• Title/Summary/Keyword: PR(Performance ratio)

Search Result 52, Processing Time 0.027 seconds

PAPR reduction and Pre-distortion techniques against Non-linear Distortion of Satellite WiBro

  • Shrestha, Robin;Seo, Myung-Hwan;Go, Gyeong-Wan;Lee, Byung-Seub
    • Journal of Satellite, Information and Communications
    • /
    • v.3 no.2
    • /
    • pp.18-25
    • /
    • 2008
  • A major drawback of Orthogonal Frequency Division Multiplexing (OFDM) system is high peak-to-average power ratio (PAPR) of the transmitted signal which introduces inevitable non-linear distortion in the transmission due to the amplifier non-linear property. This causes both in-band distortion and out of band spectrum re-growth. A polynomial based pre-distortion is estimated using the non-linear and inverse non-linear polynomial achieved through the Least Square Error (LSE) method. A new technique of PAPR reduction called 'Phase Realignment' (PR) is proposed which has a optimal effect in improving the BER performance as well as considerable reduction in the PAPR. In this paper we used the PR method along with the 'Peak Clipping' (PC) method is used before the pre-distortion to remove the high peak present in the non constant amplitude of the OFDM signal responsible to drive the amplifier in near saturation region for better performance of the system.

  • PDF

PREPREG 제작 방식에 의한 압력용기(STEB)의 시험 및 고찰

  • 이원복;손원경;유광호
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.30-30
    • /
    • 1997
  • 국내에서는 시도되지 않았던 조립식 맨드렐 및 prepreg 제작 방식을 적용하여 filament winding machine으로 압력 용기(STEB)를 제작, 음향 방출 측정 장비 및 strain gage 등을 부착한 수압 시험으로 압력용기의 구조적 건전성 예측 및 파열 압력을 측정하여 성능을 분석하였다. 동일한 winding pattern 및 조건하에 prepreg winding과 wet winding 방식을 적용하여 제작한 압력 용기의 성능을 비교하였고, prepreg winding의 설계 조건, 공정 변화를 통해 제작한 압력 용기의 파열 압력 및 형태를 분석하였다. 이러한 winding 조건들에 따라 제작된 압력용기는 최종적으로 PR(Performance ratio) 값을 산출하고, 이를 통하여 prepreg 제작 방식의 장단점, 제작에 필요한 설계 조건 및 기초 자료 등을 고찰하여 보았다.

  • PDF

A Channel Assignment Scheme Using Power Allocation Concept for CDMA Cellular System (CDMA 셀룰러 시스템에서 전력할당개념을 이용한 채널할당기법)

  • Lee, Dong-Myung;Jun, Moon-Seog
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.3
    • /
    • pp.692-698
    • /
    • 1999
  • In this paper, we proposed the channel assignment scheme for the CDMA(Code Division Multiple Access) cellular system using power allocation concept. Also, the performance of the proposed scheme was analyzed and it was compared with the channel assignment scheme using the fixed power allocation method in the CDMA cellular system. The proposed scheme allocates the power adaptively in according to the traffic loads and the traffic distribution pattern of neighbor cells in the forward link. We found that total call blocking probability (Pr) is more dependent on blocking probability($P_B$) than outage probability (Po) under physical number of channels ($C_{th}$)=30. Pr(Call Blocking Probability) is dependent on $P_B$(Blocking Probability) and Po(Outage Probability) at the same ratio under $C_{th}$=32, in which case P$P_{TA}$(blocking probability for the adaptive power allocation) is greater than $P_{TF}$(blocking probability for the fixed power allocation) about 6%.

