• Title/Summary/Keyword: PM steel

검색결과 244건 처리시간 0.023초

기상응축 열교환을 이용한 고정밀 등온 가열로 개발 (Development of Heat-treatment Furnace with Maximum Uniform Zone using Gas-phase Condensing Heat Exchange)

  • 홍현선;공만식;강환국
    • 열처리공학회지
    • /
    • 제22권3호
    • /
    • pp.162-168
    • /
    • 2009
  • A horizontal tube furnace with a wide uniform-temperature zone was developed using isothermal characteristics of a heat pipe. The heat pipe heating system consists of a concentric annular shaped stainless-steel container, sodium as a working fluid and a screen mesh wick structure. The performance test of the heat pipe revealed that temperature changes along seven consecutive positions of the heat pipe outer wall were less than${\pm}0.1^{\circ}C$, thereby ensuring the high isothermal property. The isothermal property of the heat pipe-adapted tube fumace was investigated and compared to a conventional non-heat pipe type tube furnace. The temperature distribution measurement showed that the uniform temperature zone, in which temperature change is less than${\pm}$1$^{\circ}$C, of the heat pipe employed tube furnace system was about three times longer compared to the conventional tube furnace system.

산화철에 대한 ICP 성분분석체계 개선 (Improvement of ICP Component Analysis System Related to Iron Oxides)

  • 김규진;송남숙;김재영;최승일;박찬욱;차도현;백대성;이상혁
    • 자원리싸이클링
    • /
    • 제7권4호
    • /
    • pp.76-80
    • /
    • 1998
  • 국내 산화철에 대한 관련업계의 ICP 성분분석체계의 확립을 위해서 산화철분과위원회에서는 분석실무팀을 구성하여 1년간에 걸쳐 많은 시료에 대한 분석을 행하였다. 분기별 회합을 가져 각사의 성분분석 Data에 대하여 상호비교 및 의견교환을 하여 각사의 문제점을 개선하였다. 제1회 회합때는 각사별 성분분석 Datark 상당한 편차를 보였으나, 회가 거듭할수록 보완.개선되어 제3회 분석 Data에서는 각 사별 편차범위가 $\pm$20% 이내로 줄었고, 이러한 결과는 선진 일본철강업체에 비해서도 대등한 수준으로 평가될 수 있다.

  • PDF

전신 방사선치료(Total Body Irradiation, TBI)를 위한 한국인에 맞는 환자 고정장치에 관한 연구 (Development of Patient-Immobilizing Device for Total Body Irradiation (TBI))

  • 김명세
    • 한국의학물리학회지:의학물리
    • /
    • 제13권3호
    • /
    • pp.114-119
    • /
    • 2002
  • 조사 선량의 분포를 저해하지 않으면서 정확한 차폐가 가능하며, 짧은 시간 내에 쉽게 환자를 고정할 수 있으며, 치료 중에 환자가 의식을 잃는 경우에도 다치지 않고 지지될 수 있는, 한국인의 체형에 맞는 전신방사선치료를 위한 고정장치를 개발하고 그 효과를 평가하였다. 230 cm의 키, 100 kg의 체중을 가진 성인 환자도 지지될 수 있도록 지름 5 cm의 스텐레스 원형 봉을 사용하여 프레임을 제작하였고, 의자는 환자가 서 있는 상태에서 환자의 키, 몸의 두께에 맞추어 위치 조절이 가능하도록 고안하였다. 가슴부위의 전면 지지대는 1 cm 두께의 아크릴을 사용하여 지지의 기능과 차폐물의 고정 기능을 겸하게 하였고, 등면의 지지대는 1 cm 두께의 아크릴을 5 mm 두께, 3 cm 넓이의 스텐레스 스틸로 테를 둘러 환자의 지지와 엑스선 필름 카세트 고정장치를 겸하도록 고안하였으며 2개의 상부 도르래와 측면의 핸들로 쉽고 정확하게 조절할 수 있도록 하였다. 머리 고정장치는 비닐과 특수 스펀지를 사용하여 쇠약한 환자의 작은 흔들림도 방지할 수 있도록 하였다. 환자를 원하는 위치에 고정하는데 평균 4분 25초가 소요되었고 반복되는 분할조사의 검교정 필름에서 폐의 차폐물의 위치에 차이가 없었으며, 펜텀 실험과 환자치료에서 $\pm$5%의 선량차이를 보였다. 치료중 환자가 의식을 잃은 경우도 수차 있었으나 쓰러지지 않고 지지할 수 있었다.

