A Study on Formation and Thermal Decomposition Kinetics of PU Elastomers by Dynamic DSC and TGA Analysis (Dynamic DSC 및 TGA 열분석을 이용한 PU Elastomer의 중합반응 및 열분해 반응 Kinetics에 관한 연구)

  • Yoon, Soo-Koong;Ahn, Won-Sool
    • Elastomers and Composites
    • /
    • v.42 no.1
    • /
    • pp.47-54
    • /
    • 2007
  • Reaction kinetics of polyurethane elastomers (PU) were studied using dynamic DSC and TGA for three PU samples of general purpose (Sample A), high temperature cross-likable CASE purpose with MOCA (Sample B), and RT cross-likable CASE purpose grade (Sample C). From DSC results, sample with MOCA(Sample B) showed lower shift of peak temperature, while showing broader thermograms than those of general purpose grade (Sample A). On the other hand, RT cross-linkable PU grade (Sample C) showed an interesting double mode reaction patterns, i.e., a lower temperature reaction at about $70\;^{\circ}C$, and a higher temperature reaction in the range of $140{\sim}170\;^{\circ}C$, indicating that it requires 2-step reaction process in order to complete the reaction. Once the cross-linking reaction completed, however, TGA results showed that all the samples would be considered to have similar chemical structures, showing similar decomposition processes. Sample C, especially, had showed decomposition properties of both Sample A and Sample B. Formation activation energies calculated from Kissinger method showed 10.39, 65.85, 36.52(Low $T_p$) and 18.21(High $T_p$) kcal/mol, while decomposition activation energies were 31.94, 30.84, 24.16 kcal/mol, respectively.

Effects of Nano-silica/Nano-alumina on Mechanical and Physical Properties of Polyurethane Composites and Coatings

  • Swain, Sarojini;Sharma, Ram Avatar;Bhattacharya, Subhendu;Chaudhary, Lokesh
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.1
    • /
    • pp.1-8
    • /
    • 2013
  • The present approach shows the use of nano-silica/nano-alumina in polyurethane (PU) matrix, which lead to significant improvements in the mechanical and thermal properties of the nano-composite. It is observed that with incorporation of 1% of nano-alumina into the PU matrix, there is an improvement in the tensile strength of around 50%, and for nano-silica the improvement is around 41%, at the same concentration. The morphological data shows that above 3% of the nano particles there are agglomerations in the nanocomposite. Again with the absorption of moisture, there is a decrease in the thermal and mechanical properties of the PU resin, but in this research work it is observed that with the incorporation of the nano particles, in the presence of absorbed moisture there is an improvement in mechanical and thermal properties of the composite, over that of the PU matrix.

Lack of Association of the MDR1 C3435T Polymorphism with Susceptibility to Gastric Cancer and Peptic Ulcer: a Systemic Review and Meta-analysis

  • Wu, Dan-Dan;Zhang, Ji-Xiang;Li, Jiao;Dong, Wei-Guo
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.7
    • /
    • pp.3021-3027
    • /
    • 2014
  • Background: The multidrug resistance 1 gene (MDR1) C3435T polymorphism has been demonstrated to influence the P-glycoprotein (P-gp) activity level which is related to inflammation and carcinogenesis. This meta-analysis was performed to estimate the association between the MDR1 C3435T polymorphism and the risk of gastric cancer (GC) and peptic ulcer (PU). Materials and Methods: A literature search was conducted with PubMed, Embase and the Cochrane library up to November 2013. Odds ratios (ORs) with 95% confidence intervals (CIs) were used to assess the strength of association. Data were analyzed using Review Manager (Version 5.2), and Stata package (version 12.0) for estimation of publication bias. Results: Six case-control studies were included, of which five were for GC and two for PU. Overall, no evidence was found for any association between the MDR1 C3435T polymorphism and the susceptibility to GC and PU. In the stratified analysis by H. pylori infection status, stage and histology classification of GC, and PU type, there was still no significant association between them. Conclusions: This meta-analysis suggested that the MDR1 C3435T polymorphism is not associated with susceptibility to GC and PU. Large and well-designed studies are warranted to validate our findings.

