• Title/Summary/Keyword: PWM Method

Search Result 1,342, Processing Time 0.026 seconds

Output Voltage Increment of a PWM Inverter by The Harmonic Injection Method (고조파 주입에 의한 PWM 인버터의 출력전압 증대)

  • 박민호;홍순찬;정근진
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.5
    • /
    • pp.362-369
    • /
    • 1989
  • A method to increase the output voltage of the PWM inverter within linear range is considered. A new modulation wave is used, which is made by injecting the third harmonic wave into the sinusoidal wave. The optimum region for improving the output voltage keeping the linear control characteristic is obtained by digital simulation. Furthermore, the distortion factor in the optimum region is less than that calculated when the maximum output voltage can be obtained in the sinusoidal PWM inverter.

  • PDF

Performance Comparison of Common-Mode Voltage Reduction Methods in terms of Modulation Index (변조지수에 따른 공통모드 전압 저감 기법 성능 비교)

  • Heo, Geon;Park, Yongsoon
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.106-108
    • /
    • 2020
  • This paper introduces a new pulse-width modulation (PWM) method to reduce common-mode voltages (CMVs) and compare its performance with other reduced CMV-PWM (RCMV-PWM) methods. To avoid the use of zero-vectors which cause high CMV peaks, the introduced method splits every reference vector into two vectors such that the peak-to-peak magnitude of CMV is reduced by one-third of conventional space-vector PWM (SVPWM). The performance of RCMV-PWMs altered by the modulation index are analyzed with simulation results.

  • PDF

Control of the Third Harmonics Injected PWM Inverter in Over Modulation Mode (과변조 영역에서의 3고조파 주입형 PWM 인버터 제어)

  • 김영렬
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.1
    • /
    • pp.101-110
    • /
    • 2002
  • A method to control the inverter output voltage lineally in over modulation mode of the third harmonics injected PWM inverter is proposed. The third harmonics injected PWM has a extended linear region compared with the sine PWM. But it still has a maximum voltage about 90% compared with the six step inverter. Therefore, to control the output voltage linearly in over modulation mode, analyzing the relationship between the modulation index and the peak of the fundamental component of the modified reference voltage, we can settle the problem in over modulation mode without iteration. Then we can increase the maximum fundamental component of the third harmonics injected PWM inverter comparative to six-step inverter continuously in over modulation mode. The simulation results of the inverter-induction motor system shows the validity of this method and experimental results prove it.

Space Vector PWM Method for Leakage Current Reduction and NP Current Control in 3-phase 3-level Converter used in Bipolar DC Distribution System (양극성 DC 배전용 3상 3-레벨 컨버터의 누설전류 저감과 NP 전류 제어를 위한 공간벡터 PWM 방법)

  • Lee, Eun-Chul;Choi, Nam-Sup;Kim, Hee-Jun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.5
    • /
    • pp.336-344
    • /
    • 2018
  • This study proposes a new PWM method for leakage current reduction and neutral point (NP) current control in three-phase three-level converter employed in bipolar DC distribution systems. The proposed PWM method uses medium vectors only when there is no need to control the NP current. Thus, common mode voltages are held constant to realize zero leakage current. Some space vectors that produce low-frequency common mode voltages are employed to minimize leakage currents when the average NP current needs to be a positive or negative value. The proposed space vector PWM is implemented based on barycentric coordinate. The validity of the proposed PWM method is verified by simulations and experiments.

The Compensation Method of the Modulation-delay for the Voltage type Dual PWM Converter and Composition of the Instantaneous Current Controller (전압형 Dual PWM 컨버터의 변조각 지연에 따른 보상법 및 순시전류 제어기 구성)

  • Chung, Yon-Tack;Kim, Won-Chul;Lee, Sa-Young;Chun, Ji-Yong;Kim, Hyeun-Bong;Lee, Keun-Hong
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.369-372
    • /
    • 1994
  • In this paper, a voltage type dual PWM converter which achives the bidirectional power flow between a AC supply and a DC bus voltage is described. In PWM modulator, there exist a time difference between the sampling time and carrier wave, it achieves stable modulation even the disturbance in the synchronous AC source voltage. And this paper proposes the compensation method and the control method related a disturbance of synchronous signal using the low pass filter and phase shifter for the stable modulation. As a result the voltage type dual PWM converter makes the imput current wave as sinusoid, and performs the high power factor driving.

