• Title/Summary/Keyword: PLU

Search Result 152, Processing Time 0.028 seconds

THE STUDY ON THE MICROLEAKAGE PATTERN OF FLOWABLE COMPOSITE RESIN RESTORATIONS ACCORDING TO THE TYPE OF ADHESIVE MATERIALS (접착제에 따른 유동성 복합 레진 수복물의 미세누출 양상에 관한 연구)

  • Park, Ji-Eun;Kim, Jong-Soo;Yoo, Seung-Hoon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.3
    • /
    • pp.456-468
    • /
    • 2008
  • This study was performed to evaluate the quality of newly offered dentin bonding system($AdheSE^{(R)}$ One) by comparing the degree of microleakage measured with those of several conventional adhesive materials(AQ Bond Plus and $Adper^{TM}$ Single Bond 2). The quality of hybrid layer and resin tags was analyzed by observing restoration/ tooth interface under SEM. All-in-one system is in the limelight for having advantage of reducing chair time of children with difficult behavior pattern. Therefore the possibility of clinical application of All-in-one system was evaluated. The results obtained are as follows; 1. At the enamel margin, group II(AQ Bond Plus) showed the highest value of microleakage, and the other groups showed decreased value in order of group III($AdheSE^{(R)}$ One) and I($Adper^{TM}$ Single Bond 2). There was statistically significant difference between group II and the others(p<0.05), and no statistical difference was found between group I and III. 2. At the dentin margin, microleakage value was increased in order of group II, I, III and significant difference between all groups(p<0.05). 3. In group I and III, microleakage value measured at the enamel margin was significantly lower than that seen at the dentin margin(p<0.05), and there was no statistical difference in group II. 4. Resin tags observed under SEM were very weak and tangled in group II and III while the strong and thick tags were observed in group I. In conclusion, careful case selection and accurate clinical application is recommended in using AQ Bond Plus and $AdheSE^{(R)}$ One, giving consideration of the results showing its higher microleakage and weaker strength than $Adper^{TM}$ Single Bond 2.

  • PDF

MICROHARDNESS AND SURFACE ROUGHNESS OF SEALANT AND FLOWABLE COMPOSITE RESINS (치면열구전색제와 유동성 복합 레진의 미세 경도 및 표면 조도의 비교)

  • Yang, Kyu-Ho;Choi, Nam-Ki;Kim, Seon-Mi;Choi, Ji-Eun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.3
    • /
    • pp.440-447
    • /
    • 2009
  • This study was performed to compare the wear resistance of sealant and flowable resins for analyzing the effect of flowable resin as a sealant in preventive resin restorations. Specimens were made and Vicker's hardness number and surface roughness were measured. SEM observations of the polished and abraded surfaces were established. Kruskal-Wallis rank test and Mann-Whitney U test at the significant level of ${\alpha}$=0.05 were used. The following results were obtained: 1. The microhardness was decreased among groups in following order: Z350 (3M ESPE, U.S.A), Estelite (Tokuyama Dental, Japan) and Ultraseal (Ultradent, U.S.A). There were significant differences in all groups (p<0.0001). 2. The surface roughness was decreased among groups in following order: Ultraseal XT plus, Palfique Estelite LV and Filtek Z350 flowable. However, there is no statistically significant differences in roughness among Estellite, Z350 and Ultraseal at the significance level of ${\alpha}$=0.05, with p=0.116 3. SEM observation of the unworn and worn surfaces revealed the qualitative differences in the wear appearance among groups. The results in this study indicate that flowable resin is better than sealant in aspect of physical properties.