Effect of Acrylic Acid on the Physical Properties of UV-cured Coating Films for Metal Coating (금속코팅용 광경화 코팅필름의 물성에 대한 아크릴산(Acrylic acid)의 영향)

  • Seo, Jong-Chul;Choi, Jun-Suk;Jang, Eui-Sung;Seo, Kwang-Won;Han, Hak-Soo
    • Korean Chemical Engineering Research
    • /
    • v.49 no.1
    • /
    • pp.75-82
    • /
    • 2011
  • Five different composition UV-cured poly(urethane acrylate-co-acrylic acid) (PU-co-AA) films have been prepared by reacting isophorone diisocyanate(IPDI), polycaprolactone triol(PCLT), 2-hydroxyethyl acrylate(HEA), and different weight ratio trimethylolpropane triacrylate(TMPTA) and acrylic acid(AA) as diluents, and characterized using a Fourier transform infrared spectroscopy(FT-IR). The adhesion properties onto the stainless steel, morphology, mechanical hardness, and electrical property of UV-cured PU-co-AA films were investigated as a function of acrylic acid(AA) content. All the PU-co-AA films are structure-less and the molecular ordering and packing density decreased with increasing content of AA due to the flexible structure and -COOH side chains in AA. The crosscut test showed that PU-co-AA films without AA and with low content of AA showed 0% adhesion(0B) and the adhesion of PU-co-AA films in the range of 40-50% AA increased dramatically as the content of AA increases. The pull-off measurements showed that the adhesion force of PU-co-AA films to stainless steel substrate varied from 6 to 31 kgf /$cm^2$ and increased linearly with increasing AA content. The mechanical hardness also decreased as the content of AA increases. This may come from relatively linear and flexible structure in AA and low crystallinity in PU-co-AA films with higher content of AA. The higher AA-containing PU-co-AA films showed higher dielectric constant due to the increase of polarization by introducing AA monomer. In conclusion, the physical properties of UV-cured PU-co-AA films are strongly dependent upon the content of AA and the incorporation of AA in polyurethane acrylate is very useful way to increase the adhesion strength of UV-curable polymers on the stainless steel substrate.

The Effects of Moxibustion at CV12 on Cerebral Blood Flow and Peripheral Blood Flow (중완(中脘)에 신기구 뜸시술이 뇌혈류 및 말초혈류 변화에 미치는 영향)

  • Kim, Do-Hyung;Park, Seung-Chan;Cho, Min-Kyoung;Kwon, Jung-Nam;Hong, Jin-Woo;Lee, In
    • The Journal of Internal Korean Medicine
    • /
    • v.35 no.1
    • /
    • pp.24-36
    • /
    • 2014
  • Objectives : This study was performed to evaluate the effects of moxibustion on cerebral blood flow, peripheral blood flow and blood pressure. Methods : We designed a randomized, cross-over study that included 20 healthy, male volunteers who were randomly assigned to one of two groups (the moxibustion group or the control group). The initial trial was followed by a washout period of one week before the groups were switched and the trial repeated. The cerebral blood flow and peripheral blood flow of the volunteers in both groups were measured by mean velocity (Vm), peak systolic velocity (Vs), pulsatility index (PI), perfusion units (PU) and mean blood pressure (BP) before the intervention (baseline), 30 minutes after the intervention, and again 60 minutes after the intervention. Results : 1. The Vm increased significantly in the moxibustion group. The Vs also constantly increased in moxibustion group, but there was no significant difference. 2. The PI decreased significantly in the control group at 0-30 minutes and in the moxibustion group at 30-60 minutes. 3. The PU constantly decreased in moxibustion group. In control group, the PU decreased at 30 minutes and increased slightly at 60 minutes. 4. The mean blood pressure did not show any significant difference between the two groups. Conclusions : This study shows that moxibustion at CV12 increased the cerebral blood flow. Based on this result, we can suggest that moxibustion at CV12 might be helpful in improving the functional recovery of stroke patients. However, further research needs to be conducted on a larger numbers of subjects in order to confirm these effects.