  • PDF

Forecasting technics for variable frequency control of PWM inverter using one-chip $\mu$-com (One-chip $\mu$-com을 이용한 PWM 인버터의 가변 주파수 제어 추정 기법)

  • Park, Jung-Gyun;Kim, Hyun;Choi, Hyun-Young;Yeo, Duk-Gu;Oh, Se-Ho;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1055-1057
    • /
    • 2001
  • The switching circuit of PWM inverter is very complicated. By using one-chip $\mu$-com the complication of switching circuit is possible to be diminished. But because in one-chip $\mu$-com the limitation of processed memory size exists, the switching handling method has to be simple. In this paper, to effectively utilize the switching handling, we presented the estimation method of PWM pulses which is different form the conventional PWM switching method by the comparison.

  • PDF

Study on Hybrid PWM Method under Low Switching Frequency

  • Kekang, Wei;Zheng, Trillion Q.;Wang, Ran;Wang, Chenchen
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.2
    • /
    • pp.64-69
    • /
    • 2012
  • This paper presents a hybrid pulse width modulation (PWM) method under low switching frequency conditions based on space vector PWM (SVPWM) and selective harmonic eliminated PWM (SHEPWM), which use asynchronous carrier modulation SVPWM at low frequency, and SHEPWM at high frequency, a square wave after rated conditions. A transitive strategy is proposed to realize a smooth transition of individual modes including SVPWM, SHEPWM and square waves. Experimental results confirm this hybrid modulation method and their transition are reasonable and proper.

NTV 식별과정 없는 멀티레벨 인버터의 신속한 공간벡터 PWM 변조기법

  • Oh, Jin-Seok;Lee, Jong-Ho;Jin, Sun-Ho;Kwak, Jun-Ho;Jo, Kwan-Jun;Kim, Jong-Do
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.253-254
    • /
    • 2006
  • this paper suggest a new space vector PWM modulation method with short processing time which does not need idenfication of nearest three vectors(NTV) and duty calculation for each vector. The suggested PWM method makes mean value of phase voltage to be same as reference during every modulation period by use of a triangle in small hexagon on multi-level vector space. This paper described the suggested modulation method can be successfully applied to the space vector modulation use of multi-level inverter by computer simulations and experiments.

  • PDF

The Simple Harmonic Analysis Method of the Multi-Carrier PWM Techniques by Using the Output Phase Voltage in the Multi-Level Inverter (출력 상전압을 이용한 멀티-캐리어 PWM 기법의 간단한 고조파 분석 방법)

  • 김준성;김태진;강대욱;현동석
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.7
    • /
    • pp.352-360
    • /
    • 2003
  • This paper deals with a simple method in order to analyze and compare the harmonic characteristics in the multi-level inverter. Generally, the magnitude of harmonic components becomes different according to the multi-carrier Pulse Width Modulation(PWM) techniques, the modulation index($M_i$) and the switching frequency The previous papers analyzed the harmonic characteristics from the viewpoint of the space voltage vector. Hence, the calculation of the harmonic vector becomes more difficult and complex in 4-level or over 5-level. However, the proposed method has reduced an amount of calculation and simplified the process of it, using the relationship between the reference voltage and the output phase voltage to the load neutral point. It is applied to the 5-level cascade inverter and the harmonic characteristics for each multi-carrier PWM technique are compared through the simulation.

Study on the Improvement of utility factor for output voltage on 3-phase PWM Inverter (3상 PWM인버어터 출력전압 이용률 개선에 관한 연구)

  • 박성준;변영복;김광태;권순재;김철우
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1995.10a
    • /
    • pp.101-104
    • /
    • 1995
  • The linear control of DC Link voltage in PWM inverter is very importent to estimate the goodness of PWM method. In motor control system, for the maximum torque on full region operating, the whole of DC Link voltage region must be used. 3 phase sinusoidal PWM inverter has a low efficienty at the using of output voltage. according to make better the efficiency, new improved PWM control method is proposed. The results of experimentation and simulation are included to verify the validity of this method.

  • PDF