A study on BTB HVDC location in metropolitan area considering fault current analysis (고장전류를 고려한 수도권 BTB HVDC 위치선정 연구)

  • Yoon, Min-Han;Jang, Gil-Soo;Park, Jung-Soo;Jang, Byung-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.274-275
    • /
    • 2011
  • Fault current problems is considered a serious issue in the power system because large fault currents not only cause many side effects to the equipments of power system but also lead to severe problems, such as blackouts. This paper deals with the structural analysis and 3-phase fault current stability of the future Seoul metropolitan power system. The simulation composition and analysis are performed with the 4th KEPCO power supply planning data using PSS/e. Through the results of the simulations, it can be observed that the future Seoul metropolitan system results in a fault current which exceeds the circuit breaker (CB) rate. This unremovable fault current can cause critical damage to power system. To resolve the problem, the algorithm for the application of Voltage Sourced Converter Back-to-Back High Voltage Direct Current (VSC BTB HVDC) is being proposed. where the most suitable location for solving fault current problem in Seoul metropolitan area is being implemented.

  • PDF

A Study on Load Modeling of Industrial Area Based on DFR measurements (DFR 측정 기반 산업단지 부하모델링 구현 연구)

  • Son, Seo-Eun;Lee, Soo-Hyung;Park, Jung-Wook;Song, Kyung-Bin;Lee, Sung-Moo;Jo, Jong-Man
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.182-183
    • /
    • 2011
  • 본 논문은 DFR 측정기반 산업단지 부하모델링에 관한 연구이다. 기존 국내에서 사용되고 있는 개별 부하모델의 단점을 보완하고 국내 산업단지 부하의 특성을 정확하게 파악하기 위하여 측정기반 접근법에 의한 부하모델을 선정하였다. 선정된 부하모델은 정적 부하모델과 동적 부하모델을 결합한 복합 부하모델로, 이러한 부하모델을 구축하기 위하여 국내 산업단지 A 변전소에 고장기록계(DFR)을 설치하였다. DFR 측정 데이터 기반 부하모델 구축에 앞서, 계통 해석 프로그램인 PSS/E로 DFR이 설치된 A 변전소를 모델링하여 취득된 데이터로 선정된 부하모델을 검증하였다.

  • PDF

Analysis of the Effect on Power System with WTGs (풍력발전기 출력에 따른 계통영향 분석)

  • Kim, Hyeong-Taek;Kim, Se-Ho;Myung, Ho-San;Kim, Yeong-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.330-331
    • /
    • 2011
  • 제주도의 풍부한 바람자원과 육지에 비해 높은 SMP로 많은 풍력사업자들이 제주지역에 풍력단지를 조성하기 위해 노력을 기울이고 있다. 향후 대규모 풍력단지가 조성된다면 풍속변화에 따라 생산되는 전력의 변동은 커질 것이다. 이러한 풍력발전기의 가변성으로 인한 출력변동은 계통의 주파수와 국지적인 모선 전압의 변동을 유발할 수 있다. 따라서 전력계통 신뢰도와 안정성을 위하여, 계통 운영 상황을 고려한 풍력발전기 운영이 요구된다. 본 논문에서는 PSS/E를 통해 가상 계통을 구현하여 풍력발전기의 무효전력 공급 유 무에 따라 계통에 미치는 영향을 선로의 무효전력과 모선 전압 측면에서 분석하였다.

  • PDF

Congestion Cost Reduction considered Carbon Tax using Voltage-Sourced Converter Back-to-Back HVDC (전압형 Back-to-Back HVDC를 이용한 수도권 전력 계통의 탄소세를 적용한 혼잡 비용 절감 방안 연구)

  • Kwon, Do-Hoon;Lee, Dong-Woo;Moon, Seung-Il
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.242-243
    • /
    • 2011
  • 우리나라의 전력 계통은 수도권에 부하가 집중되어 있는 반면에 발전 설비는 비수도권에 위치해서 대규모 북상 조류가 발생한다. 이런 대규모의 장거리 전력 전송은 계통의 안정도를 떨어뜨리고 사고시 전력 계통에 불안정을 야기할 수 있다. 때문에 이를 방지하기 위해 송전전력을 제한하게 되고 그로 인한 혼잡비용이 발생한다. 전압형 BTB(Back-to-Back) HVDC의 경우 유효전력과 무효전력의 독립적인 제어가 가능하므로 전압형 BTB HVDC를 수도권 전력 계통에 투입시켜 무효전력을 보상해줄 수 있다. 무효전력을 보상해주면 수도권으로의 융통전력이 더 증가하게 되고 그로 인한 혼잡비용을 절감시킬 수 있다. 본 논문에서는 PSS/E를 이용하여 전압형 BTB HVDC를 수도권 전력망에 투입하여 융통전력을 계산하고 이를 토대로 탄소세를 고려한 혼잡 비용절감 효과를 알아본다.

  • PDF

A Study on the Maximum Capacity Rate of Distributed Generation Considering Power System Transient Stability (분산형전원 투입시 전력계통의 과도안정도 유지 한계용량 산정)

  • Kim, Yong-Ha;Lim, Hyun-Sung;Jung, Hyun-Sung;Back, Bum-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.4
    • /
    • pp.718-724
    • /
    • 2009
  • Recently, Increase of energy consumption is continued accordingly because economy is constant growth. so we need long term of energy supply stability and develop new energy source. The effort of environmental improvement is necessary and our country has to educe conservatory gas in these situation, our energy policy is summarized that minimizes energy consumption and uses kinds of energy source. This paper studied some effort of stability that distributed generation put in electric system through line fault, sudden load change. And then this paper calculated penetrated level of distributed generation in system transient stability.

