A Study on Convenience Facilities of the Physically Disabled in the Public Buildings - Focused on municipal buildings in Jeonbuk Province - (공공업무시설의 장애인편의시설 실태조사에 관한 연구 - 전라북도 자치단체청사를 중심으로 -)

  • Park, Chang-Sun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.11 no.3
    • /
    • pp.41-49
    • /
    • 2005
  • The purpose of this study is to analysis of convenience facilities for disabled in the municipal buildings. The physically disabled based on comparative analysis of disabilities code in Korea. For this objective, the code and guideline were analysed, and based on the analysis the checklist was developed for field observation. Convenience facilities ought to consider various aspects like size, and spatial composition of facilities, safety factors. and the present conveniences facility regulation. The research was conducted for municipal buildings located in Jeonbuk province. The procedures for research was made to investigate the finding of architectural related code and faculty standards. The results of investigation should be complemented and clarified guidelines in terms of accessibility and convenience which in detail. If the disabled would be convenient to use municipal buildings facilities, there should be no difficulties. As a result, convenience facilities for disabled in the municipal buildings has been improved that the design concept for the disabled person in general architectural planning.

  • PDF

Short-Time Emergency Rating Considering Facility-Conditions of Transmission Lines in KEPCO (송전선로의 설비특성을 고려한 단시간정격 검토)

  • Sohn, H.K.;Lee, H.K.;Park, I.P.;Han, H.J.;Kim, B.G.;Ahn, S.H.;Lee, D.I.;Jang, T.I.;Choi, I.H.;Choi, J.S.;Kim, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.448-449
    • /
    • 2008
  • This paper presented survey and analysis on short-term Emergency rating by considering facility-conditions of transmission lines in KEPCO, such as the age of ACSR conductors, a place of sleeve connecting, and road clearance, etc.

  • PDF

A Study on Function of Greentourism Core Facilities in Japan (일본의 농촌관광의 거점시설 기능에 관한 연구)

  • Lee, Eul Gyu;Kim, Jun Kyung
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.10 no.3
    • /
    • pp.67-74
    • /
    • 2008
  • The roles and needs for the greentourism facilities require the associated functions and systems which can be determined from considering the existing successful facilities. Some of successful examples for the greentourism facilities in Japan have been investigated, and their functions and systems carefully examined. This paper is intended to provide a meaningful step for introducing and applying the functions and systems for the greentourism facilities in Japan to Korea. The facilities should support the greentourism that leads to the active cultural exchange between urban and rural areas. The required specific facilities are discussed in this paper. For newly developed facilities, restaurants, specialty stores, and hotels may be effective facilities for the greentourism. The design for the entire greentourism facilities should consider, for the development of the area, the several kinds of required functions of the greentourism, such as the travel guide center, the marketing center, the information center, the business center, the human resources center, and the environment conservation center.

  • PDF

A evaluation and countermeasure for blast-induced vibration of micro electronic production facility based on experimental method (실험적 방법에 의한 발파작업으로 기인하는 인접 초정밀 생산장비 FAB에 미치는 진동 영향성 평가 및 제어대책)

  • Son, Sung-Wan;Park, Sang-Gon;Lee, Hong-Ki;Chun, Jong-Kun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.875-878
    • /
    • 2006
  • In the case of a vibration sensitive equipment, it require a vibration free environment to provide its proper function, therefore, it is very important to predict precisely vibration environment of microelectronics production facility due to adjacent blast work. However, it is not easy to evaluate a quantitative vibration response of structure due blast because it can be determined by the characteristics of vibration sources, propagation through rock and soil and dynamic properties of building. In this paper, vibration influence evaluation of micro-electronic Production building induced from adjacent blast activity was performed by real measurement data obtained on ground and structure at same time. And blast vibration allowable limit on ground was supposed by measurement data analysis in order to avoid operation error of precision equipments

  • PDF

Research Integrated Change Process for Configuration Management of Construction Nuclear Power Plant (건설원전 형상관리를 위한 통합변경프로세스 연구)

  • Park, Youjin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.231-232
    • /
    • 2016
  • Configuration Management (CM) is a process of identifying and documenting the characteristics of a Structures, Systems and Components (SSCs), and of ensuring that changes to these characteristics are properly assessed, approved, issued, implemented and verified. There are requirement management, change control, facility configuration information management for CM activities. In order to improve safety of Nuclear Power Plant(NPP), it is necessary to manage change item systematically. Existing CM concept is focused on the NPP in operation. On the other hand, NPP under construction is difficult to efficiently manage the change because of different change process from varoius stake-holders. This research considers method of consolidation change process for NPP to ensure that approved changes are accurately reflected in the design requirements, facility configuration information, and the physical configuration.

