• 제목/요약/키워드: Parallel-Feeding

검색결과 74건 처리시간 0.026초

교류 AT급전방식에서 병렬급전시 변전소간 전압위상차에 의한 루프전류에 관한 연구 (A Study on the Loop Current Induced by Voltage Phase Difference Substations during Parallel Feeding under the Alternating Current AT Electric Power Feeding Method)

  • 박재석;송중호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.1997-2004
    • /
    • 2011
  • The $2{\times}25kv$ AT electric power feeding method in the A.C. electric train adopts the one-phase power feeding method as the standard due to a voltage phase difference, and the distance between the two neighboring substations is 50km due to voltage drop. The one-phase power feeding method makes the system operation feasible, while making it unfavorable for power supply. Moreover, railroad involves large-capacity single-phase load, and if it is expected to continue to rise, it is necessary to research on measures to stabilize the supply of power to railroad cars with the existing facilities. In this study, a parallel power feeding method between neighboring substations is proposed to stabilize the supply of electric power to electric railroad cars under the 2*25kv AT power feeding method and the loop current induced by voltage phase difference between the two neighboring substations during parallel power feeding is investigated.

  • PDF

A Phase-shifter for Regulating Circulating Power Flow in a Parallel-feeding AC Traction Power System

  • Choi, Kyu-Hyoung
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1137-1144
    • /
    • 2014
  • A parallel-feeding AC traction power system increases the power supply capacity and decreases voltage fluctuations, but the circulating power flow caused by the phase difference between the traction substations prevents the system from being widely used. A circuit analysis shows that the circulating power flow increases almost linearly as the phase difference increases, which adds extra load to the system and results in increased power dissipation and load unbalance. In this paper, we suggest a phase shifter for the parallel-feeding AC traction power system. The phase shifter regulates the phase difference and the circulating power flow by injecting quadrature voltage which can be obtained directly from the Scott-connection transformer in the traction substation. A case study involving the phase shifter applied to the traction power system of a Korean high-speed rail system shows that a three-level phase shifter can prevent circulating power flow while the phase difference between substations increases up to 12 degrees, mitigate the load unbalance, and reduce power dissipation.

병렬급전에서 변전소간 전압위상차 검토 (Study of Phase Difference between Substations in Parallel Feeding Method)

  • 이장무;이한민;오세찬
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.858-863
    • /
    • 2007
  • With increase of load power the case it will not be able to supply the power which is necessary to the vehicle, it establishes dosage increase of main transformer of substation or power compensation equipment, and must supply the power which is necessary. But like this method the expense and the hour when it is considerable are necessary. As an alternative plan, if neighborhood substation can supply power through parallel feeding then it can supply power applying the equipment of existing. So we investigate the possibility of parallel feeding method between neighboring substations through measuring results of voltage phase difference and analysing feeding circuit,

  • PDF

2차 보간법을 이용한 전기철도 급전계통의 고장점 산출 기법에 관한 연구 (A Study on Estimation Technique for Fault Location using Quadratic Interpolation in a Parallel Feeding AC Traction System)

  • 민명환;안태풍;권성일;정호성
    • 전기학회논문지
    • /
    • 제66권3호
    • /
    • pp.599-604
    • /
    • 2017
  • Nowadays reactance method is being used as a technique for fault location in parallel feeding AC traction power system. However, implementation of this method requires a large number of field tests(ground fault) which is a huge burden on the operators. This paper presents a new estimation technique using quadratic interpolation to reduce number of times for field test and improves the accuracy of fault location. To verify a new technique, we solve AT feeding circuit and model it using PSCAD/EMTDC. Finally this paper conducts a comparative analysis of usefulness between a new technique and real field data.

능동형 전압제어를 통한 교류 전기철도 급전망에 대한 전력손실 분석 (A Power Losses Analysis of AC Railway Power Feeding Network using Adaptive Voltage Control)

  • 정호성;김형철;신승권;김진호;윤기용;조용현
    • 전기학회논문지
    • /
    • 제62권11호
    • /
    • pp.1621-1627
    • /
    • 2013
  • This paper compares power losses between voltage controlled before and after using power conversion device in AC feeding system. For this purpose we present voltage control procedures and criteria and model high speed line and train using PSCAD/EMTDC to compare power losses in various feeding condition. Power losses of the simulation result in power control before and after in single point feeding system was reduced maximum 0.37 MW(23.8 %) and average 0.23 MW(20.5 %) when one vehicle load operates maximum load condition. When three vehicles operate maximum load condition in one feeder section, power losses after voltage control was reduced 1.03 MW(49.5%) compared to before voltage control. And, power loss of parallel feeding system is reduced the average 0.08 MW(7.2 %) compared to the single feeding system. In conclusion, adaptive voltage control method using power conversion device can reduce power losses compared with existing method.

