• 제목/요약/키워드: Pair Work

검색결과 217건 처리시간 0.03초

有限要素法 에 의한 線型彈性體 의 特定摩擦接觸問題 에 대한 數値解析 (Numerical Analysis of a Class of Contact Problems Involving Friction Effects in Linear Elasticity by Finite Element Methods)

  • 송영준
    • 대한기계학회논문집
    • /
    • 제7권1호
    • /
    • pp.52-63
    • /
    • 1983
  • The purpose of the study is to find development of contact area, contact pressure and friction forces occurring at joints or connection areas inbetween structural members or mechanical parts. The problem has a pair of difficulties intrinsically; a constraint of displacement due to contact, and presence of work term by nonconservative friction force in the variational principle of the problem. Because of these difficulties, the variational principle remains in the form of inequality. It is resolved by penalty method and perturbation method making the inequality to an equality which is proper for computational purposes. A contact problem without friction is solved to find contact area and contact pressure, which are to be used as data for the analysis of the friction problem using perturbed variational principle. For numerical experiments, a Hertz problem, a rigid punch problem, and the latter one with friction effects are solved using $Q_2$-finite elements.

Dual-Band Microstrip Patch Antenna with Switchable Orthogonal Linear Polarizations

  • Kim, Jeongin;Sung, Youngje
    • Journal of electromagnetic engineering and science
    • /
    • 제18권4호
    • /
    • pp.215-220
    • /
    • 2018
  • This study presents a dual-band polarization-reconfigurable antenna that comprises a large square patch with a pair of corner-cut edges and two small square patches with a shorting via. Two PIN diodes are located between the large square patch and two small square patches. Depending on the bias state applied to the two PIN diodes, each small patch may be disconnected or connected to the large square patch. As a result, the proposed antenna can provide polarization reconfigurability between two orthogonal linear polarizations. Further, the proposed antenna operates at 2.51 GHz and 2.71 GHz. From the measured results, the proposed antenna shows a 10 dB bandwidth of 2.39% (2.49-2.55 GHz) and 2.58% (2.68-2.75 GHz). In this work, the frequency ratio can be easily controlled by changing the size of the small patch.

An anomalous dissociation of protonated cluster ions of DNA guanine-cytosine base-pair

  • Seong, Yeon-Mi;Han, Sang-Yun;Jo, Sung-Chan;Oh, Han-Bin
    • Mass Spectrometry Letters
    • /
    • 제2권3호
    • /
    • pp.73-75
    • /
    • 2011
  • In the collisionally-activated dissociation of the proton-bound cluster ions of DNA base guanine (G) and cytosine (C), $G{\bullet}{\bullet}H^+{\bullet}{\bullet}C$, the abundance of [$CH^+$] ions was found to be higher than that of [$GH^+$] despite the fact that G has a higher proton affinity than C. This unexpected observation seems to demonstrate another example that the simple kinetic method scheme does not work. We suggest that a kinetic factor or detailed dynamics governing the proton transfer and dissociation should be carefully considered in the applications of the kinetic method to the proton affinity measurements.

Joint parameter identification of a cantilever beam using sub-structure synthesis and multi-linear regression

  • Ingole, Sanjay B.;Chatterjee, Animesh
    • Structural Engineering and Mechanics
    • /
    • 제45권4호
    • /
    • pp.423-437
    • /
    • 2013
  • Complex structures are usually assembled from several substructures with joints connecting them together. These joints have significant effects on the dynamic behavior of the assembled structure and must be accurately modeled. In structural analysis, these joints are often simplified by assuming ideal boundary conditions. However, the dynamic behavior predicted on the basis of the simplified model may have significant errors. This has prompted the researchers to include the effect of joint stiffness in the structural model and to estimate the stiffness parameters using inverse dynamics. In the present work, structural joints have been modeled as a pair of translational and rotational springs and frequency equation of the overall system has been developed using sub-structure synthesis. It is shown that using first few natural frequencies of the system, one can obtain a set of over-determined system of equations involving the unknown stiffness parameters. Method of multi-linear regression is then applied to obtain the best estimate of the unknown stiffness parameters. The estimation procedure has been developed for a two parameter joint stiffness matrix.

IDENTIFICATION OF RESISTORS IN ELECTRICAL NETWORKS

  • Chung, Soon-Yeong
    • 대한수학회지
    • /
    • 제47권6호
    • /
    • pp.1223-1238
    • /
    • 2010
  • The purpose of this work is to identify the internal structure of the electrical networks with data obtained from only a part of network or the boundary of network. To be precise, it is discussed whether we can identify resistors or electrical conductivities of each link inside networks by the measurement of voltage on the boundary which is induced by a prescribed current on the boundary. As a result, it is shown that the structure of the resistor network can be determined uniquely by only one pair of the data (current, voltage) on the boundary, if the resistors satisfy an appropriate condition. Besides, several useful results about the energy functionals, which means the electrical power, are included.

