• Title/Summary/Keyword: Packing efficiency

Search Result 204, Processing Time 0.023 seconds

Comparison of the Mercury Removal Efficiency using TiO2 Powder under Various Light Sources (다양한 광원하에서의 TiO2에 의한 수은제거 효율비교)

  • Lee, Yong-Gyu;Lee, Tai-Gyu;Kim, Woo-Sik
    • Korean Chemical Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.170-175
    • /
    • 2005
  • In this study, mercury was removed by $TiO_2$ using fluorescent light and sunlight, instead of UV lamps. A reactor was specially designed to increase the $TiO_2's$ exposure to the light source and to make the rotational speed constant. The contacting surface area between mercury and adsorbents was increased by packing the adsorption bed with mixture of $TiO_2$ and glass beads. The mercury removal efficiency was more than 99% under all light sources tested in this study. The mercury removal efficiency was more than 99% under the fluorescent light or sunlight which is harmless and cheap or free.

A Study on the Operation Condition for Carbon-Nitrogen Removal in Wastewater and Sludge Reduction using PVA-gel Immobilized Microorganism (PVA-gel 미생물 고정화 담체를 이용한 고도하수처리 및 슬러지 감량화 운전조건 연구)

  • Lee, Jin-Sook;Park, Hyung-Whan;Nam, Duk-Hyun;Park, Chul-Hwi;Jung, In-Ho;Yoo, Young-Kwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.6
    • /
    • pp.875-883
    • /
    • 2006
  • The carbon and nitrogen removal process using PVA-gel (Polyvinyl Alcohol) immobilized microorganisms was studied. The process has been operated under diverse process conditions for 12 months. The process consists of denitrification with internal recycle of 300%, nitrification, aerobic digestion reactors and settling tank. Nitrificatoin and nitrogen removal efficiency according to gel packing ratio and temperature were studied. Yield for Heterotrophs ($Y_H$), decay coefficient for Heterotrophs($b_H$) in aerobic digestion reactor were determined to seize sludge reduction mechanism and compared with typical data of activated sludge process. Then SRT in aerobic digestion reactor was determined on an experimental basis and sludge reduction efficiency was calculated. The process was implemented successfully with sludge reduction efficiency of 92.0~98.5% on a basis of biomass.

A Study on Correlation Peel Strength and the Efficiency of Shingled Modules According to Curing Condition of Electrically Conductive Adhesives (슁글드 모듈에서 경화조건에 따른 ECA 접합강도와 효율의 상관관계에 관한 연구)

  • Jun, Dayeong;Son, Hyoungin;Moon, Jiyeon;Cho, Seonghyeon;Kim, Sung hyun
    • Current Photovoltaic Research
    • /
    • v.9 no.2
    • /
    • pp.31-35
    • /
    • 2021
  • Shingled module shows high ratio active area per total area due to more efficient packing without inactive space between cells. The module is fabricated by connecting the pre-cut cells into the string using electrically conductive adhesives (ECA). ECAs are used for electric and structural connections to fabricate the shingled modules. In this work, we investigated a correlation between ECA peel strength and the efficiency of pre-cut 5 cells module which are fabricated according to ECA interconnection conditions. The curing conditions are varied to determine whether ECA interconnection properties can affect module properties. As a result of the peel test, the highest peel strength was 1.27 N/mm in the condition of 170℃, the lowest peel strength was 0.89 N/mm in the condition of 130℃. The efficiency was almost constant regardless of the curing conditions at an average of 20%. However, the standard deviation of the fill factor increased as the adhesive strength decreased.

Changes of Particle Filtration Efficiency of Cloth Masks by Machine Washing and Cloth Expansion (세탁 및 옷감 신장에 따른 천마스크 제품의 여과효율 변화)

