• Title/Summary/Keyword: Parallel Electrodes

Search Result 127, Processing Time 0.021 seconds

A Study on EMG Signal Processing Using Linear Prediction (선형예측을 이용한 EMG 신호처리에 관한 연구)

  • ;邊潤植;李建基
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.24 no.2
    • /
    • pp.280-291
    • /
    • 1987
  • In this paper, the linear autoregressive model of EMG signal for four basic arm functions was presented and parameters for each function were estimated. The signal identification was carried out using function discrimination algorithm. It was validated that EMG signal was a widesense stationary process and the linear autoregressive model of EMG signal was constructed through approximating it to Gaussian process. It was confined that Levinson-Durbin algoridthm is a more appropriate one than the recursive least square method for parameter estimation of the linear model. Optimal function discrimination was acquired when sampling frequency was 500Hz and two electrodes were attached to bicep and tricep muscle, respectively. Parameter values were independent of variance and the number of minimum data for function discrimination was 200. Bayesian discrimination method turned out to be a better one than parallel filtering method for functional discrimination recognition.

  • PDF

Accurate Prediction Method of Breakdown Voltage in Air at Atmospheric Pressure

  • Kim, Nam-Kyung;Lee, Se-Hee;Georghiou, G.E.;Kim, Dong-Wook;Kim, Dong-Hun
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.97-102
    • /
    • 2012
  • To predict accurately the breakdown voltage in air at atmospheric pressure, a fully coupled finite element analysis combining the hydrodynamic diffusion-drift equations with Poisson's equation is proposed in the current paper. As three kinds of charged transport particles are nonlinearly coupled with spatial electric fields, the equations should be solved by an iterative numerical scheme, in which secondary effects, such as photoemission and photoionization, are considered. The proposed method has been successfully applied to evaluate the breakdown voltage in circular parallel-plane electrodes. Its validity has been proved through the comparison of the predicted and experimental results. The effects of numerical conditions of the initial charge, photoemission, and background ionization on the discharge phenomena are quantitatively assessed through Taguchi's design of experiment method.

Experimental Investigation on the Flow Characteristics of ER Fluids (ER유체의 유동특성에 관한 실험적 연구)

  • 김도태;장성철;최윤대
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.216-221
    • /
    • 1999
  • Electrorheological fluids (ERF) are suspensions which show an abrupt increase in rheological properties under electric fields. The rheological response is very rapid and reversible when the electric field is imposed and/or removed. Therefore, there are many practical applications using the ERF. The purpose of the present study is to examine the flow characteristics of ERF. First, the microscopic behavior of the ER suspension structure between two fixed parallel-plate brass electrodes applied dc high voltage for the stationary and flow of the ERF was investigated by flow visualization. The electrical and rheological properties of zeolite based ERF were reported.

  • PDF

The Analysis of SAW Filter Characteristics Using Ouasi-Static Approximation (Ouasi-Static 근사화에 의한 탄성표면과 필터의 특성 해석)

  • 이동도;정영지;황금찬
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.4
    • /
    • pp.481-489
    • /
    • 1993
  • The charge distribution is calculated to analyze the quasi-static impedance of periodic interdigital transducer taking into account the effect of infinite neighboring electrodes. The charge distribution can be represented by the element factor and array factor. The radiation conductance, susceptance and static capacitance of the input and output IDT's with arbitrary voltages are obtained by the charge distribution. The impedance of apodized IDT, is analyzed by multi-track model in which IDT is represented by the parallel connection of the uniform tracks. The calculated input and output impedances are in good agreement with the experimental results.

  • PDF

Investigation on the Vibration Characteristics of a Symmetric 2DOF Polysilicon Resonator (대칭형 2자유도의 폴리실리콘 공진 구조체에 대한 진동특성 분석)

  • Hong, Yun-Sik;Lee, Jong-Hyeon;Kim, Su-Hyeon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.11
    • /
    • pp.81-87
    • /
    • 2000
  • A new resonator that is fabricated by single polysilicon layer process is presented. The resonator can move in two orthogonal direction on the plane parallel to the substrate. And the resonant frequencies of the two modes are intrinsically designed to be identical since the overall structure of the resonator is symmetric about the two directions of motion. Since the resonator ideally has two identical vibration mode, it can be applied to various micro-devices that requires multi DOF motion, especially to microgyroscopes. To investigate the feasibility of application of the resonator, dynamic model of the resonator including the nonlinear behavior of driving electrodes is derived and evaluated with the fabricated one, and the self-tuning characteristics are proved though experiments.

  • PDF

Development of a Portable ELF Electric Field Meter (휴대용 극저주파 전장측정기 개발)

  • Kil, Gyung-Suk;Song, Jae-Yong;Kim, Il-Kwon
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.2
    • /
    • pp.120-126
    • /
    • 2000
  • This paper dealt with the developed portable electric field meter which consisted of planar-type sensor, analog amplifier with gain controller, A/D convertor, and display unit. The principle of the planar-type sensor for detecting time-varying electric field of extremely low frequency (ELF) bandwidth was described, and a calibration system using cylindrical guard electrodes and parallel-plate electrodes was proposed. From the calibration experiment, the frequency bandwidth and the sensitivity of the developed electric field meter was $17[Hz]{\sim}7[kHz]$, and 4.45[mV/V/m], respectively. Also it can measure the electric field strength up to 10[kV/m], and the measured result was displayed on the liquid crystal display in digit. The electric field meter can be widely applied to measure electric field strength radiated from power lines, computers, and home appliances such as hair dryer, heater, etc.

