• Title/Summary/Keyword: PM steel

Search Result 243, Processing Time 0.021 seconds

Improvement of ICP Component Analysis System Related to Iron Oxides (산화철에 대한 ICP 성분분석체계 개선)

  • ;;;;;;;;Shigeru Tominaga
    • Resources Recycling
    • /
    • v.7 no.4
    • /
    • pp.76-80
    • /
    • 1998
  • In order to establish the ICP composition analysis system of the compotes which have been producing and using the domestic iron oxides, the Sectional Committee of Iron Oxides had organized an analysis working team. which carried out the component analysis of several samples and den discussed about thou analysis results through 1 year. At the 1st meeting, the component deviation was reduced. At the 3rd meeting, the deviation range if each company was reduced below ${\pm}$20% and it means to be improved on an analysis level with Japaness steel companies.

  • PDF

Development of Patient-Immobilizing Device for Total Body Irradiation (TBI) (전신 방사선치료(Total Body Irradiation, TBI)를 위한 한국인에 맞는 환자 고정장치에 관한 연구)

  • 김명세
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.114-119
    • /
    • 2002
  • A immobilizing device that is essential for correct lung and lens shielding with homogenous dose distribution in fractionated total body irradiation was developed and it's efficiency was evaluated. The main frame was made of stainless steel bar (5 cm in diameter) to withstand up to 230 cm in height and 100 kg in weight to prevent any injury even in unconsciousness condition. The saddle was designed to adjust the body weight and hight of standing patients. Chest and back supporter were made of 1 cm acryl which could fix the lung block and cassette holder. Leather and sponge pedding were used for head rest to keep patients comfortable. The device was strongly fixed by specially designed bolts on the bottom panel which was made of 1 cm stainless steel and 10 cm thick wooden board. Precise manipulation ($\pm$2 mm) was possible by upper two pulleys and side handles. Average four minutes twenty five seconds were needed for exact setting in fractionated TBI. No significant difference of lung block location on repeated verification films was confirmed and relatively homogeneous dose distribution was measured in rando phantom experiments and patient treatments ($\pm$5%). This immobilizing device was very efficient to keep correct position of patients, which is essential for better result and less complication in fractionated TBI.

  • PDF

Bactericidal Activity of Strongly Acidic Electrolyzed Water on Various Vegetables and Kitchen Apparatus (채소 및 주방기구에 대한 강산성전해수의 살균효과)

  • Kim, Yun-Jung;Choi, Kyoo-Duck;Shin, Il-Shik
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.5
    • /
    • pp.776-781
    • /
    • 2010
  • The properties and bactericidal activities of strongly acidic electrolyzed water (SEW) against food-borne pathogenic bacteria, vegetables and kitchen apparatuses were investigated. The available chlorine concentration, pH and oxidation reduction potential (ORP) of SEW were $35{\pm}1.2\;ppm$, $2.3{\pm}0.2$, and $1,140{\pm}20.4\;mV$, respectively. Five strains of food-borne bacteria with initial cell number of 7.00 log CFU/mL were not detected except Bacillus cereus after treatment with SEW for 60 sec. The numbers of Bacillus cereus were reduced to 2.08{\pm}1.00 log CFU/mL at the same condition. In vegetables, SEW treatment after washing strongly in alkalic electrolyzed water (AEW) showed better bactericidal effects than SEW only. The viable cell on stainless steel bowl ($3.86{\pm}2.49\;\log\;CFU/100\;cm^2$) and cup for water ($2.40{\pm}1.80\;\log\;CFU/100\;cm^2$) were not detected by SEW treatment (35 ppm of available chlorine concentration) for 30 sec, but survival of more than 1.00 log CFU/$100\;cm^2$ of viable cell was shown by washing of sodium hypochlorite solution at the same condition. On the other hand, the coliform group bacteria ($5.08{\pm}4.00\;CFU/100\;cm^2$) were detected on rubber globe only, and more than 2.00 log CFU/$100\;cm^2$ of viable cell and coliform group bacteria on it survived, though it was washed with flowing SEW for 30 sec.

