• Title/Summary/Keyword: PVA fiber

Search Result 259, Processing Time 0.025 seconds

Polyvinyl-alcohol fiber-reinforced concrete with coarse aggregate in beam elements

  • Leonardo M. Massone;Jaime Reveco;Alejandro Arenas;Fabian Rojas
    • Advances in Computational Design
    • /
    • v.8 no.2
    • /
    • pp.113-131
    • /
    • 2023
  • The use of fibers has been commonly considered in engineered cementitious composites, but their behavior with coarse aggregate in concrete has not been studied significantly, which is needed to meet structural performance objectives for design, such as ductility. This research analyzes the behavior of fiber-reinforced concrete with coarse aggregate with 0.62%, 1.23%, and 2% PVA (Polyvinyl-alcohol) content, varying the maximum aggregate size. Tensile (direct and indirect) and compressive concrete tests were performed. The PVA fiber addition in coarse aggregate concrete increased the ductility in compression, especially for the fiber with a larger aspect ratio, with a minor impact on strength. In addition, the tensile tests showed that the PVA fiber increased the tensile strength of concrete with coarse aggregate and, more significantly, improved the ductility. A selected mixture was used to build short and slender reinforced concrete beams to assess the behavior of structural members. PVA fiber addition in short beams changed the failure mode from shear to flexure, increasing the deflection capacity. On the other hand, the slender beam tests revealed negligible impact with the use of PVA.

Strain Rate Effect on tensile properties of Hooked Steel Fiber and PVA Fiber hybrid reinforced cementitious composites (후크형 강섬유와 PVA섬유를 하이브리드 보강한 시멘트복합체의 인장특성에 미치는 변형속도의 영향)

  • Son, Min-Jae;Kim, Gyu-Yong;Lee, Sang-Kyu;Kim, Gyeong-Tae;Baek, Jae-Uk;Nam, Jeong-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.208-209
    • /
    • 2018
  • In this study, the tensile properties of hybrid fiber reinforced cementitious composites under the high strain rate was evaluated. Experimental results, the HSF1.5PVA0.5 shown the highest tensile strength because the PVA fiber suppressed the micro cracks in the matrix around the hooked steel fiber and improved the pull-out resistance of hooked steel fiber. Thus, DIF of strain capacity and fracture toughness of HSF1.5PVA were greatly improved. Also, the fracture toughness was greatly improved because the tensile stress was slowly decreased after the peak stress by improvement of the pull-out resistance performance of hooked steel fiber at strain rate 101/s.

  • PDF

The Strength and Flowing Properties of PVA Fiber Mortar using the Low-carbon Inorganic Composite according the Replacement Ratio of Fine Aggregate (잔골재 치환율별 저탄소 무기결합재를 사용한 PVA섬유 모르타르의 유동 및 강도특성)

  • Park, Jong-Pil;Moon, Ji-Hwon;Kim, Gyu-Yong;Lee, Sang-Soo;Song, Ha-Young
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.05a
    • /
    • pp.89-90
    • /
    • 2012
  • This study analyzed and compared the flowing and strength properties of mortar depending on the different fine aggregate replacement ratios and whether or not the mixing of PVA fiber was applied. blast furnace slag, red mud, and silica fume that are industrial by-products were used for the analysis. The findings showed that higher replacement level of fine aggregate increased air content while decreasing the table flow. In addition, in case of the compressive strength, Plain mortar and PVA fiber with the replacement ratios of 15% and 30%, respectively showed the greatest strength development.

