• Title/Summary/Keyword: Parameters Optimization

Search Result 3,253, Processing Time 0.03 seconds

Storage Assignment for Variables Considering Efficient Memory Access in Embedded System Design (임베디드 시스템 설계에서 효율적인 메모리 접근을 고려한 변수 저장 방법)

  • Choi Yoonseo;Kim Taewhan
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.32 no.2
    • /
    • pp.85-94
    • /
    • 2005
  • It has been reported and verified in many design experiences that a judicious utilization of the page and burst access modes supported by DRAMs contributes a great reduction in not only the DRAM access latency but also DRAM's energy consumption. Recently, researchers showed that a careful arrangement of data variables in memory directly leads to a maximum utilization of the page and burst access modes for the variable accesses, but unfortunately, found that the problems are not tractable, consequently, resorting to simple (e.g., greedy) heuristic solutions to the problems. In this parer, to improve the quality of existing solutions, we propose 0-1 ILP-based techniques which produce optimal or near-optimal solution depending on the formulation parameters. It is shown that the proposed techniques use on average 32.2%, l5.1% and 3.5% more page accesses, and 84.0%, 113.5% and 10.1% more burst accesses compared to OFU (the order of first use) and the technique in [l, 2] and the technique in [3], respectively.

Development of a CFD Program for Cold Gas Flow Analysis in a High Voltage Circuit Breaker Using CFD-CAD Integration (CFD-CAD 통합해석을 이용한 초고압 차단기 내부의 냉가스 유동해석 프로그램 개발)

  • Lee, Jong-Cheol;An, Hui-Seop;O, Il-Seong;Choe, Jong-Ung
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.5
    • /
    • pp.242-248
    • /
    • 2002
  • It is important to develop new effective technologies to increase the interruption capacity and to reduce the size of a UB(Gas Circuit Breakers). Major design parameters such as nozzle geometries and interrupting chamber dimensions affect the cooling of the arc and the breaking performance. But it is not easy to test real GCB model in practice as in theory. Therefore, a simulation tool based on a computational fluid dynamics(CFD) algorithm has been developed to facilitate an optimization of the interrupter. Special attention has been paid to the supersonic flow phenomena between contacts and the observation of hat-gas flow for estimating the breaking performance. However, there are many difficult problems in calculating the flow characteristics in a GCB such as shock wave and complex geometries, which may be either static or in relative motion. Although a number of mesh generation techniques are now available, the generation of meshes around complicated, multi-component geometries like a GCB is still a tedious and difficult task for the computational fluid dynamics. This paper presents the CFD program using CFB-CAD integration technique based on Cartesian cut-cell method, which could reduce researcher's efforts to generate the mesh and achieve the accurate representation of the geometry designed by a CAD tools.

Optimal Design of Fuzzy-Neural Networkd Structure Using HCM and Hybrid Identification Algorithm (HCM과 하이브리드 동정 알고리즘을 이용한 퍼지-뉴럴 네트워크 구조의 최적 설계)

  • Oh, Sung-Kwun;Park, Ho-Sung;Kim, Hyun-Ki
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.7
    • /
    • pp.339-349
    • /
    • 2001
  • This paper suggests an optimal identification method for complex and nonlinear system modeling that is based on Fuzzy-Neural Networks(FNN). The proposed Hybrid Identification Algorithm is based on Yamakawa's FNN and uses the simplified inference as fuzzy inference method and Error Back Propagation Algorithm as learning rule. In this paper, the FNN modeling implements parameter identification using HCM algorithm and hybrid structure combined with two types of optimization theories for nonlinear systems. We use a HCM(Hard C-Means) clustering algorithm to find initial apexes of membership function. The parameters such as apexes of membership functions, learning rates, and momentum coefficients are adjusted using hybrid algorithm. The proposed hybrid identification algorithm is carried out using both a genetic algorithm and the improved complex method. Also, an aggregated objective function(performance index) with weighting factor is introduced to achieve a sound balance between approximation and generalization abilities of the model. According to the selection and adjustment of a weighting factor of an aggregate objective function which depends on the number of data and a certain degree of nonlinearity(distribution of I/O data), we show that it is available and effective to design an optimal FNN model structure with mutual balance and dependency between approximation and generalization abilities. To evaluate the performance of the proposed model, we use the time series data for gas furnace, the data of sewage treatment process and traffic route choice process.

