• 제목/요약/키워드: Parameters Sensitivity

검색결과 2,066건 처리시간 0.025초

Nonlinear vibration analysis of fluid-conveying cantilever graphene platelet reinforced pipe

  • Bashar Mahmood Ali;Mehmet AKKAS;Aybaba HANCERLIOGULLARI;Nasrin Bohlooli
    • Steel and Composite Structures
    • /
    • 제50권2호
    • /
    • pp.201-216
    • /
    • 2024
  • This paper is motivated by the lack of studies relating to vibration and nonlinear resonance of fluid-conveying cantilever porous GPLR pipes with fractional viscoelastic model resting on nonlinear foundations. A dynamical model of cantilever porous Graphene Platelet Reinforced (GPLR) pipes conveying fluid and resting on nonlinear foundation is proposed, and the vibration, natural frequencies and primary resonant of such system are explored. The pipe body is considered to be composed of GPLR viscoelastic polymeric pipe with porosity in which Halpin-Tsai scheme in conjunction with fractional viscoelastic model is used to govern the construction relation of the nanocomposite pipe. Three different porosity distributions through the pipe thickness are introduced. The harmonic concentrated force is also applied on pipe and excitation frequency is close to the first natural frequency. The governing equation for transverse motion of the pipe is derived by the Hamilton principle and then discretized by the Galerkin procedure. In order to obtain the frequency-response equation, the differential equation is solved with the assumption of small displacement, damping coefficient, and excitation amplitude by the multiple scale method. A parametric sensitivity analysis is carried out to reveal the influence of different parameters, such as nanocomposite pipe properties, fluid velocity and nonlinear viscoelastic foundation coefficients, on the primary resonance and linear natural frequency. Results indicate that the GPLs weight fraction porosity coefficient, fractional derivative order and the retardation time have substantial influences on the dynamic response of the system.

Veritrek 소프트웨어를 활용한 그라파이트시트 기반 극저온 냉각기 열 제어 시스템 최적설계 (Optimal Design of Graphite Sheet based Cryogenic Cooler Thermal Control System using Veritrek Software)

  • 채봉건;김혜인;오현웅
    • 항공우주시스템공학회지
    • /
    • 제18권2호
    • /
    • pp.71-78
    • /
    • 2024
  • 초기 열설계 과정의 경우 복잡한 궤도 열 환경 조건에서 다양한 설계 변수에 따른 열적 영향성 판단을 해야 하므로, 열 설계/분석에 많은 시간이 소요된다. 따라서, 초기 설계 단계에서 시간을 효율적으로 단축시키기 위해서는 최적의 설계 변수 도출과 이에 따른 온도 예측이 신속히 이루어져야 한다. 상기 문제점에 기인하여 차수축소모델을 활용한 최적 설계 전문 소프트웨어인 Veritrek이 2018년에 출시되었다. 본 논문에서는 Veritrek 소프트웨어를 활용하여 그라파이트시트 기반 냉각기 열 제어 시스템에 대해 차수축소모델 구축과 민감도 분석, 최적 설계 분석을 수행하여 냉각기의 허용온도를 만족할 수 있는 그라파이트시트의 적층 수, 방열판 면적 및 두께에 대한 최적설계 수치를 도출하였다.

International case study comparing PSA modeling approaches for nuclear digital I&C - OECD/NEA task DIGMAP

  • Markus Porthin;Sung-Min Shin;Richard Quatrain;Tero Tyrvainen;Jiri Sedlak;Hans Brinkman;Christian Muller;Paolo Picca;Milan Jaros;Venkat Natarajan;Ewgenij Piljugin;Jeanne Demgne
    • Nuclear Engineering and Technology
    • /
    • 제55권12호
    • /
    • pp.4367-4381
    • /
    • 2023
  • Nuclear power plants are increasingly being equipped with digital I&C systems. Although some probabilistic safety assessment (PSA) models for the digital I&C of nuclear power plants have been constructed, there is currently no specific internationally agreed guidance for their modeling. This paper presents an initiative by the OECD Nuclear Energy Agency called "Digital I&C PSA - Comparative application of DIGital I&C Modelling Approaches for PSA (DIGMAP)", which aimed to advance the field towards practical and defendable modeling principles. The task, carried out in 2017-2021, used a simplified description of a plant focusing on the digital I&C systems important to safety, for which the participating organizations independently developed their own PSA models. Through comparison of the PSA models, sensitivity analyses as well as observations throughout the whole activity, both qualitative and quantitative lessons were learned. These include insights on failure behavior of digital I&C systems, experience from models with different levels of abstraction, benefits from benchmarking as well as major contributors to the core damage frequency and those with minor effect. The study also highlighted the challenges with modeling of large common cause component groups and the difficulties associated with estimation of key software and common cause failure parameters.

