• Title/Summary/Keyword: PV Curve

Search Result 82, Processing Time 0.033 seconds

A Study on Voltage Stability Assessment Using the Reactive Reserve Iindex (무효전력 예비력 지수를 이용한 전압안정도 평가 방안에 관한 연구)

  • Seo, Sang-Soo;Lee, Byong-Jun;Nam, Su-Chul;Shin, Jeong-Hoon;Kim, Tae-Kyun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.457-458
    • /
    • 2007
  • The reactive reserves of generators is close to voltage stability. This characteristic has led to the development of a few year monitoring the reactive reserves. In this paper, the reactive reserves have been calculated considering the generator capability curve. In addition, through dividing the systems using electric distance, the reactive reserves of each area has been calculated. Then, using the correlative relationship between reactive reserves and PV margins, the method for monitoring the voltage stability is proposed. The proposed method is tested on PSS/E test system and KEPCO system.

  • PDF

Research on fast cool-down of orifice pulse tube refrigerator by controlling orifice valve opening

  • Kim, Hyo-Bong;Park, Jong-Ho
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.4
    • /
    • pp.36-40
    • /
    • 2010
  • In this paper, a noble method for rapid cooldown of pulse tube refrigerator (PTR) was proposed and experimentally investigated. An orifice pulse tube refrigerator generates refrigeration effect by expansion PV work at the cold-end, and its amount is affected by the orifice valve opening. There exists the optimum valve opening for maximum cooling capacity and it varies as cold-end temperature. It is verified from simulation results using isothermal model that the optimum valve opening increases as the cold-end temperature increases. In the experiments, a single stage orifice pulse tube refrigerator is fabricated and tested. The fabricated PTR shows 97.5 K of no-load temperature and 10 W at 110 K of cooling capacity with the fixed orifice valve opening. From experiments, the initial cooldown curve with four cases of valve opening control scenario are obtained. And it is experimentally verified that the initial cooldown time can be reduced through the control of orifice valve opening.

Induction of Systemic Resistance against Bacterial Leaf Streak Disease and Growth Promotion in Rice Plant by Streptomyces shenzhenesis TKSC3 and Streptomyces sp. SS8

  • Hata, Erneeza Mohd;Yusof, Mohd Termizi;Zulperi, Dzarifah
    • The Plant Pathology Journal
    • /
    • v.37 no.2
    • /
    • pp.173-181
    • /
    • 2021
  • The genus Streptomyces demonstrates enormous promise in promoting plant growth and protecting plants against various pathogens. Single and consortium treatments of two selected Streptomyces strains (Streptomyces shenzhenensis TKSC3 and Streptomyces sp. SS8) were evaluated for their growth-promoting potential on rice, and biocontrol efficiency through induced systemic resistance (ISR) mediation against Xanthomonas oryzae pv. oryzicola (Xoc), the causal agent of rice bacterial leaf streak (BLS) disease. Seed bacterization by Streptomyces strains improved seed germination and vigor, relative to the untreated seed. Under greenhouse conditions, seed bacterization with consortium treatment TKSC3 + SS8 increased seed germination, root length, and dry weight by 20%, 23%, and 33%, respectively. Single and consortium Streptomyces treatments also successfully suppressed Xoc infection. The result was consistent with defense-related enzyme quantification wherein single and consortium Streptomyces treatments increased peroxidase (POX), polyphenol oxidase, phenylalanine ammonia-lyase, and β,1-3 glucanase (GLU) accumulation compared to untreated plant. Within all Streptomyces treatments, consortium treatment TKSC3 + SS8 showed the highest disease suppression efficiency (81.02%) and the lowest area under the disease progress curve value (95.79), making it the best to control BLS disease. Consortium treatment TKSC3 + SS8 induced the highest POX and GLU enzyme activities at 114.32 µmol/min/mg protein and 260.32 abs/min/mg protein, respectively, with both enzymes responsible for plant cell wall reinforcement and resistant interaction. Our results revealed that in addition to promoting plant growth, these Streptomyces strains also mediated ISR in rice plants, thereby, ensuring protection from BLS disease.

