• Title/Summary/Keyword: Parameter study

Search Result 9,833, Processing Time 0.046 seconds

A Study on the Attribute Analysis of Software Reliability Model with Shape Parameter Change of Infinite Fault NHPP Lomax Life Distribution (무한고장 NHPP Lomax 수명분포의 형상모수 변화에 따른 소프트웨어 신뢰성 모형의 속성 분석에 관한 연구)

  • Min, Kyung-il
    • Journal of Convergence for Information Technology
    • /
    • v.9 no.8
    • /
    • pp.20-26
    • /
    • 2019
  • In this study, the optimal shape parameter condition is presented after analyzing the attributes of the software reliability model according to the change of the shape parameter of Loma life distribution with infinite fault NHPP. In order to analyze the software failure phenomena, the parametric estimation method was applied to the Maximum Likelihood Estimation method, and the nonlinear equation was applied to the bisection method. As a result, it was found that when the attributes according to the change of the shape parameter are compared, the smaller the shape parameter is, the better the prediction ability of the true value, and reliability attributes are efficient. Through this study, it is expected that software developers can increase reliability by preliminarily grasping the type of software failure based on shape parameter, and can be used as basic information to improve the software reliability attributes.

Study on the flood frequency analysis for the annual exceedance series -Centering along the Geum River basin- (연초과치 계열의 홍수빈도 분석에 관한 연구 -금강유역을 중심으로-)

  • 박영근;이순혁
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.24 no.1
    • /
    • pp.53-62
    • /
    • 1982
  • This study was attempted to find best fitted distribution and the equations for probable maximum flow with the evaluation of parameters by the method of moment for the rat- ional design of hydraulic structures in the annual exceedance series. Six subwatersheds were selected as studying basins along Geum River basin. The results obtained through this study were analyzed and summarized as follows. 1. Fitted probability distribution was showed in the order of Three Parameter Lognorm al, Type 1 Extremal, Exponential, Pearson Type III, and Log Pearson Type I distribu- tion as the results of x$^2$ goodness of fit test. 2. Kolmogorov-Smirnov test showed in the order of Three Parameter Lognormal, Exp- onential' Pearson Type III, Log Pearson Type III and Type 1 Extremal distribution for the fitted probability distribution. 3. It can be concluded that Three parameter Lognormal distribution is a best fitted one among some other distributions out of respect for each both tests. An Exponential distribution was proposed as a suitable one by Chow, V.T. showeci lower fittness than that of Three Parameter Lognormal in Geum River basin. 5. Probable flood flow equations followins the return periods for each station were obt- ained by Three Parameter Lognormal distribution. 6. It is urgently essential that best fitted probability distribution should be established for the annual exceedance series in the main river systems of Korea.

  • PDF

A study on the electrom beam weldability of 9%Ni steel (II) - Effect of $a_b$ parameter on bead shape - (9%Ni 강의 전자빔 용접성에 관한 연구 II -비이드형상에 미치는$a_b$parameter의 영향)

  • 김숙환;강정윤
    • Journal of Welding and Joining
    • /
    • v.15 no.3
    • /
    • pp.88-98
    • /
    • 1997
  • Welding defects, such as porosity and spike, have sometimes occurred in deep penetration electron beam welds. These defects are known to be one of the serious problem in electron beam welds. So, effects of active parameters ($a_b$) on bead shape and occurrence of defects in electron beam welds of heavy section 9%Ni steel plates were investigated. Partial penetration welding in flat position, and deep penetration welding of 10 ~ 28mm depth were investigated in this study. It is desirable to select low accelerating voltage and above the surface focus position $a_b$$\geq$1.2 at which a wine-cup shaped bead is obtained to avoid the welding defects such as spike and root porosity. When the accelerating voltage of electron beam was low (90kV), active parameter ($a_b$) did not influence on the bead width, penetration depth and weld defects significantly. However, in case of high voltage ($\geq$120kV), active parameter ($a_b$) was sensitively associated with penetraton depth and weld defects, i.e. when the active parameter (($a_b$) was in the range of 0.6 to 1.0, the depth of penetration was always over the target (23mm), while the depth of penetration was dramatically decreased with further increase of active parameter ($a_b$). The weld defects were decreased with the increase of active parameter $a_b$ resulting in the decrease of energy density of the focused beam in the root part of fusion zone.

