• Title/Summary/Keyword: PV model

Search Result 273, Processing Time 0.036 seconds

Simulation Analysis and Development of Matlab/Simulink Model for Stand-alone Operation of Emergency Diesel Synchronous Generator-based Hybrid Energy System (비상용 디젤동기발전시스템기반 독립운전 하이브리드에너지시스템 모델 설정 및 시뮬레이션 분석에 관한 연구)

  • Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.1
    • /
    • pp.70-79
    • /
    • 2015
  • In this paper, enhanced stand-alone operation and development of Matlab/Simulink model of emergency diesel based hybrid energy system is presented. Simulations based on the remote community or islands were performed for PV-diesel-battery hybrid system. Modeling of PV-diesel-battery integrated system is done to perform under the solar radiation and load conditions on Matlab/Simulink platform. The models of diesel generator unit, battery energy storage system, PV and frequency-power control are developed and simulation studies have been carried out under various conditions using Matlab/Simulink and SimPowerSystem. It is demonstrated that the proposed system can provide reliable and good quality power to the customers in diesel synchronous generator-based hybrid energy systems.

Study on the Simulation Model for applying PV Generation System to Micro-Grid based on Real Power System (실계통을 토대로한 마이크로그리드에 태양광 발전시스템을 적용하기 위한 시뮬레이션 모델에 관한 연구)

  • Lee, Kye-B.;Kim, Sung-Hyun;Son, Kwang M.;Jeon, In-Su
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.520-521
    • /
    • 2008
  • This paper deals with simulation model of the micro-grid system based on the real power system and applying PV generation system to micro-grid system. PSCAD/EMTDC simulation model is developed for use in studying the effect of the dynamics of PV generation to the micro-grid system. Simulation results show that the addition of the PV system improves the voltage profile of the area. Case studies also show that power quality at the load side is improved via voltage compensation at the load bus.

  • PDF

Performance Simulation Results for Photovoltaic Module Modeling (PV모듈 모델링에 의한 성능모의 결과비교)

  • So, Jung-Hun;Yu, Byung-Gyu;Hwang, Hye-Mi;Yu, Gwon-Jong;Choi, Ju-Yeop
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.11
    • /
    • pp.1988-1993
    • /
    • 2008
  • Photovoltaic (PV) modules operate over a large range of conditions but manufacturer's information is not sufficient to determine their overall performance. Designers need a reliable tool to predict energy production from a photovoltaic module under all conditions in order to make a sound decision. The modeling method of photovoltaic (PV) module are useful to perform detailed analysis of PV system performance for changing meteorological conditions, verify actual rated power of PV system sizing and determine the optimal design of PV system and components. This paper indicates a modeling approach of PV module performance in terms of meteorological conditions and identifies validity of PV modules modeling by comparing measured with simulated value.

Analysis of Module Mismatch Loss in Solar PV String and Feasibility Study for Improvement Method (태양광 PV 스트링에서의 모듈 부정합 손실의 분석 및 개선 기법 타당성 연구)

  • Ahn, Hee-Wook
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.1
    • /
    • pp.58-63
    • /
    • 2009
  • In this paper, the power loss due to PV module mismatch in PV string is analyzed and a mismatch compensation method is proposed to improve the efficiency of PV system. The analysis of mismatch loss using PV model simulation reveals that the mismatch module may decrease the total efficiency because the MPPT function of power conditioner make the PV system operate at the local maximum point. The mismatch loss can be severe if the maximum power point current of mismatch module is less than that of string. The proposed compensation method which is simply implemented with a buck type converter shows the possibility to remove the mismatch loss. The effectiveness of the analysis and compensation method is verified by a prototype experiment.

PV/FI Model in Sequential Investment Process under Certainty (확실성하의 순차적 투자과정에서의 PV/FI 투자대안 결정 모형)

  • Min Gye-Ryo
    • Journal of the military operations research society of Korea
    • /
    • v.9 no.1
    • /
    • pp.15-28
    • /
    • 1983
  • In sequential capital allocation processes, the information on the future availability (flexibility) of invested funds provides a decision maker with additional insight into the characteristics of alternatives. The investment decision with consideration of flexibility and profitability results in more wealth accumulation than the decision without considering flexibility does in sequential investment processes. To utilize the information on the flexibility under certainty, the PV/FI decision model is developed.

  • PDF

An Efficient and High-gain Inverter Based on The 3S Inverter Employs Model Predictive Control for PV Applications

  • Abdel-Rahim, Omar;Funato, Hirohito;Junnosuke, Haruna
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.4
    • /
    • pp.1484-1494
    • /
    • 2017
  • We present a two-stage inverter with high step-up conversion ratio engaging modified finite-set Model Predictive Control (MPC) for utility-integrated photovoltaic (PV) applications. The anticipated arrangement is fit for low power PV uses, the calculated efficiency at 150 W input power and 19 times boosting ratio was around 94%. The suggested high-gain dc-dc converter based on Cockcroft-Walton multiplier constitutes the first-stage of the offered structure, due to its high step-up ability. It can boost the input voltage up to 20 times. The 3S current-source inverter constitutes the second-stage. The 3S current-source inverter hires three semiconductor switches, in which one is functioning at high-frequency and the others are operating at fundamental-frequency. The high-switching pulses are varied in the procedure of unidirectional sine-wave to engender a current coordinated with the utility-voltage. The unidirectional current is shaped into alternating current by the synchronized push-pull configuration. The MPC process are intended to control the scheme and achieve the subsequent tasks, take out the Maximum Power (MP) from the PV, step-up the PV voltage, and introduces low current with low Total Harmonic Distortion (THD) and with unity power factor with the grid voltage.

