• Title/Summary/Keyword: PUSH Technology

Search Result 437, Processing Time 0.023 seconds

Push-out tests on demountable high-strength friction-grip bolt shear connectors in steel-precast UHPC composite beams for accelerated bridge construction

  • Haibo, Jiang;Haozhen, Fang;Jinpeng, Wu;Zhuangcheng, Fang;Shu, Fang;Gongfa, Chen
    • Steel and Composite Structures
    • /
    • v.45 no.6
    • /
    • pp.797-818
    • /
    • 2022
  • Steel-precast ultra-high-performance concrete (UHPC) composite beams with demountable high-strength friction-grip bolt (HSFGB) shear connectors can be used for accelerated bridge construction (ABC) and achieve excellent structural performance, which is expected to be dismantled and recycled at the end of the service life. However, no investigation focuses on the demountability and reusability of such composite beams, as well as the installation difficulties during construction. To address this issue, this study conducted twelve push-out tests to investigate the effects of assembly condition, bolt grade, bolt-hole clearance, infilling grout and pretension on the crack pattern, failure mode, load-slip/uplift relationship, and the structural performance in terms of ultimate shear strength, friction resistance, shear stiffness and slip capacity. The experimental results demonstrated that the presented composite beams exhibited favorable demountability and reusability, in which no significant reduction in strength (less than 3%) and stiffness (less than 5%), but a slight improvement in ductility was observed for the reassembled specimens. Employing oversized preformed holes could ease the fabrication and installation process, yet led to a considerable degradation in both strength and stiffness. With filling the oversized holes with grout, an effective enhancement of the strength and stiffness can be achieved, while causing a difficulty in the demounting of shear connectors. On the basis of the experimental results, more accurate formulations, which considered the effect of bolt-hole clearance, were proposed to predict the shear strength as well as the load-slip relationship of HSFGBs in steel-precast UHPC composite beams.

Evaluation of Shear Strength of Perfobond Rib in Ultra High Performance Concrete (초고성능 콘크리트에 대한 Perfobond Rib 전단연결재 거동 평가)

  • Kang, Jae-Yoon;Jung, Woo-Tai
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.7
    • /
    • pp.5015-5020
    • /
    • 2015
  • Push-out test is performed on perfobond shear connectors applying ultra high performance concretes with compressive strength higher than 80 MPa to evaluate their shear resistance. The test variables are chosen to be the diameter and number of dowel holes and, the change in the shear strength of the perfobond rib connector is examined with respect to the strength of two types of UHPC: steel fiber-reinforced concrete with compressive strength of 180 MPa and concrete without steel fiber with compressive strength of 80 MPa. The test results reveal that higher concrete strength and larger number of holes increased the shear strength, and that higher increase rate in the shear strength was achieved by the dowel action.

Analysis and Implementation of a Half Bridge Class-DE Rectifier for Front-End ZVS Push-Pull Resonant Converters

  • Ekkaravarodome, Chainarin;Jirasereeamornkul, Kamon
    • Journal of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.626-635
    • /
    • 2013
  • An analysis of the junction capacitance in resonant rectifiers which has a significant impact on the operating point of resonance circuits is studied in this paper, where the junction capacitance of the rectifier diode is to decrease the resonant current and output voltage in the circuit when compared with that in an ideal rectifier diode. This can be represented by a simplified series resonant equivalent circuit and a voltage transfer function versus the normalized operating frequency at varied values of the resonant capacitor. A low voltage to high voltage push-pull DC/DC resonant converter was used as a design example. The design procedure is based on the principle of the half bridge class-DE resonant rectifier, which ensures more accurate results. The proposed scheme provides a more systematic and feasible solution than the conventional resonant push-pull DC/DC converter analysis methodology. To increase circuit efficiency, the main switches and the rectifier diodes can be operated under the zero-voltage and zero-current switching conditions, respectively. In order to achieve this objective, the parameters of the DC/DC converter need to be designed properly. The details of the analysis and design of this DC/DC converter's components are described. A prototype was constructed with a 62-88 kHz variable switching frequency, a 12 $V_{DC}$ input voltage, a 380 $V_{DC}$ output voltage, and a rated output power of 150 W. The validity of this approach was confirmed by simulation and experimental results.

Experimental and numerical studies on the shear connectors in steel-concrete composite beams at fire and post fire exposures

  • Mirza, Olivia;Shil, Sukanta Kumer;Rashed, M.G.;Wilkins, Kathryn
    • Steel and Composite Structures
    • /
    • v.39 no.5
    • /
    • pp.529-542
    • /
    • 2021
  • Shear connectors are required to build composite (concrete and steel) beams. They are placed at the interface of concrete and steel to transfer shear and normal forces between two structural components. Such composite beams are sensitive to provide structural integrity when exposed to fire as they loss strength, stiffness, and ductility at elevated temperature. The present study is designed to investigate the shear resistance and the failure modes of the headed stud shear connectors at fire exposure and post-fire exposure. The study includes ordinary concrete and concrete with carbon nanotubes (CNTs) to build composite (concrete-steel) beams with structural steel. Experimental push tests were conducted on composite beams at ambient and elevated temperatures, such as 200, 400 & 600℃. Moreover, push tests were performed on the composite beams after being exposed to 200, 400 & 600℃. Push test results illustrated the reduction of ultimate shear capacity and stiffness of headed stud shear connectors as the temperature increased. Although similar values of ultimate shear were obtained for the headed stud connectors in both ordinary and CNT concrete, the CNT modified concrete reduced the concrete spalling and cracking compared to ordinary concrete and was observed to be effective at temperatures greater than 400℃. All specimens showed a lower shear resistance at fire exposures compared to the corresponding post-fire exposures. Moreover, numerical simulation by Finite Element (FE) analyses were carried out at ambient temperature and at fire conditions. The FE analysis results show a good agreement with the experimental results. In the experimental studies, failure of all specimens occurred due to shear failure of headed stud, which was later validated by FE analyses using ABAQUS.

