLPE Cable in Saudi Arabia)

  • 서인진;이전선;김한중;김종철;김정윤;이현선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.95-96
    • /
    • 2008
  • We constructed an on-line PD monitoring system for the 380kV U/G Cable project at the Riyad 9012 substation in Saudi-arabia. The system will be monitoring the termination of the two 380kV XLPE Cables to prevent unexpected failure of the cable insulation. The system had been tested in the laboratory and on-site for detection of various PD signals and reliability of operation. The system distinguish the existence and nonexistence of the partial discharge and then judge the source of partial discharge using automatic PD pattern recognition software.

  • PDF