• Title/Summary/Keyword: PLF

Search Result 51, Processing Time 0.03 seconds

Comparison of the Characteristics of Three Premium Large-Format Platforms IMAX, Screen X and 360 Degrees Circular Screen (PLF 플랫폼 아이맥스, 스크린 X, 360도 서큘러 스크린의 특징 비교 연구)

  • Shan, Xinyi;Chung, Jean-Hun
    • Journal of Digital Convergence
    • /
    • v.15 no.8
    • /
    • pp.375-381
    • /
    • 2017
  • The America film, Beauty and Beast has grossed over 4,273,401 after being released for 21 days. The growth of movie profit in the video market is also developing rapidly. In this paper, we will focus on the PLF(Premium Large-Format) video technology, because PLF video technology can help audience to enhance the sense of 'immersion' and enjoy a different visual feast. In PLF video technology, IMAX, screen X, 360 degrees circular screen are the most important formats. By comparative analysis of these 3 formats, the biggest difference is their number of screens and appearance. Based on the result we can understand the 3 kinds of PLF platforms better and help us to make a choice between them. In addition, further research about the manufacture method of PLF technology will be discussed.

Structural test of KSLV-I Payload fairing (KSLV-I 페이로드 페어링 구조시험)

  • Lee, Jong-Woong;Kong, Cheol-Won;Eun, Se-Won;Nam, Gi-Won;Jang, Young-Soon;Shim, Jae-Yeul;Lee, Young-Shin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.11
    • /
    • pp.900-907
    • /
    • 2013
  • Payload fairing(PLF) protects satellites and related equipment from the external environment. They are separated before the satellite separation. Payload fairing made of composite sandwich materials due to their considerable bending stiffness and strength-to-weight ratio. Payload fairing have compression, shear and bending load during the flight. In this study, To check the strength of PLF and connected part, structural test of PLF accomplished using an actuator and a fixture. Purpose of structural test is to verify the strength of PLF in force of separation spring and combination structural load applied. Test result shows that the PLF have an acceptable margin of safety for the combination structural load and force of separation spring.

Acoustic Test of KSLV-I PLF Acoustic Protection System (KSLV-I PLF 음향 하중 저감 시스템의 성능 검증을 위한 음향 시험)

  • Park, Soon-Hong;Seo, Sang-Hyeon
    • Aerospace Engineering and Technology
    • /
    • v.7 no.2
    • /
    • pp.117-122
    • /
    • 2008
  • Acoustic test was performed to verify the ability of KSLV-I PLF acoustic protection system (Acoustic blanket) to reduce the acoustic load. The test results showed that the acoustic protection system has +3 dB safety margin compared with design requirement. This paper also illustrates the increase of insertion loss by the acoustic protection system by comparing that of the bare PLF structure.

  • PDF

Effects of Piperis Longi Fructus on Regulatory T Cells Number, IgE, Histamine Production in Asthma Model Mice and Th1/Th2 Cytokine Balance in vitro (천식 모델 생쥐에서 필발이 CD25+T 세포수, IgE, Histamine 생성량과 in vitro에서 Th1/Th2 Cytokine Balance에 미치는 영향)

