• Title/Summary/Keyword: Parameter monitoring

Search Result 612, Processing Time 0.026 seconds

Tool Life Monitoring using AE Signal in Gear Shaping (기어가공식 AE 신호를 이용한 공구수명의 감시)

  • 최성필
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.130-134
    • /
    • 1996
  • The characteristics of AE(Acoustic Emission) signal is related to cutting conditio, tool material, and tool geometry in metal cutting. The relation between AE signal and tool life was investigated experimentally. Experiment is carried out by gear shaping and SCM 420 workpiece. AE RMS voltage were increased according totool wear. It is suggested that maximum value of AE RMS voltage is an effective parameter to monitor tool life.

  • PDF

Monitoring System Development of Abnormal State in Air Conditioner Compressor

  • 이감규;정지홍;강명창;김정석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.186-189
    • /
    • 1997
  • To monitor abnormal state of rotary compressor, methods for acquisition and processing of Acoustic Emission(AE) signal are arranged and optimal AE parameter for monitoring is determined. The detecting method of abnormal compressor in real time is suggested and special-purpose minitoring system which can be applied to automatic manufacturing line is developed using one-chip microprocessor in low cost.

Parameter Measurement and Torque Monitoring System for Induction Motors (유도전동기의 매개변수 측정과 토크 모니터링 시스템)

  • Kim Jin-woo;Kim Gyu-Sik;Kwon Won-Tae;Park Jin-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.131-134
    • /
    • 2001
  • The accurate identification of the motor parameters is crucially important to achieve high dynamic performance of induction motors. In this paper, the motor parameters such as rotor resistance, stator(rotor) leakage inductance, mutual inductance are measured for torque monitoring and indirect vector control. To demonstrate the practical significance of the results, some experimental results are presented.

  • PDF

Health Monitoring of High-rise Building with Fiber Optic Sensor (SOFO)

  • Mikami, Takao;Nishizawa, Takao
    • International Journal of High-Rise Buildings
    • /
    • v.4 no.1
    • /
    • pp.27-37
    • /
    • 2015
  • Structural health monitoring is becoming more and more important in the domain of civil engineering as a proper mean to increase and maintain the safety, especially in the land of earthquakes like Japan. In many civil structures, the deformations are the most relevant parameter to be monitored. In this context, a monitoring technology based on the use of long-gage fiber optic deformation sensor, SOFO is being applied to a 33-floors tall building in Tokyo. Sensors were installed on the $2^{nd}$ floor's steel columns of the building on May 2005 in the early stage of the construction. The installed SOFO sensors were dynamic compatible ones which enable both static and dynamic measurements. The monitoring is to be performed during the whole lifespan of the building. During the construction, static deformations of the columns had been measured on a regular basis using a reading unit for static measurement and dynamic deformation measurements were occasionally conducted using a reading unit for dynamic measurement. The building was completed on August 2006. After the completion, static and dynamic deformation measurements have been continuing. This paper describes a health monitoring technology, SOFO system which is applicable to high-rise buildings and monitoring results of a 33-floors tall building in Tokyo from May 2005 to October 2010.

A Study on Analysis of Propagation Speed of Power Frequency by Generation Drop (발전기 탈락에 따른 주파수의 전파속도 해석에 관한 연구)

  • Kim, Hak-Man;Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.4
    • /
    • pp.295-300
    • /
    • 2014
  • The frequency is an important operating parameter of a power system. There is an increasing importance of constant monitoring of frequency to achieve stable power supply by WAMS(wide area monitoring system) and FNET(Frequency Monitoring Network). This paper is part of development of a network-based frequency monitoring and failure prediction system for wide-area intelligent protection relaying. In this paper, analysis of propagation speed of power frequency by generation drop using the PSS/E was carried out. For dynamic analysis, the 11 metropolitan areas offices of KEPCO divided into five groups of Seoul, Gangwon, Chungcheong, Honam, and Yeongnam group, study was performed.

Condition Monitoring of Hydraulic Piston Motor using Morphological Analysis of Wear Particles (마멸입자 형태해석에 의한 유압피스톤용 모터의 상태감시)

  • 문병주;조연상;박흥식;전태옥
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.6
    • /
    • pp.127-132
    • /
    • 2000
  • Morphological analysis of wear particles is one of useful methods for machine condition monitoring because it is well reflected in machine driving state. This paper was undertaken to apply to the condition monitoring of hydraulic piston motor. The lubricating wear test was performed under different experimental conditions using the wear test device and wear specimens of the pin on disk type was rubbed in paraffinic base oil by three kinds of lubricating materials, varying applied load, sliding distance. The four shape parameters(50% volumetric diameter, aspect, roundness and reflectivity) are used for morphological analysis of wear particles. The results showed that the four shape parameters of wear particles depend on a kind of the lubricating materials. It was capable of calculating presumed wear volume for three kinds of materials on driving time to foresee as damage condition of lubricating materials.