Improving the performance of PV system using the N-IC MPPT methods (N-IC MPPT방법을 이용한 태양광 발전시스템의 성능개선)

  • Seo, Tae-Young;Ko, Jae-Sub;Kang, Sung-Min;Kim, Yu-Tak;Chung, Dong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.958-959
    • /
    • 2015
  • This paper proposes adaptive incremental conductance(A-IC) algorithm for maximum power point tracking(MPPT) control of photovoltaic. Conventional Perturbation & Observation(PO) and IC MPPT control algorithm generally uses fixed step size. A small fixed step size will cause the tracking speed to decrease and tracking accuracy of the MPP will decrease due to large fixed step size. Therefore, this paper proposes N-IC MPPT algorithm that adjust automatically step size according to operating conditions. To improve tracking speed and accuracy, when operating point is far from maximum power point(MPP), step size uses maximum value and when operating point is near from MPP, step size uses variable step size that adjust according to slope of P-V curve. The validity of MPPT algorithm proposed in this paper prove through compare with conventional IC MPPT algorithm.

  • PDF

Comparison between bladder urine $O_{2}$ tension and mixed venous blood $O_{2}$ tension in human (방광뇨와 혼합정맥혈의 산소분압의 비교)

  • 이두연
    • Journal of Chest Surgery
    • /
    • v.19 no.4
    • /
    • pp.563-568
    • /
    • 1986
  • Tissue 02 tension is an important guide in detection of the general condition in critical patients. The tissue 0, is more difficult to measure with 0, sensor in skeletal muscle and subcutaneous tissues to present. But it is much easier to measure 0, tension in bladder urine with Censini catheter in Foley catheter than in tissue. We have measured 0, tension in bladder urine, main pulmonary artery and radial artery in 16 patients in chest surgical department of Yonsei University. College of Medicine from September 26 to December 22, 1981. Six patients were male and ten patients were female. Their ages ranged from 8 to 43 years. The correlation equation between the simultaneously measured PuO2 and PvO2 was found to be Ypvo2=4.04 + 0.88 Xpuo2 [r=0.88, p<0.0001] in regression curve with computer [HP/3,000, Program: SPSS] in the Yonsei University. Measurement of 0, tension in bladder urine and MPA will be rather simple, rapid and reproducible method than that of the 0, tension in tissues. But the speed of 0, consumption in urine is fast and so the 0, tensions in bladder urine were measured as soon as possible after they were collected. They were no complications or morbidity during measurement of 0, tension in these procedures except spontaneous removal of radial arterial cannulas in 2 patients.

  • PDF

Effect of Uranyl Nitrate-Induced Acute Renal Failure on the Pharmacokinetics of Sulfobromophthalein in Rats

  • Park, Gun-Hwa;Shim, Chang-Koo
    • Archives of Pharmacal Research
    • /
    • v.13 no.3
    • /
    • pp.233-239
    • /
    • 1990
  • The efect of acute renal failure (ARF) on the pharmacokinetics o sulfobromophthalein (BSP) was investigated in order to elucidate if renal failure modifies the hepatic metabolism of drugs. ARF was induced by intravenous (iv) injection of uranyl nitrate (UN) to rats (5 mg/kg) five days before the experiment. Area under the plasma concentration-time curve (AUC)of BSP after portal vein (pv) injection increased by 2-fold and total body clearance ($CL_1$) decreased one half (p <0.01) in UN-induced ARF (UN-ARF) rate compared to the control rats. But the plasma disappearance of BSP after iv injection did not differ significantly between control and UN-ARF rats. Since BSP is excreted via the liver, $CL_1$ represented the approximate hepatic clearance of BSP. Therefore, the decrease in $CL_1$ represented the approximate hepatic clearance of BSP. Therefore, the decrease in $CL_1$ represents a decrease in hepatic intrinsic clearance ($CL_{int}$) for BSP since plasma free fraction ($f_p$) of BSP was not affected by UN-ARF. The content of hepatic cytoplasmic Y-protein, which catalyzes BSP-glutathione conjugation and limits the trasfer of BSP from blood to bile, increased significantly (p < 0.01), however its binding activity (BA) for BSP was decreased significantly (p <0.01) by UN-ARF. The decrease in $CL_{int}$might have some correlation with the changed characteristics of hepatic Y-protein, specifically its decreased BA for BSP.