  • PDF

The influence of Collar design on peri-implant marginal bone tissue (Collar design이 임플랜트 주위 변연골 흡수에 미치는 영향)

  • Kim, Jee-Hwan;Jung, Moon-Kyou;Moon, Hong-Suk;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.1
    • /
    • pp.53-64
    • /
    • 2008
  • Statement of problem: Peri-implant marginal bone loss is an important factor that affects the success of implants in esthetics and function. Various efforts have been made to reduce this bone loss by improving implant design and surface texture. Previous studies have shown that early marginal bone loss is affected by implant neck designs. Purpose: The purpose of this study was to examine the influence of laser microtexturing of implant collar on peri-implant marginal bone loss. Materials and methods: Radiographical marginal bone loss was examined in patients treated with implant-supported fixed partial dentures. Marginal bone level was examined with 101 implant fixtures installed in 53 patients at three periods(at the time of implantation, prosthetic treatment and 6-month after loading). Four types of implants were examined. The differences of bone loss between implants(ITI standard) with enough biologic width and implants(ITI esthetic plus, Silhouette IC, Silhouette IC Laser-$Lok^{TM}$) with insufficient biologic width have been compared. Resorption angles were examined at the time of prosthetic delivery and 6-month after loading. Results and Conclusion: Within the limitation of this study, the following results were drawn. 1. The marginal bone loss of ITI standard and Silhouette IC Laser-$Lok^{TM}$ was less than that of ITI esthetic plus and Silhouette IC(P<0.05). The marginal bone loss between ITI standard and Silhouette IC Laser-$Lok^{TM}$ had no significant statistical difference(P>0.05). There was no significant statistical difference between marginal bone loss of ITI esthetic plus and Silhouette IC(P>0.05). 2. There was no significant difference in marginal bone loss between maxilla and mandible(P>0.05). 3. There was no significant difference in resorption angle among four types of implants(P>0.05). The marginal bone of implants with supracrestal collar design of less than that of biologic width had resorbed more than those with sufficient collar length. The roughness and laser microtexturing of implant neck seem to affect these results. If an implant with collar length of biologic width, exposure of fixture is a possible complication especially in the anterior regions of dentition that demand high esthetics. Short smooth neck implant are often recommended in these areas which may lack the distance between microgap and the marginal bone level. In these cases, the preservation of marginal bone must be put into consideration. From the result of this study, it may be concluded that laser microtexturing of implant neck is helpful in the preservation of marginal bone.

THE EFFECTS OF DRYING AGENTS AND BONDING AGENTS ON THE SHEAR BOND STRENGTH OF SEALANTS TO ENAMEL (치면건조제와 접착제의 사용에 따른 치면열구전색재의 전단결합강도에 관한 연구)

  • Lim, Hyun-Hwa;Jang, Ki-Taek;Kim, Chong-Chul;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.2
    • /
    • pp.196-203
    • /
    • 2003
  • The application of sealants is a highly technique-sensitive procedure, requiring an extremely dry field prior to placement. Moisture contamination of the etched enamel surface before sealant placement is cited as the main reason for sealant failure. The purpose of this study was to evaluate the effects of different methods of sealant application on the shear bond strength of sealants to enamel. In groups 1, 2, 3, 4 Teethmate(unfilled sealant) was used, while Ultraseal XTplus(filled sealant) was used in groups 5, 6, 7, 8. Groups 1 and 5(control) were acid etched for 15 seconds using 35% phosphoric acid, washed and then dried. In groups 2, 6 drying agents were applied, and in groups 3, 7 bonding agents were applied and light cured. In groups 4 and 8 both drying agent and bonding agent were applied. Then sealant was cured to the specimen using molds 3mm in diameter and 2mm in height. Thermocycling was performed and shear bond strength was finally measured. The following results were obtained : 1. Groups using filled sealant(groups 5, 6, 7, 8) showed higher shear bond strengths compared to groups using unfilled sealant(groups 1, 2, 3, 4). 2. Among groups using unfilled sealant(groups 1, 2, 3, 4), groups 2, 3, 4 showed significantly higher shear bond strength compared to group 1(p<0.05). There were no significant differences among groups 2, 3 and 4. 3. There were no significant differences(p>0.05) among groups using filled sealant(groups 5, 6, 7, 8). 4. When modes of fracture were examined, cohesive failure was observed in groups 2, 3 and 4.