  • Kim, Seung Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.2
    • /
    • pp.115-122
    • /
    • 2017
  • Objectives: This study was designed to evaluate the changes in the particle filtration efficiencies of five cloth masks (4 plate types, 1 cup type) with an increasing number of machine washings and the degree of cloth expansion. Methods: NaCl aerosols were generated using an atomizer and passed through cloth masks in a dynamic aerosol chamber. Particle concentrations were measured both before and after for the cloth masks using an optical particle counter (OPC) in the size range of $0.3{\sim}10{\mu}m$. Results: In the original condition, the filtration efficiencies of the five cloth masks were A: 20.1%, B:30.9%, C: 25.0%, D: 26.5%, and E: 40.9%. As the number of washings increased in the order of one, two, and four times, the filtration efficiencies of cloth mask C increased. The filtration efficiency of A, D, and E increased after the first washing. With the exception of B, the filtration efficiency of cloth masks increased after the second washing and those of all cloth masks increased after the fourth washing. This might be caused by the fibers untangling from the yarn and being freed at one end. In this status, the packing density of the textile will not change, but the distances between fibers will increase, which might bring about an increase in filtration efficiency. When the cloth masks were extended by 10% and 20% in one direction, the filtration efficiencies of cloth masks B, D, and E decreased at 10% extension, and those of all cloth masks decreased at 20% extension. When the cloth masks were expanded by 10% and 20% in two directions, the filtration efficiencies of all cloth masks decreased by at least 34.7% at 10% extension, and by at least 60.9% at 20% extension Conclusions: The filtration efficiency of cloth masks could decrease after one to two machine washings, but will increase after four washings in comparison with their original performances. The filtration efficiency of cloth masks will decrease when they are expanded, such as when stretching over the nose during wearing status.

Simultaneous Removal of $SO_2/NO$ using liquid Homogeneous Catalyst (액상 균일질 촉매를 이용한 $SO_2/NO$ 동시 처리 기술 개발)

  • Jung, Seung-Ho;Bae, Jin-Youl;Park, Don-Hee;Jung, Kyung-Hoon;Cha, Jin-Myeong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.1
    • /
    • pp.62-67
    • /
    • 2007
  • It was investigated to develop the technology for simultaneous removal of $SO_2/NO$ in flue gas using liquid homogeneous catalyst. Test was carried out using a bench scale and a pilot scale experiment. The investigation led to the following results: 1) Removal efficiency of $SO_2$ gas showed good results regardless of operating condition. Removal efficiency of NO gas, however, proportionally increased with higher packing height, lower concentration and larger injection rate of catalyst 2) The optimum design parameters for simultaneous removal of $SO_2/NO$ gas using Fe(II)-EDTA catalyst were as follow: HTU(height of transfer unit) = 0.5 m, liquid gas ratio = 20 $L/m^3$, NTU (number of transfer unit) = 3 stages, cross dimension of scrubber=0.025 $m^2$ 3) The removal efficiencies of $SO_2$ and NO were 95% and 81%, repletely. 4) The high HTU is advantageous on removal of the NO, but the excessive HTU diminishes operating efficiency. Consequently, it is important to decide the HTU of optimum.

Electrolytic Treatment of Ammonium Nitrogen and Nitrate Nitrogen by Bipolar Packed Bed Electrolytic Cell (충전복극전해조에 의한 암모니아성 및 질산성 질소의 전해처리)

  • Yun, Churl-Jong;Yu, Hyun-Chul;Kim, Jung-Sup;Lee, Bong-Seob;Kawk, Myoung-Hwa;Park, Seung-Cho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.7
    • /
    • pp.686-689
    • /
    • 2005
  • This study was conducted to investigate the effect of ammonium and nitrate nitrogen removal to applied voltage, electrolytic time and activated carbon packing height. Batch bipolar packed bed electrolytic cell reactor was packed with $4{\times}8$ mesh granular activated carbon (GAC). Afterward electrolysis was performed in 20 V for 30 min. As a result, as the filling height adjusted to 80 mm high, the removal efficiency of ammonium nitrogen was 99.9%. and as the electrolytic time varied to 60 min, the removal efficiency of ammonium nitrogen was 97.6%. and in case of continuous electrolytic treatment of ammonium and nitrate nitrogen removal efficiency of total nitrogen was over 80% in bipolar packed bed electrolytic cell reactor for 72 hours as the packing height, sample concentration and input rate of sample adjusted to 280 mm, 30 mg/L, 6.7 mL/min, respectively.

Performance characteristics of simultaneous removal equipment for paint particulate matter and VOCs generated from a spraying paint booth (입자상물질과 VOCs 동시제거 실증장치에서 자동차 페인트 부스 발생 paint aerosol과 VOCs의 동시제거 성능 특성)

