• Title/Summary/Keyword: PWM Inverter

Search Result 1,383, Processing Time 0.033 seconds

Control of the Third Harmonics Injected PWM Inverter in Over Modulation Mode (과변조 영역에서의 3고조파 주입형 PWM 인버터 제어)

  • 김영렬
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.1
    • /
    • pp.101-110
    • /
    • 2002
  • A method to control the inverter output voltage lineally in over modulation mode of the third harmonics injected PWM inverter is proposed. The third harmonics injected PWM has a extended linear region compared with the sine PWM. But it still has a maximum voltage about 90% compared with the six step inverter. Therefore, to control the output voltage linearly in over modulation mode, analyzing the relationship between the modulation index and the peak of the fundamental component of the modified reference voltage, we can settle the problem in over modulation mode without iteration. Then we can increase the maximum fundamental component of the third harmonics injected PWM inverter comparative to six-step inverter continuously in over modulation mode. The simulation results of the inverter-induction motor system shows the validity of this method and experimental results prove it.

Cost Effective Quasi-Resonant Soft Switching PWM High Frequency Inverter With Minimum Circuit Components for Consumer IH Cooker and Steamer

  • Sugimura, Hisayuki;Eid, Ahmad-M.;Nakaoka, M.;Lee, H.W.
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.134-139
    • /
    • 2005
  • This paper presents a cost effective quasi-resonant soft-switching PWM high frequency inverter with minimum circuit components. This inverter can achieve wider soft commutation, simpler power circuit configuration, smaller volumetric size, lower cost and wider power regulation range, higher-efficiency as compared with single ended quasi-resonant ZVS-PFM inverter and active voltage clamped quasi-resonant ZVS-PWM inverter. The operation principle of the proposed inverter is described on the basis of the simulation and experimental results, together with its operating performances in steady state. The operating performances of this unique proposed high frequency inverter based on ZVS and ZCS arms-related soft commutation principle is evaluated and discussed as compared with the active voltage-clamped ZVS-PWM inverter and a conventional single-ended ZVS-PFM inverter. The practical effectiveness of a novel type quasi-resonant soft-switching PWM high frequency inverter using IGBT is actually proved for consumer induction heated appliances as rice cooker, hot water producer, steamer and super heated steamer. The extended bidirectional circuit topology of quasi-resonant PWM high frequency inverter with minimum circuit components is demonstrated, which operate as the direct frequency changer.

  • PDF

A study on digital PWM control of $3{\Phi}$ voltage-type inverter (3상 전압형 인버터의 디지털 PWM 제어에 관한 연구)

  • Seul, Nam-O;Kim, Young-Min
    • Proceedings of the KIEE Conference
    • /
    • 1998.07b
    • /
    • pp.585-587
    • /
    • 1998
  • It is suggested that the PWM inverter is controlled by Digital Software Programming. VVVF(Variable Voltage Variable Frequency) inverter control being used by PWM control for driving the motor with speed-varying, makes the PWM pattern with calculating the output voltage and frequency, and with controlling the carrier and signal, so actually this method is difficult to correspond with driving the motor by using voltage-varying and frequency-varying. Therefore this research suggested the new algorithm controlled by micro processor which is already stored by various PWM form of output voltage by using fundamental data of the carrier and signal. The PWM wave can be controlled with real time by using extra hardware and digital software and to speed up program processing, the control signals to switch the power semi-conductor of three phase PWM inverter, simultaneously use the output signal by microprocessor and extra hardware, and control signal by software. In the end, this method was proved by applying to Three Phase Voltage-type Inverter.

  • PDF

Evaluation of Trapezoidal PWM Inverter using a new Harmonic Torque Factor (새로운 고조파 토오크 평가함수에 의한 Trapezoidal PWM 인버터의 평가)

  • Lee, Chi-Hwan;Koo, Bon-Ho;Kwon, Wu-Hyen
    • Proceedings of the KIEE Conference
    • /
    • 1987.07a
    • /
    • pp.754-756
    • /
    • 1987
  • In this paper, a new Harmonic Torque Factor(HTF) that represents torque ripple of induction motor is proposed. Trapezoidal PWM is analyzed to torque ripple by HTF and than we obtain optimum triangular factor at some carrier ratio. Six-step, sinusoidal PWM and Trapezoidal PWM are compared and evaluated for choosing a good control strategy of PWM inverter. It turns out that six-step inverter is better than sinusoidal PWM and Trapezoidal PWM when their carrier ratio is 9, and Trapezoidal PWM is superior to sinusoidal PWM. At induction motor is driven by PWM inverter, torque ripples are investigated by computer simulation using d-q two axis model. It is proved that a new Harmonic Torque Factor ix valid.

