• Title/Summary/Keyword: PT inverter

Search Result 12, Processing Time 0.022 seconds

Design of the full-Bridge type Piezoelectric Inverter (압전 변압기 이용 Full-Bridge형 인버터 설계)

  • 임영철
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.78-81
    • /
    • 2000
  • The backlight inverter used in a laptop computer is investigated in this paper. It has been difficult for the electromagnetic transformer in the inverter to have a high efficiency and compact profile. In this study the piezoelectric transformer(PT) is used to reduce the loss and volume compared to the standard electromagnetic transformer. Comparison with the experimental inverter with the PT has been shown to validated the simulation program using the equivalent circuit model of the PT. A simple dimming control circuit was experimentally demonstrated and shown to have broad control.

  • PDF

Steady-state Characteristics of the Piezoelectric Transformer and the Design of the Piezoelectric Inverter for Cold Cathode Fluorescent Lamp (압전 변압기의 정상상태 특성과 고효율 냉 음극 방전램프용 인버터 설계)

  • Gwon, Gi-Hyeon;Im, Yeong-Cheol;Yang, Seung-Hak;Jeong, Yeong-Guk
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.49 no.4
    • /
    • pp.175-182
    • /
    • 2000
  • The back-light inverter used in the laptop computer is designed in this paper. It has been difficult for electromagnetic transformer to enhance the efficiency and compact profile of the inverter. In this paper, (1) the piezoelectric transformer (PT) is used for reducing the loss; (2) the volumes of core and winding coil are used in electromagnetic transformer, and (3) the half-bridge series parallel resonant circuit is used in the driver of the inverter. The modified PT for this paper and the equivalent circuit are supported by the simulation program. The result of the experiment shows more than 91% improvement in terms of the efficiency.

  • PDF

Maximum-Efficiency Tracking Scheme for Piezoelectric-Transformer Inverter with Dimming Control

  • Nakashima Satoshi;Ogasawara Hiroshi;Kakehashi Hidenori;Ninomiya Tamotsu
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.7-10
    • /
    • 2001
  • This paper provides a solution for the problem of efficiency decrease caused by load variation. A novel control scheme of tracking the PT's operation frequency for the maximum efficiency is proposed. As a result, a high efficiency over $80\%$ has been achieved even under the output-current decrease down to $10\%$ of the full load current.

  • PDF

Steady-State Characteristics of the Piezoelectric Transformer and the Design of the Piezoelectric Inverter (압전 변압기 정상상태 특성과 고효율 냉 음극 방전등용 인버터 설계)

  • Kweon, G.H.;Lim, Y.C.;Yang, S.H.;Jung, Y.K.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2616-2619
    • /
    • 1999
  • The Backlight inverter used in the laptop computer is designed in this study. It has been difficult for electromagnetic transformer to enhance the efficiency and compact profile. In this study, (l) the piezoelectric transformer(PT) is used for reducing the loss: (2) the volume of core and winding coil are used in electromagnetic transformer, and (3) the zero voltage switching(ZVS) is used in the driver of the resonant circuit. The modified PT for this paper and the equivalent circuit are supported by the simulation program. ZVS is achieved by Half-Bridge inverter circuit. The result of the experiment shows more than 91% improvement in terms of the efficiency.

  • PDF

Design of the inverter for driving CCFL (냉음극 방전 램프 구동용 인버터 설계)

  • Jun, Ho-Ik;Cho, Hyun-Seob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.4
    • /
    • pp.2320-2323
    • /
    • 2014
  • Piezoelectric inverter for driving CCFL is designed in this study. Of them, CCFL is generally used because it has advantages such as small size, high efficiency and good brightness characteristics. the description of the piezoelectric effect is not present here and can be easily found in numerous publications as well as complex equations and formulae. What is the most important to understand is that "they are different" one cannot just change an electromagnetic transformer(EMT) for a piezoelectric one. The simulation program supports the modeled piezoelectric inverter for this paper and the equivalent circuit. The result of the experiment shows more than 90% improvement in terms of the efficiency.

Design of Inverter for Driving the Multi-lamp using an Piezoelectric Transformers (압전 변압기를 이용한 멀티 램프 구동용 인버터 설계)

  • Cho Sung-Koo;Lim Young-Cheol;Yang Seung-Hak
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.2
    • /
    • pp.130-137
    • /
    • 2005
  • LCD needs a backlight that is a light source as a photodetector that has a light modulation function and CCFL is used usually. Inverter that composes using existent winding transformer operates multi lamps, however, this efficiency falls by losses of core or winding and volume or weight increases or there is danger of fire by overheating. In order to solve these problems, a multi lamp driving Inverter using PT is composed according to the design guideline in this paper. We conformed whether the multi lamp drive method using EEFL that a current burden is less in applicable to piezoelectric inverter, and used the method that connect two piezoelectric transformers by parallel to an inverter.

