• Title/Summary/Keyword: Parameter Standardization

Search Result 33, Processing Time 0.027 seconds

NIST Lightweight Cryptography Standardization Process: Classification of Second Round Candidates, Open Challenges, and Recommendations

  • Gookyi, Dennis Agyemanh Nana;Kanda, Guard;Ryoo, Kwangki
    • Journal of Information Processing Systems
    • /
    • v.17 no.2
    • /
    • pp.253-270
    • /
    • 2021
  • In January 2013, the National Institute of Standards and Technology (NIST) announced the CAESAR (Competition for Authenticated Encryption: Security, Applicability, and Robustness) contest to identify authenticated ciphers that are suitable for a wide range of applications. A total of 57 submissions made it into the first round of the competition out of which 6 were announced as winners in March 2019. In the process of the competition, NIST realized that most of the authenticated ciphers submitted were not suitable for resource-constrained devices used as end nodes in the Internet-of-Things (IoT) platform. For that matter, the NIST Lightweight Cryptography Standardization Process was set up to identify authenticated encryption and hashing algorithms for IoT devices. The call for submissions was initiated in 2018 and in April 2019, 56 submissions made it into the first round of the competition. In August 2019, 32 out of the 56 submissions were selected for the second round which is due to end in the year 2021. This work surveys the 32 authenticated encryption schemes that made it into the second round of the NIST lightweight cryptography standardization process. The paper presents an easy-to-understand comparative overview of the recommended parameters, primitives, mode of operation, features, security parameter, and hardware/software performance of the 32 candidate algorithms. The paper goes further by discussing the challenges of the Lightweight Cryptography Standardization Process and provides some suitable recommendations.

Performance Analysis of the UPC/NPC Algorithm for Guaranteed QoS in ATM Networks

  • Kim, Yong-Jin;Kim, Jang-Kyung;Lee, Young-Hee;Park, Chee-Hang
    • ETRI Journal
    • /
    • v.20 no.3
    • /
    • pp.251-271
    • /
    • 1998
  • It is well known that if usage parameter control/network parameter control (UPC/NPC) functions are used together with a cell loss priority control scheme in ATM networks, the measurement phasing problem can occur. This makes it difficult for a network provider to define and commit the cell loss ratio as a QoS parameter. To solve the problem, we propose a new UPC/NPC algorithm. By using the proposed UPC/NPC algorithm, we can define the cell loss ratios for CLP = 0 and CLP = 0+1 cell streams without the measurement phasing problem under any conditions. We analyzed the performance of the proposed UPC/NPC algorithm. Using a discrete time model for the UPC/NPC architecture with a discrete-time semi-Markov process (DSMP) input model, we obtained the cell discarding probabilities of CLP = 0 and CLP = 0+1 cells streams and showed that more CLP = 0 cells are accepted compared to what was proposed in ITU-T.

  • PDF

A study on the Ad-hoc Network Application of Zone Routing Protocol (Zone Routing Protocol의 Ad-hoc네트워크 적용에 관한 연구)

  • Lee Young Roh;Kim Yong-Deuk
    • Proceedings of the IEEK Conference
    • /
    • 2004.06a
    • /
    • pp.119-122
    • /
    • 2004
  • This mobile oriented Ad-hoc network yet steps on development level, related issues and standardization are progressing. This paper presented ad-hoc network's overview and overall property, followed by routing scheme that must be setup for communication between each nodes. Among several routing scheme proposed for standardization, ZRP that is foaled by this paper, is hybrid type algorithm, and only includes advantages of others This paper presented running process and implementation method, result that is made from network simulation, shows analysis of each parameter values's change. Each parameters changed with many differences according to Zone radius and communication node's location from simualtion that was performed changing a number of nodes and a velocity of nodes.