Diffusion-weighted Magnetic Resonance Imaging for Predicting Response to Chemoradiation Therapy for Head and Neck Squamous Cell Carcinoma: A Systematic Review

  • Sae Rom Chung;Young Jun Choi;Chong Hyun Suh;Jeong Hyun Lee;Jung Hwan Baek
    • Korean Journal of Radiology
    • /
    • 제20권4호
    • /
    • pp.649-661
    • /
    • 2019
  • Objective: To systematically review the evaluation of the diagnostic accuracy of pre-treatment apparent diffusion coefficient (ADC) and change in ADC during the intra- or post-treatment period, for the prediction of locoregional failure in patients with head and neck squamous cell carcinoma (HNSCC). Materials and Methods: Ovid-MEDLINE and Embase databases were searched up to September 8, 2018, for studies on the use of diffusion-weighted magnetic resonance imaging for the prediction of locoregional treatment response in patients with HNSCC treated with chemoradiation or radiation therapy. Risk of bias was assessed by using the Quality Assessment Tool for Diagnostic Accuracy Studies-2. Results: Twelve studies were included in the systematic review, and diagnostic accuracy assessment was performed using seven studies. High pre-treatment ADC showed inconsistent results with the tendency for locoregional failure, whereas all studies evaluating changes in ADC showed consistent results of a lower rise in ADC in patients with locoregional failure compared to those with locoregional control. The sensitivities and specificities of pre-treatment ADC and change in ADC for predicting locoregional failure were relatively high (range: 50-100% and 79-96%, 75-100% and 69-95%, respectively). Meta-analytic pooling was not performed due to the apparent heterogeneity in these values. Conclusion: High pre-treatment ADC and low rise in early intra-treatment or post-treatment ADC with chemoradiation, could be indicators of locoregional failure in patients with HNSCC. However, as the studies are few, heterogeneous, and at high risk for bias, the sensitivity and specificity of these parameters for predicting the treatment response are yet to be determined.

Accuracy of administrative claim data for gastric adenoma after endoscopic resection

  • Ga-Yeong Shin;Hyun Ho Choi;Jae Myung Park;Sang Yoon Kim;Jun Young Park;Donghoon Kang;Yu Kyung Cho;Sung Soo Kim;Myung-Gyu Choi
    • Clinical Endoscopy
    • /
    • 제56권3호
    • /
    • pp.325-332
    • /
    • 2023
  • Background/Aims: Administrative databases provide valuable information for large-cohort studies. This study aimed to evaluate the diagnostic accuracy of an administrative database for resected gastric adenomas. Methods: Data of patients who underwent endoscopic resection for benign gastric lesions were collected from three hospitals. Gastric adenoma cases were identified in the hospital database using International Classification of Diseases (ICD) 10-codes. The non-adenoma group included patients without gastric adenoma codes. The diagnostic accuracy for gastric adenoma was analyzed based on the pathological reports of the resected specimen. Results: Among 5,095 endoscopic resections with codes for benign gastric lesions, 3,909 patients were included in the analysis. Among them, 2,831 and 1,078 patients were allocated to the adenoma and non-adenoma groups, respectively. Regarding the overall diagnosis of gastric adenoma with ICD-10 codes, the sensitivity, specificity, positive predictive value, and negative predictive value were 98.7%, 88.5%, 95.2%, and 96.8%, respectively. There were no significant differences in these parameters between the tertiary and secondary centers. Conclusions: Administrative codes of gastric adenoma, according to ICD-10 codes, showed good accuracy and can serve as a useful tool to study prognosis of these patients in real-world data studies in the future.

