• Title/Summary/Keyword: Parallel/Series-parallel mode

Search Result 75, Processing Time 0.023 seconds

Torque Characteristic Improvement of SRM for Traction Drive using Series-Parallel Winding Connection (직병렬권선방식 전환을 통한 견인용 SRM 토크특성 개선)

  • Kim, Tae-Hyoung;Lee, Dong-Hee;Ahn, Jin-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2008.04c
    • /
    • pp.3-5
    • /
    • 2008
  • This paper presents a hybrid winding connection method for torque characteristics improving of a traction SRM. In order to get a high torque in wide speed range and torque ripple reduction, series and parallel winding connection are changed according to operating speed. From the analysis of torque character operation mode and efficiency, the proposed control scheme is verified.

  • PDF

Derivation of the Timing Constraints for Multi-Sampled Multitasks in a Real-Time Control System (다중샘플링 다중작업을 수행하는 실시간제어시스템의 시계수제한성 유도)

  • 이대현;김학배
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.2
    • /
    • pp.145-150
    • /
    • 1999
  • A real-time control system, composed of the controlled processor and the controller computer(s), may have a variety of task types, some of which have tight timing-constraints in generating the correct control input. The maximum period of those task failures tolerable by the system is called the hard deadline, which depends on not only fault characteristics but also task characteristics. In the paper, we extend a method deriving the hard deadline in LTI system executing single task. An algorithm to combine the deadlines of all the elementary tasks in the same operation-mode is proposed to derive the hard deadline of the entire system. For the end, we modify the state equation for the task to capture the effects of task failures (delays in producing correct values) and inter-correlation. We also classify the type of executing the tasks according to operation modes associated with relative importance of correlated levels among tasks, into series, parallel, and cascade modes. Some examples are presented to demonstrate the effectiveness of the proposed methods.

  • PDF

Scattering and Reception by a Flanged Parallel-Plate Waveguide : TE-Mode Analysis (플란지 평행도파관에 의한 산란 및 수신 : TE-모드 해석)

  • 박타준;엄효준
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.3 no.2
    • /
    • pp.16-21
    • /
    • 1992
  • The TE-mode characteristics of scattering and reception by a flanged parallel-plate waveguide are examined. The technique of the Fourier transform is used to represent the scattered fields in the spectral domain. The simultaneous equations for the transmitted field coefficients are solved to obtain the solution in an asymptotic series form. The numerical computations are performed to illustrate the behaviors of the scattered field and the transmission coefficients versus the aperture size.

  • PDF

Neuro-Fuzzy Identification for Non-linear System and Its Application to Fault Diagnosis (비선형 계통의 뉴로-퍼지 동정과 이의 고장 진단 시스템에의 적용)

  • 김정수;송명현;이기상;김성호
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1998.10a
    • /
    • pp.447-452
    • /
    • 1998
  • A fault is considered as a variation of physical parameters; therefore the design of fault detection and identification(FDI) can be reduced to the parameter identification of a non linear system and to the association of the set of the estimated parameters with the mode of faults. ANFIS(Adaptive Neuro-Fuzzy Inference System) which contains multiple linear models as consequent part is used to model non linear systems. In this paper, we proposes an FDI system for non linear systems using ANFIS. The proposed diagnositc system consists of two ANFISs which operate in two different modes (parallel-and series-parallel mode). It generates the parameter residuals associated with each modes of faults which can be further processed by additional RBF (Radial Basis function) network to identify the faults. The proposed FDI scheme has been tested by simultation on a two-tank system

  • PDF

A Study on the Failure Characteristic of Laminated Composites Joint Containing Two Holes in Series or Parallel (복합적층판의 직병렬 유공 접합부의 파손연구)

  • Kwan-Hyung Song
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.32 no.2
    • /
    • pp.93-102
    • /
    • 1995
  • A series of test was performed by measuring the failure strength and the failure mode of fiber reinforced composite laminates joint containing two holes in Series or Parallel. $[0^{\circ}/45^{\circ}/90^{\circ}/-45^{\circ}]_s$ laminate with W/d(Side distance ratio) 4.0 and E/d(Edge distance ratio) 3.0 has the full bearing strength and are preferable in case of the good efficiency in two series hole. Comparisons were made between testing results and predicting values of the FEM model. Good agreements were fecund between them except the case of $E/d=2{\sim}3$. In the case of $G_h{\geq}3.0d$ and $G_v{\geq}3.0d$ since the interaction coefficients between two parallel holes and between two series holes were small, holes can be treated as independent. The Acoustic Emission(AE) and SEM method were utilized to find out the initial defects, damage and the fracture mechanism.

  • PDF

A Single-Ended Transmitter with Variable Parallel Termination (가변 병렬 터미네이션을 가진 단일 출력 송신단)

  • Kim, Sang-Hun;Uh, Ji-Hun;Jang, Young-Chan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.490-492
    • /
    • 2010
  • A swing level controlled voltage-mode transmitter is proposed to support a stub series-terminated logic channel with center-tapped termination. This transmitter provides a swing level control to support the diagnostic mode and improve the signal integrity in the absence of the destination termination. By using the variable parallel termination, the proposed transmitter maintains the constant output impedance of the source termination while the swing level is controlled. Also, the series termination using an external resistor is used to reduce the impedance mismatch effect due to the parasitic components of the capacitor and inductor. To verify the proposed transmitter, the voltage-mode driver, which provides eight swing levels with the constant output impedance of about $50{\Omega}$, was implemented using a 70nm 1-poly 3-metal DRAM process with a 1.5V supply. The jitter reduction of 54% was measured with the swing level controlled voltage-mode driver in the absence of the destination termination at 1.6-Gb/s.

