• Title/Summary/Keyword: PMW

Search Result 61, Processing Time 0.026 seconds

A Miniaturized and Band Rejection Characteristic of Bow-Tie Monopole UWB Antenna (보우-타이 모노폴 UWB 안테나의 소형화 및 대역 저지 특성)

  • Choi, Hyung-Seok;Choi, Kyoung;Hwang, Hee-Yong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.3
    • /
    • pp.300-305
    • /
    • 2012
  • In this paper, a miniaturized bow-tie monopole UWB antenna with band rejection characteristic is proposed. To miniaturize the proposed antenna, a perfect magnetic wall(PMW) condition is applied to primitive bow-tie monopole antenna. An uneven ground patch, a tapered feeding structure and a edge-chopped main patch are adapted for impedance matching. A quater-lambda slot resonator is inserted at main patch to prevent interference in UWB band from another band. The proposed antenna is fabricated on Taconic RF60-A substrate with relative permittivity of 6.15. The size of the proposed antenna is $30.0{\times}39.7mm^2$, which is only 45 % of the conventional bow-tie monopole antenna. The proposed antenna covers full UWB band with return losses less than -10 dB and has band stop characteristic in 5 GHz WLAN band. The maximum gains are within -1.0~5.0 dBi, the group delay variations are within 1.0 ns and the radiation patterns show directivity characteristics in x-y plane.

Improved Full Wave Mode ZVT PWM DC-DC Converters (개선된 전파형 ZVT PWM DC-DC 컨버터)

  • 김태우;김학성
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.1
    • /
    • pp.10-16
    • /
    • 2004
  • In this thesis, improved full wave mode ZVT(Zero-Voltage-Transition) PMW DC-DC Converters are presented to maximize the regeneration ratio of resonant energy by only putting an additional diode In series with the auxiliary switch. The operation of the auxiliary switch in a half wave mode makes it possible soft switching operation of all switches including the auxiliary switch whereas it is turned off with hard switching in conventional converter. The increase of the regeneration ratio to resonant energy results in low commutation losses and minimum voltage and current stresses. The operation principles of the improved ZVT PWM DC-DC Converters are theoretically analyzed using the boost converter topology as an example. Both theoretical analysis and experimental results verify the validity of the PWM boost converter topology with the improved full wave mode ZVT PWM converters.

Effect of Excess MgO on Dielectric and Electrostrictive Properties of $0.99Pb(Mg_{1/3}Nb_{2/3})O_3-0.01Pb(Mn_{2/3}W_{1/3})O_3$ ($0.99Pb(Mg_{1/3}Nb_{2/3})O_3-0.01Pb(Mn_{2/3}W_{1/3})O_3$계의 유전 및 전왜 특성에 미치는 과잉 MgO의 영향)

  • 윤기현;김승연;남윤우;조용수;강동헌
    • Journal of the Korean Ceramic Society
    • /
    • v.30 no.8
    • /
    • pp.629-634
    • /
    • 1993
  • Dielectric and electrostrictive properties of 0.99Pb(Mg1/3Nb2/3)O3-0.01Pb(Mn2/3W1/3)O3 system using KCl-NaCl salts have been investigated as a function of the amount of excess MgO. For the specimens calcined at $700^{\circ}C$ for 1h and then sintered at 115$0^{\circ}C$ for 4h, the perovskite phase and the relative density were about 98% and 95%, respectively. With the addition of excess MgO up to 10mol%, the dielectric constant and the electrostrictive strain increased due to the increase of density and grain size, and these properties were degraded by the further addition of excess MgO. For the 10mol% excess MgO added specimen, the maximum electrostrictive strain, Xmax, and the electrostrictive coefficient, Q11, were 4.5$\times$10-4, 3.5$\times$10-2m4/C2, respectively. These results were correlated with the property of PMW and microstructure.

  • PDF

Control of Electromagnetic Accelermeter with Digital PWM Technique (서오보형 가속도계의 PMW 제어)

  • Kim, Jung-Han;Oh, Jun-Ho;Che, Woo-Seong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.8
    • /
    • pp.112-119
    • /
    • 1996
  • Among the various type of accelerometer, the servo rebalancing type accelermoter can be suitable for Inertial Navigation System, because of its high sensitivity and good response in low frequency. In this paper, we proposed a new technology to control inductive tuype accelerometer utilizing digital PWM method. The new developed digital PWM control has special design scheme for transmitting measurement value to outer device in its servo ollp. So it has no quantized error of transforming outputs of sensors to digital domain. The quantized error may make serious problem in INS system, because outputs of sensor are integrated once or twice by digital computer and it happens every sensor reading times. Therefore, in order to get the accurate information such as displacement, it is necessary to measure accurately the input current. In addition, Digital Signal Processing needs digital data transmission, digital PWM method is adaptive for this purpose. We realized a practical circuit for digital PWM control, analyzed the stability of the circuit, and designed the controller etc. In this study, we solved many practical problem for this application, and got out good results.