  • PDF

A Study on the Fluidity Properties and Strength Properties of Non-sintered Hwangtoh mixed with PVA Fiber (PVA섬유를 혼입한 비소성 황토 콘크리트의 유동특성 및 강도특성에 관한 연구)

  • Lee, Sang-Soo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.3
    • /
    • pp.49-56
    • /
    • 2010
  • The purpose of this study is to examine the effect of variations in the mix rate of PVA fiber and the replacement ratio of non-sintering Hwangtoh on non-sintering Hwangtoh mortar and concrete mixed with PVA fiber. For water to binder ratio, mortar and concrete were both 50%, and PVA fiber mix rate was 0% and 0.3%. The replacement ratio of non-sintering Hwangtoh was 0, 25, 50 and 75(%) for mortar, and 0, 15, 30 and 50(%) for concrete. The properties of the mortar and concrete were compared and analyzed in 4 different levels, and the results can be summarized as follows. The replacement ratio of 30% of the non-sintering Hwangtoh, and the PVA fiber mix rate of 0.3% is determined to result in concrete of high quality, including strength and fluidity, and crack control by plastic shrinkage.

A Study on Fiber Reinforced Cement using PVA and Carbon Fiber (PVA와 탄소섬유를 이용한 섬유강화시멘트에 관한 연구)

  • 김민영;이준석;김종원;이동률
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2003.10b
    • /
    • pp.67-69
    • /
    • 2003
  • 콘크리트는 경제성과 압축강도, 내구성 및 강성 등의 우수한 물성을 가지고 있으나 인장, 휨 및 충격강도가 낮고 에너지 흡수능력이 작아 취성적이며 균열에 대한 저항성이 작은 단점을 가지고 있다. 이러한 단점을 개선하기 위해서 각종 섬유를 콘크리트에 분산시켜 만든 섬유보강시멘트(FRC : Fiber Reinforced Cement)의 개발 및 이용이 활발히 진행되고 있다. PVA 섬유는 우수한 선형성, 입체구조의 간략함과 규칙성, 고결정성 그리고 우수한 접착성을 가지며, 유기 고분자로는 유일하게 PH 13.5이상의 격렬한 알칼리 조건에서도 거의 손상되지 않는 우수한 내알칼리성을 가지고 있다. (중략)

  • PDF

Plastic Shrinkage and Durability Characteristics of Fiber Reinforced Polymer-Modified Mortars (섬유보강 폴리머 시멘트 모르타르의 초기수축균열 및 내구특성)

  • Won Jong Pil;Jang Pil Sung;Kim Myeong Kyun;Kong Tae Woong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.156-159
    • /
    • 2004
  • The intention of this study is to reduce the plastic shrinkage of the polymer modified cement mortar using the PVA fiber. The durability of PVA fiber reinforced polymer cement mortar was also evaluated. The test results of PVA fiber reinforced polymer modified cement mortar were compared with plain polymer modified cement mortar(non-fiber). In conclusion, PVA fiber reinforced polymer modified cement mortar showed an ability to reduce the total crack area and maximum crack width significantly. Also. fiber reinforced polymer modified cement mortar show improved durability performance.

  • PDF

Unconfined Compressive Strength of Fiber-reinforced Cemented Sands by Fiber Reinforcement Form (섬유의 보강 형태에 따른 섬유-시멘트 혼합토의 일축압축강도특성)

  • Park, Sung-Sik;Kim, Young-Su;Lee, Jong-Cheon
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.8
    • /
    • pp.159-169
    • /
    • 2007
  • The behavior of fiber-reinforced cemented sands (FRCS) was studied to improve a brittle failure mode observed in cemented sands. Nak-dong River sand was mixed with ordinary Portland cement and a Polyvinyl alcohol (PVA) fiber. A PVA fiber is widely used in concrete and cement reinforcement. It has a good adhesive property to cement and a specific gravity of 1.3. A PVA fiber has a diameter of 0.1 mm that is thicker than general PVA fiber for reinforced cement. Clean Nak-dong River sand, cement and fiber at optimum water content were compacted in 5 layers giving 55 blows per layer. They were cured for 7 days. Cemented sands with a cement/sand ratio of 4% were fiber-reinforced at different locations and tested for unconfined compression tests. The effect of fiber reinforcement form and distribution on strength was investigated. A specimen with evenly distributed fiber showed two times more strength than not-evenly reinforced specimen. The strength of fiber-reinforced cemented sands increases as fiber reinforcement ratio increases. A fully reinforced specimen was 1.5 times stronger than a specimen reinforced at only middle part. FRCS behavior was controlled not only by a dosage of fiber but also by fiber distribution methods or fiber types.

