• Title/Summary/Keyword: PLL

Search Result 951, Processing Time 0.026 seconds

Design and Fabrication of the Transceiver with 400MHz Bandwidth (400 MHz 대역의 송수신기 설계 및 제작)

  • Hur Chang-Wu;Choi Jun-Su
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.5
    • /
    • pp.851-856
    • /
    • 2006
  • This paper studies about design of a transceiver using a single PLL. The transceiver has bandwidth of $424.7\sim424.95MHz$ and the communication method used 21 channels 12.5 KHz channel bandwidth and FSK modulation/demodulation method. Also, we designed low power wireless transceiver for data transmission using a single PLL. Finally, the transceiver set achieves the following characteristics : 8.15dBm output power, 45.97dBc spurious property.

Steady-State Performance Improvement of Single-Phase PWM Inverters Using PLL Technique (PLL 기법을 이용한 단상 PWM 인버터의 정상상태 성능개선)

  • 정세교;이대식
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.356-363
    • /
    • 2004
  • This paper presents a precision voltage control technique of a single phase PWM inverter for a constant voltage and constant frequency(CVCF) applications. The proposed control scheme employs an additional phase-locked loop(PLL) compensator which is constructed using the output capacitor voltage and current. The computer simulation and experiment are carried out for the actual single-phase PWM inverter and it is well demonstrated from these results that the steady-state performance and total harmonic distortion(THD) are remarkably improved by employing the proposed technique.

Effects of Polymerized Basic Amino Acids Under 50mer Range of Degree of Polymerization on Physiological and Stimulated Mucin Release from Cultured Hamster Tracheal Surface Epithelial Cells (중합도 50mer 이하의 염기성 아미노산 중합체들이 일차배양 햄스터 기관표면 상피세포에서의 생리적 뮤신유리 및 분비자극 상태에서의 뮤신유리에 미치는 영향)

  • 이충재;이재흔;석정호;허강민
    • Biomolecules & Therapeutics
    • /
    • v.10 no.3
    • /
    • pp.156-164
    • /
    • 2002
  • In the present study, we tried to investigate whether polymerized basic amino acid e.g. poly-L-lysine (PLL) which has the degree of polymerization under 50mer significantly affects the physiological and stimulated mucin release from cultured hamster tracheal surface epithelial cells. Confluent primary hamster tracheal surface epithelial (HTSE) cells were metabolically radiolabeled with $^3{H}$-glucosamine for 24 hr and chased for 30 min in the presence of either PLLs or adenosine triphosphate (ATP) and PLL to assess the effects on basic or ATP-stimulated $^3{H}$-mucin release. Possible cytotoxicities of PLLs were assessed by measuring lactate dehydrogenase (LDH) release from HTSE cel1s during treatment. The results were as follows: PLLs significantly inhibited basic mucin release from cultured HTSE cells in a dose-dependent manner from the range of 46mer to 14mer; PLL 46mer significantly inhibited the stimulated mucin release by ATP from cultured HTSE cells; there was no significant release of LDH from cultured HTSE cells during treatment. We conclude that PLLs inhibit both physiological and stimulated mucin release from airway epithelial cells without significant cytotoxicity and PLL lost its activity under the range of 14mer. This finding suggests that polymer of basic amino acid like PLL might function as a regulator for hypersecretion of mucus manifested in various respiratory diseases.

A Study on the Phase Locked Loop Macromodel for PSPICE (PSPICE에 사용되는 위상동기루프 매크로모델에 관한 연구)

  • 김경월;김학선;홍신남;이형재
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.9
    • /
    • pp.1692-1701
    • /
    • 1994
  • Macromodeling technology is useful to simulate and analyze the performance of new elements and complicated circuits or systems without any changes in today's general simulator, PSPICE. In this paper, Phase Locked Loop(PLL) is designed using macromodeling technique. The PLL macromodel has two basic sub-macromodels of the phase detector and the voltage controlled oscillator(VCO). The PLL macromodel has two open terminals for inserting RC low pass filter. The PLL macromodel is simulated using simulation parameters of LM565CN manufactured in the National company. At a free-running frequency, 2500Hz, upper lock range and lower capture range was 437Hz, 563Hz, respectively. Also, experimental results and simulation results of LM565CN PLL show good agreement.

  • PDF

Liquid Crystal Based Optical Sensor for Imaging Trypsin Activity at Interfaces Between Aqueous Phases and Thermotropic Liquid Crystals

  • Zhang, Minmin;Jang, Chang-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.10
    • /
    • pp.2973-2977
    • /
    • 2013
  • In this study, we developed a liquid crystal (LC)-based optical sensor for monitoring enzymatic activity through orientational changes in liquid crystals (LCs) coupled to the properties of a poly-${\small{L}}$-lysine (PLL)-based polymeric membrane. We prepared a PLL-based polymeric membrane at the planar interface between the thermotropic liquid crystal and aqueous phases. The PLL-based polymeric membrane was obtained by contacting the PLL solution with water immiscible LCs, 4-cyano-4'-pentyl-biphenyl (5CB) doped with adipoyl chloride. We then investigated the membrane properties by examining the permeability of the membrane to phospholipids, 1,2-didodecanoyl-rac-glycero-3-phosphocholine (DLPC). The permeability of the membrane to transport phospholipids was monitored through the orientational transition of 5CB in contact with the dispersions of DLPC. Since trypsin can enzymatically catalyze the hydrolysis of PLL, we incubated an aqueous trypsin solution with the membrane for 2 h at room temperature to cause an increase in the permeability of the polymeric membrane to DLPC. As a result, a bright to dark optical shift of LCs was observed, which implied that an enzymatic reaction between trypsin and PLL-based membrane occurred. Two control experiments using chymotrypsin and bovine serum albumin (BSA) revealed no sign of improved permeability based on the orientational transition of LCs.