A Novel Solid State Controller for Parallel Operated Isolated Asynchronous Generators in Pico Hydro Systems

  • Singh, Bhim;Kasal, Gaurav Kumar
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권3호
    • /
    • pp.358-365
    • /
    • 2007
  • This paper deals with a novel solid state controller (NSSC) for parallel operated isolated asynchronous generators (IAG) feeding 3-phase 4-wire loads in constant power applications, such as uncontrolled pico hydro turbines. AC capacitor banks are used to meet the reactive power requirement of asynchronous generators. The proposed NSSC is realized using a set of IGBTs (Insulated gate bipolar junction transistors) based current controlled 4-leg voltage source converter (CC-VSC) and a DC chopper at its DC bus, which keeps the generated voltage and frequency constant in spite of changes in consumer loads. The complete system is modeled in MATLAB along with simulink and PSB (power system block set) toolboxes. The simulated results are presented to demonstrate the capability of isolated generating system consisting of NSSC and parallel operated asynchronous generators driven by uncontrolled pico hydro turbines and feeding 3-phase 4-wire loads.

커패시터 구조를 급전 루프에 삽입한 광대역 PIFA 안테나 설계 (Design of PIFA with Capacitor Structure Inserted into Feeding Loop)

  • 김승우;박상규;김형동
    • 한국전자파학회논문지
    • /
    • 제21권10호
    • /
    • pp.1103-1108
    • /
    • 2010
  • 본 논문에서는 PIFA의 급전점과 단락점을 둘러싸는 급전 루프 내부에 커패시터 구조를 삽입하는 새로운 타입의 4중 대역(GSM900/DCS/PCS/W-CDMA) PIFA 설계를 제안한다. 커패시터의 삽입을 통해서 병렬 공진점인 2.01 GHz에서의 반사 계수 -2.73 dB를 -6.26 dB로 낮추는 효과를 얻을 수 있었다. 병렬 공진에서의 좋지 못한 방사 특성을 개선시킴으로써 고차 대역(DCS/PCS/W-CDMA)에서의 광대역 특성을 나타내었다.

로타리 킬른의 장입 특성이 온도분포에 미치는 영향 (The Effect of Feeding Characteristics on the Temperature Distribution of Rotary Kiln)

  • 박종석;전철균
    • 한국연소학회지
    • /
    • 제12권3호
    • /
    • pp.24-32
    • /
    • 2007
  • A theoretical model was developed for rotary kiln and computational study was conducted to find the effect of feeding characteristics. One dimensional model with the variations of heating distribution, length of heating zone, excess air ratio and revolution was considered. The comparison of parallel-flow rotary kiln with that of counter-flow was conducted. For parallel-flow type, it is found that the variation of temperature of solid is not great for the zone that is following flame-heating zone. This zone is good to take the special treatment because thermal deviation is small and contacting time is enough for another treatment. Increase of excess air ratio have the effect of decreasing solid temperature. But this effect of decreasing solid temperature goes small for the great excess air ratio. The heating is efficient for the flame which has the maximum heating at the central region of the full length.

  • PDF

Study on Motor Characteristics due to Deviation of the Wheel Diameters with Parallel Operation

  • Lee, Hyung-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권1호
    • /
    • pp.106-109
    • /
    • 2013
  • It is desirable and advantageous to feed parallel propulsion with induction motors by a single voltage source inverter. However, effects of deviation of the wheel diameters on motor current, rotor speed and torque should be also considered for parallel operation. In order to understand the behavior and characteristics, a simple simulation model is developed by using a commercial Matlab Simulink. From the results, it is clear to manage the diameter deviation of the wheels which are connected to traction motors.

교류전기철도 병렬급전 운영을 위한 위상조정장치 제어기법 (A Control Method of Phase Angle Regulator for Parallel-Feeding Operation of AC Traction Power Supply System)

  • 이병복;최규형
    • 한국산학기술학회논문지
    • /
    • 제21권5호
    • /
    • pp.672-678
    • /
    • 2020
  • 교류전기철도 급전시스템에 병렬급전방식을 적용할 경우, 전동차 부하로 인한 전압강하 및 최대순시부하를 감소시켜 급전구간을 연장하고 급전용량을 향상시킬 수 있다는 장점이 있다. 그러나 변전소 간에 위상차가 있을 경우 순환전력이 발생하기 때문에 적용이 제한되며, 전동차 운행에 따른 부하 분포에 따라 변전소 부하 불균형이 커져서 급전용량이 저하되는 문제점이 있다. 본 논문에서는 변전소 위상차 및 전동차 부하분포에 따라 변동하는 순환전력을 실시간 제어하고 변전소 부하 불균형을 해소하기 위하여 사이리스터 제어 위상조정장치 (TCPAR: Thyristor Controlled Phase Angle Regulator, 이하 TCPAR)를 적용하는 방식을 제안하고, 이를 구현하기 위한 검토를 수행하였다. 전기철도 급전 시스템에 TCPAR을 적용하기 위한 제어 기법으로서, 변전소 공급전력을 입력으로 이용하여 변전소 위상차 및 전동차 부하 분포에 따라 변동하는 순환전력과 변전소 부하 불균형을 효과적으로 억제하는 제어모델을 제시하였다. PSCAD/EMTDC를 이용한 시뮬레이션 결과, 전기철도 병렬급전에 제안한 TCPAR을 적용함으로써 변전소 위상차 및 전동차 부하분포에 따라 변동하는 순환전력 및 변전소 부하 불균형을 효과적으로 억제시킬 수 있다는 것을 확인하였다. 제안 기법을 전기철도 병렬급전에 적용할 경우, 병렬급전 적용 범위를 확대하고 급전용량을 증가시킬 수 있을 것으로 기대된다.