에어로졸 광학변수가 대기복사가열률 산정에 미치는 민감도 분석 (Sensitivity of Aerosol Optical Parameters on the Atmospheric Radiative Heating Rate)

  • 김상우;최인진;윤순창;김유미
    • 대기
    • /
    • 제23권1호
    • /
    • pp.85-92
    • /
    • 2013
  • 2001년 4월 제주 고산기후관측소에서 AERONET sun/sky radiometer와 MPL을 통해 관측된 에어로졸 광학적 두께, 단산란 알베도, 비대칭 변수, 에어로졸 소산계수 프로파일 등을 대기복사모델의 입력 자료로 이용하여 대기가열효과를 산정하고, 이들 광학변수가 대기복사가열률에 미치는 영향을 분석하였다. 본 연구에서는 NCAR Climate Community Model (CCM-3.6)에 포함되어 있는 복사 모듈인 Column Radiation Model (CRM-2.1.2)을 연직 54층으로, AERONET sun/sky radiometer로부터 관측된 4 파장 (440, 670, 870, 그리고 1020 nm)에서의 관측 자료를 19개의 파장에서 계산 가능하도록 수정하였다. 에어로졸층이 존재하지 않은 맑은 날 (4월 14일과 16일)은 지표면과 대기상단에서의 에어로졸 직접복사강제력이 각각 $-20{\sim}-25\;W\;m^{-2}$$-10{\sim}-15\;W\;m^{-2}$로, 대기 중 흡수는 $+10{\sim}+15\;W\;m^{-2}$였다. 에어로졸층이 관측된 4월 15일과 4월 17~18일의 경우 지표면, 대기, 대기상단의 에어로졸 복사강제력이 맑은 날에 비해 3~4배 정도 크게 나타났다. 4월 14일과 16일에의 대기복사가열률 (${\Delta}H$)는 $1{\sim}2\;K\;day^{-1}$ 범위에서 산출되었으며, 4월 15일과 4월 17~18일에는 MPL 관측에서 보여지는 에어로졸층에서의 ${\Delta}H$${\Delta}H_{aerosol}$가 각각 $3\;K\;day^{-1}$ 이상과 $1{\sim}3\;K\;day^{-1}$ 범위에서 산정되었다. 에어로졸 광학적 두께와 비대칭 변수의 변화에 따른 에어로졸층의 ${\Delta}H$ 변화는 미미하였으나, 단산란 알베도의 10% 변화는 지표면과 대기상단에서의 에어로졸 직접복사강제력의 30%, 대기복사강제력의 약 60%, 그리고 에어로졸층 ${\Delta}H$의 약 35% 변화를 유발하였다. 이는 에어로졸 광학적 두께 10% 변화와 비교하여 대기흡수 또는 에어로졸층의 가열 및 냉각 효과가 6배 가량 큰 결과로, 태양복사를 효과적으로 잘 흡수하는 에어로졸의 양에 의해 대기 가열 또는 ${\Delta}H$가 크게 좌우됨을 의미한다. 2001년 4월부터 2008년 3월까지 제주 고산기후관측소에서의 AERONET sun/sky radiometer 관측 자료를 이용하여 계산한 ${\Delta}H$${\Delta}H_{aerosol}$의 월변화를 보면, ${\Delta}H$는 4~8월 사이에 대류권 하부에서 약 $1.0\;K\;day^{-1}$ 이상으로 뚜렷하게 나타났으나, ${\Delta}H_{aerosol}$의 경우 2월부터 6월까지 고도 2 km 이하에서 약 $0.8\;K\;day^{-1}$ 이하의 범위에서 나타나는데, 이는 대부분의 에어로졸이 지표면 부근의 대기경계층에 존재하며, 봄철 황사와 오염 에어로졸의 증가에 의한 영향으로 판단된다.