Assessment of Environmental Radioactivity Surveillance Results around Korean Nuclear Power Utilization Facilities in 2017

  • Kim, Cheol-Su;Lee, Sang-Kuk;Lee, Dong-Myung;Choi, Seok-Won
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.3
    • /
    • pp.118-126
    • /
    • 2019
  • Background: Government conducts environmental radioactivity surveillance for verification purpose around nuclear facilities based on the Nuclear Safety Law and issues a surveillance report every year. This study aims to evaluate the short and the long-term fluctuation of radionuclides detected above MDC and their origins using concentration ratios between these radionuclides. Materials and Methods: Sample media for verification surveillance are air, rainwater, groundwater, soil, and milk for terrestrial samples, and seawater, marine sediment, fish, and seaweed for marine samples. Gamma-emitting radionuclides including $^{137}Cs$, $^{90}Sr$, Pu, $^3H$, and $^{14}C$ are evaluated in these samples. Results and Discussion: According to the result of the environmental radioactivity verification surveillance in the vicinity of nuclear power facilities in 2017, the anthropogenic radionuclides were not detected in most of the environmental samples except for the detection of a trace level of $^{137}Cs$, $^{90}Sr$, Pu, and $^{131}I$ in some samples. Radioactivity concentration ratios between the anthropogenic radionuclides ($^{137}Cs/^{90}Sr$, $^{137}Cs/^{239+240}Pu$, $^{90}Sr/^{239+240}Pu$) were similar to those reported in the environmental samples, which were affected by the global fallout of the past nuclear weapon test, and Pu atomic ratios ($^{240}Pu/^{239}Pu$) in the terrestrial sample and marine sample showed significant differences due to the different input pathway and the Pu source. Radioactive iodine ($^{131}I$) was detected at the range of < $5.6-190mBq{\cdot}kg-fresh^{-1}$ in the gulfweed and sea trumpet collected from the area of Kori and Wolsong intake and discharge. A high level of $^3H$ was observed in the air (Sangbong: $0.688{\pm}0.841Bq{\cdot}m^{-3}$) and the precipitation (Meteorology Post: $199{\pm}126Bq{\cdot}L^{-1}$) samples of the Wolsong nuclear power plant (NPP). $^3H$ concentration in the precipitation and pine needle samples showed typical variation pattern with the distance and the wind direction from the stack due to the gaseous release of $^3H$ in Wolsong NPP. Conclusion: Except for the detection of a trace level of $^{137}Cs$, $^{90}Sr$, Pu, and $^{131}I$ in some samples, anthropogenic radionuclides were below MDC in most of the environmental samples. Overall, no unusual radionuclides and abnormal concentration were detected in the 2017's surveillance result for verification. This research will be available in the assessment of environment around nuclear facilities in the event of radioactive material release.

Comparison of Dose Assessment Programs; DOSE, LIMCAL and PABLM (방사선 피폭선량프로그램 DOS, LIMCAL 및 PABLM의 비교)

  • Park, Hee-Seoung;Cho, Won-Jin;Han, Kyoung-Won;Park, Hun-Hwee
    • Journal of Radiation Protection and Research
    • /
    • v.16 no.1
    • /
    • pp.43-52
    • /
    • 1991
  • A comparison study is performed on dose assessment programs including DOSE, LIMCAL, and PABLM, DOSE is a program developed for preliminary safety assessments of the low- and intermediate- level radioactive waste disposal, and the others are existing programs applicable to similar calculations. The results show acceptable agreement within an order of magnitude(mrem/yr) except for C-14 and Pu-239. PABLM results higher dose for C-14 while lower value for Pu-239 in comparison with those from DOSE or LIMCAL. It is found that the discrepancy in C-14 is due to difference in transport model introduced and that in Pu-239 is from the different value of dose conversion factor to each program.