  • PDF

Performance Ratio of Crystalline Si and Triple Junction a-Si Thin Film Photovoltaic Modules for the Application to BIPVs

  • Cha, Hae-Lim;Ko, Jae-Woo;Lim, Jong-Rok;Kim, David-Kwangsoon;Ahn, Hyung-Keun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.1
    • /
    • pp.30-34
    • /
    • 2017
  • The building integrated photovoltaic system (BIPV) attracts attention with regard to the future of the photovoltaic (PV) industry. It is because one of the promising national and civilian projects in the country. Since land area is limited, there is considerable interest in BIPV systems with a variety of angles and shapes of PV panels. It is therefore expected to be one of the major fields for the PV industry in the future. Since the irradiation is different from each installation angle, the output can be predicted by the angles. This is critical for a PV system to be operated at maximum power and use an efficient design. The development characteristics of tilted angles based on data results obtained via long-term monitoring need to be analyzed. The ratio of the theoretically available and actual outputs is compared with the installation angles of each PV module to provide a suitable PV system for the user.

A Study on Relationship Between Violation of Environmental Regulations and Firm's Characteristics (기업특성과 환경규제 위반의 관계 연구)

  • Kim, In-Su
    • Management & Information Systems Review
    • /
    • v.31 no.4
    • /
    • pp.33-56
    • /
    • 2012
  • The purposes of this paper are analysed the relationship between environmental regulation and financial performance in Korea. The financial performance of listed companies and Outside Auditing firms was evaluated by logistic regression. First, R&D investment is proportionally correlated with the ability to comply with environmental regulations. It can be explained increase of investment in R&D causes enhancement of compliance of environmental regulations with development of environmental technology. Second, statistical significance is not observed between financial aspects such as current ratio, debt-to-equity ratio, cash flow, and operating profit margin and the ability to comply with environmental regulations. It indicates high financial performance could not directly lead investment for the ability of that. Third, in terms of structural aspects, firm size and employees have a reliable correlation with compliance with environmental regulations due to high attention of larger firms for PR, and IR, while capital intensity and gravity, and exports do not. Finally, violation of environmental regulations is not affect by the controlling shareholder ownership.

  • PDF

Analysis of Performance of Balcony Integrated PV System (발코니 일체형 태양광발전시스템의 발전성능 분석)

  • Kim, Hyun-Il;Kang, Gi-Hwan;Park, Kyung-Eun;So, Jung-Hoon;Yu, Gwon-Jong;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.1
    • /
    • pp.32-37
    • /
    • 2009
  • Photovoltaic(PV) permits the on-site production of electricity without concern for fuel supply or environmental adverse effects. The electrical power is produced without noise and little depletion of resources. So BIPV(Building-Integrated Photovoltaic) system have been increased around the world. Hereby the relative installation costs of the system will be relatively low compared to traditional installations of PV in high-rise buildings. This paper examined possibility of building integrated balcony PV system and analyzed both performance and problems of this system. The system is influenced by conditions such as irradiation, module temperature, shade and architectural component etc. If this BIPV system of 1.1kW is possible the natural ventilation in the summer case, the temperature of PV module decrease and then the efficiency of PV system increase generally. By the results, the annual averaged PR of BIPV system of cold facade type is about 74.7%.

Performance Analysis of Complex Phase-code for Phase Multiplexes Holographic Memory System (위상 다중화 홀로그래픽 메모리 시스템을 위한 CPC 위상코드의 성능 분석)

  • 조병철;김정진;김은수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.1C
    • /
    • pp.1-8
    • /
    • 2003
  • In this paper, performance of the CPC(complex phase code) which is recently proposed as a practical phase encoding method for phase-code multiplexes holographic memory system is comparatively analyzed with those of the conventional phase codes such as PR(pure random code), RCE(random code with equality), WHM(Walsh Hadamard Matrix). In computer simulation, the size of an address bean is fixed at 32$\times$32 pixels and 0%-25% phase-error ratio in a pixel are intentionally added to the real phase values to consider the nonlinear phase-modulation characteristics of the practical spatial light modulator. From comparative analysis of crosstalks and signal-to-noise ratios for these phase codes by calculating auto-correlation and cross-correlation, it is found that the CPC have the lowest cross-correlation mean value of 0.021, the lowest standard deviation of 0.0113 and the highest signal-to-noise ratio(SNR) of 27.4 among the four types of phase code. In addition, from the calculation of the number of all possible address beams for these four types of phase code as the size of the address beam is fixed to 3232 pixels, the CPC is found to have 6.334$\times$10$^{49}$ address beams, which are relatively higher number than that of the conventional phase codes.

