• Title/Summary/Keyword: PTFE Membrane

Search Result 141, Processing Time 0.022 seconds

Enhancing Adhesion between Polyphenylene Sulfide Fabric and Polytetrafluoroethylene Film for Thermally Stable Air Filtration Membrane (열안정 공기 여과막용 폴리페닐렌 설파이드 원단과 폴리테트라플루오로에틸렌 필름 사이의 접착력 향상)

  • Jin Uk Kim;Hye Jeong Son;Sang Hoon Kang;Chang Soo Lee
    • Membrane Journal
    • /
    • v.33 no.4
    • /
    • pp.201-210
    • /
    • 2023
  • Dust filter membranes play a crucial role in human life and various industries, as they contribute to several important aspects of human health, safety, and environmental protection. This study presents the development of a polysulfone@polyphenylene sulfide/polytetrafluoroethylene (PSf@PPS/ePTFE) composite dust filter membrane with excellent thermal stability and adhesion properties for high-temperature conditions. FT-IR analysis confirms successful impregnation of PSf adhesive onto PPS fabric and interaction with ePTFE support. FE-SEM images reveal improved fiber interconnection and adhesion with increased PSf concentration. PSf@PPS/ePTFE-5 exhibits the most suitable porous structure. The composite membrane demonstrates exceptional thermal stability up to 400℃. Peel resistance tests show sufficient adhesion for dust filtration, ensuring reliable performance under tough, high-temperature conditions without compromising air permeability. This membrane offers promising potential for industrial applications. Further optimizations and applications can be explored.

Bacterial Adhesion And Penetration To e-PTFE Membrane Used For The Guided Tissue Regeneration (치주조직재생유도술용 비흡수성 차폐막 (e-PTFE membrane)에의 세균부착 및 침투)

  • Chung, Hyun-Ju;Lee, Sung-Mi;Lee, Ho-Jae;Kim, Ok-Soo
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.1
    • /
    • pp.103-116
    • /
    • 1996
  • This study was performed to observe the bacterial adhesion and penetration to e-PTFE membrane following guided tissue regeneration(GTR) procedure and to evaluate the association of the membrane exposure and bacterial contamination with the clinical outcome. For the study, ten infrabony defects in 9 patient were treated by mucoperiosteal flap operation including placement of the e-PTFE membrane. The treated teeth were monitored weekly for the membrane exposure, gingival recession and gingival inflammation. The membranes were retrieved after 4 to 6 weeks, examined by SEM for bacterial contamination and adherent connective tisue elements, and observed under LM for the bacterial penetration into membrane. Three months postsurgery, the defect sites were clinically reexamined for the changes in attachment level and probing depth. Comparison of the ultrastuctural findings and clinical outcome revealed that extent of membrane exposure and bacterial contamination of the membrane was inversely associated with clinical attachment gain. From this finding, the extent of membrane exposure and the bacterial contamination on the apical portion of the e-PTFE membrane at the time of removal seemed to be a critical determinant on the clinical outcome of GTR and the membrane exposure needs to be controlled for optimal results.

  • PDF

A Study on Physical and Mechanical Properties of Breathable Waterproof Fabrics Manufactured with PTFE Membrane-fabric Composite (PTFE막-직물 복합체로 제조된 투습방수직물의 물성 및 역학특성에 관한 연구)

  • Jeong, Won-Young;An, Seung-Kook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.26 no.12
    • /
    • pp.1685-1693
    • /
    • 2002
  • 다양한 용도로 사용되고 있는 라미네 이 팅 직물은 주로 별도로 제조된 고분자 필름 또는 막을 접착제, 열, 압력 등을 이용하여 기포(基布)와 결합시키는 방법으로 제조되어 진다. 이축연신시킨 Poly(tetrafluoroethylene) (PTFE) sheet는 매우 우수한 높은 투과성을 지니는 다공성 물질이 며, 본 연구에서는 이 막을 나일론 직물에 라미네이팅시킨 투습방수직물을 시료로 사용하여 라미네이팅 후의 역학특성 변화를 분석 하였다. 라미네이팅에 따른 투습방수직물의 물성과 역학특성의 변화에 관하여 살펴본 결과 다음과 같은 결과를 얻었다. 3-layer 라미네이팅 직물(base fabric-PTFE membrane-knitted lining)의 인열강도는 2-layer라미네이팅 직물 (base fabric-PTFE membrane)에 비해 매우 높게 나타났으며, 가공 전 직물과 비교하여 코팅직물에서 나타난 것과 같은 인열강도의 감소는 나타나지 않았다. 직물-PTFE 막 복합체 의 경우, 라미네 이 팅 이 파단강도 및 파단신도 의 증가에 기여 한 것으로 나타났으며 특히 3-layer 라미네이팅 직물의 경우, 신장률이 20%를 넘어서면서 강도가 현저히 증가하였다. 의복을 착용하였을 때 가해질 수 있을 정도의 소변형(small deformation) 하에서의 역학특성 에 있어서는 라미네이팅에 의해 전단특성이 가장 유의한 변화를 나타내었다. 전단강성(G)과 전단 히스테리시스 (2HG,2HG5)모두 증가하였고, primary hand value 중에서는 stiffness 가장 현저한 증가를 나타내었다

