• Title/Summary/Keyword: PPM model

Search Result 343, Processing Time 0.025 seconds

Modifying Effect of Diallyl Sulfide on Colon Carcinogenesis in C57BL/6J-ApcMin/+ Mice

  • Kang, Jin-Seok;Kim, Tae-Myoung;Shim, Tae-Jin;Salim, Elsayed I.;Han, Beom-Seok;Kim, Dae-Joong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.4
    • /
    • pp.1115-1118
    • /
    • 2012
  • Diallyl sulfide (DAS), a flavoring compound derived from garlic, is considered to have cancer chemopreventive potential in experimental animals and humans. This study was designated to examine possible chemopreventive effects of DAS on colon carcinogenesis using genetically engineered transgenic $Apc^{Min/+}$ mice, a well-established animal model for familial adenomatous polyposis (FAP) and sporadic colorectal cancer. Male C57BL/6J-$Apc^{Min/+}$ mice were divided into three groups. Animals of group 1 were placed on the basal diet (AIN-76A) as non-treated controls. Animals of groups 2 and 3 were given DAS-containing diets (in doses of 100 and 300 ppm, respectively). All mice were sacrificed at the end of week 10 of the experiment. Histopathological investigation revealed that the incidence of colonic polyps was decreased dose-dependently by 19% (13/16) in group 2 and by 32% (13/20) in group 3 compared to the 100% incidence (10/10) in group 1. The multiplicity of colonic polyps per mouse was also slightly decreased by DAS treatment ($1.88{\pm}0.35$ in group 2 and $1.63{\pm}0.36$ in group 3) compared to $2.00{\pm}0.39$ in group 1. On the other hand, there were no significant differences in the numbers of total polyps per mouse in the small intestine between the groups. Taken together, we suggest that DAS may exert promising inhibitory effects on colon carcinogenesis in the transgenic $Apc^{Min/+}$ mice.

Optimization of Operating Condition on Gasification of Ash-free Coal by Using the Sensitivity Analysis of ASPEN Plus (민감도 해석을 통한 무회분 석탄의 가스화 최적 운전조건 도출)

  • Park, Sung-Ho;Jeon, Dong-Hwan;Yun, Sung-Phil;Chung, Seok-Woo;Choi, Ho-Kyung;Lee, Si-Hyun
    • Clean Technology
    • /
    • v.20 no.3
    • /
    • pp.298-305
    • /
    • 2014
  • Ash included in coal can cause environmental pollution and it can decrease efficiency of mass and heat transfer by getting scorched and stick in the facilities operated at high temperature. To solve this problem, a feasibility study on pulverized coal fired power plant and integrated gasification combined cycle (IGCC) using the AFC (Ash-Free Coal) as well as the development to remove the ash from the coal was conducted. In this research, optimization of operating condition was proposed by using sensitivity analysis of ASPEN $Plus^{(R)}$ to apply the coal containing under the 200 ppm ash for integrated gasification combined cycle. Particularly, the coal gasification process was classified as three parts : pyrolysis process, volatile matter combustion process and char gasification process. The dimension and operating condition of 1.5 ton/day class non-slagging gasifier are reflected in the coal gasification process model.

The Characteristics and Implementations of Quality Metrics for Analyzing Innovation Effects in Six Sigma Projects (식스시그마 프로젝트 사례에서 혁신효과 분석을 위한 품질척도의 특성 및 적용)

  • Choi, Sungwoon
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.1
    • /
    • pp.169-176
    • /
    • 2014
  • This research discusses the characteristics and the implementation strategies for two types of quality metrics to analyze innovation effects in six sigma projects: fixed specification type and moving specification type. $Z_{st}$, $P_{pk}$ are quality metrics of fixed specification type that are influenced by predetermined specification. In contrast, the quality metrics of moving specification type such as Strictly Standardized Mean Difference(SSMD), Z-Score, F-Statistic and t-Statistic are independent from predetermined specification. $Z_{st}$ sigma level obtains defective rates of Parts Per Million(PPM) and Defects Per Million Opportunities(DPMO). However, the defective rates between different industrial sectors are incomparable due to their own technological inherence. In order to explore relative method to compare defective rates between different industrial sectors, the ratio of specification and natural tolerance called, $P_{pk}$, is used. The drawback of this $P_{pk}$ metric is that it is highly dependent on the specification. The metrics of F-Statistic and t-Statistic identify innovation effect by comparing before-and-after of accuracy and precision. These statistics are not affected by specification, but affected by type of statistical distribution models and sample size. Hence, statistical significance determined by above two statistics cannot give a same conclusion as practical significance. In conclusion, SSMD and Z-Score are the best quality metrics that are uninfluenced by fixed specification, theoretical distribution model and arbitrary sample size. Those metrics also identify the innovation effects for before-and-after of accuracy and precision. It is beneficial to use SSMD and Z-Score methods along with popular methods of $Z_{st}$ sigma level and $P_{pk}$ that are commonly employed in six sigma projects. The case studies from national six sigma contest from 2011 to 2012 are proposed and analyzed to provide the guidelines for the usage of quality metrics for quality practitioners.