  • PDF

Facial Expression Control of 3D Avatar using Motion Data (모션 데이터를 이용한 3차원 아바타 얼굴 표정 제어)

  • Kim Sung-Ho;Jung Moon-Ryul
    • The KIPS Transactions:PartA
    • /
    • v.11A no.5
    • /
    • pp.383-390
    • /
    • 2004
  • This paper propose a method that controls facial expression of 3D avatar by having the user select a sequence of facial expressions in the space of facial expressions. And we setup its system. The space of expression is created from about 2400 frames consist of motion captured data of facial expressions. To represent the state of each expression, we use the distance matrix that represents the distances between pairs of feature points on the face. The set of distance matrices is used as the space of expressions. But this space is not such a space where one state can go to another state via the straight trajectory between them. We derive trajectories between two states from the captured set of expressions in an approximate manner. First, two states are regarded adjacent if the distance between their distance matrices is below a given threshold. Any two states are considered to have a trajectory between them If there is a sequence of adjacent states between them. It is assumed . that one states goes to another state via the shortest trajectory between them. The shortest trajectories are found by dynamic programming. The space of facial expressions, as the set of distance matrices, is multidimensional. Facial expression of 3D avatar Is controled in real time as the user navigates the space. To help this process, we visualized the space of expressions in 2D space by using the multidimensional scaling(MDS). To see how effective this system is, we had users control facial expressions of 3D avatar by using the system. As a result of that, users estimate that system is very useful to control facial expression of 3D avatar in real-time.

PROSPECTIVE CLINICAL EVALUATION OF THREE DIFFERENT BONDING SYSTEMS IN CLASS V RESIN RESTORATIONS WITH OR WITHOUT MECHANICAL RETENTION (접착제와 와동형성의 차이에 따른 5급 복합레진 수복의 전향적 임상연구)

  • Lee Kyung-Wook;Choung Sae-Joon;Han Young-Chul;Son Ho-Hyun;Um Chung-Moon;Oh Myoung-Hwan;Cho Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.4
    • /
    • pp.300-311
    • /
    • 2006
  • The purpose of this study is to evaluate prospectively the effect of different bonding systems and retention grooves on the clinical performance of resin restorations in non-carious cervical lesions (NCCLs). Thirty-nine healthy adults who had at least 2 NCCLs in their premolar areas were included in this study. One hundred and fifty teeth were equally assigned to six groups: (A) Scotchbond Multi-Purpose (SBMP, 3M ESPE, St. Paul, MN, USA, 4th generation bonding system) without retention grooves; (B) SBMP with retention grooves; (C) BC Plus (Vericom Co., Anyang, Gyeonggido, Korea, 5th generation bonding system) without retention grooves; (D) BC Plus with retention grooves; (E) Adper Prompt (3M ESPE, Seefeld, Germany, 6th generation bonding system) without retention grooves; (F) Adper Prompt with retention grooves. All cavities were filled with a hybrid composite resin. Denfil (Vericom Co., Anyang, Gyeonggido, Korea) by one operator. Restorations were evaluated at baseline and at 6-month recall, according to the modified USPHS (United States Public Health Service) criteria. Additionally, clinical photographs were taken and epoxy resin replicas were made for SEM evaluation. At 6-month recall, there were some differences in the number of alpha ratings among the experimental groups. But, despite the differences in the number of alpha ratings, there was no significant difference among the 3 adhesive systems (p < 0.05). There was also no significant difference between the groups with or without mechanical retention (p < 0.05). Follow-ups for longer periods than 6 months are needed to verify the clinical performance of different bonding systems and retention grooves.

