• Title/Summary/Keyword: Parking Lot

Search Result 428, Processing Time 0.027 seconds

Determination of Types and Element on Parking Ramp (주차장 램프 형식 결정 및 제원 산정에 관한 연구)

  • Kwon, Sung-Dae;Kim, Yoon-Mi;Nam, Chang-Kyu;Ha, Tae-Jun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.5
    • /
    • pp.2021-2031
    • /
    • 2013
  • Due to the rapid economic growth within the nation, the quality of life of individuals have improved dramatically. The scope of living activities of individuals have also extended, resulting in a rapidly increasing demand for automobiles. The number of vehicles registered in Korea is rapidly increasing and will reach 188.71 million as of December 2012. Compared to the registered residents of 50.94 million provided by the Ministry of Public Administration and Security, the registered population reflects about 4 people per every automobile. Due to the high demands for vehicles, the demands for parking lots in collective housing and businesses are also increasing. In reality, the current state of expansion of parking lots are underground, due to the limited available space on ground level. Specifically, the slope of a parking lot cannot exceed 17% linear slope and 14% curved slope according to the 'parking lot laws', however studies show that the driver feels at risk for safety when stopped on the parking ramp while driving in the parking lot. This study seeks to examine the suitability of parking lot ramps, concerning the safety aspects of the driver. First, the ramp type was categorized as linear or curved, then test drives were performed based on variations of slopes, slant distances, directions and points. A survey was administered to the driver after the completion of the test drive, in order to element design for an ideal ramp. In the case of curved ramp, the results of the estimate suggests a counterclockwise, slope at a maximum of 12% incline. The maximum slope for a linear ramp was analyzed to be between 13~14%, suggesting that slope greater than 15% need to be eliminated. In conclusion, it is anticipated that the element design parking ramp reported in this study will help to serve as a reference for future parking lot related guidelines, and provide cost effective traffic safety mechanisms in future parking lot businesses to follow.

A Study on Industrial Site Annexed Parking Unit Calculation Method by Considering Facility Use and Scale Characteristics (용도 및 규모특성을 고려한 산업단지 공장시설의 부설주차장 설치기준 개선방안 연구)

  • Ahn, Woo-Young;Lee, Seon-Ha
    • International Journal of Highway Engineering
    • /
    • v.12 no.2
    • /
    • pp.129-136
    • /
    • 2010
  • The present annexed parking lot standards for buildings in Parking Act are categorized in 9 groups in terms of recreation, culture and assembly, housing, factory, and so on, in which same grouped facilities have uniform parking standards. The local governments have authority to itemize groups and adjust parking standards within ${\pm}50%$ ranges. These days diversity in building types and functions need more fractionated parking standards; however, most local governments focusing merely on applying strengthened parking standards in general without systematic rules of consistency. The current problem of parking standards being used is lack of regarding facility characteristics; expecially, a large sized high-tech manufacturing facility located in industrial site is still applied by same parking standards as normal manufacturing facility, even though most part of manufacturing process is automated and hence less manpower is employed. This paper presents a systematic method of analyzing parking generation unit for factory facilities in industrial site in terms of facility use and scale characteristics.

Design and Implementation of Parking Information Support System for Inner Parking Lot Based on Microprocessor (마이크로프로세서 기반의 실내 주차정보 제공 시스템 설계 및 구현)

  • Yoo, Si-On;Oh, Hyoung-Jin;Oh, Kab-Suk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.1
    • /
    • pp.51-59
    • /
    • 2010
  • Apartment complex, buildings, markets and department stores have inner parking lots which can accept many cars but drivers waste lots of times to find the empty parking spaces in crowding parking lots. In this paper, we proposed the inner parking information support system based on microprocessor which can decrease roaming times to find vacant parking spot in confusing parking lots through notice monitor and provide SMS to make it easy to find parked place. Proposed system consist with RFID system for detecting access of cars, microprocessor system for processing data of checking existence of cars on parking spots and communicating with server, and server system which processes information of cars' in and out, guides empty parking spots and parked location to drivers. Suggested system is realized by handmade model parking lot size of 8 cars, and we confirmed practicality by providing information using parking notice monitor and single message service.

A Study on Parking Generation Forecasting Model for Factory Facilities in Industrial Site (산업단지 공장시설의 주차수요예측모형 구축에 관한 연구)

  • Ahn, Woo-Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.1D
    • /
    • pp.37-44
    • /
    • 2010
  • The present annexed parking lot standards for buildings in Parking Act are categorized in 9 groups with 13 parking standards in terms of recreation, culture and assembly, housing, factory, warehouse, and so on, in which same grouped facilities have same parking standards. These days diversity in building types and functions need more fractionated parking standards; however, most local governments focusing merely on applying strengthened parking standards in general without systematic rules of consistency. The current problem of parking standards being used is lack of regarding facility characteristics; expecially, a large sized high-tech manufacturing facility located in industrial site is still applied by same parking standards as normal manufacturing facility, even though most part of manufacturing process is automated and hence less manpower is employed. This paper presents a parking generation forecasting model for factory facilities in industrial site in terms of facility use and scale characteristics.