  • PDF

Big Data Management System for Biomedical Images to Improve Short-term and Long-term Storage

  • Qamar, Shamweel;Kim, Eun Sung;Park, Peom
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.15 no.2
    • /
    • pp.66-71
    • /
    • 2019
  • In digital pathology, an electronic system in the biomedical domain storage of the files is a big constrain and because all the analysis and annotation takes place at every user-end manually, it becomes even harder to manage the data that is being shared inside an enterprise. Therefore, we need such a storage system which is not only big enough to store all the data but also manage it and making communication of that data much easier without losing its true from. A virtual server setup is one of those techniques which can solve this issue. We set a main server which is the main storage for all the virtual machines(that are being used at user-end) and that main server is controlled through a hypervisor so that if we want to make changes in storage overall or the main server in itself, it could be reached remotely from anywhere by just using the server's IP address. The server in our case includes XML-RPC based API which are transmitted between computers using HTTP protocol. JAVA API connects to HTTP/HTTPS protocol through JAVA Runtime Environment and exists on top of other SDK web services for the productivity boost of the running application. To manage the server easily, we use Tkinter library to develop the GUI and pmw magawidgets library which is also utilized through Tkinter. For managing, monitoring and performing operations on virtual machines, we use Python binding to XML-RPC based API. After all these settings, we approach to make the system user friendly by making GUI of the main server. Using that GUI, user can perform administrative functions like restart, suspend or resume a virtual machine. They can also logon to the slave host of the pool in case of emergency and if needed, they can also filter virtual machine by the host. Network monitoring can be performed on multiple virtual machines at same time in order to detect any loss of network connectivity.

A New Overmodulation Strategy for PWM Inverter (PWM 인버터의 출력전압 향상을 위한 과변조 기법)

  • 김상훈
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.1
    • /
    • pp.13-18
    • /
    • 1999
  • This paper proposes a new overmodulation stategy to give a better voltage by the full utilization of the hexagon voltage range in the space vector PWM(SVPWM) inverter. This overmodulation strategy can apply to the vector control, leading to better output torque capability in the ac motor drive system. This strategy is that in the overmodulation range, the d-axis output current is given a priority to regulate the flux well, instead the q-axis output curent is sacrificed. Therefore, the vector control even in the overmodulation PWM operation can be achieved well. For this purpose, the d-axis output voltage of a current controller to control the flux is conserved. the q-axis output voltage to control the torque is controlled to place the reference voltage vector on the hexagon boundary in case of the overmodulation. The validity of the proposed overall scheme is confirmed by simulation and experiments for a 22[kW] induction motor drive system

Ultrasonic Sensor Controlled Sprayer for Variable Rate Liner Applications (초음파센서를 이용한 변량제어 스프레이어)

  • Jeon, Hong-Young;Zhu, Heping
    • Journal of Biosystems Engineering
    • /
    • v.36 no.1
    • /
    • pp.15-22
    • /
    • 2011
  • An experimental variable rate nursery sprayer was developed to adjust application rates for canopy volume in real time. The sprayer consisted of two vertical booms integrated with ultrasonic sensors, and variable rate nozzles coupled with pulse width modulation (PMW) based solenoid valves. A custom-designed microcontroller instructed the sensors to detect canopy size and occurrence and then controlled nozzles to achieve variable application rates. A spray delivery system, which consisted of diaphragm pump, pressure regulator and 4-cycle gasoline engine, offered the spray discharge function. Spray delay time, time adjustment in spray trigger for the leading distance of the sensor, was measured with a high-speed camera, and it was from 50 to 140 ms earlier than the desired time (398 ms) at 3.2 km/h under indoor conditions. Consequently, the sprayer triggered 4.5 to 12.5 cm prior to detected targets. Duty cycles of the sprayer were from 20 to 34 ms for senor-to-canopy (STC) distance from 0.30 to 0.76 m. Outdoor test confirmed that the nozzles were triggered from 290 to 380 ms after detecting tree canopy at 3.2 km/h. The spray rate of the new sprayer was 58.4 to 85.2% of the constant application rate (935 L/ha). Spray coverage was collected at four areas of evergreen canopy by water sensitive papers (WSP), and ranged from 1.9 to 41.1% and 1.8 to 34.7% for variable and constant rate applications, respectively. One WSP area had significant (P < 0.05) difference in mean spray coverage between two application conditions.