  • Lee, Young-Cheol;Kim, Seung-Hyung
    • The Korea Journal of Herbology
    • /
    • v.24 no.1
    • /
    • pp.79-88
    • /
    • 2009
  • Objectives : It has been recently shown that Piperis Longi Fructus (PLF) is involved in the reduction of eosinophil recruitment and production of Th2 cytokines in vivo. However, the main therapeutic mechanisms of PLF remains a matter of considerable debate. To investigate the therapeutic mechanisms of PLF, we examined the influence of PLF on regulatory T cells number, IgE, histamine production in vivo and Th1/Th2 cytokine balance in vitro. Methods : All mice were immunized on two different days (21 days and 7 days before inhalational exposure) by i.p. injections of 0.2 $m\ell$ alum-precipitated Ag containing 100 ${\mu}g$ of OVA bound to 4 mg of aluminum hydroxide in PBS. Seven days after the second sensitization, mice were exposed to aerosolized ovalbumin for 30 min/day on 3 days/week for 12 weeks(at a flow rate of 250 L/min, 2.5% ovalbumin in normal saline) and PLF (150 mg/kg) were orally administered 3 times a week for 8 weeks. Splenocytes from C57BL/6 mice at 8 weeks of age were stimulated with anti-CD3 (1 mg/ml) plus anti-CD28 (1 mg/ml) antibody for 48hrs. IL-4 and IFN-$\gamma$ in the culture supernatants were measured by ELISA Results : The suppressive effects of PLF on asthma model were demonstrated by the increase the number of regulatory T cells and by reducing IgE, histamine production in vivo and modulation of Th1/Th2 cytokine balance. Conclusions : These results indicate that PLF has a deep inhibitory effects on asthma model mice by increase the number of regulatory T cells, and by reducing IgE, histamine production.

Comparative Study of the Flight Test Data and the Prediction Results of PLF Temperature of KSLV-I Using CFD (전산유동해석 기법을 이용한 KSLV-I PLF 구조물 온도 해석 및 비행시험 자료 비교)

  • Kim, Young-Hoon;Ok, Ho-Nam;Kim, In-Sun
    • Aerospace Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.35-41
    • /
    • 2010
  • The temperature of the flight objects in high speed increases due to the aerodynamic heating. MINIVER and CFD approach are used to predict the aerodynamic heating conditions of KSLV-I. MINIVER is based on the empirical method. And the CFD approach predicts the aerodynamic heating conditions after the analysis of the surface temperature and the surface heat flux directly. In this study, the aerodynamic heating conditions using CFD approach are considered. The PLF temperature for these aerodynamic heating conditions is compared with the flight test data of KSLV-I.

Posterior Thoracic Cage Interbody Fusion Offers Solid Bone Fusion with Sagittal Alignment Preservation for Decompression and Fusion Surgery in Lower Thoracic and Thoracolumbar Spine

  • Shin, Hong Kyung;Kim, Moinay;Oh, Sun Kyu;Choi, Il;Seo, Dong Kwang;Park, Jin Hoon;Roh, Sung Woo;Jeon, Sang Ryong
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.6
    • /
    • pp.922-932
    • /
    • 2021
  • Objective : It is challenging to make solid fusion by posterior screw fixation and laminectomy with posterolateral fusion (PLF) in thoracic and thoracolumbar (TL) diseases. In this study, we report our experience and follow-up results with a new surgical technique entitled posterior thoracic cage interbody fusion (PTCIF) for thoracic and TL spine in comparison with conventional PLF. Methods : After institutional review board approval, a total of 57 patients who underwent PTCIF (n=30) and conventional PLF (n=27) for decompression and fusion in thoracic and TL spine between 2004 and 2019 were analyzed. Clinical outcomes and radiological parameters, including bone fusion, regional Cobb angle, and proximal junctional Cobb angle, were evaluated. Results : In PTCIF and conventional PLF, the mean age was 61.2 and 58.2 years (p=0.46), and the numbers of levels fused were 2.8 and 3.1 (p=0.46), respectively. Every patient showed functional improvement except one case of PTCIF. Postoperative hematoma as a perioperative complication occurred in one and three cases, respectively. The mean difference in the regional Cobb angle immediately after surgery compared with that of the last follow-up was 1.4° in PTCIF and 7.6° in conventional PLF (p=0.003), respectively. The mean durations of postoperative follow-up were 35.6 months in PTCIF and 37.3 months in conventional PLF (p=0.86). Conclusion : PTCIF is an effective fusion method in decompression and fixation surgery with good clinical outcomes for various spinal diseases in the thoracic and TL spine. It provides more stable bone fusion than conventional PLF by anterior column support.