Self Introduction Essay Classification Using Doc2Vec for Efficient Job Matching (Doc2Vec 모형에 기반한 자기소개서 분류 모형 구축 및 실험)

  • Kim, Young Soo;Moon, Hyun Sil;Kim, Jae Kyeong
    • Journal of Information Technology Services
    • /
    • v.19 no.1
    • /
    • pp.103-112
    • /
    • 2020
  • Job seekers are making various efforts to find a good company and companies attempt to recruit good people. Job search activities through self-introduction essay are nowadays one of the most active processes. Companies spend time and cost to reviewing all of the numerous self-introduction essays of job seekers. Job seekers are also worried about the possibility of acceptance of their self-introduction essays by companies. This research builds a classification model and conducted an experiments to classify self-introduction essays into pass or fail using deep learning and decision tree techniques. Real world data were classified using stratified sampling to alleviate the data imbalance problem between passed self-introduction essays and failed essays. Documents were embedded using Doc2Vec method developed from existing Word2Vec, and they were classified using logistic regression analysis. The decision tree model was chosen as a benchmark model, and K-fold cross-validation was conducted for the performance evaluation. As a result of several experiments, the area under curve (AUC) value of PV-DM results better than that of other models of Doc2Vec, i.e., PV-DBOW and Concatenate. Furthmore PV-DM classifies passed essays as well as failed essays, while PV_DBOW can not classify passed essays even though it classifies well failed essays. In addition, the classification performance of the logistic regression model embedded using the PV-DM model is better than the decision tree-based classification model. The implication of the experimental results is that company can reduce the cost of recruiting good d job seekers. In addition, our suggested model can help job candidates for pre-evaluating their self-introduction essays.

Modeling and Operation of Hybrid Energy System with Supercapacitor Bank and PV System (PV와 슈퍼캐패시터 하이브리드에너지시스템 모델 및 제어.운영기술)

  • Cho, Jea-Hoon;Hong, Won-Pyo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.291-295
    • /
    • 2009
  • Economic and environmental concerns over fossil fuels encourage the development of photovoltaic(PV) energy systems. Due to the intermittent nature of solar energy. energy storage is needed in a stand-alone PV system for the purpose of ensuring continuous power flow. Grid-connected PV system that supply power in a critical load demand require to curb power fluctuation. In this case. SCB is a effectiveness in controlling power variation due to intrinsic PV system. We propose the Matlab/Simulink dynamic model and power flow characteristics of a hybrid energy system with PV and SCB.

  • PDF

Mathematical Consideration on PV Cell Modeling (PV cell modeling의 수학적 고찰)

  • Park, Hyeonah;Kim, Hyosung
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.234-235
    • /
    • 2013
  • PV cell model은 PV simulator를 제작하거나 시뮬레이션 Software를 통하여 PV 발전시스템을 분석하기 위하여 필요하다. PV cell의 I-V 특성곡선은 PV cell의 특성을 결정짓는 중요한 요소이며, 전기적으로 다이오드정수($I_o$, $v_t$)와 광전류원($I_{ph}$) 그리고 직렬저항($R_s$) 및 션트저항($R_{sh}$)으로 모델링 가능하다. 광 전류원은 일사량에 비례하여 그 값을 추정할 수 있으나 나머지 변수인 다이오드정수($I_o$, $v_t$)와 직렬저항($R_s$) 및 션트저항($R_{sh}$)은 제조사 데이터시트에서 제공하는 3개의 대표적인 운전점인 개방회로 전압($V_{oc}$), 단락회로 전류($I_{sc}$), 그리고 최대출력에서의 전압/전류($V_{MPP}/I_{MPP}$)를 기초로 수학적으로 해를 구하여야만 한다. 본 논문에서는 저자가 제안하는 K-알고리즘의 수학적 도출 과정과 수치해석적 특성을 고찰한다.

  • PDF

Impedance Analysis and Surge Characteristics of PV Array

  • Lee, Ki-Ok;So, Jeong-Hoon;Yu, Gwon-Jong;Park, Ju-Yeop
    • Journal of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.259-264
    • /
    • 2003
  • Photovoltaic (PV) array, which is generally installed outside, has the possibility of being damaged by high voltage due to lightning. primarily because the electrical characteristics of PV array have not been fully identified by lightning yet, there is a very important issue whether PV array should be connected with a ground or not. In this paper, a basic model of PV array is provided considering the PV cell's barrier capacitance and ground capacitance for analysis of electrical characteristics by lightning.