Design of the Robust Active Power Filter under the Unbalanced and Distorted Source Voltages in Three-phase Four-wire Systems (전원전압의 불평형 및 왜곡에 강인한 3상 4선식 전력용 능동 필터의 설계)

  • Min Joon-Ki;Kim HyoSung;Choi Jaeho;Kim Kyung-Hwan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.5
    • /
    • pp.420-429
    • /
    • 2004
  • This paper proposes a novel current control strategy on active power filters using PQR instantaneous power theory which can compensate the line current harmonics and the neutral line current under the unbalanced and/or distorted source conditions in three-phase four-wire systems. The characteristics of the inverter ac filters are analyzed and a novel digital controller are proposed to overcome the inherent time delay problem in digital controllers with designed control gain in this paper. The proposed current control method is based on a sinusoidal PWM for fully-digital implementation compared with a conventional hysteresis PWM. PSiM simulation results verify the good performance of the proposed current control strategy on shunt type APFs.

The Piezoelectic and electromechanical Characteristics of PZ-PT-PMWS (PZ-PT-PMWS의 압전 및 전기기계적 특성)

  • 홍종국;이종섭;채홍인;윤만순;정수현;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.403-406
    • /
    • 2000
  • The piezoelectric properties and the doping effect of N $b_2$ $O_{5}$ and Mn $O_2$for 0.95PbZ $r_{x}$ $Ti_{x}$ $O_3$+0.05Pb(M $n_{0.42}$ $W_{0.26}$S $b_{0.32}$) $O_3$ compositions have been investigated. In the composition of 0.95PbZ $r_{0.54}$ $Ti_{0.46}$ $O_3$+0.05Pb(M $n_{0.42}$ $W_{0.26}$S $b_{0.32}$) $O_3$the Values Of $k_{p}$ find and $\varepsilon$$_{33}$ $^{T}$ are maximized, but $Q_{m}$ Was minimized ( $k_{p}$ =0.51, $Q_{m}$ =1750). The grain size was suppressed and the uniformity of grain was improved with doping concentration of N $b_2$ $O_{5}$ for 0.95PbZ $r_{0.54}$ $Ti_{0.46}$ $O_3$+0.005Pb(M $n_{0.42}$ $W_{0.26}$S $b_{0.32}$) $O_3$sample. The values of $k_{p}$ increased and the values of $Q_{m}$ slightly decreased when 0.5 wt% of N $b_2$ $O_{5}$ is doped. And the values of $k_{p}$ was the same formation of the N $b_2$ $O_{5}$ dopant when 0.5 wt% of M $n_2$ $O_{5}$ is doped. But the values of $Q_{m}$ was deeply decreased when 0.5 wt% of Mn $O_2$is doped. As a experiment results under high electric field driving, this piezoelectric ceramics are very stable. Conclusively, piezoelectric ceramic compsiton investigated at this paper is suitable for application to high power piezoelectric devices.. devices..ices.. devices..

  • PDF

Efficacy of $M+\;Parapac^{(R)}$ on protection against PMWS with $Gl{\ddot{a}}sser's$ disease (국내 양돈장에서 돼지글래셔병을 동반한 PMWS에 대한 M+ $Parapac^{(R)}$의 방어효과)

  • Ahn, Na-Kyoung;Seo, Tae-Won;Jeong, Hyun-Kyu;Yoon, Byung-Il;Han, Jeong-Hee
    • Korean Journal of Veterinary Service
    • /
    • v.31 no.3
    • /
    • pp.347-356
    • /
    • 2008
  • The purpose of this study was to evaluate the efficacy and cross-protection of serovar 12 against serovar 4 or 5 of H parasuis with M+$Parapac^{(R)}$. A total of 141 piglets from 2(A and B) farms were used and divided into experimental group and control group in each farm. Farm A has been detected H parasuis serovar 12, whereas farm B has been detected H parasuis serovar 4 or 5 from post-weaned pigs with PMWS. The piglets were vaccinated intramuscularly with 2.0ml of M+$Parapac^{(R)}$ in experimental group or normal saline in control group at 1 week of age. A same booster dose was given at 3 weeks of age. In order to value the antibody titer to H parasuis using by tube agglutination test, blood samples were collected from piglets at the aged of 1 week, 6 and 14 weeks. In experimental group and control group, the average antibody titers were $32.5{\pm}21.0,\;114.5{\pm}34.0,\;98.1{\pm}55.4$ and $32.9{\pm}18.6,\;25.8{\pm}36.9,\; 746.7{\pm}1,215.8$ at the aged of 1 week, 6 and 14 weeks, respectively. The cumulative clinical sign indexes by standard guideline of Schering-Plough Animal Health Corp were 486 and 1,069, respectively. The average daily gains and feed conversion rates were $0.553{\pm}0.016kg$ and $0.492{\pm}0.004kg$, and 1.99 and 2.24, respectively. The average gross lesion scores were $1.0{\pm}0.8$ and $1.9{\pm}0.6$, respectively. According to these results, the M+$Parapac^{(R)}$ containing H parasuis serovar 12 may be induce circulating antibodies that cross-react with serovar 4 or 5 and have a protection of PMWS with H parasuis.