  • PDF

채소 및 주방기구에 대한 강산성전해수의 살균효과 (Bactericidal Activity of Strongly Acidic Electrolyzed Water on Various Vegetables and Kitchen Apparatus)

  • 김윤정;최규덕;신일식
    • 한국식품영양과학회지
    • /
    • 제39권5호
    • /
    • pp.776-781
    • /
    • 2010
  • 격막식으로 생산한 강산성전해수(SEW)의 유효염소농도는 $35{\pm}1.2\;ppm$, pH는 $2.3{\pm}0.2$, ORP는 $1,140{\pm}20.4\;mV$이었으며, AEW의 유효염소농도는 $0.1{\pm}0.01\;ppm$, pH는 $11.6{\pm}1.1$, ORP는 $-900{\pm}18.2\;mV$이었다. 6종의 병원성세균(초기균수 $1.0{\times}10^7\;CFU/mL$)에 대한 SEW의 살균효과를 조사한 결과, 대조구로 사용한 유효염소농도 35 ppm의 차아염소산 나트륨 용액의 경우, 60초간 처리하여도 2~4 log 정도의 균밖에 감소하지 않았으나 SEW는 60초간 처리로 포자를 형성하는 B. cereus를 제외한 나머지 5종의 병원성세균을 모두 살균하였으며, B. cereus의 경우 완전하게 살균하지는 못하였지만 약 4 log CFU/g 이상이 감소하여, 같은 유효염소농도라도 SEW가 차아염소산나트륨 용액보다 살균력이 뛰어나다는 것을 알 수 있었다. 채소의 경우, AEW로 세척 후 SEW 처리하였을 때가 SEW 단독처리보다 살균효과가 더 좋았다. 한편 콩나물, 무순의 경우 AEW로 30초간 세척 후 SEW로 30초간 처리하여도 균수는 각각 $2.50{\pm}0.13$, $2.19{\pm}0.13$만 감소하였고 4 log CFU/g 이상의 균이 잔존하고 있었다. 식기와 컵은 차아염소산나트륨 용액(유효염소농도 35 ppm) 30초간 처리로는 1.19~1.28 log CFU/$100\;cm^2$ 정도만 감소하였지만, SEW 30초간 처리로 균이 검출되지 않았다. 고무장갑의 경우 유일하게 대장균군이 검출되었으며 SEW 30초간 처리로 고무장갑 표면의 일반세균과 대장균군은 대조군인 수도수에 비하여 약 2 log CFU/$100\;cm^2$ 이상 감소하였으나 완전한 살균은 되지 않았다.

하악 과두 골절의 개방 정복 시 근위 골편의 수복법 (A Technique for Assist in Positioning the Proximal Segment during Open Reduction of a Fractured Mandibular Condyle)