A 12-bit Hybrid Digital Pulse Width Modulator

  • Lu, Jing;Lee, Ho Joon;Kim, Yong-Bin;Kim, Kyung Ki
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.20 no.1
    • /
    • pp.1-7
    • /
    • 2015
  • In this paper, a 12-bit high resolution, power and area efficiency hybrid digital pulse width modulator (DPWM) with process and temperature (PT) calibration has been proposed for digital controlled DC-DC converters. The hybrid structure of DPWM combines a 6-bit differential tapped delay line ring-mux digital-to-time converter (DTC) schema and a 6-bit counter-comparator DTC schema, resulting in a power and area saving solution. Furthermore, since the 6-bit differential delay line ring oscillator serves as the clock to the high 6-bit counter-comparator DTC, a high frequency clock is eliminated, and the power is significantly saved. In order to have a simple delay cell and flexible delay time controllability, a voltage controlled inverter is adopted to build the deferential delay cell, which allows fine-tuning of the delay time. The PT calibration circuit is composed of process and temperature monitors, two 2-bit flash ADCs and a lookup table. The monitor circuits sense the PT (Process and Temperature) variations, and the flash ADC converts the data into a digital code. The complete circuits design has been verified under different corners of CMOS 0.18um process technology node.

Comparative Analysis of Driving Inverters for the Piezo-Electric Transformer

  • Ishizuka, Yoichi;Shimokawa, Souichirou;Kurokawa, Fujio;Matsuo, Hirofumi;Kimura, Kengo;Aoike, Nanjo
    • Proceedings of the IEEK Conference
    • /
    • 2002.07c
    • /
    • pp.1390-1393
    • /
    • 2002
  • Comparative analysis of driving inverters for piezo-electric transformer (PT) is performed and the suit- able drive circuit for portable devices such as personal digital assistants (PDA) is chosen with the experiment in this paper. As a result, a single-switch inverter with a small two winding reactor is chosen, and then the advantages of this method are clarified. It is also confirmed that the driving inverter with this method enables to realize a stabilized AC 400v output and 82% power efficiency from DC 3V input under the conditions of the variations of load current or input voltage from the experiments. Piezo-electric Transformer, Back-Light System, Single-Switch Driving Circuits, Control Method

  • PDF

Analytical Model of Conduction and Switching Losses of Matrix-Z-Source Converter

  • You, Keping;Rahman, M.F.
    • Journal of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.275-287
    • /
    • 2009
  • This paper investigates analytical models of Conduction and Switching Losses (CASLs) of a matrix-Z-source converter (MZC). Two analytical models of the CASLs are obtained through the examination of operating principles for a Z-source inverter and ac-dc matrix converter respectively. Based on the two models, the analytical model of CASLs for a MZC is constructed and visualized over a range of exemplified operating- points, each of which is defined by the combination of power factor (pt) and modulation index (M). The model provides a measurable way to approximate the total losses of the MZC.

Safety Assessment for PCS of Photovoltaic and Energy Storage System Applying FTA (FTA를 적용한 태양광 발전 및 ESS 연계형 PCS의 안전성 평가)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Kim, Eui-Sik;Nam, Ki-Gong;Jeong, Cheon-Kee
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.1
    • /
    • pp.14-20
    • /
    • 2019
  • This paper presents a safety assessment based approach for the safe operation for PCS(Power Conditioning System) of photovoltaic and energy storage systems, applying FTA. The approach established top events as power outage and a failure likely to cause the largest damage among the potential risks of PCS. Then the Minimal Cut Set (MCS) and the importance of basic events were analyzed for implementing risk assessment. To cope with the objects, the components and their functions of PCS were categorized. To calculate the MCS frequency based on IEEE J Photovolt 2013, IEEE Std. 493-2007 and RAC (EPRD, NPRD), the failure rate and failure mode were produced regarding the basic events. In order to analyze the top event of failure and power outage, it was assumed that failures occurred in DC breaker, AC breaker, SMPS, DC filter, Inverter, CT, PT, DSP board, HMI, AC reactor, MC and EMI filter and Fault Tree was drawn. It is expected that the MCS and the importance of basic event resulting from this study will help find and remove the causes of failure and power outage in PCS for efficient safety management.