• 제목/요약/키워드: PV/T system

검색결과 84건 처리시간 0.03초

일사량 급변에 대한 P&O 알고리즘의 개선 (Improved P&O algorithm for rapidly changing insolation)

  • 강안종;김태우;김학성
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.117-120
    • /
    • 2004
  • As the maximum power operating point (MPOP) of photovoltaic (PV) power generation systems changes with varying atmospheric conditions such as solar radiation and temperature, an important consideration in the design of efficient PV system is to track the MPOP correctly. Although the efficiency of these Maximum Power Point Tracking algorithms is usually high, it drops noticeably in case of rapidly changing atmospheric conditions. This paper describes common MPPT control algorithm: Constant Voltage Control, Perturbation and Observation(P&O), Incremental Conductance (IncCnd) and proposes a new MPPT algorithm based on P&O algorithm. The conception and control principles of the proposed MPPT method are explained in detail and its validity of the proposed method is verified through several simulated results. As it doesn't use digital signal processor, this MPPT method has the merits of both a cost efficiency and a simple control circuit design. Therefore, it is considered that the proposed MPPT method is proper to low power, low cost PV applications.

  • PDF

III-V 화합물 반도체를 이용한 고효율 집광형 태양광 발전시스템 설계 및 성능분석 (Designed and Performance Analysis of High Efficiency Concentrated Photovoltaic System using III-V Compound Semiconductor)

  • 고재홍
    • 조명전기설비학회논문지
    • /
    • 제26권9호
    • /
    • pp.33-39
    • /
    • 2012
  • For photovoltaic power generation need certainly decreasing module's price and increasing promote efficiency technology. Almost of solar panel is on the decrease energy efficiency since 2,000. like silicone(Si) solar panel, thin film solar panel and etc. Silicone(Si) solar panel was best efficiency in 1999. It's 24%. But after that time, It didn't pass limit of energy efficiency. That's why, nowadays being issued that using III-V compound semiconductor to high efficiency of concentrating photovoltaic system for making an alternative proposal. In Korea, making researches in allied technology with III-V compound semiconductor solar panel, condenser technology, and solar tracker. but feasibility study for concentrating photovoltaic power generation hasn't progressed yet. This thesis made a plan about CPV(Concentrating Photovoltaic)system and CPV has a higher energy efficiency than PV(Photovoltaic)system in fine climate conditions from comparing CPV with using silicone(Si) solar panel to PV's efficiency test result.

오프셋 전압을 이용한 계통 연계형 3상 3레벨 T-type 태양광 PCS의 중성점 전압 불평형 보상 (Compensation of Unbalanced Neutral Voltage for Grid-Connected 3-Phase 3-Level T-type Photovoltaic PCS Using Offset Voltage)

  • 박관남;최익;최주엽;이영권
    • 한국태양에너지학회 논문집
    • /
    • 제37권6호
    • /
    • pp.1-12
    • /
    • 2017
  • The DC link of Grid-Connected 3-Phase 3-Level T-type Photovoltaic PCS (PV-PCS) consists of two series connected capacitors for using their neutral voltage. The mismatch between two capacitor characteristics and transient states happened in load change cause the imbalance of neutral voltage. As a result, PV-PCS performance is degraded and the system becomes unstable. In this paper, a mathematical model for analyzing the imbalance of neutral voltage is derived and a compensation method using offset voltage is proposed, where offset voltage adjusts the applying time of P-type and N-type small vectors. The validity of the proposed methods is verified by simulation and experiment.

3kW급 일체형 계통연계 태양광발전 시스템 실증연구 (Demonstration Analysis of 3kW Integrated PV System)

  • 조애옥;김지훈;나종덕;최문한;박수강
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.727-729
    • /
    • 2005
  • Solar cell converts sunlight into the electricity that one of the most versatile forms of energy. It has been developed and applied on residental electric power system by urbanized countries as a alternative energy source to overcome energy problem after oil shock. This paper summarizes the results of these efforts by offering a snapshot of the configuration of photovoltaic in residential applications. The status of PV system components and inter -connection and safety equipment will be summarized. Hence this paper discusses only points that might be useful for application.

  • PDF

QZSI를 사용한 태양광 발전시스템의 전력제어 (Power control of Photovoltaic Generator System Using Quasi Z-Source Inverter)

  • 김지용;전태원;이홍희;김흥근;노의철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 추계학술대회
    • /
    • pp.246-247
    • /
    • 2010
  • This paper proposed a method for controlling the active power of a single-phase grid-connected photovoltaic(PV) system by the quasi-Z-source inverter (QZSI). The MPPT of PV array is achieved by adjusting a shoot-through time of QZSI. The PI+R controller is used for reducing the steady-state error of the grid current. The simulation studies are carried out to verify the performances of proposed system.