  • PDF

The defect detection circuit of an electronic circuit through impedance change detection that induces a change in S-parameter (S-parameter의 변화를 유도하는 임피던스 변화 감지를 통한 전자회로의 결함검출회로)

  • Seo, Donghwan;Kang, Tae-yeob;Yoo, Jinho;Min, Joonki;Park, Changkun
    • Journal of IKEEE
    • /
    • v.25 no.4
    • /
    • pp.689-696
    • /
    • 2021
  • In this paper, in order to apply Prognostics and Health Management(PHM) to an electronic system or circuit, a circuit capable of detecting and predicting defect characteristics inside the system or circuit is implemented, and the results are described. In the previous study, we demonstrated that the frequency of the amplitude of S-parameter changed as the circuit defect progressed. These characteristics were measured by network analyser. but in this study, even if the same defect detection method is used, a circuit is proposed to check the progress of the defect, the remaining time, and the occurrence of the defect without large measurement devices. The circuit is designed to detect the change in impedance that generates changes of S-parameter, and it is verified through simulation using the measurement results of Bond-wires.

Robustness of Independent Modal Space Control for Parameter and Modal Filter Errors (파라메터오차 및 모달필터오차에 대한 독립모달공간 제어기법의 강인성 해석)

  • Hwang, Jai-Hyuk;Kim, Joon-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.11
    • /
    • pp.3549-3559
    • /
    • 1996
  • In this study, the effect of parameter and modal filter errors on the vibration control characteristics of flexible structures is analyzed for IMSC ( Independent Modal Space Control). If the control force is designed on the basis of the mathematical model with the parameter and modal filter errors, the closed-loop performance of the vibration control system will be degraded depending on the magnitude of the errors. An asymptotic stability condition of the system with parameter and modal filter errors has more significant effect on the stability condition of the system with parameter and modal filter errors has been drived using Lyapunov approach. It has been found that modal filter error has more significant effect on the stability of closed-loop system than parameter error does. The extent of the response deviation of the closed-loop system is also derived and evaluated using operator thchniques.

A Simulation study of EWMA control using dynamic control parameter (동적 모수를 사용한 EWMA 제어의 시뮬레이션 연구)

  • Kang, Seok-Chan;Hwang, Ji-Bin;Kim, Sung-Shick;Kim, Ji-Hyun
    • Journal of the Korea Society for Simulation
    • /
    • v.16 no.2
    • /
    • pp.37-44
    • /
    • 2007
  • EWMA is one of the most popular controller method used in Run-to-Run control system for semiconductor manufacturing. The value of the control parameter in EWMA has major effect on the result. Therefore, it is important to use control parameter value fitting for the process state. When the process is unstable, it is more efficient to change EWMA control parameter dynamically to compensate for the changing process state than using fixed control parameter. In this paper, we review previous studies using dynamic EWMA control parameter and propose a new algorithm complementing the weaknesses of the previous studies. The performance of the proposed algorithm is validated using simulation.

  • PDF

A study on improvement of policing perfomance by usage parameter control in asynchronous transfer mode networks (ATM망에서 사용자 변수 제어에 의한 감시 성능 개선에 관한 연구)

  • 한길성;오창석
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.6
    • /
    • pp.1480-1489
    • /
    • 1996
  • In ATM networks there are two methods in traffic control as schemes advancing the quality of service. One is reactive control after congestion and the other which is generally recommended, is preventive control before congestion, including connection admission control on call leel and usage parameter control, network parameter control, priority control and congestion control on cell level. In particular, usage parameter control is required for restricting the peak cell rate of bursy tracffic to the parameter negotiated at call set-up phase since the peak cell rate significantly influences the network quality of service. The scheme for progressing quality of service by usage parameter control is themethod using VSA(Virtual Scheduling Algorlithm) recommended ITU-T. The method using VSSA(Virtual Scheduling Suggested Algorlithm) in this paper is suggested by considering cell delay variation and token rate of leaky bucket, compared VSA and VSANT(Virtual Scheduling Algolithm with No Tolerance) with VSSA which polices violated cell probability of conformed peak cell rate and intentionally excessive peak cell rate. VSSA method using IPP(Interruped Poisson Process) model of input traffic source showed more quality of service than VSA and VSANT methods as usage parameter control because the suggested method reduced the violated cell probability of contformed peak cell rate and intentionally excessive peak cell rate.