Study of PLF-Prism sheet combination photo-luminescent film and prism sheet in blue LED BLU (청색 LED BLU에서 결합된 광 여기필름과 프리즘 시트의 연구)

  • Kim, Du-Hui;Im, Yeong-Rak;HwangBo, Chang-Gwon
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2008.07a
    • /
    • pp.449-450
    • /
    • 2008
  • 본 연구에서 우리는 4축 회전이 가능한 휘도측정기를 가지고 확산판 대신, PLF를 사용한 edge형 BLU의 광시야각, 휘도 및 스펙트럼을 측정하였다. 이에 따라, 우리는 조명설계 프로그램 'LightTools'을 이용하여 PLF와 프리즘 시트가 최적화 되도록 설계하여 분석하였다.

  • PDF

Pyroshock Prediction of the Satellite Launch Vehicle at the Payload Fairing Separation (인공위성 발사체 노즈페어링 분리 시 구조물의 충격량 예측)

  • Jeong, Ho-Kyeong;Youn, Se-Hyun;Park, Soon-Hong;Jang, Young-Soon;Lee, Yeoung-Moo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.250-253
    • /
    • 2005
  • This paper is investigates the separation shock of payload fairing. Separation test of subscale PLF using half separation device and half PLA is performed. Resulting shock loads at equipment bay and fairing joint are measured. Pyroshock estimation is performed using AUTOSEA Pyroshock Module. Input data to analysis model is obtained from the separation test results of subscale PLF. And model of AUTOSEA is updated comparing results between tests and analysis.. This enables us to validate the AUTOSEA model. Tuned model of subscale PLF and separation device is used to update full scale model, and the shock analysis result of full scale model is estimated in this paper. This paper also discusses the results regarding the difficulty of structural modeling and its numerical implementation in AutoSEA2 Software.

  • PDF

New Light Fiber BLU System for Large LCD Display

  • Chung, Man-Young;Park, Tong-Soo
    • Proceedings of the IEEK Conference
    • /
    • 2002.07c
    • /
    • pp.1398-1400
    • /
    • 2002
  • A new PLF-BLU (Plastic Light Fiber-Back Light Unit) using side glowing light fiber rods array for the 42" LCD TV display has been evelopedd. The light fibers were 14mm in diameter and 50cm long pure transparent acrylic rods of 1.49 refractive index. Fine seratees were made on the flat side of rod. extremely bright incandscent light from lamp fed into the fiber si scattered at scratches then emerges through the surface of rod. A typical PLF-BLU system consists of 24 PLFs produced side glow of brightness of 4,500cd/㎡ to 6,500cd/㎡. New PLF-BLU is proved to be a BLU of rigid, bright, no heat generation, and low power consumption, hence a prospective BLU system for very and/or ultra large size TVs. A new LED-PLF-BLU system considered to be a revolutionary to break-through of the BLU technologies has also been developed, and is decribed briefly.

  • PDF

Large Deformation Analysis of Nonlinear Beam Element Based on Pseudo Lagrangian Formulation (Pseudo Lagrangian방법(方法)에 의한 비선형(非線型) 보요소(要素)의 대변형(大變形) 해석(解析))

  • Shin, Young Shik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.10 no.3
    • /
    • pp.29-38
    • /
    • 1990
  • A totally, new approach of Lagrangian formulation named 'Pseudo Lagrangian Formulation(PLF)' for large deformation analysis of continue and structures by the finite of element method has been presented, and the efficiency and accuracy of nonlinear analysis beam element formulated by PLF has been discussed by solving several numerical examples. In PLF, the deformation of a body is maeasured by assigning a nonphysical 'Pseudo' configuration as reference. The Lagrangian deformation and the finite element mapping of the traditonal Lagrangian approaches are then carried out directly at the same time, The result of numerical tests shows superior performance of PLF to the traditional Lagrangian methods, Applications of PLF to small and finite deformation problems indicate that PLF not only serves as an alternative but has certain implementational advantages over total or updated Lagrangian formulations.

  • PDF