  • PDF

Analysis of fatty acid methyl ester in bio-liquid by hollow fiber-liquid phase microextraction

  • Choi, Minseon;Lee, Soyoung;Bae, Sunyoung
    • Analytical Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.174-181
    • /
    • 2017
  • Bio-liquid is a liquid by-product of the hydrothermal carbonization (HTC) reaction, converting wet biomass into solid hydrochar, bio-liquid, and bio-gas. Since bio-liquid contains various compounds, it requires efficient sampling method to extract the target compounds from bio-liquid. In this research, fatty acid methyl ester (FAME) in bio-liquid was extracted based on hollow fiber supported liquid phase microextraction (HF-LPME) and determined by Gas Chromatography-Flame Ionization Detector (GC-FID) and Gas Chromatography/Mass Spectrometry (GC/MS). The well-known major components of biodiesel, including methyl myristate, palmitate, methyl palmitoleate, methyl stearate, methyl oleate, and methyl linoleate had been selected as standard materials for FAME analysis using HF-LPME. Physicochemical properties of bio-liquid was measured that the acidity was 3.30 (${\pm}0.01$) and the moisture content was 100.84 (${\pm}3.02$)%. The optimization of HF-LPME method had been investigated by varying the experimental parameters such as extraction solvent, extraction time, stirring speed, and the length of HF at the fixed concentration of NaCl salt. As a result, optimal conditions of HF-LPME for FAMEs were; n-octanol for extraction solvent, 30 min for extraction time, 1200 rpm for stirring speed, 20 mm for the HF length, and 0.5 w/v% for the concentration of NaCl. Validation of HF-LPME was performed with limit of detection (LOD), limit of quantitation (LOQ), dynamic range, reproducibility, and recovery. The results obtained from this study indicated that HF-LPME was suitable for the preconcentration method and the quantitative analysis to characterize FAMEs in bio-liquid generated from food waste via HTC reaction.

Application of Optimal Design Method to Agent Discharge Flow Calculation of Gaseous Fire Extinguishing Systems (최적설계법을 응용한 가스계 소화설비의 약제방출량 산출)

  • Lee, Dong-Myung
    • Fire Science and Engineering
    • /
    • v.29 no.5
    • /
    • pp.51-56
    • /
    • 2015
  • In this study, optimal design methods were applied to the agent discharge flow of clean agent fire extinguishing systems. The methods combined optimal design theory and engineering theory for engineering analysis in a design program or coast savings in value engineering. Optimal design parameters were determined to optimize the agent discharge flow based on the design theory of the clean agent fire extinguishing systems and the theory of optimal design. The design factors were verified in regard to suitability for the performance of fire extinguishing systems. The results provide a foundation for optimal design method methods in other fire extinguishing systems. Optimization of the agent discharge flow of the discharge nozzle was confirmed by the constraints on the inner diameter of the discharge nozzle and the pipe, agent arrival time, flow, and pressure variation of the agent. The deviation of discharge pressure and agent time of the agent discharge nozzle were found to correlate with the pressure variation.

Optimization of bacterial urinary mutagenicity test (뇨 돌연변이 유발성 시험법 정립)

  • Jang, Mi;Shin, Han-Jae;Park, Chul-Hoon;Sohn, Hyung-Ok;Hyun, Hak-Chul
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.37 no.1
    • /
    • pp.18-24
    • /
    • 2015
  • Urinary mutagenicity is widely recognized as a useful biomarker for the assessment of mutagen exposure level in human. In this study, we optimized the several parameters affecting the activity of Urinary mutagenicity using highly sensitive mutation test(microsuspension assay) instead of the conventional Ames test. First of all, we chose YG1024 as a highly sensitive strain from three str ains of Salmonella typhimurium(TA98, TA100, YG1024) using r epr esentative mutation substances, such as Benzo[a]pyrene, 2-Aminonaphthalene, 2-amino-3-methyl-9H-pyrido[2,3-b]indole($MeA{\alpha}C$) and cigarette total particulate matter(TPM). And we established the several kinds of test conditions such as number of bacter ia, concentr ation of metabolic activation system and incubation time for the most sensitive reaction. Also, we optimized efficient pre-treatment method using commercial C18 column. As a r esults, this method was shown a aver age of 94 % recovery value and 13 % relative standard deviation. When we compared the Urinary mutagenicity between several participants, we confirmed that compar ative measurements were possible for different levels of urine mutagenicity. In conclusion, the optimized highly sensitive mutation test to measure the Urinary mutagenicity may be useful in biological monitoring of mutagen exposure level.