두층 섬광결정과 위치민감형광전자증배관을 이용한 소동물 양전자방출단층촬영기 개발: 기초실험 결과 (Development of a Small Animal Positron Emission Tomography Using Dual-layer Phoswich Detector and Position Sensitive Photomultiplier Tube: Preliminary Results)

  • 정명환;최용;정용현;송태용;정진호;홍기조;민병준;최연성;이경한;김병태
    • 대한핵의학회지
    • /
    • 제38권5호
    • /
    • pp.338-343
    • /
    • 2004
  • 목적: 이 연구의 목적은 두층 섬광결정을 사용하여 PET 기기 시야 외곽에서 발생하는 영상 왜곡현상을 최소화하는 고 민감도, 고 분해능의 소동물 PET 시스템을 개발하는 것이다. 대상 및 방법: GATE (Geant4 Application for Tomographic Emission) 시뮬레이션 프로그램을 사용하여 시스템을 모사하였고 시스템 성능을 예측하였으며 시뮬레이션에서 도출한 파라미터를 기준으로 시스템을 설계 제작 하였다. 두층 섬광결정은 Lutetium Oxyorthosilicate (LSO)와 Lutetium-Yttrium Aluminate-Perovskite (LuYAP)으로 구성하였다. 섬광결정의 각 픽셀크기는 $2mm{\times}2mm{\times}8mm$이며 $8{\times}8$로 배열하여 두층 섬광결정으로 구성하였다. 두층 섬광결정 배열을 위치민감형 광전자증배관(Position Sensitive Photomultiplier Tube: PSPMT)과 결합하여 한 개의 검출기를 구성하였으며, 총 16개 검출기를 지름 10 cm, 유효시야 8 cm인 원형으로 배열하였다. 검출기로부터 출력된 데이터는 소켓, 디코더, ADC, FPGA회로를 거쳐 전 처리 컴퓨터에 입력되고 마스터 컴퓨터에 저장 되도록 하였다. 결과: 시스템 개발의 초기 연구로 한쌍 검출기만 사용하여 단층영상을 획득하고 민감도와 공간분해능을 측정하였다. 점선원을 시야 중앙에 위치했을 때 공간분해능은 2.3 mm FWHM이고, 민감도는 10.9 $cps/{\mu}Ci$이었다. 결론: 구축한 시스템을 사용하여 선원의 위치와 모양변화를 정확하게 측정한 사이노그램과 PET 영상을 획득할 수 있었다. 이 연구는 고 분해능 고 민감도 PET 시스템 개발의 초기연구로, 소형 원형 PET 시스템 개발 가능성을 보여준다.lamate을 이용하여 측정한 사구체 여과율과 통계적으로 유의한 상관 관계를 보이지 않았다. 결론: Gates 방법을 이용한 사구체 여과율 측정에서 배후 방사능 관심 영역은 신장의 상방과 양측 신장사이, 즉 혈액 풀 방사능이 많이 분포하는 부위에 설정하는 것이 I-125-iothalamate을 이용한 사구체 여과율과 가장 높은 상관 관계를 보였고, 신장 깊이가 깊지 않은 2군에서 두 사구체 여과율은 더 높은 상관 관계를 보였다.7%$, 25분일 때 $95{\pm}12%$, 40분일 때 $98{\pm}3%$로 통계학적으로 유의한 차이는 없었다(p>0.05). 항응고제 종류에 따른 결합효율은 헤파린을 사용한 경우 $89{\pm}20%$, CPDA를 사용한 경우 $97{\pm}6%$, ACD를 사용한 경우 $98{\pm}4%$로 CPDA와ACD를 사용한 경우에 유의하게 높은 결합효율을 보였다(p<0.001). 결론: 변형 체내 표지법으로 적혈구를 표지시 우수한 결합효율을 유지하기 위해서는 채취하는 혈액의 양은 3 mL 이상, 배양시간은 10분 이상(10분-40분), 항응고제는 ACD나 CPDA tinning 시간은 20분 이상(20-35분)을 유지하고, 가능한 rotating invertor를 사용하는 것이 좋을 것으로 생각된다.KC $\varepsilon$이 K562(Adr)세포에서 많이 발현되었으나, K562와 K562(Adr)세포에서는 verapamil처리에 따른 PKC 아형의 변화는 없었다. 결론: Verapamil은 암세포의 종류에 따라 MIBI와 TF의 섭취를 감소시켰고, 고용량에는 MDR세포의 섭취도 감소시켰으며 이러한 현상은 세포독성 이나 PKC효소 아형과는 관련이 없었다. 그러므로 MDR의 진단시 verapamil을

