• 제목/요약/키워드: Parallel-flow

검색결과 1,066건 처리시간 0.035초

공항용량 향상을 위한 위성항법기반 평행 접근 연구 (GNSS-based Parallel Approaches to Increase Airport Capacity)

  • 신권상;여송희;이형복
    • 한국항공운항학회지
    • /
    • 제22권2호
    • /
    • pp.53-59
    • /
    • 2014
  • Simultaneous parallel approaches in all weather conditions should be applied to manage efficiently increasing volume of air traffic flow and solve the problem of delayed arrivals. But All of the airports which have closely-spaced parallel-runways in Korea don't meet the interval-standards for IFR parallel approaches. In that regard, more accurate and safer System should be applied for the Korean airports. GNSS was adopted as an international standard of the next-generation navigation system and many studies and master plans have been activated by stages in Korea. In this paper, the current state of the domestic airports will be analyzed focusing on the interval of parallel runways and future specification of both flight operation system and air-side management will be recommended.

그래픽 사용자 인터페이스로 구현한 병렬 프로그래밍 환경 (A Parallel Programming Environment Implemented with Graphic User Interface)

  • 유정목;이동희;이만호
    • 한국정보처리학회논문지
    • /
    • 제7권8호
    • /
    • pp.2388-2399
    • /
    • 2000
  • 본 논문에서는 사용자의 병렬 프로그램 작성을 도와주는 병렬 프로그래밍 환경에 대해 기술한다. 병렬 프로그래밍 환경은 일반적인 컴파일러의 기능의 전위 부분에 해당하는 어휘분석과 구문분석 기능 수행하고 있으며, 프로그램에서 이용하는 변수들의 데이터 흐름 분석과 데이터 종속성 분석, 그리고, 여러 가지 병렬 프로그램 변환 기법들을 수행한다. 특히 프로그래머가 병렬 프로그램을 용이하게 작성할 수 있도록 그래픽 사용자 인터페이스를 제공한다.

  • PDF

Battery Equalization Method for Parallel-connected Cells Using Dynamic Resistance Technique

  • La, Phuong-Ha;Choi, Sung-Jin
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 추계학술대회
    • /
    • pp.36-38
    • /
    • 2018
  • As the battery capacity requirement increases, battery cells are connected in a parallel configuration. However, the sharing current of each battery cell becomes unequal due to the imbalance between cell's impedance which results the mismatched states of charge (SOC). The conventional fixed-resistance balancing methods have a limitation in battery equalization performance and system efficiency. This paper proposes a battery equalization method based on dynamic resistance technique, which can improve equalization performance and reduce the loss dissipation. Based on the SOC rate of parallel connected battery cells, the switches in the equalization circuit are controlled to change the equivalent series impedance of the parallel branch, which regulates the current flow to maximize SOC utilization. To verify the method, operations of 4 parallel-connected 18650 Li-ion battery cells with 3.7V-2.6Ah individually are simulated on Matlab/Simulink. The results show that the SOCs are balanced within 1% difference with less power dissipation over the conventional method.

  • PDF

SPARSE NULLSPACE COMPUTATION OF EQULILBRIUM MATRICES

  • Jang, Ho-Jong;Cha, Kyung-Joon
    • 대한수학회논문집
    • /
    • 제11권4호
    • /
    • pp.1175-1185
    • /
    • 1996
  • We study the computation of sparse null bases of equilibrium matrices in the context of structural optimization and incompressible fluid flow. In our approach we emphasize the parallel computatin and examine the applications. New block decomposition and node ordering schemes are suggested, and numerical examples are considered.

  • PDF

이진가중형 유체 디지털-아날로그 변환기를 이용한 고정도 미소유량 조절기 (Digital Microflow Controllers Using Fluidic Digital-to-Analog Converters with Binary-Weighted Flow Resistor Network)

  • 윤상희;조영호
    • 대한기계학회논문집A
    • /
    • 제28권12호
    • /
    • pp.1923-1930
    • /
    • 2004
  • This paper presents digital microflow controllers(DMFC), where a fluidic digital-to-analog converter(DAC) is used to achieve high-linearity, fine-level flow control for applications to precision biomedical dosing systems. The fluidic DAC, composed of binary-weighted flow resistance, controls the flow-rate based on the ratio of the flow resistance to achieve high-precision flow-rate control. The binary-weighted flow resistance has been specified by a serial or a parallel connection of an identical flow resistor to improve the linearity of the flow-rate control, thereby making the flow-resistance ratio insensitive to the size uncertainty in flow resistors due to micromachining errors. We have designed and fabricated three different types of 4-digit DMFC: Prototype S and P are composed of the serial and the parallel combinations of an identical flow resistor, while Prototype V is based on the width-varied flow resistors. In the experimental study, we perform a static test for DMFC at the forward and backward flow conditions as well as a dynamic tests at pulsating flow conditions. The fabricated DMFC shows the nonlinearity of 5.0% and the flow-rate levels of 16(2$^{N}$) for the digital control of 4(N) valves. Among the 4-digit DMFC fabricated with micromachining errors, Prototypes S and P show 27.2% and 27.6% of the flow-rate deviation measured from Prototype V, respectively; thus verifying that Prototypes S and P are less sensitive to the micromachining error than Prototype V.V.