  • PDF

Chatter Monitoring of Milling Process using Spindle Displacement Signal (주축 변위 신호를 이용한 밀링가공의 채터 감시)

  • Chang, Hun-Keun;Kim, Il-Hae;Jang, Dong-Young
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.6
    • /
    • pp.140-145
    • /
    • 2007
  • To improve productivity of a metal cutting process, it is required to monitor machining stability in real time. Since cutting environment is harsh against sensing conditions due to vibration, chip, and cutting fluid, etc., it is necessary to develop a robust and reliable sensing system for the practical application. In this work, a chatter monitoring system was developed and its effectiveness was proved. Spindle displacement caused by cutting was selected as a main monitoring parameter. A cylindrical capacitive displacement sensor was adopted. Chatter frequencies were identified through modal analysis. To quantify chatter vibrations, chatter correlation coefficient was introduced. The identification of the monitoring system showed a good agreement with the result of experiment.

Real-time In-situ Plasma Etch Process Monitoring for Sensor Based-Advanced Process Control

  • Ahn, Jong-Hwan;Gu, Ja-Myong;Han, Seung-Soo;Hong, Sang-Jeen
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.11 no.1
    • /
    • pp.1-5
    • /
    • 2011
  • To enter next process control, numerous approaches, including run-to-run (R2R) process control and fault detection and classification (FDC) have been suggested in semiconductor manufacturing industry as a facilitation of advanced process control. This paper introduces a novel type of optical plasma process monitoring system, called plasma eyes chromatic system (PECSTM) and presents its potential for the purpose of fault detection. Qualitatively comparison of optically acquired signal levels vs. process parameter modifications are successfully demonstrated, and we expect that PECSTM signal can be a useful indication of onset of process change in real-time for advanced process control (APC).

Parameter Estimation of 2-DOF Dynamic System using Particle Filter (파티클 필터를 이용한 2 자유도 동역학 시스템의 파라미터 추정)

  • Kim, Tae-Yeong;Chong, Kil-To
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.2
    • /
    • pp.10-16
    • /
    • 2012
  • Currently, the majority of systems which are non-linear are in need of the correct system equations for controlling and monitoring. Therefore, the correct estimation of parameters is crucial. Generally, parameters are changed due to system deterioration or sudden environmental alterations. Given the limitations of system monitoring unstable controls can arise. In the following paper, the parameter estimation method is proposed using software filters to combat these system instabilities. For dynamic instances, a powerful particle filter is used to control the nonlinear and noisy environments in which they take place. Using a setup simulation comprised of a slider and pendulum, the state variable of noise is obtained. After collecting the data, the proposed algorithm is used to estimate both the state variable and its parameters. Finally, these results are checked with correct parameter estimations to evaluate and verify the algorithms performance.

Implementation of cost-effective wireless photovoltaic monitoring module at panel level

  • Jeong, Jin-Doo;Han, Jinsoo;Lee, Il-Woo;Chong, Jong-Wha
    • ETRI Journal
    • /
    • v.40 no.5
    • /
    • pp.664-676
    • /
    • 2018
  • Given the rapidly increasing market penetration of photovoltaic (PV) systems in many fields, including construction and housing, the effective maintenance of PV systems through remote monitoring at the panel level has attracted attention to quickly detect faults that cause reductions in yearly PV energy production, and which can reduce the whole-life cost. A key point of PV monitoring at the panel level is cost-effectiveness, as the installation of the massive PV panels that comprise PV systems is showing rapid growth in the market. This paper proposes an implementation method that involves the use of a panel-level wireless PV monitoring module (WPMM), and which assesses the cost-effectiveness of this approach. To maximize the cost-effectiveness, the designed WPMM uses a voltage-divider scheme for voltage metering and a shunt-resistor scheme for current metering. In addition, the proposed method offsets the effect of element errors by extracting calibration parameters. Furthermore, a design method is presented for portable and user-friendly PV monitoring, and demonstration results using a commercial 30-kW PV system are described.