Polyphase Representation of the Relationships Among Fullband, Subband, and Block Adaptive Filters

  • Tsai, Chimin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1435-1438
    • /
    • 2005
  • In hands-free telephone systems, the received speech signal is fed back to the microphone and constitutes the so-called echo. To cancel the effect of this time-varying echo path, it is necessary to device an adaptive filter between the receiving and the transmitting ends. For a typical FIR realization, the length of the fullband adaptive filter results in high computational complexity and low convergence rate. Consequently, subband adaptive filtering schemes have been proposed to improve the performance. In this work, we use deterministic approach to analyze the relationship between fullband and subband adaptive filtering structures. With block adaptive filtering structure as an intermediate stage, the analysis is divided into two parts. First, to avoid aliasing, it is found that the matrix of block adaptive filters is in the form of pseudocirculant, and the elements of this matrix are the polyphase components of the fullband adaptive filter. Second, to transmit the near-end voice signal faithfully, the analysis and the synthesis filter banks in the subband adaptive filtering structure must form a perfect reconstruction pair. Using polyphase representation, the relationship between the block and the subband adaptive filters is derived.

  • PDF

강휴태차(剛休台車)와 비틀림 응답형태차(答型台車)의 제어특성(制御特性) (Controll Characteristics of Electromagnetically Levitated Rigid Body Bogie-Truck and Twist Response Type of Bogie-Truck)

  • 권병일;정전영개
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 하계종합학술대회 논문집
    • /
    • pp.142-145
    • /
    • 1989
  • The electromagnetic suspension system, which is a kind of magnetic levitation, can be categorized into two groups; separate lift & guidance system and combined lift & guidance system. This paper deals with the latter system, in which lift and guidance forces are generated by a pair of staggered magnets with the inverted U- shaped rail. In this work, a rigid body bogie-truck and a twist response type of bogie-truck, which are constructed by two magnetic wheels consist of two staggered magnet pairs, are modeled, and curvature running characteristics of both types obtained by simulation are presented. Simulation result showed that curvature running characteristics of twist response type of bogie-truck is better than that of rigid body bogie-truck.

  • PDF

직교하는 변형된 골레이(Golay) 코드를 이용한 동시 다중 집속 기반의 초음파 영상 기법 (Ultrasound Imaging Based On Simultaneous Multiple Transmit Focusing Using Orthogonal Modified Golay Code)

  • 김배형;정영관;송태경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.187-190
    • /
    • 2001
  • A new ultrasound imaging technique based on simultaneous multiple transmit focusing using orthogonal modified Golay codes is presented. modified Golay codes are used to increase signal-to-noise-ratio(SNR) and maximize the transmit power efficiency(TPE). Conventional Golay codes consist of a pair of complementary codes with same length and can be compressed into a delta-like signal due to their complementary property. In the present work, two modified Golay codes focused at different depths are transmitted at the same time, which are mutually orthogonal. On receive, these orthogonal modified Golay codes are separately compressed into two short pulses and individually focused. These two focused beam are combined to form a frame of image with improved lateral resolution. Computer simulations are performed to verity the proposed method improves the lateral resolution of image compared with the conventional echo system.

  • PDF

Development of The New Shape Control Algorithm with The Strip Thickness Decoupling in Hot Strip Mill

  • Dukbum Shin;Kim, Jongcheol;Sangchul Won
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.175.2-175
    • /
    • 2001
  • The strip profile and shape control is one of the most important technologies in Hot Rolling Mill System. Because the unbalance of strip´s shape and wave appearance between stands has a bad effect on Hot Rolling Mill System by making the inferior thickness, strip´s damage and so forth in factories. Many competition Plate Mill introduced shape control system, for example, pair cross-mill, work roll bender, which includes shape measuring instruments and shape control mathematical models. Shape meter, which is equipped for flatness, only does feedback control at the top of coil. And, for crown, we depend on initial setup value and there is no feedback control. Therefore we predict the shape of strip using rolling pressure, bender force and tension of inter-stand in ...

  • PDF

Tendon Responses Depending on Different Anatomical Locations

  • Chun, Keyoung-Jin;Robert P. Hubbard
    • Journal of Mechanical Science and Technology
    • /
    • 제17권7호
    • /
    • pp.1011-1015
    • /
    • 2003
  • The objectives of this work focus on the differences in responses of paired tendons from different anatomical locations. Tendon specimens were obtained from the hindlimbs of canines and frozen to -70$^{\circ}C$. After being thawed, specimens were mounted in the immersion bath, preloaded to 0.13N, and then subjected to 3% or 4% of the initial length at a strain rate of 5%/sec. It was found that the mechanical responses of anatomically paired tendons were nearly the same within each pair but different between pairs of tendons from different anatomical locations. Although flexor tendons had much larger cross-sectional area than the others, such as peroneus or extensor tendons, the stiffness of the flexor tendons were much lower than the others throughout their stress-strain responses. The nature and causes of these differences in the stiffness are not fully known. However, it is clear that differences in the mechanical response of tendons and other connective tissues are significant to the musculoskeletal performance.