  • 김명국
    • Archives of Plastic Surgery
    • /
    • 제33권6호
    • /
    • pp.792-796
    • /
    • 2006
  • Purpose: After exposure of fracture site, the proximal segment must be reduced to their preinjury position for open reduction of fractured mandibular condyle. We examined the use of inter-maxillary fixation screws or titanium screws tied with stainless steel wire to assist in positioning of proximal segment. Since it enables to make a relatively small preauricular incision by not disturbing the operative field like Moule pin, we can reduce the danger of injury to the facial nerve. Methods: A preauricular approach was used for exposure, reduction, and rigid fixation in 4 cases of mandibular condylar fractures. Inter-maxillary fixation screws or titanium screws tied with stainless steel wire were used to assist in aligning proximal segment. The joints were submitted to functional exercises and postoperative radiologic and clinical follow-ups were performed. Results: No facial nerve lesions were found in all 4 cases. Radiologic follow-up showed correct reduction and fixation in all 4 cases. Clinical follow-up showed an initial limitation, but normal morbility of the condyle was achieved within 4 months after the operation, with a maximum mouth opening of $34.1{\pm}5.2mm$ after 12 months. There found no occlusal disturbances, no trismus, no lateral deviations of the mandible. Conclusion: By using Inter-maxillary fixation screws tied with stainless steel wire, it was shown that reducing the proximal segment to their preinjury position is easy to perform and it enables us to make a minimal dissection below preauricular skin incision to avoid facial nerve injury.

복합 연자성 소재의 전동기 코어손실 예측을 위한 실험적 분석 (Experimental Analysis for Core Losses Prediction in Electric Machines by Using Soft Magnetic Composite)

  • 박의종;김용재
    • 한국전자통신학회논문지
    • /
    • 제16권3호
    • /
    • pp.471-476
    • /
    • 2021
  • 분말 야금 기술에 의한 복합 연자성 재료는 전기기기에 일반적으로 사용되는 종래의 전기강판보다 많은 장점을 가지고 있으며, 그 관련 기술은 최근에 상당한 발전을 거듭하고 있다. 복합 연자성 재료는 일반적으로 분말의 형태로 인해 자기적 등방성 가지므로 3차원 자속 및 복잡한 구조의 전기기기 구성에 적합하다. 하지만 SMC와 같이 등방성 자기 특성을 가지는 재료는 복잡한 벡터 히스테리시스를 가지므로 정확한 손실 특성을 예측하는 것이 매우 어렵다. 따라서 본 논문에서는 전기강판 및 SMC의 링 타입 시편을 제작하고 시편 크기에 따라 자기적 특성을 측정한 후, 측정된 자기적 정보를 이용하여 800Hz 이상에서 구동하는 고속 영구자석 전동기의 전자계 해석을 수행하였다. 또한, 해당 모델의 시작품을 제작하고 효율 측정 및 비교를 통해 본 논문의 신뢰성을 입증하였다.

원격강내조사용 Co-60 선원의 대체용 Ir-192 선원의 조사선량결정 및 선량 등방성조사 (Determination of Exposure Dose Rate and Isotropic Distributions of Substitute High Dose Rate Ir-192 Source for Co-60 Brachytherapy Source)

  • 최태진;원철호;김옥배;김시운;김금배;조운갑;한현수;박경배
    • 한국의학물리학회지:의학물리
    • /
    • 제9권1호
    • /
    • pp.55-64
    • /
    • 1998
  • 고선량률 원격 강내조사 선원은 전량 외국에서 수입되어 왔으며, 최근 Co-60 소선원의 공급부진으로 초기 도입시의 치료시간에 비해 4내지 5배의 시간을 조사하게 되어 대체용 선원의 개발이 크게 요구되고 있다. 이 연구는 국내 하나로 원자로의 중성자를 이용하여 $^{191}$ Ir(n,Υ)$^{192}$ Ir 핵반응을 일으켜 Ir-192 선원 2.87 Ci (밀봉 1.012 Ci)를 생산하고, 고선량률 원격 강내조사선원의 선량특성을 조사하였다. 제작선원에 대한 조사선량률은 아크릴 지지체의 중앙에 아크릴 아프리케이터를 고정하고 선원의 중심으로부터 각각 5, 10, 20 cm 거리에 전리함을 설치하여 일정시간 선원을 노출시켜 측정한 결과 6.36 $\pm$ 0.147 Rm$^2$/GBq-hr (2.350 $\pm$ 0.054 R$cm^2$/mCi-hr)을 결정하였으며, 측정오차는 1$\sigma$ 는 2.2% 였다. 계산선량은 조사선량률 상수 4.69 R$cm^2$/h-mCi 와 Ir-192 에너지 스펙트럼을 이용한 선원자체 및 철에 대한 질량흡수계수를 통해 구했으며, 실제 측정선량과 평균 3.8 % 오차범위에서 일치하였다. 선량 등방성은 선원의 측방향과 축 및 대각선방향으로 전리함을 이용하여 측정한 결과 3 % 이내 균등한 선량을 나타내었으며, 필름선량에서도 균등선량분포를 확인할 수 있었으며, Co-60 선원과 유사한 선량분포를 얻었을 수 있었다. 특히 본 연구의 선량특성조사는 강내조사선량선원 대체용의 선원개발과 선량계획 전산화의 근거가 될 것으로 믿는다.

