• Title/Summary/Keyword: Park cooling

Search Result 1,834, Processing Time 0.029 seconds

A Case Study on Fuel Supply and Cooling Systems of High-Speed Vehicles (고속 비행체 연료공급 및 냉각계통 사례분석)

  • Choi, Seyoung;Park, Sooyong;Choi, Hyunkyung;Jun, Pilsun;Park, Jeongbae
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.21 no.2
    • /
    • pp.1-6
    • /
    • 2013
  • In high-speed vehicle, selection of fuel, configuration of components and cooling system are required to solve the heating issue by aerodynamic heating and inner combustion process. This subsystem consists of fuel tank, supply pump, various control valve, heat exchanger, including reactor, connecting line, adiabatic structures and insulations. In this paper, applicable fuel property is considered at flight characteristic of hypersonic vehicles. In this regard, current state of fuel/cooling system technology is identified.

Cooling System with Nanofluidic Loop Thermosyphon (나노유체 루프형 열사이폰을 이용한 냉각장치)

  • Park Jong-Chan;Lim Taek-Kyu;Lee Chung-Gu;Shin Dong-Ryun;Park Gi-Ho;Rhi Seok-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.3 s.246
    • /
    • pp.246-254
    • /
    • 2006
  • The present study shows the experimental and modeling results of the cooling system using nanofludic loop thermosyphon. the experimental results show that nanofluid is not effective for small scale cooling system. The heat transfer performance is not much improved with the current small scale loop system comparing with the convectional water based loop system. In this study, various effects of nanofluids such as the concentration, the md of particle, host fluid, and heat capacity and so on were investigated. With nanofluid as the working fluid, the flow instability was improved at a certain concentration.

Development and Test of a Cooling System for a 154 kV Superconducting Fault Current Limiter

  • Kim, Heesun;Han, Young Hee;Yang, Seong-Eun;Yu, Seung-Duck;Park, Byung Jun;Park, Kijun;Yoo, Jaeun;Kim, Hye-Rim;In, Sehwan;Hong, Yong Joo;Yeom, Hankil
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.141-144
    • /
    • 2015
  • The superconducting fault current limiter (SFCL) is an electric power device that limits the fault current immediately in a power grid. Korea Electric Power Corporation (KEPCO) has been developing a 154 kV, 2 kA SFCL since 2011 to protect power grids from increasing fault current and improve the stability and quality of electric power. This SFCL adopts 2G YBCO wires and operates at 71 K and 5 bars. In this paper, a cooling system for the 154 kV SFCL and its cooling test results are reported. This cooling system uses a Stirling-type cooler to make sub-cooled liquid nitrogen ($LN_2$), which cools the superconductor modules of the SFCL. The $LN_2$ is circulated between the cooler and the cryostat that contains superconductor modules. The $LN_2$ also plays the role of a high voltage insulator between the modules and the cryostat, so the pressure was maintained at 5 bars for high insulation performance. After installation in a test site, the cooling characteristics of the system were tested. In this operation test, some important data were measured such as temperature distribution in $LN_2$, pressure change, performance of the heat exchanger, and cooling capacity of the total system. Consequently, the results indicate that the cooling system operates well as designed.

Thermal Flow Analysis of Vehicle Engine Cooling System

  • Park, Kyoung-Suk;Won, Jong-Phil;Heo, Hyung-Seok
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.7
    • /
    • pp.975-985
    • /
    • 2002
  • This paper deals with theoretical model developed for analyzing the heat transfer of automotive cooling systems. The model has a modular structure which links various cooling system submodels. From the model, heat transfer rate of automotive cooling systems can be predicted, providing useful information at the early stages of the design and development. The aim of the study is to develop a simulation program for automotive cooling system analysis and a performance analysis program for analyzing heat exchanger. Heat release rate from combustion gas to coolant through the cylinder wall in engine cylinder was analysed by using an engine cycle simulation program. In this paper, details of each submodel are described together with the overall structure of the vehicle model.

A Numerical Analysis on the Characteristics of Flow in the 20 MeV DTL Cooling System (20 MeV DTL 냉각계통의 유동 특성에 관한 수치해석)

  • Kim, Kyung-Ryul;Park, Jun;Kwon, Sei-Sin;Kim, Hyung-Gyun;Kim, Hee-Sub;Hwang, Woon-Ha;Yoon, Jong-Cheol
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2907-2912
    • /
    • 2007
  • The cooling water system for the PEFP 20 MeV proton accelerator was established and tested to obtain the precise resonance frequency of DTL through the temperature control of cooling water. The water temperature in the main flow loop was manipulated by adjusting the proportion of hot water returning from the DTL structures through the heat exchanger loop. Due to low duty factor operation and insufficient cooling loop installation of the DTL tanks, the manual mode operation was applied to maintain the DTL temperatures close to their resonance temperatures. The optimized process conditions with flow balancing and pressure drop in the DTL cooling systems are reported.