A Technique for Assist in Positioning the Proximal Segment during Open Reduction of a Fractured Mandibular Condyle (하악 과두 골절의 개방 정복 시 근위 골편의 수복법)

  • Kim, Myung Good
    • Archives of Plastic Surgery
    • /
    • v.33 no.6
    • /
    • pp.792-796
    • /
    • 2006
  • Purpose: After exposure of fracture site, the proximal segment must be reduced to their preinjury position for open reduction of fractured mandibular condyle. We examined the use of inter-maxillary fixation screws or titanium screws tied with stainless steel wire to assist in positioning of proximal segment. Since it enables to make a relatively small preauricular incision by not disturbing the operative field like Moule pin, we can reduce the danger of injury to the facial nerve. Methods: A preauricular approach was used for exposure, reduction, and rigid fixation in 4 cases of mandibular condylar fractures. Inter-maxillary fixation screws or titanium screws tied with stainless steel wire were used to assist in aligning proximal segment. The joints were submitted to functional exercises and postoperative radiologic and clinical follow-ups were performed. Results: No facial nerve lesions were found in all 4 cases. Radiologic follow-up showed correct reduction and fixation in all 4 cases. Clinical follow-up showed an initial limitation, but normal morbility of the condyle was achieved within 4 months after the operation, with a maximum mouth opening of $34.1{\pm}5.2mm$ after 12 months. There found no occlusal disturbances, no trismus, no lateral deviations of the mandible. Conclusion: By using Inter-maxillary fixation screws tied with stainless steel wire, it was shown that reducing the proximal segment to their preinjury position is easy to perform and it enables us to make a minimal dissection below preauricular skin incision to avoid facial nerve injury.

Experimental Analysis for Core Losses Prediction in Electric Machines by Using Soft Magnetic Composite (복합 연자성 소재의 전동기 코어손실 예측을 위한 실험적 분석)

  • Park, Eui-Jong;Kim, Yong-Jae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.3
    • /
    • pp.471-476
    • /
    • 2021
  • Soft magnetic composite (SMC) materials based on powder metallurgy have a number of advantages over the conventional electrical steel sheets commonly used in electric machines. Thus, technologies related to these materials have shown significant improvement in recent years. In general, SMCs are magnetically isotropic owing to the shape of the powder, which makes them suitable for the construction of electric machines with three-dimensional flux and complex structures. However, the materials with isotropic magnetic properties (such as SMCs) have complex vector hysteresis; thus, it is very difficult to predict accurate loss properties. Therefore, we manufactured ring-type specimens of electrical steel sheets and SMC, which analyzed their magnetic properties according to the specimen size, and performed the electromagnetic field analysis of a high-speed permanent magnet (PM) motor driven at 800 Hz or higher using the measured magnetic information to compare the core loss of the motor. The reliability of this paper has been verified by measuring the efficiency after manufacturing the motor.

Determination of Exposure Dose Rate and Isotropic Distributions of Substitute High Dose Rate Ir-192 Source for Co-60 Brachytherapy Source (원격강내조사용 Co-60 선원의 대체용 Ir-192 선원의 조사선량결정 및 선량 등방성조사)

  • 최태진;원철호;김옥배;김시운;김금배;조운갑;한현수;박경배
    • Progress in Medical Physics
    • /
    • v.9 no.1
    • /
    • pp.55-64
    • /
    • 1998
  • In recent, the demand of development of the high dose rate brachytherapy source increased for substitute for Co-60 source by iridium source, since the supplying Co-60 source is very depressed and the high dose rate brachytherapy sources are entirely imported from the abroad. This study investigated the exposure rates and isotropic dose distributions for the Ir-192 source produced from $\^$191/Ir(n,r)$\^$192/Ir by nuclear reactor in Korea Atomic Energy Research Institute. The activity of source was obtained an 1.012 Ci (the initial activity without encapsulation was 2,87Ci) by measurement with encapsuled stainless steel. The exposure rate of provided Ir-192 source was determined on 6.36 ${\pm}$ 0.147 Rm$^2$/h-GBq (2.350 ${\pm}$ 0.054 Rcm$^2$/mCi-hr) within ${\pm}$ 2.2% discrepancy with IC-10 ion chamber (0.14 cc) which was mounted on the acrylic jig to 5, 10 and 20 cm from the center of source. The calculated doses with 22 most significant spectrum lines were corrected with intrinsic efficiency of the germanium detector were compared to measured exposure dose rates within ${\pm}$3.8 % discrepancy. The authors confirmed the high dose rate Ir-192 source could be replaced the long decayed Co-60 source via investigation of the isotropic dose distributions in lateral, source axis and diagonal direction of source center are very closed to within 3% uncertainties. Especially, this exposure rate constant and isotropic dose distribution will be fundamental to build the high dose rate source and develop the computed therapy planning system.