  • PDF

Vibration analysis of porous nanocomposite viscoelastic plate reinforced by FG-SWCNTs based on a nonlocal strain gradient theory

  • Khazaei, Pegah;Mohammadimehr, Mehdi
    • Computers and Concrete
    • /
    • v.26 no.1
    • /
    • pp.31-52
    • /
    • 2020
  • This paper investigates the size dependent effect on the vibration analysis of a porous nanocomposite viscoelastic plate reinforced by functionally graded-single walled carbon nanotubes (FG-SWCNTs) by considering nonlocal strain gradient theory. Therefore, using energy method and Hamilton's principle, the equations of motion are derived. In this article, the effects of nonlocal parameter, aspect ratio, strain gradient parameter, volume fraction of carbon nanotubes (CNTs), damping coefficient, porosity coefficient, and temperature change on the natural frequency are perused. The innovation of this paper is to compare the effectiveness of each mentioned parameters individually on the free vibrations of this plate and to represent the appropriate value for each parameter to achieve an ideal nanocomposite plate that minimizes vibration. The results are verified with those referenced in the paper. The results illustrate that the effect of damping coefficient on the increase of natural frequency is significantly higher than the other parameters effect, and the effects of the strain gradient parameter and nonlocal parameter on the natural frequency increase are less than damping coefficient effect, respectively. Furthermore, the results indicate that the natural frequency decreases with a rise in the nonlocal parameter, aspect ratio and temperature change. Also, the natural frequency increases with a rise in the strain gradient parameter and CNTs volume fraction. This study can be used for optimizing the industrial and medical designs, such as automotive industry, aerospace engineering and water purification system, by considering ideal properties for the nanocomposite plate.

Structure Parameter Change Estimation of a Forward Osmosis Membrane Under Pressurized Conditions in Pressure-assisted Forward Osmosis (PAFO) (가압형 정삼투 시 압력에 따른 정삼투막의 Structure Parameter 변화양상 예측)

  • Kook, Seungho;Kim, Sung-Jo;Lee, Jinwoo;Hwang, Moonhyun;Kim, In S.
    • Membrane Journal
    • /
    • v.26 no.3
    • /
    • pp.187-196
    • /
    • 2016
  • Pressure-assisted forward osmosis (PAFO) process has recently been under spotlight for its potential to improve forward osmosis (FO) process performance by applying low hydraulic pressure on the feed side. Structure parameter, one of the governing factors in estimating water flux and solute flux across FO membranes in the solution-diffusion model (S-D model), determines solute resistivity in FO and PAFO processes. This study aims to estimate the trend of structure parameter change with respect to varying additional hydraulic pressure condition in PAFO.

Development of Transverse Bed Slope Model for Nonuniform Sand Bed at River Bend (만곡부 혼합입경 하상횡경사 모형의 개발)

  • 최종인;고재웅
    • Water for future
    • /
    • v.29 no.4
    • /
    • pp.177-186
    • /
    • 1996
  • The analytical approach to determine transverse sand bed slope at river bend are based on two phases that the flow is considered as fully developed flow and the bed is fluvial having bed load. All existing methods are theoretically derived from the initiation of motion of the particles at river bed. They assume that the Shields parameter has a constant value of 0.06. In this study, the variability of Shields parameter due to the differences of shape of grain size distribution is considered. Therefore the parameter is not a constant, 0.06, but depends on the shape of the grain size distribution. This result gives good agreement to estimate transverse bed slope with actual field data at river bend.

  • PDF