  • Lee, Jae-Rang;Hasolli, Naim;Jeon, Seong-Min;Lee, Kang-San;Kim, Kwang-Deuk;Park, Young-Ok
    • Particle and aerosol research
    • /
    • v.12 no.4
    • /
    • pp.161-168
    • /
    • 2016
  • The purpose of this study is to determine the performance characteristics of the paint particulate and volatile organic compounds(VOCs) simultaneous removal from the spraying paint booth in the laboratory and real site by sticky paint particulate and VOCs simultaneous removal demonstration unit. The sticky paint particulate and VOCs simultaneous removal unit is composed of the horizontal type pleated filter modules and the zig-zag type granular activated carbon packing modules. The test conditions at the laboratory are $50.15g/m^3$ of average paint aerosol concentration and 300 ppm of VOCs concentration which were same as the working conditions of spraying paint booth in the real site. But, the demonstration conditions at the real site are varied according to the working condition of spraying paint booth for the kind of passenger car bodies. The test results at the laboratory obtained that 99% of total particulate collection efficiency at 0.62 m/min of filtration velocity and 84% at 1.77 m/min of filtration velocity. The VOCs removal efficiencies are 97% at $3500hr^{-1}$ of gas hour space velocity and 59% at $10,000hr^{-1}$ of gas hour space velocity. In the real site test, the average removal efficiency of PM10 was measured to be 99.65%, the average removal efficiency of PM2.5 was 99.38%, the average removal efficiency of PM1 was 98.52%, and the average removal efficiency of VOCs was 89%.

An Experimental study on field application of Permanent form (비탈형 영구거푸집의 현장 적용을 위한 실험적 연구)

  • 정근호;김우재;이영도;정재영;정상진
    • Journal of the Korea Institute of Building Construction
    • /
    • v.1 no.1
    • /
    • pp.143-150
    • /
    • 2001
  • Permanent-Form is one of system forms for reducing human labor, work costs, oscillation, noise, construction wastes and so on. Permanent-Form is made from precast method in facilities, and carried in construction site to assemble with no demolding. The biggest expense to produce permanent-Form is about manufacturing mold. This papers about structural efficiency evaluation, construction efficiency test. The result of this study is below. (1) In the compressive strength test of column. Fly ash specimen and polymer specimen's strength developed as each 8%, 14% to comparison with standard specimen. The reason of this result from form section area increase and form's reinforcing bar (2) The Degree of column crack in permanent form is lower than another one's The glass fiber's fiber reinforcement effect brings like this. (3) In the flexural load test of beam, the early crack load and maximum load of permanent form use specimen showed 20% higher than standard specimen's. (4) In field application experiment, an constructional error is satisfied with the allowable margin of error, $\pm$5mm (5) When the concrete is placed into the form inside, The transformation degree of permanent form is lower than plywood form's. (6) The concrete packing ability of permanent form is satisfactory. (7) The bonding strength of permanent form shows enough strength - 6kgf/$\textrm{cm}^2$.

  • PDF

The Effects of Anthracite Media Sphericity on Filtration Efficiency (안쓰라사이트 여재 원형도가 여과 효율에 미치는 영향)

  • Cheong, Won-suk;Choi, Suing-il
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.6
    • /
    • pp.763-770
    • /
    • 2007
  • There are many design parameters affecting filtration efficiency such as filteration rate, media packing depth, size distribution, and so on. The sphericity, the ratio of the surface area of an equal volume sphere to the real surface area of the particles, is one of major physical characters of media. The effect of sphericity on the performance of anthracite filter has been investigated. Media from eight water treatment plants have been collected. The sphericity of each media has been calculated by using well known headloss equations such as Kozeny equation, Dahmarajah equation etc.. Columns packed with anthracite media having different sphericity have been used to compare headloss development, floc accumulation in the bed, particles in bed water, filtrate turbidities after backwash and so on. The repeated experiments have indicated that the sphericity of anthracite media may not have remarkable influence on the filter performance as it has been suspected. It also has been prospected in the experiment that the media of higher sphericity would store more particles in the bed and give better filtrate quality, if provided that the effective size and the size distribution of media would be the same.

A Patch Packing Method Using Guardband for Efficient 3DoF+ Video Coding (3DoF+ 비디오의 효율적인 부호화를 위한 보호대역을 사용한 패치 패킹 기법)

  • Kim, Hyun-Ho;Kim, Yong-Ju;Kim, Jae-Gon
    • Journal of Broadcast Engineering
    • /
    • v.25 no.2
    • /
    • pp.185-191
    • /
    • 2020
  • MPEG-I is actively working on standardization on the immersive video coding which provides up to 6 degree of freedom (6DoF) in terms of viewpoint. In a virtual space of 3DoF+, which is defined as an extension of 360 with motion parallax, looking at the scene from another viewpoint (another position in space) requires rendering an additional viewpoint using multiple videos included in the 3DoF+ video. In the MPEG-I Visual workgroup, efficient coding methods for 3DoF+ video are being studied, and they released Test Model for Immersive Video (TMIV) recently. This paper presents a patch packing method which packs the patches into atlases efficiently for improving coding efficiency of 3DoF+ video in TMIV. The proposed method improves the reconstructed view quality with reduced coding artifacts by introducing guardbands between patches in the atlas.