The Studies on In Vivo Embryo Production using Sex-Sorted Sperm in Korean Brindle Cattle (성 감별 정자를 이용한 칡소 체내수정란 생산에 관한 연구)

  • Jeon, Hyang-A;Moon, Seung-Ju;Lee, Ji-Woong;Kang, Man-Jong;Sohn, Sea-Hwan;Kim, Nam-Tae;Ko, Yeoung-Gyu;Kim, Sung-Woo;Kim, Dong-Kyo;Seong, Hwan-Hoo;Cho, Young Moo;Choe, Changyong
    • Journal of Embryo Transfer
    • /
    • v.31 no.1
    • /
    • pp.47-52
    • /
    • 2016
  • The objective of this study was to investigate the result of in vivo embryo collection and pregnancy rate after embryo transfer using sex-sorted sperm of Korean brindle cattle. Donor Korean brindle cattle superovulation treated by decreasing dose of FSH injection. Embryos were recovered on 7 days after the third artificial insemination. Control group semen straw used artificial insemination contained 20 million sperm. Sex-sorted semen straws contained 4 million sperm or 10 million sperm. As for the result of the recovery of the in vivo embryos derived from sex-sorted sperm, the number of transferable embryos was significantly highly recovered to be $6.20{\pm}2.28/donor$ from the control group and was significantly lowly recovered to be $1.57{\pm}1.72/donor$ from the group treated at a sperm concentration of $10{\times}10^6$ (p<0.05). The number of unfertilized embryo was $0.8{\pm}1.30/donor$ in control group which was significantly lower than the group treated at a sperm concentration of $4{\times}10^6$ (p<0.05). However, there was no significant difference in the number of undeveloped ova between control and treatment groups. Pregnancy rate after embryo transfer was shown to be 35.00% in control group and 12.50% in treatment group. The karyotype analysis of the calf derived from sex-sorted sperm resulted in a similar chromosomal distribution pattern (2n=60, XX) compared to those of common Korean native cattle.

THE INFLUENCE OF CAVITY CONFIGURATION ON THE MICROTENSILE BOND STRENGTH BETWEEN COMPOSITE RESIN AND DENTIN (와동의 형태가 상아질과 복합레진 사이의 미세인장결합강도에 미치는 영향)

  • Kim, Ye-Mi;Park, Jeong-Won;Lee, Chan-Young;Song, Yoon-Jung;Seo, Deok-Kyu;Roh, Byoung-Duck
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.5
    • /
    • pp.472-480
    • /
    • 2008
  • This study was conducted to evaluate the influence of the C-factor on the bond strength of a 6th generation self-etching system by measuring the microtensile bond strength of four types of restorations classified by different C-factors with an identical depth of dentin. Eighty human molars were divided into four experimental groups, each of which had a C-factor of 0.25, 2, 3 or 4. Each group was then further divided into four subgroups based on the adhesive and composite resin used. The adhesives used for this study were AQ Bond Plus (Sun Medical, Japan) and XenoIII (DENTSPLY, Germany). And composite resins used were fantasists (Sun Medical, Japan) and Ceram-X mono (DENTSPLY, Germany). The results were then analyzed using one-way ANOVA, a Tukey's test, and a Pearson's correlation test and were as follows. 1. There was no significant difference among C-factor groups with the exception of groups of Xeno III and Ceram-X mono (p<0.05). 2. There was no significant difference between any of the adhesives and composite resins in groups with C-factor 0.25, 2 and 4. 3. There was no correlation between the change in C-factor and microtensile bond strength in the Fantasista groups. It was concluded that the C-factor of cavities does not have a significant effect on the microtensile bond strength of the restorations when cavities of the same depth of dentin are restored using composite resin in conjunction with the 6th generation self-etching system.

Simulation and Sensitivity Analysis of the Air Separation Unit for SNG Production Relative to Air Boosting Ratios (SNG 생산용 공기분리공정의 공기 재 압축비에 따른 민감도 분석)

