• Title/Summary/Keyword: PLC-based Interface

Search Result 56, Processing Time 0.028 seconds

Firmware and UI for Power Line Communication Based Public Address System (전력선 통신 기반 전관 방송시스템의 펌웨어와 UI)

  • Kim, Seok;Kim, Dae-Ik
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.1
    • /
    • pp.127-136
    • /
    • 2019
  • The public address system should be easily operated and managed by the users, and guaranteed to serve stable working in an emergency and a crisis. In this paper, In this paper, to provide power line communication based public address system users with convenience and efficiency, we implement a firmware to control communication between a PLC(: Power Line Communication) controller of the public address system and UI(: User Interface) and between a PLC controller of the public address system and PLC speakers, and develop a UI software.

System Design of High-Definition Media Transceiver based on Power Line Communication and Its Performance Analysis (전력선 통신 기반 HD급 미디어 전송 시스템 설계 및 성능 분석)

  • Kim, Ji-Hyoung;Kim, Kwan-Woong;Kim, Yong-K.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.1
    • /
    • pp.192-196
    • /
    • 2010
  • Due to a development of a modem technology as Power Line Communication(PLC) over 200 Mbps, the high-speed multi-media data trasmission could be currently possible. The strength of the PLC has no more additional wiring work. PLC has also possible to high quality data transmission with currently electrical cable. It has a various strong point campare with existing wire and wireless communication technologies. In This paper we develop a high quality media transmitter-receiver based on merging the HomePlug AV, which is 200 Mbps class PLC technology and HDMI Interface technology. The video function was used for the VEDEO TEST GENERATOR in order to a property valuation. Smart Live 6 software were used for the assessment of audio property. As the result of measurement of the HD class images by capturing from the receiver of the PLC, the quality of images couldn't be confirm any deterioration, which has compared with original reflections. In case of audio part as the result of confirmation of the Phase, Magnitude, it has been confirmed that over 90% of nomal transmition and receiving of acoustic signal. It can be possible to have HD class Media service through the PLC.

Protocol Monitor System Between Cortex M7 Based PLC And HMI

  • Kim, Ki-Su;Lee, Jong-Chan;Ha, Heon-Seong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.6
    • /
    • pp.17-23
    • /
    • 2020
  • In this paper, collecting real-time data frames that occur during RS232 communication between an HMI and PLC of automation equipment by sniffing real-time information data frames through MCU without modification of the HMI or PLC, a method is proposed that allows users to collect data without being dependent on the modification of PLC and HMI systems. The user collects necessary information from the sniffing data through the parsing operation, and the original communication interface is maintained by transmitting the corresponding sniffing frame to the destination. The MCU's UART communication interface circuit is physically designed according to the RS232 communication standard, and this additionally improves efficiency more so than an interrupt-based system by using the DMA device inside the MCU. In addition, the data frame IO operation is performed by logically separating the work of the DMA interrupt service routine from the work of the main thread using the circular queue. Through this method, the user receives the sniffing data frame between the HMI and PLC in RS232 format, and the frame transfer between PLC and HMI arrives normally at the original destination. By sniffing the data frame without further modification of the PLC and HMI, it can be confirmed that it arrives at the user system normally.

Development of Programmable Logic Controller-Based Supervisory System for Group Production Machine (그룹 생산설비에 대한 PLC 기반 감시시스템 개발)

  • Cho, Yongsik;Ahn, Junghwan
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.1
    • /
    • pp.15-20
    • /
    • 2014
  • The manufacturing equipment on most shop floors consists of numerical control machines, and the condition of each piece of equipment is monitored and controlled by an internal sensor or programmable logic controller (PLC). To control and monitor production lines that consist of an equipment or production module, a separate control and monitoring system such as a manufacturing execution system should be introduced. However, there is no standardized system, and it is costly and difficult to build a system for small or medium-sized plants. In this paper, a PLC-based supervisory system for operation control of a group of production machines is proposed, and the developed PLC-based system is evaluated by applying it to a computer numerical control machine.

Internet-Based Remote Control System Using Power Line Communication (전력선 통신을 이용한 인터넷 기반 원격 제어 시스템)

  • 차주헌;전희연;김재덕;김근영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.523-528
    • /
    • 2001
  • In this paper, we describe the internet-based remote home automation system that con control and manage home appliances or digital devices bi-directionally through Internet. The platform-independency of VRML and Java applet enables users to access their home appliances and to check current state of them in t he virtual reality environment. The main focus is on three aspects. One is on the virtual reality technology to support the user interface efficiently by using 3D GUI in web-browser. Another is on the system architecture that consists of Home server and its manager server called Gate server in this paper. These servers have been implemented by Java RMI which is the basic single programming interface for distribution of objects and services using Java technology. The third, remote PLC controller and each digital devices are composed of home networking by PLC using CEBus protocol.