  • PDF

Development of a Coordinated Voltage Regulation Scheme in Distribution Networks with Multiple Distributed Generations (협조 제어를 이용한 분산전원 연계 배전계통의 전압조정 방식 개발)

  • Oh, Yun-Sik;Cho, Kyu-Jung;Kim, Min-Sung;Kim, Ji-Soo;Kim, Chul-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.9
    • /
    • pp.1309-1316
    • /
    • 2017
  • As penetration level of Distributed Generations (DGs) on weak distribution networks gets higher, voltage rise problem can often occur due to reverse power which is not expected in conventional distribution networks. It, however, cannot be effectively solved by using conventional voltage regulating devices such as On-Load Tap Changers (OLTCs), Step Voltage Regulators (SVRs) because those do not consider the presence of DGs when determining relevant setting parameter for voltage regulation. This paper presents a scheme for voltage regulation using coordinated control between OLTC and DGs which can actively participate in the regulation. The scheme decides which device should be operated first based on the characteristics of regulating devices, in order to prevent unnecessary operation of output changes of DG and excessive tap changing operation of OLTC. Computer simulations considering daily irradiation of PV and load curve are performed by using MATLAB Simulink and performance comparison between the presented scheme and conventional ones is also made. It can be concluded from simulation results that the scheme presented is very effective to regulate voltages in distribution networks with multiple DGs.

Battery Discharge System Configuration using Photovoltaic Simulator and PCS (태양광 시뮬레이터와 PCS를 이용한 배터리 방전시스템 구성)

  • Jeong, Da-Woom;Park, Sung-Min;Park, Seong-Mi;Park, Sung-Jun;Moon, Seung-Pil
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.3
    • /
    • pp.491-498
    • /
    • 2020
  • Recently, In the production line of batteries, charge and discharge tests are essential to verify battery characteristics. In this case, the battery charging uses a unidirectional AC/DC converter capable of output voltage and current control, and the discharge uses a resistive load. Since this method consumes energy during discharge, it must be replaced with a bi-directional AC/DC converter system capable of charging and discharging. Although it is difficult to replace the connected inverter part of the bi-directional AC/DC converter system due to the high cost, the spread of the solar-connected inverter rapidly increases as the current solar supply business is activated, and thereby the solar-connected type Inverter prices are plunging. If it can be used as a power converter for battery discharge without program modification of the solar-powered inverter, it will have competition. In this paper, propose a new battery discharge system using a combination of a photovoltaic DC/DC simulator and photovoltaic PCS using a battery to be used as a power converter for battery discharge without program modification of a low-cost photovoltaic inverter. In addition, propose an optimal solar characteristic curve for the stable operation of PCS. The validity of the proposed system was verified using a 500[W] class solar DC/DC simulator and a solar PCS prototype.

Dual-Algorithm Maximum Power Point Tracking Control Method for Photovoltaic Systems based on Grey Wolf Optimization and Golden-Section Optimization

  • Shi, Ji-Ying;Zhang, Deng-Yu;Ling, Le-Tao;Xue, Fei;Li, Ya-Jing;Qin, Zi-Jian;Yang, Ting
    • Journal of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.841-852
    • /
    • 2018
  • This paper presents a dual-algorithm search method (GWO-GSO) combining grey wolf optimization (GWO) and golden-section optimization (GSO) to realize maximum power point tracking (MPPT) for photovoltaic (PV) systems. First, a modified grey wolf optimization (MGWO) is activated for the global search. In conventional GWO, wolf leaders possess the same impact on decision-making. In this paper, the decision weights of wolf leaders are automatically adjusted with hunting progression, which is conducive to accelerating hunting. At the later stage, the algorithm is switched to GSO for the local search, which play a critical role in avoiding unnecessary search and reducing the tracking time. Additionally, a novel restart judgment based on the quasi-slope of the power-voltage curve is introduced to enhance the reliability of MPPT systems. Simulation and experiment results demonstrate that the proposed algorithm can track the global maximum power point (MPP) swiftly and reliably with higher accuracy under various conditions.

Analysis and comparison of initial performance degradation for single crystalline silicon solar cell under open and short circuit (단결정 태양전지의 단락 및 개방 시 노광에 의한 초기 출력저하 비교 분석)

  • Jung, Tae-Hee;Kim, Tae-Bum;Shin, Jun-Oh;Yoon, Na-Ri;Woo, Sung-Cheol;Kang, Gi-Hwan;Ahn, Hyung-Keun;Han, Deuk-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.6
    • /
    • pp.16-21
    • /
    • 2010
  • It is well-known that Boron-doped Cz Si solar cells suffer light-induced degradation due to boron-oxygen defect which is responsible of a reduction in lifetime and hence efficiency. In this paper, we assume that PV solar cell has been connected with variable load to account the real operating condition and it shows different light-induced degradation of Si solar cell. To evaluate the effect of light-induced degradation for solar cell with various load, Single crystalline solar cells are connected with open and short circuits during light exposure. Isc-Voc curve evaluate light induced degradation of solar cells and the reason is explained as a change for serial resistance. From the results, Electrical characteristics of solar cells show better performance under short circuit conditions, after light exposure.