  • Kim, Mi-yeong;Joo, Yong-Jin;Seo, Dong Kyun;Shin, Jugon
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.3
    • /
    • pp.173-179
    • /
    • 2019
  • Cryogenic air separation unit produces various gases such as $N_2$, $O_2$, and Ar by liquefying air. The process also varies with diverse production conditions. The one for SNG production among them has lower efficiency compared to other air separation unit because it requires ultrapure $O_2$ with purity not lower than 99.5%. Among factors that reduce the efficiency of air separation unit, power consumption due to compress air and heat duty of double column were representatives. In this study, simulation of the air separation unit for SNG production was carry out by using ASEPN PLUS. In the results of the simulation, 18.21 kg/s of at least 99.5% pure $O_2$ was produced and 33.26 MW of power was consumed. To improve the energy efficiency of air separation unit for SNG production, the sensitivity analysis for power consumption, purities and flow rate of $N_2$, $O_2$ production in the air separation unit was performed by change of air boosting ratios. The simulated model has three types of air with different pressure levels and two air boosting ratio. The air boosting ratio means flow rate ratio of air by recompressing in the process. As increasing the first air boosting ratio, $N_2$ flow rate which has purity of 99.9 mol% over increase and $O_2$ flow rate and purity decrease. As increasing the second air boosting ratio, $N_2$ flow rate which has purity of 99.9 mol% over decreases and $O_2$ flow rate increases but the purity of $O_2$ decreases. In addition, power consumption of compressing to increase in the two cases but results of heat duty in double column were different. The heat duty in double column decreases as increasing the first air boosting ratio but increases as increasing the second air boosting ratio. According to the results of the sensitivity analysis, the optimum air boosting ratios were 0.48 and 0.50 respectively and after adjusting the air boosting ratios, power consumption decreased by approximately 7% from $0.51kWh/O_2kg$ to $0.47kWh/O_2kg$.

Analysis of the Entrance Surface Dose (ESD) and Contrast Usage of Trance Femoral Cerebral Angiography (TFCA) and Cerebral Computed Tomographic Angiography (CCTA) for Cerebrovascular Disease Examining (뇌혈관 질환 검사를 위한 뇌혈관 조영술(TFCA)과 뇌혈관 전산화 단층 촬영 검사(CCTA)의 입사표면선량(ESD) 및 조영제 사용량 분석)

  • Seo, Young-Hyun;Hong, Cheon-Gi;Song, Jong-Nam
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.495-502
    • /
    • 2019
  • A typical cerebrovascular disease among cerebrovascular diseases is vascular diseases such as cerebral infarction, cerebral hemorrhage, cerebral aneurysm, cerebrovascular stenosis. If the disease occurs and causes cerebral damage, it may be difficult to recover completely. So that, Must continue to perform health care through examination early. In particular, Because most cerebrovascular disease examining use radiation equipment and Thus this study was to find out how to select about the optimal examining method and X-ray dose decrease method among different examining method though comparison and analysis for the entrance surface dose (ESD) on cerebrovascular examining with Trance Femoral Cerebral angiography (TFCA) and Cerebral Computed Tomographic Angiography (CCTA). Also, want to find out how to select about the optimal examining method for worried patient that contrast medium side effect though measuring and evaluating for contrast usage. Data were collected from 70 patients (43 males and 27 females) who underwent CCTA at Yeosoo region hospital from June 2018 to December 2018 and 61 patients (34 males and 27 females) who underwent TFCA at Pyeongtaek region hospital from June 2018 to November 2018. ESD analysis method collected retrospective data though M-view and PACS PLUS program, Used contrast usage measuring method did reality measuring method. In the analysis using SPSS, the ESD of TFCA was $245.74{\pm}71.91$, which was $32.05{\pm}7.74$ lower than the dose of $277.79{\pm}79.65$ of CCTA ESD, and statistically significant at t = 3.249, p = 0.017 (p<0.05). As a result of the comparison of the total amount of contrast agent, the mean contrast agent used in TFCA was $55.05{\pm}17.68ml$, which was about 14.95 smaller than the amount of contrast agent used in CCTA, and statistically significant t = -4.548, p<0.001. In conclusion, the ESD of TFCA was statistically significantly lower than that of CCTA, and also the used contrast usage was significantly tiny than that of CCTA. Therefore, Select the method to increase the utilization of TFCA for cerebral disease examining, we can consider X-ray dose decrease method at the same time as to decrease side effect of contrast medium.