• Title/Summary/Keyword: PV(photovoltaic) generation system

Search Result 385, Processing Time 0.03 seconds

Development of a 50kW Photovoltaic Power Generation System for Gird Connection(I) (50 kW급 계통연계형 태양광 발전시스템 개발(I))

  • Ahn, K.S.;Lim, H.C.;Hwang, I.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.31-33
    • /
    • 1999
  • In this paper, a operating characteristics of the 50 kW grid-connected Photovoltaic(PV) Power system which is by means of initial PV datum analyzing is reported. The development of a 50 kW class photovoltaic power generation system including a DC/AC inverter is suggested to investigate the system performance for grid connection. The results of the demonstration test of a 50 kW class grid-connected PV system show that the system utilization rate is 15.6% and the inverter efficiency is 94% at 80% load.

  • PDF

A Study on Working Characteristic of 50kW single crystal Photovoltaic System (50kW 단결정 태양광 발전시스템 운전특성연구)

  • An, Sang-Hyeon;Kim, Byung-Hyun;Park, Ji-Hong;Ahn, Hyung-Keun;Han, Deuk-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.194-195
    • /
    • 2007
  • This paper presents the experimental operation of invertactive 50kW photovoltaic system for monitoring periods. Form these performance monitoring results, the PV system performance has been evaluated and analyzed for component perspective. It has produced a regression equation. Using the equation, it is possible to estimate the annual electricity generation. The result of this study will be used to determine the appropriate capacity of PV system in different systems.

  • PDF

Photovoltaic Micro Converter Operated in Boundary Conduction Mode Interfaced with DC Distribution System

  • Seo, Gab-Su;Shin, Jong-Won;Cho, Bo-Hyung;Lee, Kyu-Chan
    • Proceedings of the KIPE Conference
    • /
    • 2011.11a
    • /
    • pp.44-45
    • /
    • 2011
  • Research on photovoltaic (PV) generation is taking a lot of attention due to its infinity and environment-friendliness with decrease of price per PV cell. While central inverters connect group of PV modules to utility grid in which maximum power point tracking (MPPT) for each module is difficult, micro inverter is attached on each module so that MPPT for individual modules can be easily achieved. Moreover, energy generation and consumption efficiency can be much improved by employing direct current (DC) distribution system. In this paper, a digitally controlled PV micro converter interfacing PV to DC distribution system is proposed. Boundary conduction mode (BCM) is utilized to achieve zero voltage switching (ZVS) of active switch and eliminate reverse recovery problem of passive switch. A 120W prototype boost PV micro converter is implemented to verify the feasibility and experimental results show higher than 98% efficiency at peak power and 97.29% of European efficiency.

  • PDF

A study of on the Efficiency Analysis for 3kW Utility interactive PV System (3kW 태양광발전시스템의 효율분석에 관한 연구)

  • Park, J.M.;Lim, H.W.;Choi, Y.O.;Lee, S.G.;Cho, G.B.;Baek, H.N
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.61-63
    • /
    • 2005
  • Utility interactive photovoltaic systems is one of the most premising applications of photovoltaic systems. These systems are employed in applications where utility service is already available. In this case, there is no need for battery storage because utility power may be used to supplement photovoltaic systems when the load exceeds available PV generation. The load receives electricity from both the photovoltaic array and the utility inter-tied. In this paper, Principle and operating characteristic of Utility Interconnected Photovoltaic System is presented. For the purpose of optimal utility Inter-tied photovoltaic system design and installation. It is that demonstrate throughout the installed 3 PV system respectively, 3kW utility interconnected residential system.

  • PDF

3W PV Generation System Development with Solar Tracker (3kW급 추적식 태양광발전 시스템 개발)

  • Kang S.Y.;Park G.N.;Park S.L.;Kim K.H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.687-691
    • /
    • 2003
  • In photovoltaic generation, PV module is used to generate the electricity, and this system has been in limelight as nonpolluting alternative energy source. But, as energy density is low and PV module cost is high, there is a disadvantage that initial investment cost go up. In this study, we studied the method of allowing a tracker, adequate to photovoltaic generation, for Increasing the generating. We determined the proper error angle in order to decrease the repeating number of tracking without a reduction of the generating by using our developed simulator. And, we presented the photovoltaic approach tracking control and achieved its experiment. Through the result of experiment, it is expected that the fault rate and the consumption of electric power in a tracker get reduced and its cost become cut down.

