• 제목/요약/키워드: Parallel IGBTs

검색결과 17건 처리시간 0.018초

Current Sharing Control Strategy for IGBTs Connected in Parallel

  • Perez-Delgado, Raul;Velasco-Quesada, Guillermo;Roman-Lumbreras, Manuel
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.769-777
    • /
    • 2016
  • This work focuses on current sharing between punch-through insulated gate bipolar transistors (IGBTs) connected in parallel and evaluates the mechanisms that allow overall current balancing. Two different control strategies are presented. These strategies are based on the modification of transistor gate-emitter control voltage VGE by using an active gate driver circuit. The first strategy relies on the calculation of the average value of the current flowing through all parallel-connected IGBTs. The second strategy is proposed by the authors on the basis of a current cross reference control scheme. Finally, the simulation and experimental results of the application of the two current sharing control algorithms are presented.

$\cdot$ 대용량 인버터용 IGBT 병렬 운전 연구 (The Study on Parallel operation of IGBT for the Medium SE the Large capacity Inverter)

  • 박건태;윤재학;정명길;김두식
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.430-433
    • /
    • 2003
  • IGBTS are widely used for the industrial inverters in the mid power range at low voltage (440V$\~$660V) application. Advantageous features of the device are simple gate drive and high speed switching capability. Due to these advantages the application of IGBTS is enlarging into the high power application. However, to increase the power handling capacity at lower input voltage level, the current rating in each bridge arm must be enlarged. Therefore the parallel operation of IGBT devices is essentially needed. This paper describes the feasible parallel structures of the power circuit for the mid & the high power inverters and introduces the important design condition for the parallel operation of IGBT devices. To verify feasibility of the IGBT parallel operation, the feature of several IGBT devices (EUPEC, SEMIKRON's IGBT) are investigated and the power stacks are implemented and tested with these devices. The experimental results show the good characteristics for the parallel operation of IGBTS.

  • PDF

원가절감형 IGBT스택 개발 (Development of IGBT Stacks for Cost Reduction)

  • 홍순찬;강경우;정우창;황용하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.128-132
    • /
    • 2003
  • This paper deals with the development of IGBT stacks for cost reduction. One stack is consist of 4 IGBTS in parallel. In the high- and mid-power converters, IGBT stacks are more suitable than single IGBTS in the aspects of total cost of semiconductor devices, time for purchasing, maintenance, radiation of heat, size of surge absorber and harmonic filter, frequency characteristics, and etc.. Problems accompanied by parallel construction are studied and solved. Economical efficiency is discussed and field tests with 100kVA UPS are tarried out to verify the validity of the developed IGBT stacks.

  • PDF

유도가열기용 직.병렬 공진 고주파 인버터의 설계 (Design of High Frequency Inverter with Series-parallel Load-Resonant for Induction Heating application)

  • 홍순일;손의식
    • 조명전기설비학회논문지
    • /
    • 제14권6호
    • /
    • pp.12-17
    • /
    • 2000
  • IN induction heating system the high frequency operation allows a rapid response to current fluctuation in the inverter and result in improved welding quality. To work induction heating of nonferrous metals, a welding power supply is need high working frequency and high power. This paper is shown design technique for increasing working frequency in induction heating for welding coppers. A series-parallel resonate inverter consists of H-type bridges, each of whose arms is composed of a combination of two parallel IGBTs. Inverter operating with the fixed frequency is controlled by pulse width modulation (PWM). As switching adapted the Zero-Voltage Switching technique to reduce switching losses the system is high efficiency. The propose inverter has feature which is high efficiency for very wide load variations with a narrow range of duty cycle ratio control and load short circuit capability. Detailed experimental results obtained from a 48[V] output, 500[W] experimental inverter are presented to verify the concept.

  • PDF

A Novel Solid State Controller for Parallel Operated Isolated Asynchronous Generators in Pico Hydro Systems

  • Singh, Bhim;Kasal, Gaurav Kumar
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권3호
    • /
    • pp.358-365
    • /
    • 2007
  • This paper deals with a novel solid state controller (NSSC) for parallel operated isolated asynchronous generators (IAG) feeding 3-phase 4-wire loads in constant power applications, such as uncontrolled pico hydro turbines. AC capacitor banks are used to meet the reactive power requirement of asynchronous generators. The proposed NSSC is realized using a set of IGBTs (Insulated gate bipolar junction transistors) based current controlled 4-leg voltage source converter (CC-VSC) and a DC chopper at its DC bus, which keeps the generated voltage and frequency constant in spite of changes in consumer loads. The complete system is modeled in MATLAB along with simulink and PSB (power system block set) toolboxes. The simulated results are presented to demonstrate the capability of isolated generating system consisting of NSSC and parallel operated asynchronous generators driven by uncontrolled pico hydro turbines and feeding 3-phase 4-wire loads.