  • PDF

INFLUENCE OF NICKEL-TITANIUM SPREADER ON THE SEALING ABILITY IN LATERAL CONDENSATION TECHNIQUE (측방가압충전시 Nickel-Titanium spreader의 사용유무가 근관충전효과에 마치는 영향)

  • Min, Kyung-San;Hong, Chan-Ui;Cho, Yong-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.3
    • /
    • pp.381-389
    • /
    • 2000
  • Lateral condensation with gutta-percha and sealer has been shown to provide an excellent apical seal; however, the lateral condensation technique has demonstrated less favorable apical leakage results in curved canals when compared with straight canals. Placement of endodontic spreaders to within 1 to 2mm of the root canal working length has been advocated for optimum gutta-percha obturation. Due to their stiffness, stainless-steel(SS) spreaders will often fail to achieve this position in curved canals. Newly marketed nickel-titanium(NT) spreaders may offer an advantage in this regard due to the increased flexibility of these instruments. The purpose of this study was to evaluate the effect of NT finger spreader on the sealing ability in lateral condensation technique, compared with conventional SS finger spreader. Twenty four standardized resin models simulating curved canals(30 degree) were randomly placed into 2 groups and instrumented to a #30 master apical file size with Ni-Ti Profile .04 taper series using step down technique. Each groups was obturated with standardized gutta-percha cone by standard lateral condensation technique using SS finger spreader, NT finger spreader. And then, each model was sectioned horizontally with microtome at 1, 2, 3, 4, 5mm levels from the apex. At each of 5 levels, ratio of the area of gutta-percha was obtained by calculating the area of gutta-percha to the total area of the canal. The data collected were then analyzed statistically using a t test for independent samples. The results as follows ; 1. The total mean ratio of area of gutta-percha was 89.20${\pm}$7.00(%) for SS spreader group. 92.20${\pm}$5.17(%) for NT spreader group. There was statistically significant difference between each group(p<0.05). 2. At 3mm level, the mean ratio of area of gutta-percha was 88.32${\pm}$5.41(%) for SS spreader group, 95.25${\pm}$2.60(%) for NT spreader group. There was statistically significant difference between each group(p<0.05). At 1,2,4mm levels, NT spreader group showed greater mean ratio of area of gutta-percha than SS spreader group, too. But there was no statistically significant difference. 3. At 5mm level, the mean ratio of area of gutta-percha was 91.83${\pm}$3.42(%) for SS spreader group, 87.91${\pm}$3.68(%) for NT spreader group. There was statistically significant difference between each group(p<0.05). This study concluded that the NT spreader demonstrated somewhat favorable apical sealing effect than SS spreader in prepared curved canals. The clinical use of NT spreaders may enhance our ability to create better apical seals in curved canals, but further studies in this area will help clarify some of the remaining areas with which practitioners are concerned, such as compaction forces exerted by NT spreaders.

  • PDF

Analysis of Facial Asymmetry with Three-Dimensional Morphometry (3차원 영상에 의한 안면 비대칭의 분석)

