The purpose of this study was to measure maximum bite force and to investigate its relationship with anteroposterior, vertical, and transverse facial skeletal measurements. From among the dental students at the College of Dentistry, forty subjects (26 male and 14 female) were selected. With two sets of strain gauge, maximum bite force at the right and left first molars and anterior teeth was measured in the morning and afternoon. After taking lateral and posteroanterior cephalograms, fifty and nineteen variables were evaluated, respectively Paired t-tests and an independent t-test were done and correlation coefficients were obtained. 1. The maximum bite force at the first molars was $68.0\pm13.9kg$. in males and $55.6\pm10.5kg$ in females (p<0.05) while the force at the anterior teeth was $8.4\pm4.9kg\;and\;1.1\pm3.4kg$ respectively (p<0.05). 2. Some tendency for a greater value of maximum bite force at the preferred side was observed but not statistically significant (p>0.05). 3. Significant difference was observed between the strong bite force group and the weak bite force group in some cephalometric and other measurements (p<0.05). N-S-Ar, S-Ar-Go, FH-Hl, IMPA and MMO showed a significant difference in posterior maximum bite force (P). N-S-Ar and FH-H1 also showed a significant difference in anterior maximum bite force (A). 4. Several cephalometric variables showed some correlation with maximum bite force (p<0.05). N-S-Ar, S-Ar-Go, UGA, FH-H6, FH-H1, body weight and MMO were significantly correlated with posterior maximum bite force (P). Go-Me, P-1 and IMPA were significantly correlated with anterior maximum bite force (A).
Journal of Korean Society of Occupational and Environmental Hygiene
/
v.15
no.2
/
pp.124-134
/
2005
To investigate the exposure effect of polynuclear aromatic hydrocarbons (PAHs), we measured airborne total PAHs as an external dose, urinary 1-hydroxypyrene (1-OHP) as an internal dose of PAHs exposure, and analyzed the relationship between urinary 1-OHP concentration and PAHs exposure. The study population contained 44 workers in steel-pipe coating and paint manufacture industries. The airborne PAHs was obtained during survey day, and urine were sampled at the end of shift. Personal information on age, body weight, height, eniployment duration, smoking habit, and alcohol consumption was obtained by a structured questionnaire. Airborne PAHs were analyzed by the gas chromatograph with mass selective detector. Urinary 1-OHP levels were analyzed by the high performance liquid chromatograph with ultraviolet wavelength detector. For statistical estimation, t-test, ${\chi}^2$-test, analysis of variance, correlation analysis, arid regression analysis were executed by SPSS/PC (Windows version 10). The mean of environmental total PAHs was $87.8{\pm}7.81{\mu}g/m^3$. The mean concentration ($526.5{\pm}2.85{\mu}g/m^3$) of workers in steel-pipe coating industries using coal tar enamel was the higher than that ($17.5{\pm}3.36{\mu}g/m^3$) of workers in paint manufacture industries using coal tar paint. The mean of urinary 1-OHP concentration ($51.63{\pm}3.144{\mu}\;mol/mol$ creatinine) of workers in steel-pipe coating industries was the higher than that ($2.33{\pm}4.709{\mu}\;mol/mol$ creatinine) of workers in paint manufacture industries. The mean of urinary 1-OHP concentration of smokers was the higher than that of non-smokers. There was significant correlation between the urinary concentration of 1-OHP and the environmental concentration of PAHs (r=O.S48, p<0.001), pyrene(r=0.859, p<0.001), and urinary cotinine (r=0.324, p<0.05). The regression equation between the urinary concentration of 1-OHP in ${\mu}g/g$ creatinine($C_{1-OHP}$) and airborne concentration of PAHs (or pyrene) in ${\mu}g/m^3$ ($C_{PAHs}$ or Cpyrene) is: Log ($C_{1-OHP}$)=-0.650+0.889×Log($C_{PAHs}$), where $R^2=0.694$ and n=38 for p<0.001.Log ($C_{1-OHP}$)=1.087+0.707${\times}$Log(Cpyrene), where $R^2=0.713$ and n=38 for p<0.001. From the results of stepwise multiple regression analysis about 1-OHP, significant independents were total PAHs and urinary cotinine (adjusted $R^2=0.743$, p<0.001). In this study, there were significant correlation between the urinary concentration of 1-OHP and the airborne concentration of PAHs. The urinary 1-OHP was effective index as a biomarker of airborne PAHs in workplace. But it was influenced by non-occupational PAHs source, smoking.