  • PDF

Development of Machine Vision System based on PLC (PLC 기반 머신 비전 시스템 개발)

  • Lee, Sang-Back;Park, Tae-Hyoung;Han, Kyung-Sik
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.7
    • /
    • pp.741-749
    • /
    • 2014
  • This paper proposes a machine vision module for PLCs (Programmable Logic Controllers). PLC is the industrial controller most widely used in factory automation system. However most of the machine vision systems are based on PC (Personal Computer). The machine vision system embedded in PLC is required to reduce the cost and improve the convenience of implementation. In this paper, we newly propose a machine vision module based on PLC. The image processing libraries are implemented and integrated with the PLC programming tool. In order to interface the libraries with ladder programming, the ladder instruction set was also designed for each vision library. By use of the developed system, PLC users can implement vision systems easily by ladder programming. The developed system was applied to sample inspection system to verify the performance. The experimental results show that the proposed system can reduce the cost of installing as well as increase the ease-of-implementation.

Design of HMI software Interoperable with OPC-DA Server (OPC Server와 연동되는 HMI 소프트웨어 설계)

  • Cha, Jae-Pil;Jang, Dong-Wook;Jo, Sang-Hyun;Sun, Bok-Keun;Kim, Su-Hee;Han, Kwang-Rok
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.801-802
    • /
    • 2006
  • The present study purposes to develop HMI software that runs on Windows CE .NET platform without being bound to specific HMI equipment and accesses data in PLC equipment through interoperation with an OPC-DA server. As the OPC-DA server reads data in PLC equipment, HMI system does not need to be configured differently for different equipments. In addition, when the interface environment of specific equipment changes, it does not require the application of new equipment or the change of communication protocol. As HMI system runs on Windows CE .NET platform, it can be configured using common embedded devices based on Windows CE .NET platform. HMI software reads data in PLC equipment through RS-232C communication interface. In addition, because it connects to an OPC-DA server through Ethernet communication interface, it can access data in PLC equipment as long as Ethernet is usable.

  • PDF

The Mold Close and Open Control of Injection Molding Machine Using Fuzzy Algorithm

  • Park, Jin-Hyun;Lee, Young-Kwan;Kim, Hun-Mo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.575-579
    • /
    • 2005
  • In this paper, the development of an IMM(Injection Molding Machine) controller is discussed. Presently, the Mold Close and Open Control Method of a toggle-type IMM is open-loop control. Through the development, a PC based control system was built instead of an existing controller and a closed-loop control replaced the previous control method by using PC based PLC. To control the nonlinear system of toggle type clamping unit, a fuzzy PI control algorithm was selected and it was programmed by an IL(Instruction List) and a LD(Ladder Diagram) on a PC based PLC. The application of fuzzy algorithm as the control method was also considered to change a control object like a mold replacement or an additional apparatus. For the development of an IMM controller, PC based PLC of PCI card type, distributed I/O modules with CANopen and Industrial PC and HMI (Human Machine Interface) software were used.

  • PDF

Implementation of Exposure Stage Integrated Control System for FPD (FPD용 노광 스테이지의 통합 제어시스템 구현)

  • Kim, Jong-Won;Seo, Jae-Yong;Cho, Hyun-Chan;Cho, Tai-Hoon;Kang, Heung-Seok
    • Journal of the Semiconductor & Display Technology
    • /
    • v.5 no.4 s.17
    • /
    • pp.11-15
    • /
    • 2006
  • Expose equipment system that is used for manufacturing process of Flat Panel Display, is most important equipment in whole process. Expose equipment that is for making pattern of mask on substrate, consists of optical part, stage part and transport part. The stage is an important part that aligns mask and substrate for delivering pattern of mask to substrate exactly. In this paper, control system of expose stage that is able to use mask and substrate of diverse size, with PC controller using GUI interface instead of PLC control system. The existing PLC control system does not have the suitable structure for using mask of diverse size. GUI interface integration control system is based on PC. So it has the advantage of convenient use and active operation. We embodied PLC control system in integration control system based on PC, and verified utility possibility through the standard test course.

  • PDF

Implementation of Integrated Interface based on Wire and Wireless Dual Network for Ensuring the Reliability of Intelligent LED Lighting System (지능형 LED 조명 시스템의 신뢰성 확보를 위한 유무선 이중망 통합 인터페이스 구현)

  • Lee, Un-Seon;Park, Tae-Jin;Park, Man-Gon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.2
    • /
    • pp.306-312
    • /
    • 2014
  • The ZigBee communication method, which is the most frequently applied to the LED lighting control system, has drawbacks of low-speed and low-capacity, and the communication failure possibility due to environmental influences is on the rise. Therefore, it is important to secure the communication reliability by applying an integrated interface with a wire-wireless dual-network. This paper developed a communication module, which has a platform converging and combining the ZigBee of USN environments with the PLC of power line communication environments, to implement a dualized communication interface system supporting the wire-wireless integrated protocol, and implemented a wire-wireless networking device and a control system software technology. As a result, it was automatically switched into the PLC communication within 4.4 seconds on average when there was an access failure in the ZigBee communication network, so a reliable communication network was built.