  • PDF

Development of Novel 3-Phase Line-interactive UPS System using 4-leg PWM Converter/Inverter and AC Reactor (4-레그 PWM 컨버터/인버터와 AC 리액터를 사용한 새로운 3상 라인 인터렉터브 무정전전원장치의 개발)

  • Ji Jun-Keun;Kim Hyo-sung;Sul Seung-Ki;Kim Kyung-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.77-81
    • /
    • 2004
  • In this paper a novel line interactive UPS (Uninterruptible Power Supply) using the two 4-leg VSCs and AC line reactor is proposed. The 4-leg Voltage Source Converter(VSC) can use the DC link voltage effectively by the 3-D SVPWM method. Hence the DC battery voltage can be reduced by $15\%$ in comparison to that of the conventional line-interactive UPS system. One VSC is in parallel with the AC line reactor of the power source side, and the other is in series with the load. The parallel 4-leg voltage source inverter controls three-phase line voltage independently in order to control the line reactor current indirectly. It eliminates the neutral line current and the active ripple power of the source side using the pqr theory so that unity power factor and the sinusoidal source current can be achieved even though both the source and the load voltages have zero sequence components. The series 4-leg voltage source inverter compensates the line voltage and allows the load voltage to be balanced and harmonic-free. Both of parallel and series 4-leg voltage source inverters always act as independently controllable voltage sources, so that three-phase output voltage shows a seamless transition to the backup mode. The feasibility of the proposed UPS system has been investigated and verified through computer simulation results.

  • PDF

Implementation of Zero-Ripple Line Current Induction Cooker using Class-D Current-Source Resonant Inverter with Parallel-Load Network Parameters under Large-Signal Excitation

  • Ekkaravarodome, Chainarin;Thounthong, Phatiphat;Jirasereeamornkul, Kamon
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1251-1264
    • /
    • 2018
  • The systematic and effective design method of a Class-D current-source resonant inverter for use in an induction cooker with zero-ripple line current is presented. The design procedure is based on the principle of the Class-D current-source resonant inverter with a simplified load network model that is a parallel equivalent circuit. An induction load characterization is obtained from a large-signal excitation test-bench based on parallel load network, which is the key to an accurate design for the induction cooker system. Accordingly, the proposed scheme provides a systematic, precise, and feasible solution than the existing design method based on series-parallel load network under low-signal excitation. Moreover, a zero-ripple condition of utility-line input current is naturally preserved without any extra circuit or control. Meanwhile, a differential-mode input electromagnetic interference (EMI) filter can be eliminated, high power quality in utility-line can be obtained, and a standard-recovery diode of bridge-rectifier can be employed. The step-by-step design procedure explained with design example. The devices stress and power loss analysis of induction cooker with a parallel load network under large-signal excitation are described. A 2,500-W laboratory prototype was developed for $220-V_{rms}/50-Hz$ utility-line to verify the theoretical analysis. An efficiency of the prototype is 96% at full load.

Design of Modular DC / DC Converter with Phase-Shifting Topology (위상천이 방식의 모듈형 DC/DC 컨버터 설계)

  • Chai, Yong-Yoong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.1
    • /
    • pp.81-86
    • /
    • 2019
  • This paper is concerned with a system design that enables a the plurality of switching mode power supplies to be supplied with larger power through a parallel connection. For this purpose, a shunt resistor is placed in series at the output of the constant voltage regulator and the output voltage is sensed and controlled using an arduino. In this paper, two constant-voltage regulators were used for the experiment, but it is possible to generalize for more boards. By using the method that controls the system, the sum of the currents delivered by the two systems to the load was found to be 96% of the current drawn from each board. In case of efficiency, 92.4% efficiency is achieved in the unit board and the efficiency in parallel connection is about 90%.

Hybrid thermal seasonal storage and solar assisted geothermal heat pump systems for greenhouses

  • Ataei, Abtin;Hemmatabady, Hoofar;Nobakht, Seyed Yahya
    • Advances in Energy Research
    • /
    • v.4 no.1
    • /
    • pp.87-106
    • /
    • 2016
  • In this research, optimum design of the combined solar collector, geothermal heat pump and thermal seasonal storage system for heating and cooling a sample greenhouse is studied. In order to optimize the system from technical point of view some new control strategies and functions resulting from important TRNSYS output diagrams are presented. Temperatures of ground, rock bed storage, outlet ground heat exchanger fluid and entering fluid to the evaporator specify our strategies. Optimal heat storage is done with maximum efficiency and minimum loss. Mean seasonal heating and cooling COPs of 4.92 and 7.14 are achieved in series mode as there is no need to start the heat pump sometimes. Furthermore, optimal parallel operation of the storage and the heat pump is studied by applying the same control strategies. Although the aforementioned system has higher mean seasonal heating and cooling COPs (4.96 and 7.18 respectively) and lower initial cost, it requires higher amounts of auxiliary energy either. Soil temperature around ground heat exchanger will also increase up to $1.5^{\circ}C$ after 2 years of operation as a result of seasonal storage. At the end, the optimum combined system is chosen by trade-off between technical and economic issues.