This study was performed to prepare the verification film for localizing beam-target position with the Photon Knife radiosurgery system (PKRS) using linear accelerator(Mitsubishi, Model ML-15MDX). We developed a laser calibration system using a reticle of transparent lucite to detect Inlet and outlet beams. We verified fixation of the second collimator with film mounted on a holder in the shape of an octagon block 5cm apart from the isocenter. The film was exposed to photon beams of linear accelerator at an interval of 45 degrees during the gantry movement. There were no shifts in the beam of the second collimator during gantry movement. We used a position marker which is designed a head-shaped small lead block and a 10 mm in diameter of steel bead in the plastic tube. The position marker helped to verify the beam directions with patient position in multi-arc and trans-multi-arc of PKRS The verification of beam alignments showed an average 0.8$\pm$0.26 mm discrepancy in LINAC-gram images of PKRS. In our study, the couch movement was $\pm$5 mm laterally, while it shook $\pm$ 2 mm toward the couch axis. The couch, however, was immediately returned to the initial site after shaking. Thus, we postulate that the beam-target position(s) should be verified with LINAC-gram in a stereotactic radiosurgery system to achieve the accuracy of beam-target alignment.
Effect of welding parameters such as current, speed and electrode pressure on the weld quality of tin coated steels for small containers was discussed in this paper. Welding was performed with low frequency wire seam welding system which was loaded with 1.5mm in diameter copper wire electrode. The welding parameters were monitored at the position close to the welding spot so as to minimize the instrumentation error, and the signals were stored into a digital data acquisition system before analysis. Results showed that critical current for sufficient nugget size increased as the base material thickness increased, while the width of the optimum welding range was reduced. The acceptable welding condition derived from this study was found to be effective within the thickness range of $\pm$10% of the nominal (0.25mm) thickness. Tin coating layer was proved not to affect seriously on the weld quality, i.e. strength and formability, since consumable wire electrode was used in this process. Test results also demonstrated that the welding current was thought to be the most effective parameter to form an acceptable weld, while welding speed or electrode pressure exerted less effect on the nugget formation. However, these two parameters played an important role because the former was related to the nugget overlap interval, and the latter, to the formation of expulsion during welding.
The objectives of this study were to examine the lung injury and inflammation caused by manual metal arc stainless steel(MMA-SS) welding fume inhalation and to evaluate the recovery process. Sprague-Dawley rats were exposed to MMA-SS welding fumes for 2 h per day in a whole-body exposure chamber, with a total suspended particulate(TSP) concentration of $51.4{\pm}2.8mg/m^3$(low dose) or $84.6{\pm}2.9mg/m^3$(high dose) for 30 days. The animals were sacrificed after 30 days of exposure as well as after a 30-day recovery period. To assess the inflammatory or injury responses, cellular and biochemical parameters as well as cytokines were assayed in the bronchoalveolar lavage fluid(BALF). MMA-SS welding fume exposure led to a significant elevation in the number of alveolar macrophages(AM) and polymorphonuclear cells(PMN). Additionary, the values of $\beta$-n-acetyl glucosaminidase($\beta$-NAG) and lactate dehydrogenase(LDH) in the BALF were increased in the exposed group when compared to controls. After 30 days of recovery from exposure, a significant reduction in inflammatory parameters of BALF was observed between the exposed and recovered groups. Slight, but significant elevations were noted in the number of AM and PMN in the recovered groups, and AM that had been ingested fume particles still remain in the lungs. In conclusion, these results indicated that welding fumes induced inflammatory responses and cytotoxicity in the lungs of exposed rats. Fume particles were not fully cleared from lungs even after a 30-day recovery period.
Ha, Eun-Hee;Lim, Hyun-Sul;Wie, Cha-Hyung;Kwak, Jung-Ok
Journal of Preventive Medicine and Public Health
/
v.29
no.1
s.52
/
pp.113-131
/
1996
This study was carried out to evaluate the relations among workers' general characteristics, work-related behaviors and health related behaviors in a steel industry with 1,134 workers in Pohang. The results were as follows; 1. The mean age of workers was 50 years old and working duration was 15 years and over. Most of them were married(94.5%) and had studied beyond high school (53.0%). They performed three shift work and most of them(63.0%) had experienced industial accidents. The frequency of noise and dust exposure was defined by a minimum of 6 hours per day, and workers complained about noise exposure(62.9%) and dust(55.6%). There were current smokers(67.7%), current drinkers(74.3%) and current exercising workers(32.3%) in the industry. The number of cigarette consumption in current drinkers was significantly high $(13.6{\pm}8.4\;pieces/day)$ and the alcohol consumption in current smokers was significantly high$(104.5{\pm}113.5\;g/wk)$. And the number of cigarette consumption of exercisers was significantly low and the alcohol consumption of exercisers was higher than non-exercisers. 3. The ratio of current smokers on frequent noise in exposed workers versus non-exposed workers was not significantly high but the current drinkers in frequent noise and dust exposed workers was significantly higher than non-exposed. 4. The normal levels of SGOT workers in non-smokers were significantly higher than in current smokers, and the normal levels of LFT (SGOT, SGPT, $\gamma-GTP$ workers in nondrinkers were significantly high. The normal levels of SBP and DBP workers in current smokers were not significantly high but were significantly high in non-drinkers. 5. The ratio of current smokers in voters unsatisfied with their job and working condition was higher than non-smokers, but the ratio of current drinkers in workers satisfied with their job and working condition were higher. 6. The significant factors for SGOT and $\gamma-GTP$ were age, the drinking amount and BMI. But the only significant factor for r-GTP was BMI. The significant factors for DBP were age, the alcohol consumption and BMI. And the significant factors for SBP were age, BMI.