  • PDF

측방가압충전시 Nickel-Titanium spreader의 사용유무가 근관충전효과에 마치는 영향 (INFLUENCE OF NICKEL-TITANIUM SPREADER ON THE SEALING ABILITY IN LATERAL CONDENSATION TECHNIQUE)

  • 민경산;홍찬의;조용범
    • Restorative Dentistry and Endodontics
    • /
    • 제25권3호
    • /
    • pp.381-389
    • /
    • 2000
  • Lateral condensation with gutta-percha and sealer has been shown to provide an excellent apical seal; however, the lateral condensation technique has demonstrated less favorable apical leakage results in curved canals when compared with straight canals. Placement of endodontic spreaders to within 1 to 2mm of the root canal working length has been advocated for optimum gutta-percha obturation. Due to their stiffness, stainless-steel(SS) spreaders will often fail to achieve this position in curved canals. Newly marketed nickel-titanium(NT) spreaders may offer an advantage in this regard due to the increased flexibility of these instruments. The purpose of this study was to evaluate the effect of NT finger spreader on the sealing ability in lateral condensation technique, compared with conventional SS finger spreader. Twenty four standardized resin models simulating curved canals(30 degree) were randomly placed into 2 groups and instrumented to a #30 master apical file size with Ni-Ti Profile .04 taper series using step down technique. Each groups was obturated with standardized gutta-percha cone by standard lateral condensation technique using SS finger spreader, NT finger spreader. And then, each model was sectioned horizontally with microtome at 1, 2, 3, 4, 5mm levels from the apex. At each of 5 levels, ratio of the area of gutta-percha was obtained by calculating the area of gutta-percha to the total area of the canal. The data collected were then analyzed statistically using a t test for independent samples. The results as follows ; 1. The total mean ratio of area of gutta-percha was 89.20${\pm}$7.00(%) for SS spreader group. 92.20${\pm}$5.17(%) for NT spreader group. There was statistically significant difference between each group(p<0.05). 2. At 3mm level, the mean ratio of area of gutta-percha was 88.32${\pm}$5.41(%) for SS spreader group, 95.25${\pm}$2.60(%) for NT spreader group. There was statistically significant difference between each group(p<0.05). At 1,2,4mm levels, NT spreader group showed greater mean ratio of area of gutta-percha than SS spreader group, too. But there was no statistically significant difference. 3. At 5mm level, the mean ratio of area of gutta-percha was 91.83${\pm}$3.42(%) for SS spreader group, 87.91${\pm}$3.68(%) for NT spreader group. There was statistically significant difference between each group(p<0.05). This study concluded that the NT spreader demonstrated somewhat favorable apical sealing effect than SS spreader in prepared curved canals. The clinical use of NT spreaders may enhance our ability to create better apical seals in curved canals, but further studies in this area will help clarify some of the remaining areas with which practitioners are concerned, such as compaction forces exerted by NT spreaders.