  • PDF

실험을 통한 BIPV/T 시스템 성능분석-2.시스템 열성능 (Performance Analysis of the BIPV/T system by the performance Test- Part2. Thermal Performance)

  • 조혜진;이현주
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.255-259
    • /
    • 2012
  • BIPV/T (Building Intergrated PhotoVoltaic/Thermal) is combined system produces electricity and thermal energy. The heat from PV modules should be removed for better electrical performance, and can be converted into useful thermal energy. The test system is installed to top floor of the experimental house in the KEPCO Research Institute. The experimental performance is executed from 13th February to 13th March, 2012. The expected system's thermal performance is 1.9kWh under the horizontal solar radiation is $600W/m^2$ and the air flow in the system is $20CMH/m^2$.

  • PDF

MPPT 및 CCVC 알고리즘을 적용한 에너지 절약형 OF-LED 광고조명시스템 (Energy Saving Type OF-LED Illuminated Display Board System with MPPT and CCVC Algorithms)

  • 이성룡;전칠환;이수원;이은철
    • 조명전기설비학회논문지
    • /
    • 제19권2호
    • /
    • pp.1-6
    • /
    • 2005
  • 본 연구에서는 광고 조명으로 인한 에너지 소비를 극소화하기 위하여 OF-LED(Optical-Fiber LED)를 이용한 에너지 절약형 광고 조명 시스템에 대하여 연구하였다. 제안한 OF-LED광고 조명 시스템은 에너지 소비가 획기적으로 저감되고 시스템의 소형화가 가능하며, 부조일이 높은 장마철을 제외하고는 태양광 발전만으로 운영하는 큰 장점을 가진다. 태양전지의 출력 특성에 의한 배터리의 최단$\cdot$최적 충전을 위해 정전류$\cdot$정전압 제어법(CCVC)과, IncCond알고리즘을 병행하여 적용하였다 그리고 원칩 마이크로프로세서로 디스플레이 제어와 충 방전제어를 동시에 수행하도록 하였다. 이를 실험을 통하여 제시된 시스템의 유용성을 입증하였다.

태양광 발전 시스템을 위한 원격 통합 모니터링 시스템의 구축 및 운영분석

  • 홍성민;이용호;심헌
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 제17회 워크샵 및 추계학술대회
    • /
    • pp.182-190
    • /
    • 2005
  • This paper proposes central monitoring system(PVCMS) based on a TCP/IP network for effective integrating management about photovoltaic systems. We don't gain confidence the result of production simulation, because the output of PV system have many various environmental change factor. So if we can obtain real operated data about each sites and system types to use PVCMS, we can define the environment change factor to compare with simulation data. And this paper try to access about total management and data analysis methods of renewable energy through results analysis to synthesize of the operation.

  • PDF

Compensation for Photovoltaic Generation Fluctuation by Use of Pump System with Consideration for Water Demand

  • Imanaka, Masaki;Sasamoto, Hideki;Baba, Jumpei;Higa, Naoto;Shimabuku, Masanori;Kamizato, Ryota
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1304-1310
    • /
    • 2015
  • In remote islands, due to expense of existing generation systems, installation of photovoltaic cells (PVs) and wind turbines has a chance of reducing generation costs. However, in island power systems, even short-term power fluctuations change the frequency of grids because of their small inertia constant. In order to compensate power fluctuations, the authors proposed the power consumption control of pumps which send water to tanks. The power control doesn’t affect water users’ convenience as long as tanks hold water. Based on experimental characteristics of a pump system, this paper shows methods to determine reference power consumption of the system with compensation for short-term PV fluctuations while satisfying water demand. One method uses a PI controller and the other method calculates reference power consumption from water flow reference. Simulations with a PV and a pump system are carried out to find optimum parameters and to compare the methods. Results show that both PI control method and water flow calculation method are useful for satisfying the water demand constraint. The water demand constraint has a little impact to suppression of the short-term power fluctuation in this condition.

Recombinant Expression and Purification of Functional XorII, a Restriction Endonuclease from Xanthomonas oryzae pv. oryzae

  • Hwang, Dong-Kyu;Cho, Jae-Yong;Chae, Young-Kee
    • Journal of Microbiology
    • /
    • 제45권2호
    • /
    • pp.175-178
    • /
    • 2007
  • An endonuclease from Xanthomonas oryzae pathovar oryzae KACC 10331, XorII, was recombinantly produced in Escherichia coli using a T7 system. XorII was purified using a combination of ion exchange and immobilized metal affinity chromatography (IMAC). An optimized washing protocol was carried out on an IMAC in order to obtain a high purity product. The final amount of purified XorII was approximately 2.5 mg/L of LB medium. The purified recombinant XorII was functional and showed the same cleavage pattern as PvuI. The enzyme activity tested the highest at $25^{\circ}C$ in 50 mM NaCl, 10 mM Tris-HCl, 10 mM $MgCl_{2}$, and 1 mM dithiothreitol at a pH of 7.9.