  • PDF

Systematization design and the analogical interpretation of machinery character by use CAE (컴퓨터 응용기술(CAE)을 이용한 기기특성의 유추해석과 계열화 설계)

  • 조경재;조제황;이권현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.851-856
    • /
    • 1996
  • In this paper, we introduce the design method using CAE(Computer Aided Engineering) which is profitable in the compatability and standardization of the developed product, and the reduction of construction time and price to develop and design a machine equipment. Particularly, we select the standard model to design or develop from the large machinery to the super precision one, extract the peculiar characters of the model by the close analysis of the physical and technical part, the experiment for the characteristics of objective dimensions by analogical mathematical analysis for previous results, and can induce the design model demanded by user investigating optimal data in the design previous We present the analogical algorithms and process method of design factors and restriction factors in the systematization design with computer. Then we analyze step functions for each systematization equipment and induce the process of technical data with actuator model.

  • PDF

Study on the Standardization and Physicochemical Property for Non-waxy Gyungdan Adapted with Mechanically Impacting Technology (기계적 충격기술을 적용한 멥쌀 경단의 규격 표준화 및 품질특성에 대한 연구)

  • Han, Seo-Young;Park, Hye-Young;Shin, Dong-Sun;Kim, Kyung-Mi;Han, Gwi-Jung
    • Korean journal of food and cookery science
    • /
    • v.29 no.1
    • /
    • pp.29-36
    • /
    • 2013
  • The present study was conducted to supply more scientific information for standardization of preparation method of Gyungdan and to determine the standard for manufacturing procedure adapted with mechanically impacting technology (MIT) for mass production. The optimum preparation condition for non-waxy Gyungdan adapted with MIT was 35% of water, 0.5% of wheat flour (w/w of soaked rice), and mechanically impacting for 10 min at 450 rpm. In the present study, standardization of manufacturing procedure for merchandizing of Gyungdan was established with width, weight, and height. Average of Gyungdan adapted with MIT at 90 rpm (stuffing speed) and 46.58 Herz (cutting speed) is 18.3 g of weight, 28.4 mm of height, and 32.4 mm of width. Hardness, as a main parameter of texture profile, of Gyungdan was maintained lower than 100 g up to 3 days at the storage of $20^{\circ}C$ and up to 70 days at the storage of $-20^{\circ}C$. And, it was performed to develop rice cake as meal-replacement adapted with MIT and sub-ingredients such as strawberry, pumpkin, and mugwort. Gyungdan prepared under controlling manufacturing condition of MIT was supplemented with 0-1.6% of sub-ingredients, respectively. In sensory tests, the best substitute ratios of strawberry, pumpkin, and mugwort were 1.6%, 0.8%, and 1.6%, respectively. With the results above, not-harden Gyungdan supplemented with sub-ingredients and various stuffs can be expected to application for wheat-substitute meal-replacement.

Design Property Proof of Traction Motor for Urban Transit EMU by FEM Analysis (도시철도차량 표준전동차용 견인전동기의 유한요소 해석에 의한 설계특성 검증)

  • Lee, S.G.;Wang, J.B.;Kim, M.Y.;Park, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.458-460
    • /
    • 1999
  • In this paper, the results of FEM electromagnetic analysis performed in the standardization development of traction motor for EMU are reviewed. The selection of optimal design parameter and performance analysis are proven through the complement of the circuit parameters on the basis of Performance test for developed traction motor.

  • PDF

Development of Standard Operating Procedures (SOPs), Standardization, TLC and HPTLC Fingerprinting of a Polyherbal Unani Formulation

