• 제목/요약/키워드: PWM patterns

검색결과 62건 처리시간 0.034초

견인전동기 구동용 인버터의 PWM 패턴 해석 (Analysis of PWM Patterns of Inverter fed Traction Motor Drives)

  • 차민;박영진;홍순찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.459-462
    • /
    • 1997
  • This paper presents a optimal PWM patterns, applied to voltage source inverter fed traction motor drives. To derive a PWM patterns of low harmonic characteristic, the analysis and simulations of several PWM techniques are carried out. The acquired PWM patterns can reduce the harmonics and switch the GTOs with low frequency.

  • PDF

전원 고주파분을 최소화하기 위한 콘버어터의 Optimal PWM 제어 (Optimal PWM Control of Converter for Minimizing Sources Harmonic Componets)

  • 임달호;김민수;정동화
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제1권1호
    • /
    • pp.75-82
    • /
    • 1987
  • 종래, 위상제어의 전력전자 회로는 전원에서 고주파분이 많이 포함되고 역율을 저하시키는 원인이 되었다. 그러므로, 본 연구에서는 이러한 영향을 개선시키기 위하여 Optimal PWM 방식을 제시하였다. Optimal PWM 콘버어터는 전원에서 실효 고주파분을 최소화하는 것이며, Optimal PWM 인버어터와 쌍대성이 있음을 알 수 있었다. Optimal PWM 콘버어터의 전류패턴은 Optimal PWM 인버어터의 전압패턴과 같은 스위칭패턴과 제어방법을 얻을 수 있었다. 이러한 PWM방식을 실현하기 위하여 고속 스위칭소자가 필요하게 되었다. 이전에는 강제 전류회로인 싸이리스터가 사용되었으나, 최근에 와서는 전류용 TR 또는 GTO 소자 등을 사용함으로써 이와같은 PWM 특성을 쉽게 실현할 수 있었다. 본 연구에서의 전원에서 실효 고주파 전류를 최소화하기 위한 제어방법, 회로 및 결과를 제시하였다.

  • PDF

3상 매트릭스 컨버터에 사용되는 옵셋전압 PWM 방법과 $V_{max}-V_{mid}$ PWM 방법의 비교분석 (Comparative Analysis of Offset Voltage PWM and $V_{max}-V_{mid}$ PWM Method for 3 Phase Matrix Converter)

  • 차한주;김우중
    • 전기학회논문지
    • /
    • 제58권2호
    • /
    • pp.285-291
    • /
    • 2009
  • In this paper, comparative analysis of offset voltage PWM method and $V_{max}-V_{mid}$ PWM method for three-phase matrix converter is addressed by using a simple analytical and graphical method. Offset voltage PWM method calculates PWM patterns in terms of offset voltage and variable slope of carrier, and it simplifies matrix converter modulation algorithm significantly. $V_{max}-V_{mid}$ PWM method generates patterns by using two phases and maintaining a remaining phase to base phase, and it is implemented in the industrial products. The most important performance criterion of modulation method is a magnitude of current ripples and it is analytically modelled. The graphical illustration of theses complex multivariable functions make per-carrier cycle and per fundamental cycle behavior of two PWM methods understood. Two modulation methods are analysed with the analytical formulas and graphics, and the analysis shows offset voltage PWM method is superior to $V_{max}-V_{mid}$ PWM method with respect to input current ripples and output voltage ripples.

A Unified Carrier Based PWM Method In Multilevel Inverters

  • Nho Nguyen Van;Youn Myung Joong
    • Journal of Power Electronics
    • /
    • 제5권2호
    • /
    • pp.142-150
    • /
    • 2005
  • This paper presents a systematic approach to study the carrier based pulse width modulation (PWM) techniques applied to diode-clamped and cascade multilevel inverters by using multi-modulating patterns. This method is based on the description of controllable redundant parameters in the modulating signals. A unified mathematical formulation is presented for carrier based PWM methods, which obtains outputs similar to the corresponding space vector PWM. A full and separate control of the fundamental voltage, vector redundancies and phase redundancies can be obtained in the carrier based PWM. In this paper, the proposed PWM method and corresponding algorithm for generating multi-modulating signals will be formulated and demonstrated by our simulations.