  • PDF

Effect of Sliding Speed on Wear Characteristics of Polyurethane Seal (미끄럼 속도 변화에 따른 폴리우레탄 씰의 마모 특성)

  • Kim, Hansol;Jeon, Hong Gyu;Chung, Koo-Hyun
    • Tribology and Lubricants
    • /
    • v.34 no.2
    • /
    • pp.49-54
    • /
    • 2018
  • Hydraulic reciprocating seal has been widely used to prevent fluid leakage in hydraulic systems. Also, hydraulic reciprocating seal plays a significant role to provide lubricant film at contacting interface to minimize tribological problems due to sliding with counter material. To predict lifetime of hydraulic reciprocating seal, quantitative understanding of wear characteristics with respect to operating conditions such as normal force and sliding speed is needed. In this work, effect of sliding speed on wear of polyurethane (PU) hydraulic reciprocating seal were experimentally investigated using a pin-on-disk tribo-tester. The wear characteristics of PU specimens were quantitatively determined by comparing the confocal microscope data before and after test. It was found that the wear rate of PU specimens decreased from $4.9{\times}10^{-11}mm^3$ to $1.1{\times}10^{-11}mm^3/Nm$ as sliding speed increased from 120 mm/s to 940 mm/s. Also, it was observed that the friction decreased slightly as the sliding speed increased. Improvement of lubrication state with increasing sliding speed was likely to be responsible for this enhanced friction and wear characteristics. This result also suggests that decrease in sliding distance between PU elastomer and counter materials at lower sliding speed is preferred. Furthermore, the quantitative assessment of wear characteristics of PU specimen may be useful in prediction of lifetime of PU hydraulic reciprocating seal if the allowed degree of wear for failure of the seal is provided.

A Systematic Review of the Effectiveness of Eastern-Western Integrative Medicine for Musculoskeletal Disorders (근골격계 질환의 한·양방협진치료 효과 연구에 대한 체계적 문헌 고찰)

  • Lee, Seung-Jin;Shin, Byung-Cheul;Song, Geun-Sung;Hwang, Eui-Hyoung;Yun, Young-Ju;Cho, Hyun-Woo
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.21 no.4
    • /
    • pp.87-96
    • /
    • 2011
  • Objectives: This study aims to systematically evaluate the effectiveness of Eastern-Western integrative medicine for musculoskeletal disorders compared with Eastern or Western Medicine. Methods: Systematic sea-mes of 9 major Korean databases were conducted for articles published up to July 2011. Searching keyword was "Integrative Medicine". Prospective studies dealt with musculoskeletal disorders by Eastern-Western integrative medicine were included. Quality assessment of included studies was evaluated by Cochrane risk of bias tool. Results: 470 studies in total were seamed, Amalg them 7 studies met our inclusion criteria(3 randomized controlled clinical trials, 2 non-randomized controlled trials and 2 uncontrolled clinical trials). Included studies dealt with lumbar pan(3), shoulder pain(2), pain after traffic injury(1), spinal compression fracture(1). Eastern-Western integrative medicine showed better or equal effect for the treatment of various muscloskeletal disorders compared with Eastern or Western medicine alone. Conclusions: There is very weak evidence for the effectiveness of Eastern-Western integrative medicine for musculoskeletal disorders compared with Eastern or Western medicine alone. Well designed randomized controlled trials with rigorous methodology are needed to evaluate the effectiveness of Eastern-Western integrative medicine objectively in the future.