Currently, in vitro suspension tests using tubes are used as a authorized test method for sanitizers and disinfectants. However, the methods could not accurately assess the efficacy of sanitizers and disinfectant on the food-contacted surfaces in the field. This study evaluated the effectiveness of 5 kinds of representative sanitizers and disinfectants against E. coli and S. aureus to compare three quantitative surface testing methods that have been internationally standardized. As a result, the ASTM E2111-05 (ASTM(1)) test method obtained 5.18 $\pm$ 0.03 and 5.27 $\pm$ 0.04 log cfu/carrier reduction in dealing with E. coli and S. aureus, respectively, the ASTM E2197-02 (ASTM(2)) test method obtained 4.63 $\pm$ 0.04 and 3.97 $\pm$ 0.03 log cfu/carrier reduction and the CEN EN 13697 test method should 6.14 $\pm$ 0.05 and 5.31 $\pm$ 0.10 log cfu/carrier reduction in clean condition (CEN(1)) but 4.37 $\pm$ 0.02 and 4.06 $\pm$ 0.01 log cfu/carrier reduction in dirty condition (CEN(2)). Among them, CEN(1) showed the highest bactericidal effects, whereas ASTM(2) and CEN(2) revealed low performance (p < 0.05). In conclusion, the bactericidal effects of the ASTM(2) method and the CEN EN 13697 method adopting stainless steel were lower than the ASTM(1) method, which uses glass. The effectiveness assessment results among nationally accredited test methods were different each other. This implies that they could not fit for in the accurate evaluation of sanitization and disinfection on food-contact surfaces in practical food-processing fields. These results could be used as a basic data for establishment of an official surface test methods applicable in the field.
It has been widely reported that carbide-free bainitic steels or super-bainite TRIP (SB-TRIP) steels for the automotive industry are a new family of steels offering a unique combination of high strength and ductility. Hence, it is important to exactly evaluate the volume fraction of RA and to identify the 3-D morphology of constituent phases, because it plays a crucial role in mechanical properties. Recently, as electron back-scattered diffraction (EBSD) equipped with focused ion beam (FIB) has been developed, 3-D EBSD technique for materials science are used to these steels. Moreover, newly developed atom probe tomography (APT) technique can provide the exact distribution and chemical concentration of alloying elements in a sub-nm scale. The APT analysis results indicate exactly the distribution and composition of alloying elements in the austenite and bainite phases of SB-TRIP steels with the atomic-scale resolution. And thus, no partitioning of aluminum and manganese atoms was showed between the austenite containing $7.73{\pm}0.39$ at% C and the bainitic ferrite associated with $0.22{\pm}0.06$ at% C in SB-TRIP steel.
The robust and large-area applicable metal shadow masks with a high aspect ratio more than 20 are fabricated by a combination of micro-electro-discharge machining (${\mu}$-EDM) and electro chemical etching (ECE). After defining S/D contacts using a 100 ${\mu}m$ thick stainless steel shadow mask, the top-contact pentacene TFTs with channel length of 5 ${\mu}m$ showed routinely the results of mobility of 0.498 ${\pm}$ 0.05 $cm^2$/Vsec, current on/off ratio of 1.6 ${times}$$10^5$, and threshold voltage of 0 V. The straightly defined atomic force microscopy (AFM) images of channel area demonstrated that shadow effects caused by the S/D electrode deposition were negligible. The fabricated pentacene TFTs have an average channel length of 5 ${\pm}$ 0.25 ${\mu}m$.
This research was conducted in the laboratory to investigate an alternative of Copper(Cu) removal from an heavymetal wastewater using the electrochemical precipitation(ECP) process. The ECP unit consisted of an electrolytic cell made of Titanium plate and Steel plate representing anode and cathode. The DC power source applied to the ECP unit had electrical potential(E) of 50$\pm$ 1V, respectively. The synthetic wastewater used in the experiments contained Cu in the 10 mg/l concentration and the electrode separation were 2, 3, 4 cm and the initial pH were 3, 6, 9, 12, and electrolytic concentration were 0.005, 0.0125, 0.025, 0.0375 mole, and the real heavymetal wastewater used in the experiments. From the experiment for removal efficiency according to pH variation, the low pH area doesn't give the coagulation effect by Ti(OH)$_4$ because process interfere with the coagulation and oxidation reaction, therefore the optimum pH was 4-7. The removal rate was 97.75% after the lapse of 30 minutes when copper concentration and electrolytic concentration were respectively 10 mg/l and 0.025 mole. The removal rate was 96.41% after the lapse of 30minutes when the real heavymetal wastewater used. The optimum consumption of power showed 27KWh/m$^3$ when copper concentration, electrolyte concentration and cell potential were respectively 10 mg/l, 0.025 mole and 50$\pm$ 1 Volt.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.