  • PDF

Novel Concept of Shunt Active Filter Function Added in PV Generation System (엑티브필터 기능을 추가한 새로운 태양광 발전시스템의 제안)

  • Kim, Bong-Tae;Park, Min-Won;Seong, Ki-Chul;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.296-300
    • /
    • 2001
  • Novel concept of shunt active filter (AF) function added in Photovoltaic (PV) generation system is described in this paper. So far, for the PV generation system has been treated as one of harmonic sources to the power distribution systems, not only a PV system combined with AF but also AF systems using PV module as their power source have never been discussed. The basic structure and control strategy of the PV-AF system are, for the first time, introduced in this work. In order to stabilize the output current of voltage source inverter (VSI), the reference voltage MPPT control is applied. Simulation analysis shows that it is possible to combine AF function to the three-phase grid-connected PV generation system without any physical difficulties, and the performance of the proposed PV-AF system is acceptable and stable as well.

  • PDF

An Economic Analysis and Consideration on the Application of Photovoltaic System for Bridge Nightscape Energy Savings at Han River in Seoul (서울시 한강교량의 태양광발전시스템 적용 시 경관조명 에너지 절약에 관한 경제성 분석 및 고찰)

  • Park, Yoon-Min;Hong, Seong-Kwan;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.1
    • /
    • pp.42-49
    • /
    • 2011
  • PV(Photovoltaic) system is environmentally friendly power system using solar energy in renewable energy. PV system compared to other renewable energy power generation systems is relatively easy to install, so the dissemination is increasing worldwide. Especially, BIPV(Building Integrated Photovoltaic) is a system that PV modules are installed on the building and use renewable energy. But this system is difficult to apply due to the shadow of adjacent buildings and limited installation. In this study, payback period is calculated by Retscreen 2010, that is an economic assessment software of renewable energy, on applied to the bridge of PV system. As results, this study aims at actively considering the application.

Internet Monitoring of Photovoltaic Generation System (태양광발전 시스템의 인터넷 모니터링)

  • Yang Si-Chang;Moon Chae-Joo;Chang Young-Hak;Soh Soon-Yeol;Kim Eui-Sun
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.529-531
    • /
    • 2006
  • The Photovoltaic(PV) generation system is a promising source of energy for the future. Since the need for renewable energy has been increased, the research of PV generation system has also been progressed. The main subject of this paper is about making the more useful real-time monitoring program to get and save the data from photovoltaic generation system of 30kW grid-connected. Therefore, it uses LabView for this real-time monitoring program.

  • PDF

Internet Monitoring of Photovoltaic Generation System (태양광발전 시스템의 인터넷 모니터링)

  • Moon, Chae-Joo;Yang, Si-Chang;Lim, Jung-Min;Chang, Young-Hak;Soh, Soon-Yeol;Kim, Eui-Sun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1173-1174
    • /
    • 2006
  • The Photovoltaic(PV) generation system is a promising source of energy for the future. Since the need for renewable energy has been increased, the research of PV generation system has also been progressed. The main subject of this paper is about making the more useful real-time monitoring program to get and save the data from photovoltaic generation system of 30kW grid-connected. Therefore, it uses LabView for this real-time monitoring program.

  • PDF

Economic Analysis on VLS-PV System from Sunbelt Region (Sunbelt 지역의 태양광발전 경제성분석)

  • Choi, Bong-Ha;Park, Soo-Uk;Lee, Deok-Ki;Kim, Seok-Ki;Song, Jin-Soo
    • New & Renewable Energy
    • /
    • v.2 no.4 s.8
    • /
    • pp.86-92
    • /
    • 2006
  • This paper analyses the economics of 50kW PV system installed in Tibet and using domestic technology. We show that this system can be expanded to very large-scale photovoltaic power generation [VLS-PV] system successfully. Based on this result, we conduct the economic analysis of 100MW VLS-PV system designed assuming that it will be installed from 2008 to 2017 in Tibet. In this analysis, future price of PV module and system are estimated based on the methodology of experience curve. In 50kW PV system, the generation cost is calculated at 567.2 won/kWh and this is lower than the one of domestic PV system. In future 100MW VLS-PV system. the generation cost is calculated at 305.4 won/kWh by declining system price. If the lifetime and efficiency of the system goes up, due to future technological improvements, the generation cost can be lowered. Moreover, under the environmental and political effect, VLS-PV system can be as competitive as the conventional energy within 20 years.

  • PDF