Characterization of Stormwater Pollutants and Estimation of Unit Loads for Road and Parking Lot in Gyeongan Stream Watershed (경안천지역의 도로 및 주차장에 대한 강우유출수의 특성분석과 원단위 산정)

  • Go, Sung-Hun;Memon, Sheeraz Amed;Lee, Chang-Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.5
    • /
    • pp.689-696
    • /
    • 2009
  • Unit load approach has been used to estimate the non-point pollutant load in Total Water Pollution Load Management System (TWPLMS). In this study, locally applicable unit loads for road and parking lot were developed based on the measurements of 9 rainfall events from 2007 to 2008 in Yongin city of Gyeongan stream watershed. Observations showed that stormwater runoff began at low precipitation (>1 mm) and peak pollutant concentration occurred at the beginning of the runoff because of impervious nature of the sites. Averaged event mean concentrations (EMCs) of road (parking lot) were estimated as COD 105.36(62.69) mg/L, BOD 15.94(13.20) mg/L, TSS 183.45(66.52) mg/L, T-N 4.63(3.28) mg/L, T-P 0.45(0.39) mg/L. Higher EMCs at the road than parking lot may reflect heavier traffic. Unit loads Estimated from the EMCs and 10 year average rainfall data were COD $331.17kg/km^2{\cdot}day$, BOD $50.20kg/km^2{\cdot}day$, TSS $580.13kg/km^2{\cdot}day$, T-N $14.68kg/km^2{\cdot}day$, T-P $1.43kg/km^2{\cdot}day$ in the road and COD $186.59kg/km^2{\cdot}day$, BOD $39.22kg/km^2{\cdot}day$, TSS $199.15kg/km^2{\cdot}day$, T-N $9.70kg/km^2{\cdot}day$, T-P $1.16kg/km^2{\cdot}day$ in the parking lot. The estimated unit loads are not so comparable to the ones listed in TWPLMS technical guideline and published data that locally developed unit loads should be used to estimate non-point pollutant loads.

Community ambulation in patients with chronic post-stroke hemiparesis : Comparison of walking variables in five different community situations (만성 뇌졸중 환자의 지역사회 보행: 다섯 보행 조건의 비교)

  • Hwang, Eun-Ok;Oh, Duck-Won;Kim, Suhn-Yeop
    • Journal of Korean Physical Therapy Science
    • /
    • v.16 no.1
    • /
    • pp.31-39
    • /
    • 2009
  • Background: Community ambulation has been recently recognized as one of the most essential factors of activities of daily living in patients with post-stroke hemiparesis. This study aimed to compare walking velocity and step number in 5 community situations in patients with post-stroke hemiparesis. Methods: Ten chronic stroke patients volunteered for this study. The main variables analyzed were walking speed and step number, and these were measured in 5 different community situations: a physical therapy room, a parking lot, a bank, a crosswalk, and a hospital lobby. The measurements obtained for walking in the physical therapy room were measured using a 10m walk test and were used as baseline data for comparison with each option. The ambulation distance was set at 300m for the parking lot and the bank and 150m for the crosswalk and hospital lobby. For data analysis, walking speed and step number were standardized with the distance options of each ambulation. Results: Compared to the walking speed in the physical therapy room, those in the other situations, except for the parking lot, were significantly different (p<.05). Moreover, there were significant differences in the speeds between the bank and the parking lot and between the parking lot and the crosswalk (p<.05). Compared to the step number in the physical therapy room, those in all situations except for the crosswalk were significantly different (p<.05). Further, there was a significant difference in the step number between the bank and the crosswalk (p<.05). Conclusion: The walking ability of patients with hemiparesis in real environments within a community could be different from that in a physical therapy room. Therefore, the evaluation of walking should be performed in a variety of community situations.

