• Title/Summary/Keyword: Parallel Control

Search Result 2,129, Processing Time 0.028 seconds

Parallel Operation of Three-Phase Four wire UPS using Droop Control (Droop Control을 이용한 3상 4선식 UPS의 병렬운전)

  • Kim, Hyunseob;Han, Jungho;Song, Joong-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.4
    • /
    • pp.88-95
    • /
    • 2013
  • A new droop control method which can be applied to 3-phase 4-wire uninterruptible power supply is proposed in this paper. The droop control method for parallel operation is very attractive one as UPS parallel operation can be carried out without any data communication devices provided among UPS systems connected, but it reportedly shows a PnP(plug-and-play) problem. A basic reason why a circulating current could flow among parallel-connected UPS systems is clearly investigated as well when droop-controlled-ups systems are operated in the manner of PnP. The proposed algorithm is deduced from the investigated result and is basically structured to keep a balanced frequency and balanced voltage profile against power variation. This paper shows that balanced parallel operation of droop control method can be obtained under unbalanced load as well as balanced load conditions when PnP operation is needed and load change occurs.

Control of Parallel Connected Three-Phase PWM Converters without Inter-Module Reactors

  • Jassim, Bassim M.H.;Zahawi, Bashar;Atkinson, David J.
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.116-122
    • /
    • 2015
  • This paper presents a new current sharing control strategy for parallel-connected, synchronised three-phase DC-AC converters employing space vector pulse width modulation (SVPWM) without current sharing reactors. Unlike conventional control methods, the proposed method breaks the paths of the circulating current by dividing the switching cycle evenly between parallel connected equally rated converters. Accordingly, any inter-module reactors or circulating current control will be redundant, leading to reductions in system costs, size, and control algorithm complexity. Each converter in the new scheme employs a synchronous dq current regulator that uses only local information to attain a desired converter current. A stability analysis of the current controller is included together with a simulation of the converter and load current waveforms. Experimental results from a 2.5kVA test rig are included to verify the proposed control method.

Operation Analysis and New Current Control of Parallel Connected Dual Converter System without Interphase Reactors (상간리액터 없는 병렬연결 듀얼컨버터 시스템의 동작해석과 새로운 전류제어)

  • Ji, Jun-Geun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.7
    • /
    • pp.488-493
    • /
    • 2000
  • In this paper, a predictive current control of 12-pulse parallel connected dual converter system without interphase reactors(IPR) is presented. Firstly, the characteristics of system without IPR are analyzed and compared with that of system with IPR. And the predictive current control of this system is discussed. Finally the validity of the presented system and the excellence of the predictive current control response is proved through the simulation results and experimental results.

  • PDF

Optimum Design of a New 4-DOF Parallel Mechanism

  • Chung, Jae-Heon;Yi, Byung-Ju;Kim, Whee-Kuk
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.302-307
    • /
    • 2005
  • Recently, lots of parallel mechanisms for spatial 3-DOF and 6-DOF were investigated. However, research on 4-DOF and 5-DOF parallel mechanisms has been very few. In this paper, we propose a 4-DOF parallel mechanism that consists of 3-rotational and 1-translational motions. The kinematic characteristics of this mechanism are analyzed in terms of an isotropic index and maximum force transmission ratio, and its kinematic optimization is being conducted to ensure enhanced kinematic performances

  • PDF

Parallel Connected High Frequency AC Link Inverters Based on Full Digital Control

  • Sha, Deshang;Guo, Zhiqiang;Deng, Kai;Liao, Xiaozhong
    • Journal of Power Electronics
    • /
    • v.12 no.4
    • /
    • pp.595-603
    • /
    • 2012
  • This paper presents a full digital control strategy for parallel connected modular inverter systems. Each modular inverter is a high frequency (HF) AC link inverter which is composed of a HF inverter and a HF transformer followed by a cycloconverter. To achieve equal sharing of the load current and to suppress the circulating currents among the modules, a three-loop control strategy, consisting of a common output voltage regulation (OVR) loop, individual circulating current suppression (CCS) loops and individual inner current tracking (ICT) loops, is proposed. The ICT loops are implemented with predictive current control from which high precision current tracking can be obtained. The effectiveness of the proposed control strategy is verified by simulation and experimental results from parallel connected two full-bridge HF AC link inverter modules.