Performance of pilot-based signal detection for digital IoT doorlock system (디지털 도어락 시스템을 위한 파일럿 기반 신호검출 성능)

  • Lee, Sun Yui;Hwang, Yu Min;Sun, Young Ghyu;Yoon, Sung Hoon;Kim, Jin Young
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.723-728
    • /
    • 2018
  • This paper proposes a signal detection method for IoT door lock system which is a new application field of VLC (Visible Light Communication). This paper describes the signal detection technique for user recognition that needs to be overcome in order to apply VLC to door lock system which has a demand for new technology due to security issue. This system has security and high signal detection characteristics because it uses existing infrastructure to communicate with visible light. In order to detect the signal using FFT, the signal of the user who accesses the authentication channel based on the pilot signal is detected, and the performance of the false alarm probability and detection probability is shown in the channel model.

Chemopreventive effects of garlic and mugwort mixture extract on Helicobacter pylori-associated mouse gastric carcinogenesis

  • Youm, So-Young;Kim, Tae-Wang;Shin, Sang Kyung;Jeong, Heon Sang;Kang, Jong-Koo;Kim, Tae Myoung;Kim, Kil Ho;Ahn, Byeongwoo
    • Korean Journal of Veterinary Research
    • /
    • v.54 no.3
    • /
    • pp.171-177
    • /
    • 2014
  • Garlic and mugwort have long been used in traditional medicine to prevent various diseases. Several in vitro studies have reported protective efficacies of garlic and mugwort in cases of gastric cancer. In the present study, we investigated the cancer preventive effects of garlic and mugwort mixture extract (GME) in a Helicobacter (H.) pylori-associated gastric carcinogenesis mouse model. To induce gastric cancer, C57BL/6 mice were treated with N-methyl-N-nitrosourea and H. pylori. Various concentrations of GME (0, 100, 500, and 1,000 ppm) were then fed to the mice for 38 weeks, after which the tumor tissues were examined for histopathology, mucin histochemistry and ${\beta}$-catenin. The incidence of gastric tumors was significantly lower in the highest dose GME-treated mice (46.7%) than control mice (85.7%) (p < 0.05). The multiplicity and size of tumors were also significantly reduced by GME feeding in a dose-dependent manner (p < 0.01). Furthermore, GME suppressed the H. pylori-associated chronic inflammation measured by histologic grading of H. pylori density, chronic gastritis, glandular atrophy and intestinal metaplasia in non-tumorous gastric mucosae. Our data suggest that GME suppresses gastric tumorigenesis via suppression of H. pylori-associated chronic inflammation.

Membrane Permeation Characteristics and Fouling Control through the Coating of Poly(vinyl alcohol) on PVDF Membrane Surface (PVDF막 표면에 폴리비닐알코올 코팅을 통한 분리막의 투과특성 및 막오염 제어)

  • Jang, Hanna;Kim, In-Chul;Lee, Yongtaek
    • Membrane Journal
    • /
    • v.24 no.4
    • /
    • pp.276-284
    • /
    • 2014
  • In this study, a hydrophobic polyvinylidene fluoride (PVDF) membrane was modified by coating neutral hydrophilic poly(vinyl alcohol). The flux of pure water was measured and then fouling test was conducted with bovin serum albumin (BSA) as model protein foulant. As a result, the experiments showed that pure water flux was decreased but anti-fouling property was significantly enhanced. Pure water flux with increasing molecular weights of the polymer was decreased and fouling resistance was enhanced. Also, Pure water flux with increasing solution concentration was decreased and fouling resistance was enhanced. It is probably due to the increase in hydrophilicity and decrease in roughness of the membrane surface, as revealed by contact angle and AFM analysis.

Surfactant Aided Air-sparging for Groundwater Remediation (계면촬성제 첨가에 따른 지하수 폭기법의 폭기효율 변화 연구)

  • 소효은;최경민;이승재;김헌기
    • Economic and Environmental Geology
    • /
    • v.35 no.5
    • /
    • pp.421-428
    • /
    • 2002
  • Lab-scale experiments were conducted to evaluate the effect of surface tension reduction on the extension of the influence zone and the VOC removal efficiency of ground water sparging. A glass column packed with coarse sand was used for VOC removal test at two different surface tensions. A glass column without porous media was also used fer control purpose prior to sand-packed column test. A quasi-two-dimensional glass box model, packed with a sand, was used fer sparging zone tests at different water surface tensions. Surface tension of the aquoues solution used in this study was controlled using sodium dodecyl sulfate (SDS). For the glass, sand column experiments, total amount of air filled in the media increased as surface tension decreased. Toluene (used as VOC in this study) removal rate increased slightly with decreased surface tension f3r both free water column and sand-packed column. Air sparging zone extended up to 500% as the surface tension decreased. Combining the results from two different experiments, VOC removal efficiency is expected to increase significantly with surface tension reduction.