  • PDF

Frequency-Dependant Grounding Impedances According to the Length of Grounding Electrode and the Joint Position of Ground Conductors (접지전극의 길이 및 접지도선의 접속위치에 따른 접지임피던스의 주파수의존성)

  • Choi, Jong-Hyuk;Choi, Young-Chul;Cho, Sung-Chul;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.5
    • /
    • pp.37-43
    • /
    • 2010
  • When lightning surges with wide frequency spectrum and power converting devices are considered, it is desirable to evaluate grounding system performance by grounding impedances. This paper presents the measured results for frequency-dependent grounding impedance for the vertical grounding electrode and counterpoise on a scale of full size. Grounding impedances of vertical grounding electrodes and counterpoises give capacitive or inductive behaviors according to the length of grounding electrodes and soil resistivity. It is inefficient to extend the length of the grounding electrode in order to decrease the ground resistance, and when designing the grounding system, the consideration of the grounding impedance should be desirable. In order to reduce the grounding impedance of counterpoise, the grounding conductors are jointed at the center of counterpoises. It is effective to reduce the grounding impedance by connecting ground rods to counterpoises in parallel.

Evaluation of Discharge Current Employing Generalized Energy Method and Integral Ohm's Law Using Finite Element Method (유한요소법을 이용한 일반화된 에너지법과 옴의 적분법에 의한 방전 전류 계산)

  • Lee, Ho-Young;Kim, Hong-Joon;Lee, Se-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.2
    • /
    • pp.357-361
    • /
    • 2011
  • The terminal current in voltage driven systems is an essential role for characterizing the pattern of electric discharge such as corona, breakdown, etc. Until now, to evaluate this terminal current, Sato's equation has been widely used in areas of high voltage and plasma discharge. Basically Sato's equation was derived by using the energy balance equation and its final form described physical meaning explicitly. To give more general abilities in Sato's equation, we present a generalized approach by directly using the Poynting's theorem incorporating the finite element method. When the magnetic field effect or the time-dependent voltage source is considered, this generalized energy method can be easily applicable to those problems with any dielectric media such as gas, fluid, and solid. As an alternative approach, the integral Ohm's law resulting in small numerical errors has an ability to be applied to multi-port systems. To test the generalized energy method and integral Ohm's law, first, the results from two prosed methods were compared to those from Sato's approach and an analytic solution in parallel plane electrodes. After verification, the generalized method was applied to the tip-sphere electrodes for evaluating the terminal current with three carriers and the Fowler-Nordheim field emission condition. From these results, we concluded that the generalized energy method can be a consistent technique for evaluating the discharge current with various dielectric materials or large magnetic field.

New Classes of LC Resonators for Magnetic Sensor Device Using a Glass-Coated Amorphous CO83.2B3.3Si5.9Mn7.6 Microwire

  • Kim, Yong-Seok;Yu, Seong-Cho;Hwang, Myung-Joo;Lee, Hee-Bok
    • Journal of Magnetics
    • /
    • v.10 no.3
    • /
    • pp.122-127
    • /
    • 2005
  • New classes of LC resonators for micro magnetic sensor device were proposed and fabricated. The first type LC resonator (Type I) consists of a small piece of microwire and two cylindrical electrodes at the end of the microwire without direct contact to its ferromagnetic core. In type I resonator the ferromagnetic core of the microwire and cylindrical electrodes act as an inductor and two capacitors respectively to form a LC circuit. The second type LC resonator (Type II) consists of a solenoidal micro-inductor with a bundle of soft magnetic microwires as a core. The solenoidal micro-inductors fabricated by MEMS technique were $500\sim1,000\;\mu{m}$ in length with $10\sim20$ turns. A capacitor is connected in parallel to the micro-inductor to form a LC circuit. A tiny glass coated $CO_{83.2}B_{3.3}Si_{5.9}Mn_{7.6}$ microwire was fabricated by a glass-coated melt spinning technique. A supergiant magneto-impedance effect was found in a type I resonator as much as 400,000% by precise tuning frequency at around 518.51 MHz. In type II resonator the changes of inductance as a function of external magnetic field in micro-inductors with properly annealed microwire cores were varied as much as 370%. The phase angle between current and voltage was also strongly dependent on the magnetic field. The drastic increments of magnetoimpedance at near the resonance frequency were observed in both types of LC resonators. Accordingly, the sudden change of the phase angle, as large as $180^{\circ}C$, evidenced the occurrence of the resonance at a given external magnetic field.

Analysis of Parameter Characteristic of Parallel Electrodes Conduction-cooled Film Capacitor for HF-LC Resonance (고주파 LC 공진을 위한 병렬전극 전도냉각 필름커패시터의 파라메타 특성 분석)

  • Won, Seo-Yeon;Lee, Kyeong-Jin;Kim, Hie-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.6
    • /
    • pp.155-166
    • /
    • 2016
  • It is important to configure capacitance(C) of the capacitor and the induction coefficient(L) of the work coil on the resonant circuit design stage in order to induce heating on the object by a precise and constant frequency components in the electromagnetic induction heating equipment. Work coil conducts a direct induction heating according to heating point and area of the object which has a fixed heat factor so that work coil is designed to has fixed value. On the other hands, Capacitor should be designed to be changed in order to be the higher the utilization of the entire equipment. It is extracted the samples by variation of single electrode capacity from the selection stage of raw materials for capacity to the stage of process design for output of the high frequency LC resonance of 700kHz on 1000 VAC maximum voltage and current to $200I_{MAX}$. It is suggested fundamental experiment results in order to prove relation for the optimal design of HF-LC resonance conduction-cooled capacitor based on the response of frequency characteristics and results of output parameters according to variation of the capacitance size.