Philips ARGUS 감마카메라와 바늘구멍조준기를 이용한 소동물 SPECT 시스템의 개발 및 성능 평가 (Development and Performance Evaluation of an Animal SPECT System Using Philips ARGUS Gamma Camera and Pinhole Collimator)

  • 김중현;이재성;김진수;이병일;김수미;정인순;김유경;이원우;김상은;정준기;이명철;이동수
    • 대한핵의학회지
    • /
    • 제39권6호
    • /
    • pp.445-455
    • /
    • 2005
  • 목적 : 임상용 Philips ARGUS 감마카메라와 특별 제작한 작은 구경의 바늘구멍조준기를 이용하여 animal SPECT를 개발하였다. 본 연구에서는 이 시스템의 물리적인 성능을 평가하고 소동물 실험에 적합한지를 평가하였다. 대상 및 방법: 스텝 모터와 이를 제어할 수 있는 소프트웨어를 이용한 피사체 회전장치를 개발하였다. 작은 입구(0.5, 1.0, 2.0 mm)의 바늘구멍조준기를 제작하였고 평면 공간해상도, 민감도, 단층촬영해상도 등을 포함한 물리적 성능을 모든 입구 크기에 대해 실험하였다. 조준기 입구로부터의 거리에 따른 사용 가능한 시야를 측정하기 위하여, 같은 간격만큼 떨어진 여러 선선원의 영상을 얻고 영상의 시야 내에서 보이는 선 영상의 개수를 이용하여 사용 가능한 시야를 측정하였다. 시야의 정중앙에 놓인 내경 0.5 mm, 길이 12 mm의 Tc-99m 선선원을 이용하여 거리에 따른 평면 공간 해상도를 측정하였다. 전체 반값두께를 'mm'단위로 얻기 위한 환산인자를 평면 영상에서의 두개의 서로 떨어진 선선원으로부터 계산하였다. 시스템 민감도를 측정하기 위하여 내경 1.0 mm의 Tc-99m 점선원을 사용하였다. 또한 냉소반점 모형과 열소반점 모형, 그리고 [I-123] FP-CIT를 정맥내 주사한 흰쥐의 뇌 영상의 SPECT 영상을 얻었고 여과후역투사 방법으로 재구성하였다. 결과: 사용 가능한 시야의 크기는 조준기의 초점으로부터의 거리에 비례하였고 이들의 관계는 선형 함수로 근사되었다(y=1.4x+0.5). 3 cm에서 1.0 mm 조준기로 측정한 민감도와 평면해상도는 각각 71 cps/MBq과 1.24 mm이었다. 1.0 mm 바늘구멍조준기에 대하여 [I-123] FP-CIT를 이용한 흰쥐의 뇌 SPECT 영상에서 각 반구의 줄무늬체 도파민 전달체 분포가 잘 구분되어 보였다. 결론: Philips ARGUS 스캐너와 작은 구경의 바늘구멍조준기로 개발한 새로운 소동물 SPECT 시스템이 소동물 영상을 얻는데 충분한 성능을 가짐을 입증하였다.

UV-VIS 초분광 위성센서 모의복사휘도를 활용한 다양한 관측환경에서의 에어로솔 유효고도에 대한 O4 대기질량인자 민감도 조사 (Investigation of O4 Air Mass Factor Sensitivity to Aerosol Peak Height Using UV-VIS Hyperspectral Synthetic Radiance in Various Measurement Conditions)