  • PDF

Characterization of resistance spot welded Al5052/DP590 dissimilar materials and processing optimization (저항점용접된 Al5052/DP590 이종소재의 특성평가 및 공정의 최적화)

  • Jo, Beom-Ji;Kim, Ji-Sun;Yoo, Hyo-Sang;Kim, In-Ju;Lee, Seong-Hui;Kim, Young-Gon
    • Journal of Welding and Joining
    • /
    • v.33 no.2
    • /
    • pp.56-61
    • /
    • 2015
  • IRW(Inverter Resistance Welding) process and DSW(Delta-spot welding) process for dissimilar materials of DP590 and Al5052 were performed to evaluate the welding quality and mechanical properties. IRW experiment was carried out with changing the welding current. The other welding parameters such as pressure force, weld time, squeezing time and holding time were fixed. On the anther hand, DSW experiment was performed using the process tape at welding current of 11.5kA. The other conditions were same as IRW conditions. The various testes such as shear tensile strength, nugget diameters, EDS, SEM and cross-sectional observation for weld zone was performed. As a result, IMC(Inter Metallic Compound) thickness at 11.5kA was thinner than those of 9.5kA and 10.5kA conditions. In addition, thined IMC layer was observed when high electric current apply to the materials(DP590 and Al5052) in a short time throught dissimilar resistance spot welding controling welding conditions. The relationship between the thickeness of IMC and current intensity was after discussed.

Theoretical Study on the Effects of the Withdrawal Weighting on the Performance of Resonator Type SAW Filters (공진기형 SAW 필터에 위드로월 가중법이 미치는 효과에 대한 이론적 연구)

  • 이영진;이승희;노용래
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.1
    • /
    • pp.47-55
    • /
    • 2002
  • This paper proposes a new improved lumped element equivalent circuit analysis method to analyze withdrawal weighted SAW resonators of irregular electrode configurations, which enables to calculate the frequency response of withdrawal weighted SAW resonators. This method has led to the derivation of Smith equivalent circuit's y-parameters for a single ground electrode and formulated the resonator's admittance by calculating the total current into an IDT assembly. To illustrate the effectiveness of the technique, this method was applied to the design of a simple ladder filter and the change of the filter performance was investigated in relation to the weighting of the series and parallel resonators, respectively. The results shows that the withdrawal weighted resonator ladder filters provide better performance in their bandwidth and transition characteristics than normal ones. This new equivalent circuit analysis method can also serve as a better tool to design and analyze general SAW resonator filters.

Design and Performance Test of Savonius Tidal Current Turbine with CWC (사보니우스형 조류발전 터빈의 설계 및 회류수조 실험을 통한 성능평가)

  • Jo, Chul-Hee;Lee, Jun-Ho;Rho, Yu-Ho;Ko, Kwang-Oh;Lee, Kang-Hee
    • Journal of Ocean Engineering and Technology
    • /
    • v.26 no.4
    • /
    • pp.37-41
    • /
    • 2012
  • Due to global warming, the need to secure alternative resources has become more important nationally. Because of the very strong current on the west coast, with a tidal range of up to 10 m, there are many suitable sites for the application of TCP (tidal current power) in Korea. In the southwest region, a strong current is created in the narrow channels between the numerous islands. A rotor is an essential component that can convert tidal current energy into rotational energy to generate electricity. The design optimization of a rotor is very important to maximize the power production. The performance of a rotor can be determined using various parameters, including the number of blades, shape, sectional size, diameter, etc. There are many offshore jetties and piers with high current velocities. Thus, a VAT (vertical axis turbine) system, which can generate power regardless of flow direction changes, could be effectively applied to cylindrical structures. A VAT system could give an advantage to a caisson-type breakwater because it allows water to circulate well. This paper introduces a multi-layer vertical axis tidal current power system. A Savonius turbine was designed, and a performance analysis was carried out using CFD. A physical model was also demonstrated in CWC, and the results are compared with CFD.

The New Active Voltage Clamp ZVS-PWM Resonant High-frequency Inverter (새로운 액티브 전압 클램프 ZVS-PWM 공진 고주파 인버터)

  • Ahn, Yong-Wie;Kim, Hong-Shin;Mun, Sang-Pil;Woo, Kyung-Il;Park, Han-Seok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.4
    • /
    • pp.188-193
    • /
    • 2017
  • In this paper, a ZVS-PWM high-frequency inverter with a PWM control function is applied to commercial system 220[Vrms], and a resonator type ZVS-PWM high-frequency inverter circuit with a fixed-two methods were proposed. The parameters of the transformer model equivalent circuit of a copier fixing device, which is an essential element in the parameter optimization of the proposed circuit, are obtained by using a high-frequency amplifier and its frequency characteristics are described. The proposed method compared to the existing single-ended ZVS-PFM high frequency inverter can suppress the voltage and current peak value of the power semiconductor switching device and reduce the switching loss. The efficiency of the proposed method itself is 98[%] at rated power output. Also, the efficiency of 96[%] can be obtained even at low output, so that the proposed high frequency inverter is very efficient inverter. The total efficiency from the commercial AC input to the inverter output is 93[%] at rated, which is considered efficient for use in copying machines. In addition, the diode bridge loss accounts for the largest portion of the overall system efficiency distribution. On the other hand, the nonparallel filter has a very low loss.