  • Cho, Hong-Kyu
    • Journal of Technologic Dentistry
    • /
    • v.27 no.1
    • /
    • pp.27-39
    • /
    • 2005
  • This study is to show the qualitative analytic methods of facial asymmetry with three-dimensional morphometry and find out asymmetry change resulted from enlarging three local regions. Steel balls (1.2mm in diameter) were attached in twenty seven landmarks of a symmetrical artificial human skull. This artificial human skull was used as experimental materials. Twelve different asymmetrical artificial human skulls were formed by gradually enlarging the mandibular body length, gonial angle, and ramus height of the left hemiface. From the three-dimensional morphometry of each skull type, nine local area measurements and three total sum area measurements(representing the mandibular area, maxillary area, and lower facial area) were acquired and made into the surface area asymmetry degree. Menton deviation itself was used as the surface area asymmetry degree while right-left percentages were used in the other measurements. These surface area asymmetry degrees were compared with each other to find out asymmetry change according to the degree of actual facial asymmetry. Through the statistical analysis, following results were obtained. The results were as follows: 1. Left maxillary area of artificial human skull was 7.13$\pm$0.26% larger while mandibular area was 4.14$\pm$0.12% smaller than each those of right hemiface. After all, left lower facial area was 1.44$\pm$0.07% larger than those of right hemiface.(n=7). 2. Among the reduce rates of surface area asymmetry degree resulted from enlarging three local regions, ramus height was similar to mandibular body length while it was bigger than those of gonial angle. 3. Among the increase rates of menton deviation resulted from enlarging the local regions, ramus height was the biggest, mandibular body length was the second and gonial angle was the smallest. These results suggest that three-dimensional morphometry can be used to qualitatively analyse facial asymmetry and the asymmetry degree is more influenced by enlarging the ramus height, mandibular body length than those of gonial angle.

  • PDF

Comparison of cyclic fatigue life of nickel-titanium files: an examination using high-speed camera

  • Ozyurek, Taha;Keskin, Neslihan Busra;Furuncuoglu, Fatma;Inan, Ugur
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.3
    • /
    • pp.224-231
    • /
    • 2017
  • Objectives: To determine the actual revolutions per minute (rpm) values and compare the cyclic fatigue life of Reciproc (RPC, VDW GmbH), WaveOne (WO, Dentsply Maillefer), and TF Adaptive (TFA, Axis/SybronEndo) nickel-titanium (NiTi) file systems using high-speed camera. Materials and Methods: Twenty RPC R25 (25/0.08), 20 WO Primary (25/0.08), and 20 TFA ML 1 (25/0.08) files were employed in the present study. The cyclic fatigue tests were performed using a dynamic cyclic fatigue testing device, which has an artificial stainless steel canal with a $60^{\circ}$ angle of curvature and a 5-mm radius of curvature. The files were divided into 3 groups (group 1, RPC R25 [RPC]; group 2, WO Primary [WO]; group 3, TF Adaptive ML 1 [TFA]). All the instruments were rotated until fracture during the cyclic fatigue test and slow-motion videos were captured using high-speed camera. The number of cycles to failure (NCF) was calculated. The data were analyzed statistically using one-way analysis of variance (ANOVA, p < 0.05). Results: The slow-motion videos were indicated that rpm values of the RPC, WO, and TFA groups were 180, 210, and 425, respectively. RPC ($3,464.45{\pm}487.58$) and WO ($3,257.63{\pm}556.39$) groups had significantly longer cyclic fatigue life compared with TFA ($1,634.46{\pm}300.03$) group (p < 0.05). There was no significant difference in the mean length of the fractured fragments. Conclusions: Within the limitation of the present study, RPC and WO NiTi files showed significantly longer cyclic fatigue life than TFA NiTi file.

Design of High Performance Reinforced Concrete Pile for Improvement of Seismic Performance (내진성능 향상을 위한 고성능 철근콘크리트 말뚝 설계에 관한 연구)

  • Park, Chan Sik;Cho, Jeong-Rae;Kim, Young Jin;Chin, Won Jong;Yoon, Hyejin;Choi, Myung Kyu
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.23 no.3
    • /
    • pp.183-190
    • /
    • 2019
  • Recent changes in the construction method of piles to minimize noise, along with the development of high-strength reinforcement, have provided an economical high performance RC pile development to compensate for the disadvantages of existing PHC piles. In this study, a methodology for the development of cross - section details of high performance RC piles of various performances is presented by freely applying high strength steel and concrete. This study suggested a technique for calculating bending moments for a given axial force corresponding to the allowable crack widths and this can be used for serviceablity check. In calculating the design shear force, the existing design equation applicable to the rectangular or the I section was modified to be applicable to the hollow circular section. In particular, in the limit state design method, the shear force is calculated in proportion to the axial force, and the procedure for calculating PV diagram is established. Last, the section details are determined through PM diagrams that they have the similar flexural and axial-flexural performances of the PHC pile A, B and C types with a diameter of 500 mm. To facilitate the application of the selected standard sections to the practical tasks, the design PM diagram and design shear forces are proposed in accordance with the strength design method and limit state design method.