  • PDF

The Development of a Model for Selecting Method of Entry for Apartment in Remodeling an Underground Parking Lot (지하주차장 리모델링 공사시 주동진입방법 선정 모델 개발)

  • Song, Nak-Hyun;Jung, In-Su;Lee, Chan-Sik
    • Korean Journal of Construction Engineering and Management
    • /
    • v.10 no.2
    • /
    • pp.65-74
    • /
    • 2009
  • It is expected that the number of apartment complexes in Korea that are over 20 years old will rapidly increase to more than 3,500,000. Consequently, the remodeling of these buildings is being revitalized throughout the country. Among the requirements for such remodeling, the expansion of parking lots has considerable weight. When enlarging a parking lot, the access route from an underground floor to the main building (i.e., the means of entry into the main building) determines the possibility of vertical enlargement for elevators, the size of the parking lot, the construction period, and construction expenses, etc. When enlarging an underground parking lot of an apartment complex, the access between the main building and the parking lot, as well as the inhabitants' requirements for entering the main building, are generally determined based on the designer's experience, rather than on the exact estimation of the peculiarity of the complex. In order to resolve such a problem, when enlarging an underground parking lot, a systematic and rational method is needed for selecting the means of entry into the main building. In this study, a selection model is derived for the method of selecting an access route into the main building when constructing an underground parking lot, in order to provide a reasonable decision-making process. A research method was investigated for determining the access route into the main building when enlarging a parking lot. On the basis of research carried out through in-depth interviews with experts, the characteristics for each means of entry into the main building were analyzed and the factors affecting the selection of the access route were deduced. The affecting factors selected were construction efficiency, convenience efficiency and economic efficiency. Weight values were then estimated for the selected affecting factors by applying the AHP method. Results showed that convenience efficiency, which gained the highest value, is the most important factor in selecting the means of entry into the main building. The most suitable means of entry into the main building was also suggested after estimating the applicability of the site by selecting complexes with remodeling possibility. This study will be applied as a reference for selecting the means of entry into the main building when constructing an underground parking lot particularly for older apartment complexes.

Design and Implementation of Distributed Parking Space Management Service in Scalable LPWA-Based Networks (대규모 LPWA기반 네트워크에서 분산된 주차 공간 관리서비스의 설계 및 구현)

  • Park, Shinyeol;Jeong, Jongpil;Park, Dongbeom;Park, Byungjun
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.7 no.10
    • /
    • pp.259-268
    • /
    • 2018
  • Due to the development of cities and the increase of vehicles, effective control of parking space management service in cities is needed. However, the existing parking lot management system does not provide limited or convenient service in terms of space and time. In this paper, we propose distributed parking space management service based on large scale LPWA (Low-Power Wide-Area). The parking sensor collects parking space information from the parking lot and is transmitted over a low-power wide network. All parking data is processed and analyzed in the IoT cloud. Through a parking space management service system in all cities, users are given the temporal convenience of determining the parking space and the area efficiency of the parking space.

A Study on the Improvement of the Method to Evaluate the Status of Parking Supply and Demand (주차장 수급실태 평가 방법의 개선에 관한 연구)

  • Shin, Hyoung O;Yoon, Jae Yong;Choi, Jin Seon;Lee, Eui Eun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.2
    • /
    • pp.351-359
    • /
    • 2019
  • In order to improve the problem of parking which is getting worse day by day, the municipality carries out a survey on the actual situation of the parking lot supply and demand periodically according to the related law. However, in the existing evaluation method, the parking demand that occurs under the condition that the demand is suppressed by the parking supply and regulation due to the limit of the survey method is investigated. In addition, the analysis is conducted only for the present year, and prediction and analysis of future parking problems are limited. Therefore, we propose a method to evaluate the status of parking supply and demand, which is differentiated to improve the problem of the existing evaluation method. As a result, comparing the existing method with the improved method, it can be seen that the improved evaluation method can be useful for establishing the long-term parking policy for the improvement of parking problems.

Study on the Analysis of Spatial Structure in Jeju Island Focusing on Parking Status (주차실태를 중심으로 한 제주도 공간구조 분석 연구)

  • Hwang, Kyung-Soo;Yang, Jeong-Cheol;Jo, Hang-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.667-675
    • /
    • 2021
  • The purpose of this study is as follows: First, to analyze the spatial structure of Jeju by analyzing the rate of parking demand and supply; Second, to determine the parking service imbalance between regions; and third, to elucidate the causes of this spatial structural parking service imbalance and provide effective measures. Due to the rapid population and tourism growth, Jeju is suffering from traffic congestion and serious parking problems. For this, the ways to efficiently utilize the existing parking spaces were identified through spatial structure analysis based on the parking demand and supply in the Jeju area. As short-term policy, the following changes were proposed: switching to small-scale eup or myeon blocks of parking space, use of shared parking system, and repairing side streets in residential areas. As mid-to-long-term policy, it is linked to other means of transportation as follows: parking demand management policy through modal share by reorganizing public transportation routes or expanding traffic facilities; securing park-and-ride lots; and different parking pricing for different time periods. To implement these policies, each area of the public sector, private sector, and private-public partnership should develop the bond of sympathy by areas and participants.