Phase Segmentation of PVA Fiber-Reinforced Cementitious Composites Using U-net Deep Learning Approach (U-net 딥러닝 기법을 활용한 PVA 섬유 보강 시멘트 복합체의 섬유 분리)

  • Jeewoo Suh;Tong-Seok Han
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.36 no.5
    • /
    • pp.323-330
    • /
    • 2023
  • The development of an analysis model that reflects the microstructure characteristics of polyvinyl alcohol (PVA) fiber-reinforced cementitious composites, which have a highly complex microstructure, enables synergy between efficient material design and real experiments. PVA fiber orientations are an important factor that influences the mechanical behavior of PVA fiber-reinforced cementitious composites. Owing to the difficulty in distinguishing the gray level value obtained from micro-CT images of PVA fibers from adjacent phases, fiber segmentation is time-consuming work. In this study, a micro-CT test with a voxel size of 0.65 ㎛3 was performed to investigate the three-dimensional distribution of fibers. To segment the fibers and generate training data, histogram, morphology, and gradient-based phase-segmentation methods were used. A U-net model was proposed to segment fibers from micro-CT images of PVA fiber-reinforced cementitious composites. Data augmentation was applied to increase the accuracy of the training, using a total of 1024 images as training data. The performance of the model was evaluated using accuracy, precision, recall, and F1 score. The trained model achieved a high fiber segmentation performance and efficiency, and the approach can be applied to other specimens as well.

Fire resistance of hybrid fiber reinforced SCC: Effect of use of polyvinyl-alcohol or polypropylene with single and binary steel fiber

  • Kazim Turk;Ceren Kina;Esma Balalan
    • Advances in concrete construction
    • /
    • v.16 no.1
    • /
    • pp.1-20
    • /
    • 2023
  • This study presents the experimental results performed to evaluate the effects of Polyvinyl-alcohol (PVA) and Polypropylene (PP) fibers on the fresh and residual mechanical properties of the hybrid fiber reinforced SCC before and after the exposure of 250℃, 500℃ and 750℃ temperatures. The compressive and splitting tensile strength, modulus of rupture (MOR), ultrasonic pulse velocity (UPV) as well as toughness and weight loss were investigated at different temperatures. PVA and PP fibers were added into SCC mixtures having only macro steel fiber and also having binary hybridization of both macro and micro steel fiber. The results showed that the use of micro steel fiber replaced by macro steel fiber improved the fresh and hardened properties compared to the use of only macro steel fiber. Moreover, it was emphasized that PVA or PP enhanced the residual flexural performance of SCC, generally, while it negatively influenced the workability, weight loss, UPV and the residual strengths with regards to the use of single steel fiber and binary steel fiber hybridization. Compared to the effect of synthetic fibers, PP had slightly more positive effect in the view of workability while PVA enhanced the residual mechanical properties more.

Mixing and Compressive Strength Characteristics of Steel Cord and PVA Hybrid Fiber Reinforced Cement-Based Composites (Steel Cord와 PVA 혼합섬유 보강 고인성 시멘트 복합체의 비빔 및 압축강도 특성)

  • Yun Hyun Do;Yang Il Seung;Han Byung Chan;Hiroshi Fukuyama;Cheon Esther;Moon Youn Joon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.28-31
    • /
    • 2004
  • This paper discusses the role of micro and macrofibers in the workability, compressive strength, and failure of cementitious composites. Workability(flow), compressive strength, splitting strength and fracture mechanism of hybrid fiber reinforced cement composites(HFRCC) have been investigated by means of Korean Standard (KS). The specific blend pursued in this investigation is a combination of polyvinyl alcohol(PVA) and steel cord. It was demonstrated that a hybrid combination of steel and PVA enhances fiber dispersion compared to only steel cord reinforced cement composites and that the brittle and wide cracking was much reduced in HFRCC as expected because in the matrix containing the PVA fiber around the steel cord, a multiple microcracking occurred and the steel cord could sufficiently work for bridging the cracked surface.

  • PDF