• 제목/요약/키워드: PWM VSI

검색결과 72건 처리시간 0.022초

영전압 스위칭을 위한 공진형인버터에 관한 연구 (A Study on the Resonant Inverter for Zero Voltage Switching)

  • 정연택;김원철;전지용;노진호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.1147-1149
    • /
    • 1992
  • A novel 3$\phi$ ZVS PWM VSI topology employing a simple dc bus subcircuit that provides soft switching commutations is proposed in this paper. The main advantage of the proposed inverter commutation schem is that the dc bus subcircuit is activated only when required, that is, when dictated by the respective PWM. Detailed analysis is provided and simmulation results are presented to verify the principles of operation of the proposed inverter schem.

  • PDF

속도센서 없는 유도전동기 제어를 위한 고정자 전압 추정 (A Novel Estimation of State Voltage for the Sensorless Control of Induction Motors)

  • 임홍선;이상훈;하인중;홍복영;장상돈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.471-475
    • /
    • 1997
  • PWM-VSI based ac-drives have high nonlinearity due to dead-time in the inverter and the voltage drop across the switching devices. In this paper, we introduced a new nonlinear model of PWM-VSl including parastic capacitor and also showed validity of the model by circuit simulations and experiments. Furthermore, we proposed an on-line identification algorithm for the uncertain model parameters.

  • PDF

DSP-Based Simplified Space-Vector PWM for a Three-Level VSI with Experimental Validation

  • Ramirez, Jose Dario Betanzos;Rivas, Jaime Jose Rodriguez;Peralta-Sanchez, Edgar
    • Journal of Power Electronics
    • /
    • 제12권2호
    • /
    • pp.285-293
    • /
    • 2012
  • Multilevel inverters have gained attention in high-power applications due to their numerous advantages in comparison with conventional two-level inverters. In this paper a simplified Space-Vector Modulation (SVM) algorithm for a three-level Neutral-Point Clamped (NPC) inverter is implemented on a Freescale$^{(R)}$ DSP56F8037. The algorithm is based on a simplification of the space-vector diagram for a three-level inverter so that it can be used with a two-level inverter. Once the simplification has been achieved, calculation of the dwell times and the switching sequences are carried out in the same way as for the two-level SVM method. Details of the hardware design are included. Experimental results are analyzed to validate the performance of the simplified algorithm.

STATCOM의 출력전압 구현방식에 따른 동특성 해석 (The Dynamic Characteristics Analysis of the STATCOM According to the Realization of the STATCOM Output Voltage)

  • 김선호;원동준;한학근;이송근;문승일
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권7호
    • /
    • pp.323-331
    • /
    • 2000
  • Recently Advanced Static Var Compensators(ASVC) or STATic Synchronous COMpesator(STATCOM) has been considered as a next generation reactive power controller. The STATCOM is a voltage source inverter(VSI) based on the static VAr compensator with only small capacitors on the dc side. The main function of the STATCOM is to keep the bus voltage magnitude at the desired value. This paper compared the PAM STATCOM with the PWM STATCOM. The characteristics and the control method of each model is analyzed. And the simulation of STATCOMs based on the above two methods is presented.

  • PDF

Voltage Source Inverter Drive Using Error-compensated Pulse Width Modulation

  • Chen, Keng-Yuan;Hu, Jwu-Sheng;Lin, Jau-Nan
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.388-397
    • /
    • 2016
  • An error-compensated pulse width modulator (ECPWM) is proposed to improve the baseband harmonic performance and the switching loss of voltage source inverters (VSIs). Selecting between harmonic distortion and switching loss is a design tradeoff in the conventional space vector pulse width modulation. In this work, an accumulated difference in produced and desired phase voltages is considered to adjust the reference signal. This mechanism can compensate for the voltage error in the previous carrier period. With error compensation every half-carrier period, the proposed ECPWM allows one-half reduction in carrier frequency without scarifying baseband harmonic distortion. The proposed modulator is applied to a three-phase VSI with R-L load and a motor-speed-control system for experiments. The measured efficiency and operating temperature of switches confirm the effectiveness of the proposed scheme.

새로운 능동형 커먼 모드 전압 감쇄기를 이용한 고주파 누설전류 억제 (The suppression of high frequency leakage current using a new active Common Mode Voltage Damper)

  • 구정회;빈재구;박성준;김철우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.151-154
    • /
    • 2001
  • This paper propose a new active common-mode voltage damper circuit that is capable of suppressing a common-mode voltage produced in the PWM VSI. The new active common mode voltage damper is consisted of a half-bridge inverter and a common mode transformer with a blocking capacitor. Principle of the active common mode damper is as follow; by applying the compensation voltage which has the same amplitude and opposite polarity to the PWM inverter system. So, common mode voltage and high frequency leakage current can be reduced. Simulated and experimental results show that common-mode voltage damper makes contributions to reducing a high frequency leakage current and common-mode voltage.