  • PDF

A Study on Heat Transfer Characteristics of Automotive Engine Cooling Control System (자동차용 엔진 냉각시스템의 열전달 특성에 관한 연구)

  • Park, Kyoung-Suk;Won, Jong-Pil;Jung, Dong-Hwa
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.8
    • /
    • pp.1183-1194
    • /
    • 1998
  • This paper describes a theoretical model developed for analyzing the heat transfer of automotive cooling systems. From the model, heat transfer rate of automotive cooling systems can be predicted, providing useful information at the early stages of the design and development. The aim of the study is to develop a simulation program for automotive cooling system analysis and a performance analysis program for analyzing heat exchanger. Heat release rate from combustion gas to coolant through cylinder wall in engine cylinder was analyzed by using a two zone combustion model. This paper studied how cooling condition would affect engine heat release rate and measured temperature distribution of coolant in water jacket.

A Study on efficiency improvement of BLDC motor for radiator cooling fan (자동차 Cooling Fan용 고효율 BLDC모터의 호율개선에 대한 연구)

  • Ahn, Young-Il;Park, Chang-Soon
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.44-46
    • /
    • 2003
  • Nowaday it is trend to be one cooling radiator and cooling fan from separate engine radiator and air condition radiator in cars. For the cooling fan is developed a electrical motor which is limited in size. The motor should be working in silence and have no electromagnetic Problem and high efficiency. In this paper will be proposed some parameters for improvement of the efficiency of a BLDC motor which is developed for the cooling system after theoretical and experimental investigation.

  • PDF

Structural Optimization By Adaptive Simulated Annealing's Cooling Schedule Change (어댑티브 시뮬레이티드 어넬링의 냉각스케줄에 따른 구조최적설계)

  • Jung, Suk-Hoon;Park, Jung-Sun
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1436-1441
    • /
    • 2003
  • Recently, simulated annealing algorithms have widely been applied to many structural optimization problems. In this paper, simulated annealing, boltzmann annealing, fast annealing and adaptive simulated annealing are applied to optimization of truss structures for improvement quality of objective function and number of function evaluation. These algorithms are classified by cooling schedule. The authors have changed parameters of ASA's cooling schedule and the influence of cooling schedule parameters on structural optimization obtained is discussed. In addition, cooling schedule of BA and ASA mixed is applied to 10 bar-truss structure.

  • PDF

The Conceptual Design of Primary Cooling System for an Advanced Research Reactor (수출전략형 연구로의 1차 냉각계통 개념설계)

  • Park, Yong-Chul;Kim, Kyung-Ryun
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.503-508
    • /
    • 2005
  • An advanced Research Reactor (ARR) consists of an open-tank-type reactor assembly within a light water pool and generates thermal power of 20 MW. The thermal power is including a fission heat in the core, a fuel generated heat temporary stored in the pool, a circulating pumps generated heat and a neutron reflecting heat in the reflector vessel of the reactor. In order to remove the heat load, the primary cooling system will be installed. In this study, the conceptual design of the primary cooling system has been carried out using a design methodology of HANARO within a permissible range of safety. As results, it has been established that the conceptual design of the primary cooling system including design requirements, performance requirements, design restrictions, system descriptions and system operation to maintain the system functions.

  • PDF

Thermal Performance of Cooling System for a Laptop Computer Using a Boiling Enhancement Microstructure (비등 촉진 마이크로 구조물을 이용한 휴대용 컴퓨터 냉각시스템의 열성능에 관한 연구)

  • Cho, N.H.;Jeong, W.Y.;Park, S.H.
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2043-2052
    • /
    • 2008
  • The increasing heat generation rates in CPU of notebook computers motivate a research on cooling technologies with low thermal resistance. This paper develops a closed-loop two-phase cooling system using a micropump to circulate a dielectric liquid(PF5060). The cooling system consists of an evaporator containing a boiling enhancement microstructure connected to a condenser with mini fans providing external forced convection. The cooling system is characterized by a parametric study which determines the effects of volume fill ratio of coolant, existence of a boiling enhancement microstructure and pump flow rates on thermal performance of the closed loop. Experimental data shows the optimal parametric values which can dissipate 33.9W with a film heater maintained at $95^{\circ}C$.

  • PDF