Converter Control for APU of 8200 Series Electric Locomotive using Advanced Single Phase PLL Control Method (진보된 단상 PLL 제어방법을 이용한 8200호대 전기기관차 보조전원장치용 컨버터 제어)

  • Jung, No-Geon;Lee, Eul-Jae;Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.1
    • /
    • pp.211-215
    • /
    • 2017
  • The APF (All Pass Filter) method that utilizes the computational power of the controller is most commonly used. However, since the calculation of the filter coefficient is complicated, the calculation is carried out in advance. It is difficult to apply it to the frequency fluctuation environment because the coefficient value is fixed. In this paper, a new control method of single phase PLL that can be usefully used in PWM converter device for electric railway was explained. Comparison and examination of similarities and differences between the conventional APF method PLL controller method and the newly proposed modified MA filter method PLL technique were performed. The possibility of implementation of the modified MA filter method through computer simulation was analyzed. In conclusion, the method proposed as the conclusion was applied to the APU(Auxiliary Power System) of 8200 Series Electric Locomotive and its usefulness was confirmed.

A Hybrid Filtering Stage Based Quasi-type-1 PLL under Distorted Grid Conditions

  • Li, Yunlu;Wang, Dazhi;Han, Wei;Sun, Zhenao;Yuan, Tianqing
    • Journal of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.704-715
    • /
    • 2017
  • For three-phase synchronization applications, the synchronous reference frame phase-locked loop (SRF-PLL) is probably the most widely used technique due to its ease of implementation and satisfactory phase tracking performance under ideal grid conditions. However, under unbalanced and distorted grid conditions, its performance tends to worsen. To deal with this problem, a variety of filtering stages have been proposed and used in SRF-PLLs for the rejection of disturbance components at the cost of degrading the dynamic performance. In this paper, to improve dynamic performance without compromising the filtering capability, an effective hybrid filtering stage is proposed and incorporated into the inner loop of a quasi-type-1 PLL (QT1-PLL). The proposed filtering stage is a combination of a moving average filter (MAF) and a modified delay signal cancellation (DSC) operator in cascade. The time delay caused by the proposed filtering stage is smaller than that in the conventional MAF-based and DSC-based PLLs. A small-signal model of the proposed PLL is derived. The stability is analyzed and parameters design guidelines are given. The effectiveness of the proposed PLL is confirmed through experimental results.

Design of the Charge pump PLL using Dual PFD (듀얼 위상 주파수 검출기를 이용한 차지펌프 PLL 설계)

  • Lee, Jun-Ho;Lee, Geun-Ho;Son, Ju-Ho;Kim, Sun-Hong;Yu, Young-Gyu;Kim, Dong-Yong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.8
    • /
    • pp.20-26
    • /
    • 2001
  • In this paper, the charge pump PLL using the dual PFD to improve the trade-off between acquisition behavior and locked behavior is proposed. This dual PFD consists of a positive edge triggered PFD and a negative edge triggered PFD. The proposed charge pump shows that it is possible to overcome the issue of the charge pump current imsmatch by the current subtraction circuit. Also, this charge pump can suppress reference spurs and disturbance of the VCO control voltage. The proposed charge pump PLL is simulated by SPICE using 0.25${\mu}m$ CMOS process parameters.

  • PDF

Novel 10 GHz Bio-Radar System Based on Frequency Multiplier and Phase-Locked Loop (주파수 체배기와 PLL을 이용한 10 GHz 생체 신호 레이더 시스템)

  • Myoung, Seong-Sik;An, Yong-Jun;Moon, Jun-Ho;Jang, Byung-Jun;Yook, Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.2
    • /
    • pp.208-217
    • /
    • 2010
  • This paper presents a novel 10 GHz bio-radar system based on a frequency multiplier and phase-locked loop(PLL) for non-contact measurement of heartbeat and respiration rates. In this paper, a 2.5 GHz voltage controlled oscillator (VCO) with PLL is employed to as a frequency synthesizer, and 10 GHz continuous wave(CW) signal is generated by using frequency multiplier from 2.5 GHz signal. This paper also presents the noise characteristic of the proposed system. As a result, a better performance and economical frequency synthesizer can be achieved with the proposed bio-radar system. The experimental results shows excellent bio-signal measurement up to 100 cm without any additional digital signal processing(DSP), and the proposed system is validated.

Design of Ku-Band Phase Locked Harmonic Oscillator (Ku-Band용 위상 고정 고조파 발진기 설계)

  • Lee Kun-Joon;Kim Young-Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.1 s.92
    • /
    • pp.49-55
    • /
    • 2005
  • In this paper, the phase locked harmonic oscillator(PLHO) using the analog PLL(Phase Locked Loop) is designed and implemented for a wireless LAN system. The harmonic oscillator is consisted of a ring resonator, a varactor diode and a PLL circuit. Because the fundamental fiequency of 8.5 GHz is used as the feedback signal for the PLL and the 2nd harmonic of 17.0 GHz is used as the output, a analog frequency divider for the phase comparison in the PLL system can be omitted. For the simple PLL circuit, the SPD(Sampling Phase Detector) as a phase comparator is used. The output power of the phase locked harmonic oscillator is 2.23 dBm at 17 GHz. The fundamental and 3rd harmonic suppressions are -31.5 dBc and -29.0 dBc, respectively. The measured phase noise characteristics are -87.6 dBc/Hz and -95.4 dBc/Hz at the of offset frequency of 1 kHz and 10 kHz from the carrier, respectively.