  • PDF

Fault Diagnosis of a Voltage-Fed PWM Inverter for a Three-parallel Power Conversion System in a Wind Turbine

  • Ko, Young-Jong;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • 제10권6호
    • /
    • pp.686-693
    • /
    • 2010
  • In this paper, a fault diagnosis method based on fuzzy logic for the three-parallel power converter in a wind turbine system is presented. The method can not only detect both open and short faults but can also identify faulty switching devices without additional voltage sensors or an analysis modeling of the system. The location of a faulty switch can be indicated by six-patterns of a stator current vector and the fault switching device detection is achieved by analyzing the current vector. A fault tolerant algorithm is also presented to maintain proper performance under faulty conditions. The reliability of the proposed fault detection technique has been proven by simulations and experiments with a 10kW simulator.

SVPWM 방식 마이크로소스로 구성된 마이크로그리드 모델링 및 해석 (Modeling and Analysis of the Micro-Grid with SVPWM Micro-Sources)

  • 손광명;이계병;김영섭
    • 조명전기설비학회논문지
    • /
    • 제20권3호
    • /
    • pp.12-19
    • /
    • 2006
  • 마이크로소스는 1[kW]${\sim}$수[MW] 사이의 전력을 공급하고, 기존의 대규모 발전설비보다 높은 신뢰도와 에너지 효율을 가지는 고품질의 전력을 공급할 수 있다. 본 논문에서는 마이크로소스의 스위칭레벨 모델을 개발하였으며, 다수의 마이크로소스가 전력시스템과 연계되어 마이크로그리드를 형성할 경우의 특성에 대하여 연구하였다. 마이크로소스는 인버터의 효율을 극대화 할 수 있도록 공간벡터 펄스폭변조(Space Vector PWM, SVPWM) 기법을 채용하였으며, 마이크로소스의 제어시스템 파라미터 특성 및 마이크로소스 상호작용에 관하여 연구하였다. 마이크로소스는 PSCAD/EMTDC를 이용하여 구현하였으며 이를 이용해 마이크로그리드를 구성하여 시뮬레이션하였다. 사례 연구를 통하여 제안된 모델의 효용성을 확인하였다.

PSCAD/EMTDC를 미용한 계통연계형 태양광발전시스템의 모델링 및 모의 해석 (PSCAD/EMTDC Based Modeling and Simulation Analysis of a Grid-Connected Photovoltaic Generation System)

  • 전진홍;김응상;김슬기
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권3호
    • /
    • pp.107-116
    • /
    • 2005
  • The paper addresses modeling and analysis of a grid-connected photovoltaic generation system (PV system). PSCAD/EMTDC, an industry standard simulation tool for studying the transient behavior of electric power system and apparatus, is used to conduct all aspects of model implementation and to carry out extensive simulation study. This paper is aimed at sharing with the PSCAD/EMTDC user community our user-defined model for PV system applications, which is not yet available as a standard model within PSCAD/EMTDC. An equivalent circuit model of a solar cell has been used for modeling solar array. A series of parameters required for array modeling have been estimated from general specification data of a solar module. A PWM voltage source inverter (VSI) and its current control scheme have been implemented. A maximum power point tracking (MPPT) technique is employed for drawing the maximum available energy from the PV array. Comprehensive simulation results are presented to examine PV array behaviors and PV system control performance in response to irradiation changes. In addition, dynamic responses of PV array and system to network fault conditions are simulated and analysed.

캐리어를 이용한 매트릭스 컨버터의 전압 변조 방법 (Carrier-based Modulation Method for Matrix Converter)

  • 윤영두;설승기
    • 전력전자학회논문지
    • /
    • 제10권6호
    • /
    • pp.543-549
    • /
    • 2005
  • 본 논문에서는 캐리어(Carrier)를 이용한 매트릭스 컨버터(Matrix Converter)의 전압 변조 방법을 제안한다. 출력상전압에 적절한 옵셋(Offset) 전압을 더하고, 캐리어 파형의 기울기를 적절히 제어함으로써 입력 전류를 역율 1의 정현파로 제어하면서 동시에 출력 전압의 합성이 가능하다. 이 방법은 기존의 매트릭스 컨버터 전압 변조 방법인 SVPWM과 동일한 스위칭 패턴을 나타내지만, 그 구현은 훨씬 간단한다. 또한 기존의 전압형 인버터(Voltage Source Inverter, VSI)에서 발전된 2상/3상 변조, 과변조(Over Modulation) 등의 개념을 유사하게 적용할 수 있어 그 활용도가 매우 논다. Matlab/Simulink를 이용한 시뮬레이션 결과와 실험을 통해 제안된 방법의 타당성을 검증하였다.