고속전철 보조전원장치용 PWM 컨버터의 병렬운전에 관한 연구 (A Study on Parallel Operation of PWM Converter for Auxiliary bloc High Speed Train)

  • 송상훈;성재원;김연충;원충연;최종묵;기상우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.358-361
    • /
    • 1999
  • In auxiliary block of high speed train power factor correction and harmonics reduction is very important issue for efficient energy transport. The GTO-equipped PWM converter is used for traction untill resently. But the rising power capability of IGBTs resently allows to build IGBT-equipped PWM converter with a considerably increased switching frequency. This paper presents switching pattern, control method, operation mode and tuned filter to reduce dc link voltage ripple for paralleled converter.

  • PDF

직·병렬 하이브리드 충전 구조를 사용한 배터리 균형 충전 (Battery Cell Balancing with Hybrid Architecture of Serial and Parallel Charging)

  • 정의한;양창주;한승호;김형석
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권4호
    • /
    • pp.609-613
    • /
    • 2016
  • 전기자동차 배터리 셀들 간의 불균형 충전 문제를 해결하기 위해, 직병렬 하이브리드 충전 구조를 개발하였다. 이 방법은 직렬 부분에 의해 주 충전이 수행되며 병렬 부분에 의해 밸런싱이 수행되는데, 이 때, 직렬 부분은 부피가 크고 무겁지만 병렬 부분은 직렬 부분보다 작고 가볍다. 개별 배터리 셀 전압을 측정하기 위한 센서 어레이, 듀티비 제어를 포함한 IGBT, 그리고 배터리 관리 시스템은 제안된 시스템의 핵심 요소이다.

부분 공진형 소프트 스위칭 PWM DC-DC 고전압 컨버터 (Soft-Switched PWM DC-DC High-Power Converter with Quasi Resonant-Poles and Parasitic Reactive Resonant Components of High-Voltage Transformer)

  • 김용주;신대철
    • 전력전자학회논문지
    • /
    • 제4권4호
    • /
    • pp.384-394
    • /
    • 1999
  • This paper deals with a fixed frequency full-bridge inverter type DC-DC high-power converter with high frequency high voltage(HFHV) transformer-coupled stage, which operates under quasi-resonant ZVS transition priciple in spite of a wide PWM-based voltage regulation processing and largely-changed load conditions. This multi-resonant(MR) converter topology is composed of a series capacitor-connected parallel resonant tank which makes the most of parasitic circuit reactive components of HFHV transformer and two additional quasi-resonant pole circuits incorporated into the bridge legs. The soft-switching operation and practical efficacy of this new converter circuit using the latest IGBTs are actually ascertained through 50kV trially-produced converter system operating using 20kHz/30kHz high voltage(HV) transformers which is applied for driving the diagnostic HV X-ray tube load in medical equipments. It is proved from a practical point of view that the switching losses of IGBTs and their electrical dynamic stresses relating to EMI noise can be considerably reduced under a high frequency(HF) switching-based phase-shift PWM control process for a load setting requirements.

  • PDF

Current-Source Pulse Density Modulated Parallel Resonant Inverter with A Single Resonant Snubber and Its Unique Application

  • Wang Y.X.;Koudriavtsev O.;Konishi Y.;Okuno A.;Nakaoka M.;Lee H.W.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.261-265
    • /
    • 2001
  • In this paper, a current-source type parallel indudor compensated load resonant high-frequency soft switching inverter using IGBTs for driving the newly-produced silent discharge type ozone generating tube and excimer lamp for UV generation which incorporate a single switched capacitor resonant snubber between the port in DC busline side is presented, together with its pulse modulated unique output power regulation characteristics.

  • PDF

Optimal Design of a DC-DC Converter for Photovoltaic Generation

  • Kwon, Soon-Kurl
    • 조명전기설비학회논문지
    • /
    • 제25권3호
    • /
    • pp.40-49
    • /
    • 2011
  • This paper presents novel circuit topology of half-bridge soft-switching PWM inverter type DC-DC high power converter for DC bus feeding power plants. The proposed DC-DC power converter is composed of a typical voltage source-fed, half-bridge high frequency PWM inverter with a high frequency planar transformer link PWM control scheme and parallel capacitive lossless snubbers. The operating principle of the new DC-DC converter treated here is described by using switching mode-equivalent circuits, together with its unique features. All the active power switches in the half-bridge arms and input DC bus lines can achieve ZCS turn-on and ZVS turn-off commutation transitions. The total turn-off switching losses of the power switches can be significantly reduced. As a result, high switching frequency IGBTs can actually be selected in the frequency range of 40[kHz] under the principle of soft-switching. The performance evaluations of the experimental setup are illustrated practically.