• Title/Summary/Keyword: PSD센서

Search Result 71, Processing Time 0.035 seconds

Analysis on the Impact of UWB Sensor on Broadband Wireless Communication System (UWB 센서에 의한 광대역 무선 시스템의 간섭 영향 분석)

  • Cheng, Yan-Ming;Lee, Il-Kyoo;Lee, Yong-Woo;Oh, Seung-Hyeub;Cha, Jae-Sang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.3
    • /
    • pp.83-89
    • /
    • 2010
  • This paper presents the impacts of Ultra Wide-Band(UWB) sensor using frequency of 4.5 GHz on Broadband Wireless communication system which uses frequency of 4.5 GHz. The Minimum Coupling Loss (MCL) method and Spectrum Engineering Advanced Monte Carlo Analysis Tool (SEAMCAT) is used to evaluate the interference effects of UWB sensor on Broadband Wireless communication system, respectively. The minimum protection distance between single UWB sensor and mobile station of Broadband Wireless communication system should be more than 1.2 m to guarantee the co-existence. In case of multiple UWB sensors, UWB transmitting PSD of around -68.5 dBm/MHz below should be required to guarantee interference probability of 5% below for mobile station of Broadband Wireless communication system.

Comparative study for PD pattern analysis using different type of sensors applicable to on-line monitoring of GIS (GIS On-line Monitoring 센서특성과 부분방전 패턴분석 결과 비교연구)

  • Lee, Ji-Chul;Jung, Seoung-Young;Chang, Yong-Moo;Koo, Ja-Yoon;Choi, Jae-Ok;Lee, Young-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.101-103
    • /
    • 2004
  • 본 연구는 전력 계통에 상용화된 $SF_6$ GIS(Gas Insulated Switchgear) 내부에서 발생되는 부분방전 검출 방법을 개발하기 위하여, GIS의 내부에 유입되거나 생산과정에서 형성 될 수 있는 세 가지 결함들을 연구용 GIS 내부에 모의하였으며 또한 특성이 다른 센서(UHF, CT, AE)를 제작 또는 이용하여 그 부분방전 패턴 결과와 주파수 분석 결과를 상호 비교하였다. 실험결과에 의하면, 동일한 결함에 의하여 센서의 검출 결과는 다르게 나타나거나 전혀 검출이 되지 않음이 밝혀졌다. 따라서, 부분방전 패턴분석을 하나의 분석방법에 의존하는 것은 바람직하지 못한 것으로 사료되며 신뢰성 있는 GIS 진단을 위하여 적합한 센서개발 및 두 가지 이상의 분석 방법이 병행되는 것이 절대적으로 필요한 것으로 사료된다.

  • PDF

Sound PSD Image based Tool Condition Monitoring using CNN in Machining Process (생산 공정에서 CNN을 이용한 음향 PSD 영상 기반 공구 상태 진단 기법)

  • Lee, Kyeong-Min
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.7
    • /
    • pp.981-988
    • /
    • 2022
  • The intelligent production plant called smart factories that apply information and communication technology (ICT) are collecting data in real time through various sensors. Recently, researches that effectively applying to these collected data have gained a lot of attention. This paper proposes a method for the tool condition monitoring based on the sound signal generated in machining process. First, it not only detects a fault tool, but also presents various tool states according to idle and active operation. The second, it's to represent the power spectrum of the sounds as images and apply some transformations on them in order to reveal, expose, and emphasize the health patterns that are hidden inside them. Finally, the contrast-enhanced PSD image obtained is diagnosed by using CNN. The results of the experiments demonstrate the high discrimination potential afforded by the proposed sound PSD image + CNN and show high diagnostic results according to the tool status.

Basic Research of Robot Arm Bending Angle Measuring System Using by PSD Sensor (PSD센서를 이용한 로봇팔 굽힘각 측정 시스템 기초 연구)

  • Goh, Bong-Jun;Kim, Ji-Sun;Oh, Han-Byeol;Kim, A-Hee;Kim, Jun-Sik;Lee, Eun-Suk;Baek, Jin-Young;Jun, Jae-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1409-1410
    • /
    • 2015
  • 현대기술의 발달로 인해 인간의 삶 중 많은 부분을 기계가 차지하고 있다. 특히 로봇공학 분야는 위험하거나 혹은 매우 정밀함을 요하는 일, 단순반복 등 인간이 기피하거나 하기 어려운 일을 대신 해줌으로서 많은 관심을 받고 있다. 이에 우리는 우리 생활에 가장 깊숙히 들어와 있는 로봇팔분야에 대해 말하고자 한다. 현재 로봇팔은 산업용은 물론, 의료용, 재해용 등 다양한 분야에서 사용되고 있다. 하지만 매우 정밀하고 정확한 작업을 위해 만들어져 있음에도 불구하고, 약간의 충격에도 이상이 생긴다거나, 기기의 이음세 부분의 잦은 회전으로 마모가 발생하게 되고 그에 따라 미세한 오차가 발생한다. 그런 상황을 방지하고자, 우리는 PSD(Position Sensitive Detecter)센서를 이용해 실시간으로 굽힘각을 측정 및 감시하여 보다 정확한 구동을 유도하려 한다. 이는 단순한 로봇팔만이 아닌 휴머노이드나 다른 회전을 이용하는 기기라면 어디든 쉽게 적용 할 수 있을 것이다.