The Chemopreventive Effect of Sodium Selenite on Colon Carcinogenesis in Medium-Term Multi-Organ Bioassay (다장기 중기발암성 시험법을 이용한 셀렌염의 대장암 억제효과에 대한 연구)

  • Han, Beom-Seok;Hong, Choong-Man;Shin, Dong-Hwan;Lee, Kook-Kyung;Ahn, Byeong-Woo;Jang, Dong-Deuk
    • Korean Journal of Veterinary Pathology
    • /
    • v.5 no.1
    • /
    • pp.23-28
    • /
    • 2001
  • This study was conducted to assess the chemopreventive effects of sodium selenite in the rat medium-term multi-organ bioassay using a DMBDD model (DEN+MNU+BBN+DMH+DHPN). Seventy five,6-week-old, male SD rats were divided into 3 groups. The animals in group 1 received DEN(diethylnitrosamine,100 mg/kg bw, single i.p., in saline), MNU (N-methyl-nitrosourea,20 mg/kg bw, i.p.,4 times for 2 weeks), BBN (N-butyl-N-(4-hydroxybutyl) nitrosamine, 0.2% in drinking water for 2 weeks), DMH (1,2-dimethylhydrazine, 40 mg/kg bw, s.c., in saline.4 times (or 2 weeds), and DHPN (N-bis(2-hydroxy-pro-pal)nitrosamine,0.1% in drinking water for 2 weeks), then were placed on sodium selenite (4 ppm in drinking water) for 22 weeks from weeks 4 to 26. The animals in group 2 were given DMBDD alone. The animals in group 3 were given sodium selenite alone. Animals were sacrificed at week 12 for ACF quantitative analysis and at week 26 for tumor induction. The body weights in the group 1 were significantly decreased compared with those of group 2. The tumor multiplicities of large intestine in the group 1 were significantly decreased compared with those of group 2 (P<0.05). These results indicate that sodium selenite may have a potential as chemopreventive agents of colon carcinogenesis.

  • PDF

Studies on the Fouling Reduction through Oxyfluorination of Porous Polyethylene Membranes (함산소불소화법을 통한 다공성 폴리에틸렌막의 파울링현상 감소연구)

  • Kang, Su Yeon;Rhim, Ji Won;Cheong, Seong Ihl
    • Membrane Journal
    • /
    • v.24 no.6
    • /
    • pp.431-437
    • /
    • 2014
  • To overcome the flux reduction due to the fouling by adsorption of foulants onto the porous hydrophobic polyethylene membrane surface, the oxyflorination was introduced to hydrophilize the hydrophobic membranes. After the hydrophilization through oxyfluorination, the contact angle decreased from $93^{\circ}$ to $50^{\circ}$ while the water flux increased to 60%. It was considered that for the model foulants dissolved in water, such as albumin (form bovine serum, BSA), humic acid sodium salt (HA), and alginic acid sodium salt (SA), the flux was enhanced since the adsorbed foulants decreased by the oxyfluorination. Particularly, it was obtained that the water flux was over twice more than the untreated polyethylene membrane in case of SA foulant.

Study on the Relationship between Indoor $CO_2$ Concentration and Local Mean Air-age in the Lecture Room with System Air-conditioner and Ventilation Unit for Cooling Loads (냉방시 시스템에어컨과 환기유닛 적응 강의실에서 실내 $CO_2$ 농도와 국소평균공기연령 연구)

  • Jang Jae-Soo;Noh Kwang-Chul;Oh Myung-Do
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.8
    • /
    • pp.736-745
    • /
    • 2005
  • This study is undertaken to evaluate the relationship between the indoor $CO_2$ concentration and the local mean air-age in the lecture room with the occupants. We conducted the experiments to examine the indoor $CO_2$ concentration and the local mean air-age with respect to the supply airflow of the ventilation system and the discharge angle and air-flow of the system air conditioner. Through the experiments, we found out that indoor $CO_2$ concentrations calculated by the prediction equation of Seidel are about 350 ppm lower than those measured by the experiments. The indoor $CO_2$ concentration is not related with the air-flow and the discharge angle of the system air-conditioner, but with the ventilation airflow. From the numerical calculation, the indoor $CO_2$ concentration is not related with the ventilation effectiveness, but strongly with the local mean air-age. In case of our model, the indoor $CO_2$ concentration is likely to fall within the acceptable air quality when the local mean air-age is averagely predicted under 400 seconds.