Comparison of Degradation due to Fenton Reaction between Reinforced and Non-reinforced Membranes Used in PEMFC (PEMFC에 사용되는 강화막과 비강화막의 Fenton 반응에 의한 열화 비교)

  • Oh, Sohyeong;Yoo, Donggeun;Lee, Mihwa;Park, Jisang;Park, Kwon-Pil
    • Korean Chemical Engineering Research
    • /
    • v.59 no.4
    • /
    • pp.508-513
    • /
    • 2021
  • In order to improve the durability of a proton exchange membrane fuel cells (PEMFC), it is essential to improve the durability of the polymer membrane. In order to improve the durability of the membrane, an e-PTFE support and a radical scavenger are added. In this study, the chemical durability of the reinforced membrane with ePTFE support and the non-reinforced membrane was compared by Fenton reaction. In the Fenton experiment of the polymer membrane without the addition of a radical scavenger, the absorption rate of hydrogen peroxide solution and iron ions through the cross section of the specimen cut into small pieces was higher in the reinforced membrane, so that the fluorine outflow concentration was higher. According to the type and amount of radical scavenger added, the fluorine outflow concentration of the reinforced membrane has a large difference of more than 3 times, indicating that the effect of the radical scavenger was stronger than that of the support.

Perfluorinated Sulfonic Acid Ionomer-PTFE Pore-filling Membranes for Polymer Electrolyte Membrane Fuel Cells (고분자전해질연료전지용 과불소계 술폰화 이오노머-PTFE 강화막)

  • Kang, Seong Eun;Lee, Chang Hyun
    • Membrane Journal
    • /
    • v.25 no.2
    • /
    • pp.171-179
    • /
    • 2015
  • Perfluorinated sulfonic acid ionomers (PFSAs) have been widely as solid electrolyte materials for polymer electrolyte membrane fuel cells, since they exhibit excellent chemical durability under their harsh application conditions as well as good proton conductivity. Even PFSA materials, however, suffer from physical failures associated with repeated membrane swelling and deswelling, resulting in fairly reduced electrochemical lifetime. In this study, pore-filling membranes are prepared by impregnating a Nafion ionomer into the pore of a porous PTFE support film and their fundamental characteristics are evaluated. The developed pore-filling membranes exhibit extremely high proton conductivity of about $0.5S\;cm^{-1}@90^{\circ}C$ in liquid water.

The effect of maintenance period of non-resorbable membrane on bone regeneration in rabbit calvarial defects (가토 두개골 결손부에서 비흡수성 차단막의 유지 기간에 따른 골조직 형성효과)

  • Jung, Min-Gu;Jang, Hyun-Seon;Kim, Byung-Ock
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.3
    • /
    • pp.543-551
    • /
    • 2007
  • When clinicians faced with an insufficient volume of supporting bone on ideally esthetic and bio-mechanical position for dental implantation, guided bone regeneration(GBR) was indicated. Although GBR has wide application at clinic, proper time of membrane removal remains qustionable in using non-resorbable membrane, such as non-expanded polytetrafluoroethylene(PTFE), The aim of this study was to compare the effect of maintenance period of PTFE membrane on bone regeneration in rabbit calvarial defects. Eight adult New Zealand white female rabbits were used in this study. Four defects were surgically made in their calvaria. Using a trephine bur, 4 'through and through' defects were created and classified into 3 groups, which were consisted of control group(no graft), experimental group 1(autogenous bone)and experimental group 2(deproteinized bovine bone; $OCS-B^{(R)}$). The defects were covered with PTFE membrane($Cytoplast^{(R)}$). Membranes were removed after 1, 2, 4 and 8 weeks post-GBR procedure in 2 rabbits repectively, All rabbits were sacrificed after 8 week post-GBR procedure. Specimens were harvested and observed histologically. The results were as follow; 1) The use of graft material and membrane was necessary in GBR procedure. 2) When PTFE membranes were removed early, the most favorable bone regeneration was revealed in experimental group T, followed by experimental group II and control group. 3) On GBR, it is recommended that membrane should maintain for 4 weeks with autogenous graft. As well, the use of xenograft need longer maintenance period than autogenous bone. Further evaluations will be needed, such as histomorphologic research, more species and different kinds of graft materials. And on the basis of these studies, clinical researches would be required.