특정고조파제거기법을 이용한 3상 PWM 인버터의 저차고조파제거 및 스위칭손실 저감에 관한 연구 (Reduction of switching loss and low-order harmonics in three-phase PWM inverter using the selected harmonic elimination)

  • 장철;이병진;윤재성;서윤철;유철로
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.1960-1962
    • /
    • 1998
  • Reference/modulating waveform continuity is not a necessary condition for the implementation of switching patterns for three-phase pulse-width modulated(PWM) converters. This is based on the fact that the converter phase-voltages do not need to be sinusoidal and switching pattern discontinuities do not degrade the quality of output/input voltage/current waveforms by introducing low-order harmonics if certain parameters are optimized. This paper introduces the selected harmonic elimination to reduce the switching frequency and low-order harmonics compared with continuous PWM techniques and some discontinues switching patterns for PWM converter.

  • PDF

FPGA Based PWM Generator for Three-phase Multilevel Inverter

  • ;전태원;김흥근;노의철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.225-227
    • /
    • 2008
  • This paper deals with the implementation on a Field Programmable Gate Array (FPGA) of PWM switching patterns for a voltage multilevel inverter. The reference data in main microcontroller is transmitted to the FPGA through 16 general purpose I/O ports. Herein, three-phase reference voltage signals are addressed by the last 2-bit (bit 15-14) and their data are assigned in remaining 14-bit, respectively. The carrier signals are created by 16-bit counter in up-down counting mode inside FPGA according to desirable topology. Each reference signal is compared with all carrier signals to generate corresponding PWM switching patterns for control of the multilevel inverter. Useful advantages of this scheme are easy implementation, simple software control and flexibility in adaptation to produce many PWM signals. Some simulations and experiments are carried out to validate the proposed method.

  • PDF

실시간 최적 제어가 가능한 새로운 직접 디지탈 PWM기술 (A new real-time optimal direct digital PWM technique)

  • 황재호;최익;권순학;박귀태
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.1265-1268
    • /
    • 1996
  • This paper describes a new pulse width modulation (PWM) scheme suitable for microprocessor-based PWM inverters. Optimal switching patterns minimizing the performance index corresponding to the distortion factor are decided in real time by numerical calculation using the microprocessor-implemented control system. This PWM method is compared with conventional methods, such as the natural PWM and the direct PWM. Harmonic analysis using digital simulations shows that the proposed PWM scheme has much less low-order harmonics than the other methods. The validity of this method is verified in experiments using a microprocessor-based control system, where a 16-bit single-chip microcontroller, Intel 80c196kc is used.

  • PDF

비대칭형 PWM 교류쵸퍼의 기본파 전압제어 및 고조파 전압제거 (Asymmetrical PWM Technique with Fundamental Voltage Control and Harmonic Voltage Elimnation in AC Choppers)

  • 장도현;최규하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.1067-1070
    • /
    • 1992
  • Optimal Asymmetrical Pulse-width Modulated (APWM) technique for ac chopper is proposed which can improve the input power factor and eliminate the harmonics of output voltage up to a specified order, and also enables linear control of the fundamental component of the output voltage. The PWM switching patterns at the specified phase angle are obtained by Newton-Raphson method and theoretical comparisons are made with other PWM and APWM technique.

  • PDF

PWM 제어형 Cycloconverter (PWM Controlled Cycloconverter)

  • 이종무;구헌회;김영석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 하계종합학술대회 논문집
    • /
    • pp.518-521
    • /
    • 1989
  • Recently, PWM cycloconverters that are frequency conversion system have been studied for eliminating do links of conventional converter and inverter systems. A new real-time method for generating PWM patterns is proposed in this paper. This method realizes sinusoidal input and output currents, controllable input displacement factor regardless of load power factor, and maximum output voltage range. Finally, feasibility of the proposed method is confirmed by simulation and experiments.

  • PDF

인버터 폴트 (B4) 환경 하에 토크리플 절감을 위한 개선된 변조방식 (Improved PWM for reducing torque ripple in PMSM with B4 inverter)

  • 박진식;정신명;윤명중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.292-294
    • /
    • 2006
  • This paper presents a study on the use of improved space-vector modulation of VSI employing only four switches, four body diodes. Different switching sequence strategy for vector control for inverter fault mode are described. The influence of different switching patterns at same modulation index and improved PWM method is proposed. The proposed PWM is compared with conventional PWM. Simulation and experimental results are presented.

  • PDF