  • 최원이;이한림;최철웅;이양원;노영민
    • 대한원격탐사학회지
    • /
    • 제36권2_1호
    • /
    • pp.155-165
    • /
    • 2020
  • 본 연구에서는 복사전달모델을 사용하여 다양한 변수환경(파장 (340 nm, 477 nm), 에어로솔 종류(스모크, 황사, 황산염), AOD (aerosol optical depth), 지표면 반사도, 관측기하)에 따라 에어로솔 유효 고도(aerosol peak height; APH)에 대한 O4 대기질량인자(air mass factor; AMF)의 민감도를 조사하였다. 전반적으로, 477 nm의 O4 AMF 가 340 nm 보다 APH에 대한 민감도가 크고 안정적으로 산출 가능한 것으로 확인하였다. AOD가 높을 때 APH에 대한 O4 AMF의 민감도가 커지는 것을 확인하였다. 477 nm에서는 340 nm 보다 지표면 반사도의 영향이 큰 것으로 나타났다. 태양천정각 증가에 따라 340 nm에서의 O4 AMF가 감소하는 추세를 발견하였으며, 이러한 경향은 태양천정각 40°인 환경에서 높은 Rayleigh 및 Mie 산란에 의한 장벽효과로 인해 O4 흡수가 발생하는 광경로 길이가 줄어들기 때문인 것으로 사료된다. 477 nm에서는 태양천정각이 증가함에 따라 Rayleigh 및 Mie 산란에 의한 다중산란이 일부 발생하여 O4 AMF가 비선형함수 형태로 증가하는 경향을 보였다. 마지막으로, AOD의 불확실성이 APH 산출오차에 미치는 영향을 조사하였다. 황산염 타입에 대한 APH 산출 시, AOD의 불확실성으로 인한APH 산출오차가 다른 에어로솔 타입보다 크게 나타났으며, 황사의 경우 AOD 불확실성에 대한 APH 산출오차에 대한 영향이 미미하게 나타났다. 이러한 결과는 각 에어로솔 타입의 흡수 산란 특성이 다양하기 때문에, 에어로솔 타입이 APH 산출 오차에 영향을 미칠 수 있음을 의미한다.

특발성변비 환아에서의 직장항문압측정검사 (Anorectal Manometry in Idiopathic Constipation in Children)

  • 백남선;서정기
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • 제2권1호
    • /
    • pp.30-39
    • /
    • 1999
  • 목적: 정상어린이, 변비 및 유분증이 있는 환아에서 직장항문압검사를 시행하여 이의 유용성을 알아보고자 하였다. 방법: 정상대조군 어린이 11명과 36명의 환아(특발성변비환아 20명, 유분증환아16명)에서 항문직장압검사를 시행하였다. 결과: 외괄약근압은 대조군에서($21.0{\pm}8.00$ mmHg) 단순 변비군($34.4{\pm}15.3$; p=0.028)이나 유분증군($33.8{\pm}15.2$ mmHg; p=0.028)과 비교하여 유의하게 낮았다. 내괄약근압도 대조군에서($30.0{\pm}14.57$ mmHg) 단순변비군($41.0{\pm}15.3$ mmHg, p=0.016)과 유분증군($49.3{\pm}13.6$, p=0.016)과 비교하여 의미있게 낮았다. 최소감각용적은 단순 변비군($54.2{\pm}35.9$ ml, p=0.002) 유분증군($73.6{\pm}33.5$ ml, p=0.002) 모두 대조군($11.4{\pm}4.52$ ml)보다 높은 수치를 나타내었다. 직장-항문 반사 역치는 단순변비군($17.1{\pm}8.75$ ml), 유분증군($13.2{\pm}11.1$ ml) 및 대조군($8.91{\pm}$ ml)에서 유의한 차이가 없었다(p=0.212). 또한 최소감각용적에서 직장항문반사역치를 뺀 값은 대조군($-1.00{\pm}6.99$ ml)에 비해 환아군($44.0{\pm}39.5$ ml)에서 의미있게(p=0.005) 높았다. PRRAIR는 세 군 간의 차이가 없었다(p=0.307). 결론: 위의 결과는 유분증환아 및 변비 환아에서 항문생리를 객관적인 수치로 표시하였을 때 정상 어린이와 차이가 있음을 보여주었고 환아의 치료 방침을 정하거나 변비의 객관적인 평가에 직장항문압검사가 유용하게 이용될수 있음을 보여주었다. 또한 유분증과 단순변비간에 여러수치의 차이가 없는 것은 일부를 제외하고는 변비와 유분증은 같은 병태생리를 갖고 있는 것을 나타내는 것이라 할 수 있다.

  • PDF