Modelling development of the Electromagnetic Transient Analysis of the JeJu Power System (제주 전력계통의 전자기과도해석 모델링 개발)

  • Choi, Joon-Ho;Nam, Hae-Kon;Nam, Soon-Ryul
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.223-225
    • /
    • 2008
  • 본 논문은 제주 계통의 전자기적 과도 해석을 위해 상세한 전자기 과도해석 모델링 개발 및 절차에 관한 내용을 다루고 있다. 제주 전력계통의 모델링은 크게 제주도내의 화력발전 모델링과 육지와 연계된 해남-제주간 Bi-pole HVDC 모델링으로 구분하여 개발하였고 이를 통합하였다. 모델링의 정확성 확보를 위해 기존에 개발된 PSS/E 모델링과 비교하여 개발하였다. 사례연구로는 HVDC상세 모델과 제주 AC 전력계통을 통합한 과도해석 모델을 사용하여 부하 급변등, 사고해석 등을 사례연구를 수행하였다.

  • PDF

EMTDC simulation study on Frequency property due to Power Variations of Wind Generators (EMTDC를 이용한 풍력발전 출력변동의 주파수 영향 분석)

  • Chun, Yeong-Han;Jeong, Bong-Sang;Lee, Su-Mi;Park, Min-Su;Maeng, Jong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.488-490
    • /
    • 2008
  • 지구 온난화 및 에너지 위기에 대비하여 신재생 에너지의 비율이 점점 증가하고 있고 이에 따라 전력계통의 운영 환경도 이에 따라 변하고 있다. 특히 풍력의 경우에는 현재에도 대용량이 계통에 연계가 되어 운전이 되고 있기 때문에 풍력발전기의 계통에 미치는 영향에 대한 연구는 이전부터 진행이 되어 왔다. 본 연구에서는 EMTDC를 이용한 시뮬레이션을 통해 이전에 수행한 PSS/E의 연구 결과와 비교 분석하여 그 차이점에 대해서 분석하고 일관된 결과를 얻기 위한 계통의 데이터 및 시뮬레이션 조건에 대해서 생각해 보았다.

  • PDF

Stability Analysis of Jeiu Power System added with HVDC (HVDC 추가도입에 대한 제주도 계통의 정태 안정도 분석)

  • Shin, Seong-Su;Kim, Do-Hyung;Kim, Jae-Eon
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.491-493
    • /
    • 2008
  • This paper presents results of comparing CSC HVDC with VSC HVDC on the stability in case of connecting Haenam to Jeju electrical power system, the steady-state stability in the case of Jeju electrical power system with CSC HYDC or VSC HVDC, is validated through PV curve, QV curve of Jeju electrical power system. And in the case of CSC HVDC, it is considered that synchronous condenser is connected or not. The results are compared each other. PSS/E simulation tool is used for the steady-state stability analysis.

  • PDF

Dynamic Interaction Research among Static Var Compensators (정지형 무효 전력 보상기 간의 상호 간섭 연구)

  • Kim, Hee-Jin;Hur, Kyeon;Chang, Byung-Hoon;Ha, Yong-Gu
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.455-456
    • /
    • 2011
  • 전력의 흐름을 제어하기 위하여 유연 송전 시스템(Flexible AC Transmission System, FACTS)이 전력 계통에 다수 설치되었고, 앞으로도 설치되는 FACTS 기기의 수가 늘어날 예정이다. 특히, 전력수요가 많은 수도권에는 안정도와 안전도를 확보하기 위해 FACTS 중 하나인 정지형 무효 전력 보상기(Static Var Compensator, SVC)의 설치가 필요하다. 하지만 SVC가 수도권에 다수 설치되면 SVC 기기 간에 상호 간섭 가능성이 있다. 따라서 본 논문에서는 SVC 기기 간의 상호간섭 가능성을 제시하고 Kundur 모델의 PSS/e 시뮬레이션을 통해 SVC 기기 간의 상호 간섭이 발생할 수 있음을 확인하고자 한다.

  • PDF

The economic evaluation for the congestion Obliteration by Installation of transmission line (송전선로 신설로 인한 혼잡해소에 대한 경제성 평가)

  • Choy, Young-Do;Seo, Chul-Soo;Yoon, Gi-Gab;Park, Sang-Ho;Kim, Chang-Woo;Shin, Je-Seok;Kim, Jin-O
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.428-429
    • /
    • 2011
  • 전력 수요가 기하급수적으로 증가함에 따라 발전설비들의 신설의 필요성뿐 아니라 효율적인 전력수송 및 배분을 위한 송전설비의 신설의 필요성 또한 높아지고 있다. 이에 송전설비의 신설에 대한 계획 단계에서 건설비용뿐 아니라 운영비용에 대한 경제적 효과를 고려하여야 한다. 경제적인 운영비용의 평가를 수행하기 위하여, PSS/E 최적조류계산(OPF)을 활용하여 제약비용, 혼잡비용, 손실비용을 산정하는 명확한 절차를 제시한다.

  • PDF