Co-Channel Interference Cancellation in Cellular OFDM Networks - PART I : Maximum-Likelihood Co-Channel Interference Cancellation with Power Control for Cellular OFDM Networks

  • Mohaisen, Manar;Chang, Kyung-Hi
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.5A
    • /
    • pp.409-416
    • /
    • 2007
  • In cellular orthogonal frequency division multiplexing (OFDM) networks, co-channel interference (CCI) leads to severe degradation in the BER performance. To solve this problem, maximum-likelihood estimation (MLE) CCI cancellation scheme has been proposed in the literature. MLE CCI cancellation scheme generates weighted replicas of the transmitted signals where weights represent the estimated channel transfer functions. The replica with the smallest Euclidean distance from the received signal is selected and data are detected. When the received power of the desired and interference signals are nearly the same, the BER performance is degraded. In this paper, we propose a closed-loop power control (PC) scheme capable of detecting the equal received power situation at the mobile station (MS) receiver by using the newly introduced parameter power ratio (PR). When this situation is detected, the MS sends a feedback to the desired base station (BS) which boosts the transmission power in the next frame. At cell edge where signal to interferer ratio (SIR) is considered to have average value between -5 dB and 10 dB, computer simulations show that the proposed CCI cancellation scheme has a gain of 7 dB at 28 Km/h.

An Adaptive Data Compression Algorithm for Video Data (사진데이타를 위한 한 Adaptive Data Compression 방법)

  • 김재균
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.12 no.2
    • /
    • pp.1-10
    • /
    • 1975
  • This paper presents an adaptive data compression algorithm for video data. The coling complexity due to the high correlation in the given data sequence is alleviated by coding the difference data, sequence rather than the data sequence itself. The adaptation to the nonstationary statistics of the data is confined within a code set, which consists of two constant length cades and six modified Shannon.Fano codes. lt is assumed that the probability distributions of tile difference data sequence and of the data entropy are Laplacian and Gaussion, respectively. The adaptive coding performance is compared for two code selection criteria: entropy and $P_r$[difference value=0]=$P_0$. It is shown that data compression ratio 2 : 1 is achievable with the adaptive coding. The gain by the adaptive coding over the fixed coding is shown to be about 10% in compression ratio and 15% in code efficiency. In addition, $P_0$ is found to he not only a convenient criterion for code selection, but also such efficient a parameter as to perform almost like entropy.

  • PDF

A Study on Performance Analysis of 3kW Grid-Connected PV Systems (3kW급 계통연계형 태양광발전시스템의 성능특성 비교분석에 관한 연구)

  • So, Jung-Hun;Choi, Ju-Yeop;Yu, Gwon-Jong;Jung, Young-Seok;Choi, Jae-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.2
    • /
    • pp.9-15
    • /
    • 2004
  • 3kW grid connected PV(photovoltaic) systems have been constructed for evaluating and analyzing performance of PV system at FDTC(field demonstration test center) in Korea, PV systems installed in FDTC have been operating and monitored since November 2002. As climatic and irradiation conditions have been varied through long-term field test, data acquisition system has been constructed for measuring performance of PV system to observe the overall effect of environmental conditions on their operation characteristics. The performance of PV systems has been evaluated and analyzed for component perspective(PV array and power conditioning system) and global perspective(system efficiency, capacity factor, and electrical power energy) by field test. By the results, it is very important to develop optimal design technology of grid connected PV system.