  • Naaz, Arjumand;Viquar, Uzma;Naikodi, Mohammad Abdul Rasheed;Siddiqui, Javed Inam;Zakir, Mohammad;Kazmi, Munawwar Husain;Minhajuddin, Ahmed
    • CELLMED
    • /
    • v.11 no.4
    • /
    • pp.21.1-21.9
    • /
    • 2021
  • Background: Unani System of Medicine (USM) has its origin to Greece. To ensure and develop the quality, authenticity of Unani drugs, standardization on modern analytical parameter is essential requirement for drugs. Objectives: The aimed of the present study was to develop a standard profile of "Qurṣ-e-Mafasil" by systematic study through authenticated ingredients, pharmacognostic identification followed by physicochemical, TLC, HPTLC fingerprinting analysis as per standard protocol. Material and Methods: In this study three batches of "Qurṣ-e-Mafasil" QM were prepared by standard method as per UPI had been followed by organoleptic properties of formulation such as appearance, color, odor, taste. Powder Microscopy and physicochemical studies were carried out such as Uniformity of weight, Friability, Disintegration time, hardness, LOD, ash vales and extractive values in like aqueous, alcohol & hexane. Further qualitative tests such as Thin-Layer Chromatography (TLC), and High-Performance Thin Layer Chromatography (HPTLC) studies were also carried out to develop fingerprint pattern of the alcoholic solvent extract of QM. Phytochemical screening was carried out in different solvent extracts such as alcoholic, aqueous and chloroform extracts to detect the presence phytoconstituents in the formulation QM. Heavy metals, Microbial Load Contamination and pesticidal residues were also determined. Results: Qurṣ-e-Mafasil showed tablet-like appearance, light brown colour, mild pungent odour and acrid taste. Uniformity of weight (mg), friability (rpm), and hardness (kg/cm) and disintegration time was ranged between (500 to 503), (0.0340 to 0.038), (8.40 to 8.67) and (4-5 minutes) respectively for the three batches. Loss in weight on drying at 105℃ was ranged between (8.3425 to 8.7346). Extracted values were calculated in distilled water ranged between (30.9091 to 31.4358), hexane (1.1419 to 1.4281), and alcohol (3.3352 to 3.3962). The ash values recorded were ranged between (3.7336 to 3.8378), and acid insoluble ash (0.5859 to 0.6112).

Adaptable Dynamic Slot Assignment of VBR Traffics Using In-band Parameter in Wireless ATM (무선 ATM에서 In-Band파라미터를 이용한 VBR트래픽의 적응적 슬롯할당에 관한 연구)

  • 백종일;전찬용;김영철
    • Proceedings of the IEEK Conference
    • /
    • 2000.06a
    • /
    • pp.131-134
    • /
    • 2000
  • Only MAC protocol can satisfy the service quality of the request of bandwidth, delay time, and cell loss at the same time and it is because MAC protocol provides mobile terminal an environment to use channel evenly and effectively This Paper has been adapted Mobile ATM Standardization of ETSI in maximum and used not only for practicing in-band signal to a priority order but also to the next reserved slot assignment of the dynamic frame. Also, by accepting VBR traffic more adaptively, the effectiveness of transmission channel has been maximized as well, and these are compared with the old way of it and analyzed to confirm the effectiveness.

  • PDF

The basic investigation for the objective study on the pulsation (맥진의 현대적인 객관화 연구를 위한 기반조사 - I. 기계적 측정법에 대한 비교연구-)

  • Kim Gyeong Cheol;Shin Soon Shik;Kang Hee Jung;Cha Chul Yong
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.17 no.5
    • /
    • pp.1147-1150
    • /
    • 2003
  • Modern Objectification of Pulse Diagnosis, One of the Four Diagnosis Method of Oriental Medicine, is necessarily project to improving Oriental medical clinic status and quality by standardization of diagnosis database. At that, accurate measurement equipment or devices(sensor, system and instruments, etc,) to exactly detect MacSang(脈診 : the parameter and subject of pulse diagnosis) have not developed yet. Existing Pulse diagnosis devices are not satisfy clinical needs and medical equipments quality. We study for pulse diagnosis system, that CD is satisfying oriental medical clinic needs, is ensuring accuracy and reappearance to support in clinical diagnosis and treatment, is guaranteeing the quality of medical equipments. theoretical base and convenience.

A Study on Estimation uncertainty of measurement in mechanical characteristic exam for Plastic materials (플라스틱재료의 기계적 특성시험 불확도추정에 대한 고찰)

  • Kim Won-kyung;Kwon Sung-Tae;Kim Jung-Nam
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.301-306
    • /
    • 2003
  • Recently, uncertainty of measurement became a major concern for the people working on the laboratory evaluation and accreditation. 'uncertainty of measurement is a parameter associated with the result of a measurement that characteristics the dispersion of the value that could reasonably be attributed to the measured.' This study analysed how to estimate uncertainty of measurement in mechanical characteristic exam for Plastic material. its uncertainty was estimated according to International Organization for Standardization(ISO), they were named to A type uncertainty, B type uncertainty, combined standard uncertainty, and expanded uncertainty. We obtained that the combined standard uncertainty was 0.96697 MPa and the expanded uncertainty was 2.291MPa.

  • PDF