An Empirical Study on the Factors Influencing the Adoption of Enterprise Architecture (아키텍처 노력 도입 수준의 영향 요인에 관한 실증적 연구)

  • Hong, Yong-Duck;Kim, Sung-Kun
    • Journal of Information Technology Applications and Management
    • /
    • v.14 no.1
    • /
    • pp.37-55
    • /
    • 2007
  • Enterprise Architecture (EA) is one of controversial subjects theses days. Some organizations, public or private, are very impetuous in adopting it and some are quite Indifferent to it. What makes this difference come about? This is our research question. One previous research has studied on this issue under the theory of diffusion of innovation. Instead, we here attempt to investigate, in the context of technology transfer theory, the influencing factors on the adoption of EA. We are especially interested In whether korea local organizations are more Influenced by 'need pull' factors than 'institutional push' factors or vice versa.

  • PDF

A 120 GHz Voltage Controlled Oscillator Integrated with 1/128 Frequency Divider Chain in 65 nm CMOS Technology

  • Kim, Namhyung;Yun, Jongwon;Rieh, Jae-Sung
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.1
    • /
    • pp.131-137
    • /
    • 2014
  • A 120 GHz voltage controlled oscillator (VCO) with a divider chain including an injection locked frequency divider (ILFD) and six static frequency dividers is demonstrated using 65-nm CMOS technology. The VCO is designed based on the LC cross-coupled push-push structure and operates around 120 GHz. The 60 GHz ILFD at the first stage of the frequency divider chain is based on a similar topology as the core of the VCO to ensure the frequency alignment between the two circuit blocks. The static divider chain is composed of D-flip flops, providing a 64 division ratio. The entire circuit consumes a DC power of 68.5 mW with the chip size of $1385{\times}835{\mu}m^2$.

Push-pull Strategy for Control of Sweet-potato Whitefly, Bemisia tabaci (Hemiptera: Aleyrodidae) in a Tomato Greenhouse (Push-pull 전략을 이용한 시설 토마토 담배가루이 방제효과)

  • Lee, Young Su;Lee, Hee A;Lee, Hyun Ju;Choi, Jong Yoon;Lee, Sang-Woo;Hong, Soon Sung;Jang, Myoung Jun
    • Korean journal of applied entomology
    • /
    • v.58 no.3
    • /
    • pp.209-218
    • /
    • 2019
  • This study was conducted to develop a technology for environmentally friendly control of sweet-potato whitefly, Bemisia tabaci, by controlling their behavior using a push-pull strategy in a tomato greenhouse. B. tabaci was attracted the most by yellow color, light source of 520 nm, whereas it avoided the complex light treatment of 450 + 660 nm. The two natural enemies of B. tabaci, Cyrtopeltis tenuis and Orius laevigatus, were attracted the most by 520 nm light source. B. tabaci was repelled by the volatile organic compounds ocimene and carvacrol and was the most attracted by methyl isonicotinate. When buckwheat was added into the tomato greenhouse, the density of C. tenuis was maintained at about 16 times higher than when untreated for 15 days. As a result of the combined treatment of push-pull strategy, the density per trap of B. tabaci was three times lower than when no treatment was applied, and the control of this pest increased with time and reached up to 68.7%.

Analysis of Forwarding Schemes for Push-based Information Service in Connected Vehicles over NDN (커넥티드 차량 엔디엔 네트워크 안에 푸쉬 기반 정보 서비스를 위한 전달 기법 분석)

  • Lim, Huhnkuk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.2
    • /
    • pp.280-285
    • /
    • 2021
  • When VNDN technology is used as a communication technology for infotainment application services of connected vehicles, it is possible to realize data-centric networking technology in which data is the subject of communication.Vehicle security attacks and hacks, performance degradation during long-distance data transmission, and frequent data loss It is possible to innovate the limitations of the current host-oriented Internet-based infotainment application service technology of connected vehicles. The data packet forwarding issue to deliver critical information data that is very sensitive to delay in the VNDN on a push-based basis to RSU (Road Side Unit), etc. is one of the issues to be solved for realizing VNDN-based application services. We comprehensively analyze existing forwarding techniques to support push-based data traffic under the environment, and compare and analyze each technique in terms of performance.

Development of Vehicle Status Alerts System for Personal Information Leakage Protection using the NFC-based GCM Service (개인정보 유출 방지를 위한 NFC 기반 GCM 서비스를 이용한 차량 상황 알림 시스템 개발)

  • Kang, Hyun-Min;Choi, Hyun-Su;Cha, Kyung-Ae
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.2
    • /
    • pp.317-324
    • /
    • 2016
  • This paper proposes a message transfer application using smartphone with NFC(Near Field Communication) and GCM(Goolge Cloud Messaging) technology for prevention of personal information leakage. In implementing for the proposed system, we design a NFC-based vehicle status alerts service which make it possible to communicate with smartpone message without phone-number between a car driver and an unspecified person. The application provides message communication mechanism without exposing the real phone number, using the NFC tag written with the driver's smartphone device ID and GCM push messages. Through the evaluation result of the actual implemented application, the proposed system can be efficient technology in protection for leakage of personal information such as personal phone- number in daily life.