  • PDF

3차원 영상에 의한 안면 비대칭의 분석 (Analysis of Facial Asymmetry with Three-Dimensional Morphometry)

  • 조홍규
    • 대한치과기공학회지
    • /
    • 제27권1호
    • /
    • pp.27-39
    • /
    • 2005
  • This study is to show the qualitative analytic methods of facial asymmetry with three-dimensional morphometry and find out asymmetry change resulted from enlarging three local regions. Steel balls (1.2mm in diameter) were attached in twenty seven landmarks of a symmetrical artificial human skull. This artificial human skull was used as experimental materials. Twelve different asymmetrical artificial human skulls were formed by gradually enlarging the mandibular body length, gonial angle, and ramus height of the left hemiface. From the three-dimensional morphometry of each skull type, nine local area measurements and three total sum area measurements(representing the mandibular area, maxillary area, and lower facial area) were acquired and made into the surface area asymmetry degree. Menton deviation itself was used as the surface area asymmetry degree while right-left percentages were used in the other measurements. These surface area asymmetry degrees were compared with each other to find out asymmetry change according to the degree of actual facial asymmetry. Through the statistical analysis, following results were obtained. The results were as follows: 1. Left maxillary area of artificial human skull was 7.13$\pm$0.26% larger while mandibular area was 4.14$\pm$0.12% smaller than each those of right hemiface. After all, left lower facial area was 1.44$\pm$0.07% larger than those of right hemiface.(n=7). 2. Among the reduce rates of surface area asymmetry degree resulted from enlarging three local regions, ramus height was similar to mandibular body length while it was bigger than those of gonial angle. 3. Among the increase rates of menton deviation resulted from enlarging the local regions, ramus height was the biggest, mandibular body length was the second and gonial angle was the smallest. These results suggest that three-dimensional morphometry can be used to qualitatively analyse facial asymmetry and the asymmetry degree is more influenced by enlarging the ramus height, mandibular body length than those of gonial angle.

  • PDF

Comparison of cyclic fatigue life of nickel-titanium files: an examination using high-speed camera

  • Ozyurek, Taha;Keskin, Neslihan Busra;Furuncuoglu, Fatma;Inan, Ugur
    • Restorative Dentistry and Endodontics
    • /
    • 제42권3호
    • /
    • pp.224-231
    • /
    • 2017
  • Objectives: To determine the actual revolutions per minute (rpm) values and compare the cyclic fatigue life of Reciproc (RPC, VDW GmbH), WaveOne (WO, Dentsply Maillefer), and TF Adaptive (TFA, Axis/SybronEndo) nickel-titanium (NiTi) file systems using high-speed camera. Materials and Methods: Twenty RPC R25 (25/0.08), 20 WO Primary (25/0.08), and 20 TFA ML 1 (25/0.08) files were employed in the present study. The cyclic fatigue tests were performed using a dynamic cyclic fatigue testing device, which has an artificial stainless steel canal with a $60^{\circ}$ angle of curvature and a 5-mm radius of curvature. The files were divided into 3 groups (group 1, RPC R25 [RPC]; group 2, WO Primary [WO]; group 3, TF Adaptive ML 1 [TFA]). All the instruments were rotated until fracture during the cyclic fatigue test and slow-motion videos were captured using high-speed camera. The number of cycles to failure (NCF) was calculated. The data were analyzed statistically using one-way analysis of variance (ANOVA, p < 0.05). Results: The slow-motion videos were indicated that rpm values of the RPC, WO, and TFA groups were 180, 210, and 425, respectively. RPC ($3,464.45{\pm}487.58$) and WO ($3,257.63{\pm}556.39$) groups had significantly longer cyclic fatigue life compared with TFA ($1,634.46{\pm}300.03$) group (p < 0.05). There was no significant difference in the mean length of the fractured fragments. Conclusions: Within the limitation of the present study, RPC and WO NiTi files showed significantly longer cyclic fatigue life than TFA NiTi file.