Robust Adaptive Control of A HexaSlide Type Parallel Manipulator

  • Kim, Jong-Phil;Kim, Sung-Gaun;Ryu, Jeha
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.3 no.4
    • /
    • pp.262-267
    • /
    • 2001
  • Jeha Ryu Department of Mechatronics, Kwangju Institute of Science and Technology This paper presents an application of a robust adaptive control strategy to HexaSlide type six degrees-of-freedom parallel manipulators. The HexaSlide type parallel manipulators are characterized as an architecture with constant link lengths that are attached to moving sliders on the ground and to a mobile platform. The proposed control law is developed based on a simplified second order system dynamic equation in joint space with uncertain mass, damper, spring, and Coulomb friction terms. These uncertain parameters are updated by an adaptation law that is derived by Lyapunov stability theorem. A robust adaptive control law by using the boundary layer is designed for the purpose of compensating for the neglected dynamic effects of the mobile platform and the six moving links that are modeled as a disturbance term. Experimental results show good and fast tracking performance.

  • PDF

Vibration and precision position control of dual actuators with parallel type piezoactuator (이단 압전 구동기를 가진 이중 구동기의 진동 및 정밀위치제어)

  • Lee, Yong-Gwon;Cho, Won-Ik;Yang, Hyun-Suk;Park, Young-Pil
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.475-480
    • /
    • 2000
  • A new positioning mechanism with Parallel type actuator using piezoelectric material and with dual type actuators using voice coil motor (VCM) and piezoactuator is proposed for optical disk drive or near-field recording type drive, and high speed position and vibration control are investigated. Parallel type bimorph piezoactuator is used as a fine motion actuator with self-sensing technique, which allows a piezoelectric material to concurrently sense and actuate in a closed loop frame work, and positive position feedback control algorithm is adopted to further control residual vibration. For positioning control of VCM, PID control algorithm is adopted.

  • PDF

Implementation of a Parallel Inverted Pendulum System with Decoupling Control (병렬형 역진자 시스템 제작 및 분리제어)

  • 김주호;박운식;최재원
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.7
    • /
    • pp.162-169
    • /
    • 2000
  • In this paper, we develop a parallel inverted pendulum system that has the characteristics of the strongly coupled dynamics of motion by an elastic spring, the time-variant system parameters, and inherent instability, and so on. Hence, it is possible to approximate some kinds of a physical system into this representative system and to apply the various control theories to this system in order to verie their fidelity and efficiency. For this purpose, an experimental system of the parallel inverted pendulum has been implemented, and a control scheme using the eigenstructure assignment for decoupling control is presented in comparison with the conventional LQR optimal control method. Furthermore, this system can be utilized as a testbed to develop and evaluate new control algorithms through various setups. Finally, in this paper, the results of the experiment are compared with those of numerical simulations for validation.

  • PDF

Seamless Mode Transfer of Indirect Current Controlled Parallel Grid-Connected Inverters (간접전류제어방식 병렬형 계통연계 인버터의 무순단 모드절환)

  • Song, Injong;Choi, Junsoo;Lim, Kyungbae;Choi, Jaeho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.5
    • /
    • pp.334-341
    • /
    • 2019
  • This study proposes the control strategy for the seamless mode transfer of indirect current controlled parallel grid-connected inverters. Under the abnormal grid condition, the grid-connected inverter can convert the operation mode from grid-connected to stand-alone mode to supply power to the local load. For a seamless mode transfer, the time delay problems caused by the accumulated control variable error must be solved, and the indirect current control method has been applied as one of the solutions. In this study, the design of control parameters for the proportional-resonant-based triple-loop indirect current controller and the control strategy for the seamless mode transfer of parallel grid-connected inverters are described and analyzed. The validity of the proposed mode transfer method is verified by the PSiM simulation results.

Realization of a Parallel Network System for Image Processing Techniques (영상 처리 기법을 위한 병렬화 네트워크 시스템의 구성)

  • 서원찬;조강현;김우열
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.6
    • /
    • pp.492-499
    • /
    • 2000
  • In this paper, realization techniques of the parallel processing and the parallel network system for image processing are described. The parallel image processing system is constructed by the characterization of image processing and processor. Several problems are solved to achieve effective parallel processing and processor networking with the particular properties of image processing, which are reduction of communication quantity, equalization of load and delay depreciation on communication. A parallel image input device is developed for the flexible networking of parallel image processing. An abnormal region detection algorithm which is the basic function in machine vision is applied to evaluate the constructed parallel image processing system. The performance and effectiveness of the system are confirmed by experiments.

  • PDF