Development of a Core management Algorithm for Optimal Design of AMBIDEXTER Transient Cores (AMBIDEXTER 천이노심 설계최적화를 위한 노심관리 알고리즘 개발)

  • Yu, Geuk-Jong;Sin, Dong-Hun;So, Sun-Gyu;Lee, Yeong-Jun;Kim, Jin-Seong;O, Se-Gi
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 2004.10a
    • /
    • pp.99-100
    • /
    • 2004
  • AMBIDEXTER-NEC의 천이노심은 $^{Nat}Th$$^{Nat}U$의 주입만으로 전 출력의 Break-even 노심에 도달하기위한 중간 단계이다. 선행연구에서 수행한 전 출력노심인 평형노심의 핵종수밀도에 도달하기 위해서 평형노심에서의 기저물질, 잠재핵분열성물질, 핵분열물질의 수밀도를 각 SEU-기반, Pu-기반, ADS-기반에서 그대로 유지하여 초기노심을 구성하였다. 또 각 시나리오에 대해 최대첨두출력과 원자로의 안전성을 고려해 Excess Reactivity를 5mk 내에서 초기노심을 결정하였다. 각 노심은 주 핵분열성물질 $^{235}U$, $^{239}Pu$$^{233}U$의 핵반응단면적 특성에 따라 평균 전환율이 각각 0.95, 0.83 및 1 .21 로서 핵연료물질의 적절한 선택만으로도 전환로, 연소로 및 증식로로 설계할 수 있음을 보여준다. 이러한 $Th/^{233}U$, U/Pu 핵연료주기를 사용하는 AMBIDEXTER-NEC 용융염핵연료 원자로의 초기노심에서 시작한 천이노심은 평형노심에장전할 충분한 $^{233}U$ 양을 확보해야 하므로 천이노심의 목표는 평형노심 $^{233}U$의 요구량에 최소한의 기간에 가장 적은 외부주입을 통해 도달하는 것이다. 천이노심에서 임계가 유지되는 AMBIDEXTER-NEC 원자로시스템의 3군 핵종변환 코드인 HELIOS-SQUID-AMBIBURN 체제를 개발하였고 그림 1.에 나타내었다. 이 알고리즘은 각 초기노심 중원소의 미시단면적, 중원소를 제외한 원소들의 거시단면적, 임계도를 만족하는 중성자속 및 외부주입율을 계산하여 SQUID 및 AMBIBURN 입력자료를 제공한다. 또한 일정시간 중원소의 핵종농도, 외부주입율과 중성자속이 일정하다는 가정 하 에 반복수행 하고 SEU-기반과 Pu-기반의 경우에는 각각 핵변환을 거쳐 재순환되는 $^{233}U$$^{239}Pu$의 양을 바로 주입하는 최대재순환 경우와 평형노심 요구 장전량에 이를 때까지 시설 내 저장하는 최소재순환 경우로 상황을 모사하였다. 그림 2 는 각 시나리오별 초기노심에서부터 200FPD까지 단위 용융염 체적당 $^{233}U$의 수밀도 시간변화를 나타낸 것이다. 그림을 보면 50일 이후부터는 수밀도의 변화가 일정한 기울기를 보이고 있고 재처리공정에서 $^{233}Pa$를 분리하는 최소재순환의 경우에는 최대재순환보다 2-3%정도에 지나지않아 그림에서 나타내지않았다. SEU-기반 및 Pu-기반에서 $^{233}U$의 증가율이 각각 2.54E+13, 2.81E+13 #/cc/d 로 Pu 기반이 조금 더 큰 증가율을 나타내고 있지만 평형노심 농도 1.04E+20 #/cc/d 에 도달하기 위해서는 두 경우 모두 매우 긴 시간이 걸릴 것을 예상할 수 있다. 요컨대 250MWth AMBIDEXTER-NEC가 평형노심을 이루기 위해 필요로 하는 $^{233}U$을 생산하는데 제안한 SEU-기반, Pu-기반 시나리오는 천이노심주기기간이 전형적인 원자로 수명 3-40년 보다 매우 큰 것으로 나타났다. 따라서 장전될 $^{233}U$의 확보를 위한 최적옵션은 초기노심부터 ADS와 같은 외부생산시설로부터 전량을 공급 받아 운전하는 것이라 판단된다.

  • PDF