• Title/Summary/Keyword: Parallel-Flow Heat Exchanger

검색결과 77건 처리시간 0.025초

환경변화에 따른 핀-관, PF 열교환기 적용 공조기 성능 특성 실험 연구 (Performance Characteristics on Environment Change of A/C applied Fin-tube and PF Heat Exchangers)

  • 박경만;엄유식;권영철;이상재
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1267-1271
    • /
    • 2009
  • In the present study, performance characteristics on environment change of A/C applied fin-tube and PF heat exchangers were experimentally investigated. Capacity and COP changing an outlet air velocity, an indoor/outdoor temperature and a relative humidity were obtained. Air-enthalpy calorimeter was used. As the air velocity, indoor temperature and relative humidity increase, capacity and COP increase. PF A/C has smaller refrigerant weight than the fin-tube A/C. The performance of PF-2 A/C with the squarer fin was more excellent than that of PF-1 A/C with the triangler fin.

  • PDF

PF 열교환기가 적용된 슬림형 중계기 냉각기 (Slim Electronic Panel Cooler with Parallel Flow Condenser)

  • 조진표;김내현;이재훈;이진용;목인균;임원경;임석선
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.483-488
    • /
    • 2006
  • In this study, newly-developed slim electronic panel cooler with aluminum PF condenser and evaporator was tested and the results are compared with imported panel cooler with fin-tube heat exchangers. The PF heat exchangers significantly (approximately 45%) reduced the refrigerant charge. The air-side pressure drop was also reduced, which resulted in the reduction of the sound level of the panel cooler. The effect of the condenser size was also investigated.

  • PDF

병렬식 하이브리드 흡수식 냉온수기 동특성 시뮬레이션 연구 (A Study on Dynamic Simulation of a Hybrid Parallel Absorption Chiller)

  • 신영기;서정아;우성민;김효상
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.630-635
    • /
    • 2008
  • A dynamic model has been developed to investigate the operability of a single and double-effect solar energy assisted parallel type absorption chiller. In the study, main components and fluid transport mechanism have been modeled. Flow discharge coefficients of the valves and the pumps were optimized for the double-effect mode with solar-heated water circulated. The model was run for the single mode with solar energy supply only and the solar/gas driving double effect mode. And the cases of the double mode with and without the solar energy were compared. From the simulation results, it was found that the present configuration of the chiller is not capable of regulating solution flow rates according to variable solar energy input. And the single mode utilizing the solar energy only is not practical. It is suggested to operate the system in the double mode and the flow rate control system adaptive to variable solar energy input has to be developed.

  • PDF

핀-관, 평행류 열교환기를 적용한 공조기의 냉방성능 실험연구 (Experimental Study on Cooling Performance of A/C applied Fin-tube and PF Heat Exchangers)

  • 권영철;박윤창;권정태;박경만
    • 한국산학기술학회논문지
    • /
    • 제10권8호
    • /
    • pp.1789-1794
    • /
    • 2009
  • 본 연구에서는 핀-관 열교환기와 평행류(PF) 열교환기를 실외 열교환기로 적용한 공조기의 실내외 온도/습도와 같은 환경변화에 대한 냉방성능을 비교 조사하고자 하였다. KS C 9306의 냉방표준 온도조건을 기준으로 핀-관, 2종류의 PF 열교환기를 적용한 공조기 성능변화를 이해하기 위하여 냉방능력과 COP를 획득하였다. 실험을 위해 공기엔탈피 방식의 칼로리미터를 사용하였다. PF 열교환기는 핀-관 열교환기보다 우수한 열전달 능력을 보였다. 그리고 사각형 핀을 적용한 PF형 공조기의 성능이 삼각형 핀의 경우보다 우수하였다. 실내 토출공기의 유속, 실내온도 그리고 실내상대습도가 높아질수록 냉방능력과 COP는 증가를, 실외온도가 높아질수록 냉방능력과 COP는 감소를, 그러나 실외 상대습도 증가에 따른 성능변화는 미미하였다.

지하수 이용을 위한 열교환기 개발. I - 냉각핀의 설계제작 - (Development of heat exchanger by the utilization of underground water. I - Design for plat fin tube -)

  • 이운용;안덕현;김상철;박우풍;강용구;김선배
    • 현장농수산연구지
    • /
    • 제4권1호
    • /
    • pp.119-127
    • /
    • 2002
  • 지하수의 열(15℃)을 농업시설의 난방과 냉방에 사용하기 위하여, 관에 종방향으로 부착되는 plat fin tube 형 알루미늄(Al 6063) 열교환기를 개발하여 알루히트(의장등록 : 0247164)로 명명하였다. 열교환 핀을 관에 종방향으로 배치하여 송풍과 대류에 유체 흐름저항을 최소화 하였으며, 핀표면에 돌기를 만들어 결로와 fouling factor를 감소시켰다. 1. 알루히트의 제원은 관 내경 0.03m, 외경 0.036m, 두께 0.003m이며, 냉각핀의 두께 0.0012m, 핀 길이 0.032m로 하였다. 2. 단위 길이당 관 외부의 전열면적은 1.3946m2이며, 관내부 전열면적은 0.0942m2였고, 내외면적비 Ra = 14.805였다. 3. 핀의 길이 0.032m로 하였을 때, 핀의 효율이 93%정도인 것으로 나타났으며, 핀두께 0.0012m는 h𝛿/k<0.2를 만족하여 적합한 것으로 판단된다. 4. 알루히트의 온수 방열 성능실험에서 열매체의 온도가 높고 유량이 많을수록 방열 열량이 많은 것으로 나타났고, 열매체의 온도 60℃, 유량 10 𝑙/min일 때 방열열량은 504kJ/h·m 였으며, 80℃, 40 𝑙/min일 때는 방열열량이 6,048kJ/h·m로 나타났다. 5. 방열성능에서 각각의 열매체 온도간 상관계수 $R^2_1=0.9898$, 유량간 상관계수 $R^2_2=0.9721$로 실험 데이터를 신뢰할 수 있었다.

설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

태양열을 이용한 일이중 겸용 흡수식 냉온수기 동적성능 모사연구 (A Study of Dynamic Simulation of a Hybrid Absorption Chiller Utilizing Solar Power)

  • 신영기;서정아;우성민;김효상
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.967-972
    • /
    • 2009
  • A dynamic model has been developed to investigate the operability of a single and double-effect solar energy assisted parallel type absorption chiller. In the study, main components and fluid transport mechanism were modeled. And solar radiation and the solar collector also were also modeled along with its control design. The model was run for the single mode with solar energy supply only and the solar/gas driving double effect mode. From the simulation results, it was found that the present configuration of the chiller is not capable of regulating solution flow rates according to variable solar energy input. And the issues of the excessive circulation flowrate and the mismatch between available solar power and cooling load discourages the use of the single mode, but the dual use of gas and solar power is recommendable in view of controllability and enhanced COP.

  • PDF