  • PDF

A comparison of the characteristics of External type UHF partial discharge sensor for metal covered barriers in GIS (GIS 스페이서의 에폭시 주입구 장착형 UHF PD 센서의 성능 비교)

  • Hwang, Chul-Min;Kim, Young-No;Lee, Young-Sang;Kwak, Joo-Sik;Park, Ki-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2265-2267
    • /
    • 2005
  • We present detailed studies of externally applicable UHF PD sensors for a metal covered epoxy barrier with a small opening of epoxy injection-hole. The sensors were attached at the surface of injection hole of a metal covered epoxy barrier. 3-Dimensional electro magnetic simulations were performed to analyze electric-field distribution of the GIS and epoxy barrier with injection hole. Sensor structures were designed and analyzed using the 3-D EM simulator then fabricated for experimental verification. Sensor performance was measured in terms of spectral response and detected peak power. Real scale GIS and epoxy barriers were used to test and measure various aspect of performance of the sensors.

  • PDF

A Fine Manipulator with Compliance for Wafer Probing System (컴플라이언스를 갖는 웨이퍼 탐침 시스템용 미동 매니퓰레이터)

  • Choi, Kee-Bong;Kim, Soo-Hyun;Kwak, Yoon Keun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.9
    • /
    • pp.68-79
    • /
    • 1997
  • A six DOF fine manipulator based on magnetic levitation is developed. Since most of magnetic levitation system are inherently unstable, a proposed magnetically levitated fine manipulator is implemented by use of an antagonistic structure to increase stability. From mathematical modeling and experiment, the equations of motion are derived. In addition, a six DOF sensing system is implemented by use of three 2-axis PSD sensors. A model reference-$H_{\infty}$ controller is applied to the system for the position control, In application of the fine manipulator, a wafer probing system is proposed to identify nonfunctional circuts. The probing system requires compliance to avoid destruction of DUT(device under test). A feedfor- ward-PD controllers are presented by the terms of the position accuracy, the settling time and the force accuracy.y.

  • PDF

Development of an Intelligent Spacer Built in the Internal type UHF Partial Discharge Sensor (초고주파 광대역 부분방전 센서를 내장한 지능형 스페이서 개발)

  • Kim, Dong-Suk;Hwang, Chul-Min;Kim, Young-Noh;Choi, Jae-Ok;Seo, Wang-Byuk;Han, Bong-Soo;Choi, Soo-Hyun;Jang, Yong-Mu
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1378-1379
    • /
    • 2008
  • In this study, we developed intelligent spacer built in the internal type UHF PD sensors. 3-Dimensional electro-magnetic simulations were performed to analyze electric-field distribution of the single-phase GIS and three-phase GIS. After considering the spacer's specification, Sensor structures were designed and analyzed using the 3-D EM Simulator. As a result of the simulation the internal type UHF PD sensors were built in. Performance of the sensor built into real scale GIS spacer was measured in terms of return loss and detected Max voltage. And we identified a character of the intelligent spacer by using 5pC partial discharge cell.

  • PDF

Implementation of a Fluxgate Sensor using Ferrite Ring Core (페라이트 링 코어를 사용한 fluxgate 센서의 구현)

  • Park, Yong-Woo;Kim, Ki-Uk;Kim, Nam-Ho;Ryu, Ji-Goo
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.6
    • /
    • pp.427-433
    • /
    • 1999
  • In this paper, we have presented an one-axis fluxgate magnetic sensor with ferrite core, excitation, and pick-up coil. This magnetometer is consist of a sensing element, driving circuits for excitation coil and signal processing for detecting second harmonic frequency component which is proportional to the DC magnetic to be measured. The sensor core is excited by a square waveform of voltage through 82 turns of the excitation coil. The second harmonic output of pick-up coil(150 turns) is measured by a FFT spectrum analyzer. This result is compared to output of PSD(phase sensitive detector) unit for detecting a second harmonic component. The measured sensitivity is about 50 V/T at driving frequency of 2 kHz. The nonlinearity of fluxgate magnetic sensor is calculated about 2.0%.

  • PDF

Comparison of the characteristics related to the structure of external-type UHF UWB PD sensors for GIS (GIS용 외장형 광대역 극초단파 부분방전 센서의 구조에 따른 특성 비교)

  • Hwang, Chul-Min;Koo, Ja-Yoon;Park, Ki-Jun;Koo, Sun-Geun;Yoon, Jin-Yul;Lee, Young-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1769-1771
    • /
    • 2004
  • 가스절연 개폐장치(GIS)용 극초단파 부분 방전 측정장치에 다양하게 사용 할 수 있는 외장형 부분 방전 (PD) 센서를 제작하였다. Fat-dipole, 대수주기(log-periodic), spiral 및 log-spiral 형 패치안테나를 이용한 외장형 PD 센서의 주파수 특성과 검출감도를 기본 Dipole형 센서와 비교하였다. 제작된 센서는 170kV 단상 GIS의 스페이서에 장착하여 5 pC PD에 대한 각 센서의 주파수 특성과 감도를 측정 하였다.

  • PDF