  • PDF

Important Radionuclides and Their Sensitivity for Ground water Pathway of a Hypothetical Near-Surface Disposal Facility

  • Park, J. W.;K. Chang;Kim, C. L.
    • Nuclear Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.156-165
    • /
    • 2001
  • A radiological safety assessment was performed for a hypothetical near-surface radioactive waste repository as a simple screening calculation to identify important nuclides and to provide insights on the data needs for a successful demonstration of compliance. Individual effective doses were calculated for a conservative ground water pathway scenario considering well drilling near the site boundary. Sensitivity of resulting ingestion dose to input parameter values was also analyzed using Monte Carlo sampling. Considering peak dose rate and assessment time scale, C-14 and T-129 were identified as important nuclides and U-235 and U-238 as potentially important nuclides. For C-14, the dose was most sensitive to Darcy velocity in aquifer The distribution coefficient showed high degree of sensitivity for I-129 release.

  • PDF

A Study on Digital Signal Content System for Facility Management (시설 관리용 디지털 신호 컨텐츠 시스템 연구)

  • Park, Kyeongmo;Ahn, Byeong-Tae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.1030-1032
    • /
    • 2015
  • In this paper, we developed a system that output and service using vairous contents with the inspection and management industry facilities in the operating system based on wireless network. This system can output to the display device at the same time, work management and a variety of content to the inspection facilities. And it outputs received contents of the advertising service provider in real-time. Therefore, this system support real-time facility management and various contents in the building at the same time.

  • PDF

Improvement Plan of Educational Facilities Maintenance based on Space Level (교육환경개선사업 공간단위 업무프로세스 개선방안)

  • Bae, Chang-Joon;Park, Sang-Hun;Cho, Dong-Hyun;Koo, Kyo-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.72-73
    • /
    • 2019
  • As the physical functions of school buildings and the changes in the functions of educational facilities due to social change are increasing, the demand for fundamental and long-term measures for the maintenance of educational facilities is expanding. However, depending on the function of the facility, the maintenance work has been carried out only when it is directly related to the safety problem, or when the request of the school facility manager is requested, rather than supporting preventive maintenance. In this study, we investigate the maintenance process of educational facilities and propose a method to manage the maintenance process of the educational facilities in the unit of space for establishing an efficient maintenance management system.

  • PDF

A Study on the Adhesion Performance of Solid Forming Angle at Fiber Panel in the Water Supply Facility (수처리 시설물에 적용되는 섬유패널 배면부의 입체 성형 각도에 따른 부착 성능 연구)

  • Youn, Joon-No;Park, Wan-Goo;Choi, Su-Young;Kim, Dong-Bum;Kim, Byoung-Il;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.171-172
    • /
    • 2018
  • The purpose of this study is to confirm the adhesion performance of the three - dimensional forming fiber panels by the dimensional forming angle. As a result of applying the three dimensional surface shape to the back side of the fiber panel and testing the adhesion strength by the three dimensional forming angle, it was confirmed that the bonding strength of the specimens to which the dimensional molding was applied was higher than that of the non dimensional molding. In addition, the highest adhesion strength was confirmed in a specimen having a three-dimensional forming angle of 70 °.

  • PDF

MASW FOR QUANTIFYING CHANGE IN SHEAR WAVE VELOCITY AFTER DEEP DYNAMIC COMPACTION AT A SOIL SITE

  • ChoonB.Park;RichardD.Miller
    • Journal of the Korean Geophysical Society
    • /
    • v.6 no.4
    • /
    • pp.245-259
    • /
    • 2003
  • Two multichannel analysis of surface wave (MASW) surveys were conducted over a soil site in Tacoma Water's Green River Facility, Washington, where construction of a chemical treatment facility had been planned. The purpose of the surveys was to compare soil stiffness characterized by shear-velocity (Vs) distribution before and after Deep Dynamic Compaction (DDC) operation that was designed to improve the soil stiffness. Site soil consisted of very heterogeneous gravel and cobbles in a sand-and-silt matrix. Results from each survey are represented by two 2-D Vs maps delineating Vs variation of soil below the surveyed lines. One map was constructed from those dispersion curves that were analyzed with a significant amount of subjective judgment involved, whereas the other map was constructed from those dispersion curves analyzed with as much objective information as possible. Comparison of 2-D Vs maps indicates that Vs actually decreased after the DDC operations, possibly due to the loss (or reduction) of cohesive bonding between soil particles caused by the compaction operations.

  • PDF