  • PDF

Ripple Voltage Compensation Instantaneous Follow Controller of Inverter by using Analog Integrator (아날로그 적분기를 이용한 맥동전압 보상형 순시추종 PWM 제어기를 적용한 인버터)

  • 라병훈;이현우;김광태
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.381-389
    • /
    • 2004
  • In this paper, it is suggested that instantaneous compensation PWM control for inverter without the smoothing capacitor Therefore, this inverter system has several advantages. It has small volume and low price to manufacture, decrease trouble rate of inverter, and has power factor correction effect because huge smoothing capacitor-less. And it has compact size control circuit to use analog integrator device. It could make the smoothing capacitor-less inverter for air-blower motor by using the instantaneous compensation PWM controller. This inverter system has small volume and value compare with the conventional VVVF control inverter.

A Study on Double Sinusoidal Modulated PWM Inverter (2중 정현파 PWM 인버어터에 관한 연구 (上))

  • 차득근
    • Journal of the Korean Professional Engineers Association
    • /
    • v.22 no.4
    • /
    • pp.12-16
    • /
    • 1989
  • This paper presents a n analysis of the output voltage waveforms of the double sinusoidal modulated PWM inverter, and are studied on the driving characteristics through the 3 phase induction motor using 6502 microcomputer. The double sinusoidal modulated waves are produced during the interval 4$\pi$/3 [rad] for one cycle, and the switching loss can be reduced. The amplitude of fundamental wave of double sinusoidal modulated PWM inverter is 1.15 times higher than that of the sinusoidal PWM inverter, but the practical measured value by FFT analyzer is 1.13 times.

  • PDF

Harmonic Characteristic Analysis of a Modified Trapezoidal PWM Inverter (Modified Trapezoidal PWM 인버터 고조파 특성 해석)

  • 조우성;김인동;노의철;김만고;전성즙;조철제;문성득
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.256-259
    • /
    • 1999
  • A new PWM method for voltage source inverters is described. The switching instants determination of the proposed PWM scheme is simple. Therefore, hardware implementation with a microprocessor system is easy and high frequency operation of an inverter can be obtained. The maximum line-to-line output voltage of 3-phase inverter with the proposed scheme is larger than that of the SPWM inverter under a linear modulation region. Principle of the proposed PWM method is described and harmonic characteristic analysis is carried out.

  • PDF

COMMON-MODE VOLTAGE PULSE CANCELLATION METHOD BASED ON SPACE-VECTOR PWM IN CONVERTER-INVERTER SYSTEM

  • Lee, Hyeoun-Dong;Sul, Seung-Ki
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.171-175
    • /
    • 1998
  • This paper proposes the advanced PWM method that can reduce common-mode voltage in three-phase PWM converter-inverter system. By the proper distribution of the zero-voltage vector of inverter, it is possible to cancel out a common-mode voltage pulse in a sampling period. Since the proposed PWM method maintains the effective-voltage vector, it does not affect the control performance of converter-inverter system. Without any extra hardware, overall common-mode voltage can be decreased by one-third compared with conventional PWM scheme.

  • PDF

The control method of 3-level PWM inverter in special application using neural networks (신경회로망을 사용한 특정용도의 3-level PWM 인버터 제어방법)

  • 이현원;김남해;박귀태
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1261-1264
    • /
    • 1996
  • This paper presents the design of a neural network based PWM technique for a three level inverter of electric trains. A three-level inverter has several advantages compared with a two-level inverter in this application. In viewpoint of correcting unbalance of DC-link voltage, a novel method is developed and verified in computer simulation.

  • PDF

A multilevel PWM Inverter for Harmonics Reduction (고조파 저감을 위한 다중 레벨 PWM 인버터)

  • Kang, Feel-Soon;Park, Sung-Jun;Kim, Cheol-U
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.11
    • /
    • pp.645-651
    • /
    • 2002
  • In this paper, a multilevel PWM inverter employing a cascaded transformer is presented to reduce the harmonics of output voltage and load currents. The proposed PWM inverter consists of two full-bridge modules and their corresponding transformers. The secondarics of each transformer are series-connected. So continuous output voltage levels can be synthesized from the suitable selection of the turns ratio of trasformer. And it appears an integral ratio to input DC source. Because of the cascaded connection of transformers, output filter inductor is not necessary. The operational principles and analysis are explained, and it is compared with a conventional isolated H-bridge PWM inverter. The validity of proposed multilevel inverter is verified through simulated and experimental waveform and their FFT results.