Optimal Power Flow with Discontinous Fuel Cost Functions Using Decomposed GA Coordinated with Shunt FACTS

  • Mahdad, Belkacem;Srairi, K.;Bouktir, T.;Benbouzid, M.EL.
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권4호
    • /
    • pp.457-466
    • /
    • 2009
  • This paper presents efficient parallel genetic algorithm (EPGA) based decomposed network for optimal power flow with various kinds of objective functions such as those including prohibited zones, multiple fuels, and multiple areas. Two coordinated sub problems are proposed: the first sub problem is an active power dispatch (APD) based parallel GA; a global database generated containing the best partitioned network: the second subproblem is an optimal setting of control variables such as generators voltages, tap position of tap changing transformers, and the dynamic reactive power of SVC Controllers installed at a critical buses. The proposed approach tested on IEEE 6-bus, IEEE 30-bus and to 15 generating units and compared with global optimization methods (GA, DE, FGA, PSO, MDE, ICA-PSO). The results show that the proposed approach can converge to the near solution and obtain a competitive solution with a reasonable time.

CFD를 이용한 병열 배열형 상향류식 침전지 수리해석에 관한 연구(I) - 침전지 내 유입유량 불균등 영향 조사 - (Evaluation of Hydraulic Behavior within Parallel arranged Upflow Sedimentation Basin Using CFD Simulation (I) - The influence of feed water inequity-)

  • 박노석;김성수;최종웅;성열붕;강문선
    • 상하수도학회지
    • /
    • 제27권4호
    • /
    • pp.469-477
    • /
    • 2013
  • In order to investigate the influence of feed water inequity on the settling performance for parallel arranged upflow sedimentation basin in domestic G_WTP(Water Treatment Plant), CFD(Computational Fluid Dynamics) simulation were employed and ADV(Acoustic Doppler Velocimeter) measurements were carried out. From the results of both CFD simulations and ADV measurements, the differences among inlet flow rates to each inlet structure make turbulent energy dissipation uneven overall sedimentation basin. Especially local velocities in the near of both side wall were observed over the design overflow rate(74.4 mm/min). Also, it was confirmed that this inequity of inlet flow would exert an serious influence on the turbidity of settled water which is out from 8 troughs. Even though experimental velocities in full scale basin about 20% higher than the simulated, the results of ADV measurement were in good accordance with those of CFD simulations.

수직 등온 평행 평판에서 상호작용 유동이 대류 열전달에 미치는 영향 (The Effect of the Interactive Flow on Convective Heat Transfer from two Vertical Isothermal Parallel Plates)

  • 김상영;정한식;권순석
    • 대한기계학회논문집
    • /
    • 제16권4호
    • /
    • pp.765-774
    • /
    • 1992
  • 본 연구에서는 수직 등온 평행평판의 혼합대류 열전달에 대하여 두 평판의 길 이가 다른 경우를 고찰하고자 Reynolds수, Grashof수, 평판간격을 변수로 하여 수치해 석 하였다.

RECENT IMPROVEMENTS IN THE CUPID CODE FOR A MULTI-DIMENSIONAL TWO-PHASE FLOW ANALYSIS OF NUCLEAR REACTOR COMPONENTS

  • Yoon, Han Young;Lee, Jae Ryong;Kim, Hyungrae;Park, Ik Kyu;Song, Chul-Hwa;Cho, Hyoung Kyu;Jeong, Jae Jun
    • Nuclear Engineering and Technology
    • /
    • 제46권5호
    • /
    • pp.655-666
    • /
    • 2014
  • The CUPID code has been developed at KAERI for a transient, three-dimensional analysis of a two-phase flow in light water nuclear reactor components. It can provide both a component-scale and a CFD-scale simulation by using a porous media or an open media model for a two-phase flow. In this paper, recent advances in the CUPID code are presented in three sections. First, the domain decomposition parallel method implemented in the CUPID code is described with the parallel efficiency test for multiple processors. Then, the coupling of CUPID-MARS via heat structure is introduced, where CUPID has been coupled with a system-scale thermal-hydraulics code, MARS, through the heat structure. The coupled code has been applied to a multi-scale thermal-hydraulic analysis of a pool mixing test. Finally, CUPID-SG is developed for analyzing two-phase flows in PWR steam generators. Physical models and validation results of CUPID-SG are discussed.

PIV를 이용한 평행평판 내의 혼합대류의 정량적 가시화 (A Quantitative Visualization of Mixed Convection in Parallel Plates Using PIV)

  • 박일용;배대석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권3호
    • /
    • pp.509-515
    • /
    • 2004
  • The PIV(Particle Image Velocimetry) with liquid crystal tracers is used for visualizing and analysis of the mixed convection in the parallel plates with the upper part cooled and the lower part heated. It is found that the flow pattern of mixed convection in the parallel plates can be classified into three patterns which was affected by Reynolds number. Also, the periodic nature is confirmed, and visualized in experiment.