Chemical Degradation of e-PTFE Support Used in PEMFC after Fenton Reaction (고분자연료전지에 사용되는 e-PTFE 지지체의 펜톤반응 후 화학적 열화)

  • Oh, Sohyeong;Lim, Daehyun;Lee, Mooseok;Lee, Donghoon;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.58 no.4
    • /
    • pp.536-540
    • /
    • 2020
  • The support of the PEMFC membrane plays a key role in improving mechanical durability. The e-PTFE used as a support is chemically stable, so electro-chemical degradation in the PEMFC driving process has been rarely studied. In this study, we investigated whether e-PTFE is chemically stable to radicals and hydrogen peroxide during Fenton reaction. After the Fenton reaction, the main chain of e-PTFE broke, resulting in a change in the chemical structure and morphology of the support, resulting in a decrease in tensile strength. The results of this study showed that electrochemical degradation of the membrane ionomer in the PEMFC process occurs inside the membrane by radicals and hydrogen peroxide, so that electrochemical degradation may also occur at the e-PTFE support in the cell.

Effect of Support on the Performance and Electrochemical Durability of Membrane in PEMFC (PEMFC의 고분자막에서 지지체가 고분자전해질 막 성능 및 전기화학적 내구성에 미치는 영향)

  • Oh, Sohyung;Lim, Dae Hyun;Lee, Daewoong;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.58 no.4
    • /
    • pp.524-529
    • /
    • 2020
  • To increase the mechanical durability of the proton exchange membrane fuel cells, a reinforced membrane in which a support is placed in the polymer membrane is used. The support mainly uses e-PTFE, which is hydrophobic and does not transfer ions, which may cause performance degradation. In this study, we investigated the effect of e-PTFE support on PEMFC performance and electrochemical durability. In this study, the reinforced membrane with the support was compared with the single membrane (non-reinforced membrane). Due to the hydrophobicity of the support, the water diffusion coefficient of the reinforced membrane was lower than that of the single membrane. The reinforced membrane had a lower water diffusion coefficient, resulting in higher HFR, which is the membrane migration resistance of ions, than that of a single membrane. Due to the low hydrogen permeability of the support, the OCV of the reinforced membrane was higher than that of the single membrane. The support was shown to reduce the hydrogen permeability, thereby reducing the rate of radical generation, thereby improving the electrochemical durability of the reinforced membrane.

Secondary closure of an extraction socket using the double-membrane guided bone regeneration technique with immediate implant placement

  • Yun, Jeong-Ho;Jun, Choong-Man;Oh, Nam-Sik
    • Journal of Periodontal and Implant Science
    • /
    • v.41 no.5
    • /
    • pp.253-258
    • /
    • 2011
  • Purpose: Immediate implantation presents challenges regarding site healing, osseointegration, and obtaining complete soft-tissue coverage of the extraction socket, especially in the posterior area. This last issue is addressed herein using the double-membrane (collagen membrane+high-density polytetrafluoroethylene [dPTFE] membrane) technique in two clinical cases of posterior immediate implant placement. Methods: An implant was placed immediately after atraumatically extracting the maxillary posterior tooth. The gap between the coronal portion of the fixture and the adjacent bony walls was filled with allograft material. In addition, a collagen membrane (lower) and dPTFE membrane (upper) were placed in a layer-by-layer manner to enable the closure of the extraction socket without a primary flap closure, thus facilitating the preservation of keratinized mucosa. The upper dPTFE membrane was left exposed for 4 weeks, after which the membrane was gently removed using forceps without flap elevation. Results: There was considerable plaque deposition on the outer surface of the dPTFE membrane but not on the inner surface. Moreover, scanning electron microscopy of the removed membrane revealed only a small amount of bacteria on the inner surface of the membrane. The peri-implant tissue was favorable both clinically and radiographically after a conventional dental-implant healing period. Conclusions: Secondary closure of the extraction socket and immediate guided bone regeneration using the double-membrane technique may produce a good clinical outcome after immediate placement of a dental implant in the posterior area.

Histologic evaluation of the regenerated bone using bone graft materials (수종의 골이식재를 이용한 유도재생골의 조직학적 평가)

  • Ryu, Ho-Chul;Park, Joon-Bong;Kwon, Young-Hyuk;Herr, Yeek;Chung, Jong-Hyuk;Jue, Seong-Suk
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.2
    • /
    • pp.289-303
    • /
    • 2006
  • This study was performed to evaluate the effect of bone graft materials including demineralized freeze-dried bone, freeze-dried bone, deproteinized bovine bone on space-making capacity and bone formation in guided bone regeneration with titanium reinforced ePTFE membrane(TR-ePTFE). Adult male rabbits(mean BW 2kg) were used in this study. Intramarrow penetration defects were surgically created with round bur on calvaria of rabbits. TR-ePTFE membrane was adapted to calvarial defect and bone graft materials were placed. Animals were sacrificed at 2, 8, 12 weeks after surgery. Non-decalcified specimens were processed for histologic analysis and prepared with Villaneuva bone stain. The results of this study were as follows: 1. TR-ePTFE membrane was biocompatible and capable of maintaining the space-making. 2. Tissue integration was not good at TR-ePTFE membrane. Fixation was not enough. so, wound stabilization was not good. 3. In animals using deproteinized bovine bone, demineralized freeze-dried bone, bone formation was little. 4. In animals using freeze-dried bone, bone formation was better. Within the above results, bone formation may be inhibited when wound stabilizafion was not good.