• Title/Summary/Keyword: PLC modem

Search Result 70, Processing Time 0.036 seconds

Monitoring System with PLC I/O for Car Parking Lot (Car Parking Lot 모니터링 시스템)

  • Lee, Seong-Jae;Kim, Jae-Yang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.511-512
    • /
    • 2007
  • The monitoring system has won acceptance as a premium mark that identifies the highest standard of product quality in advanced industry. The TOP features with multi-I/O ports and VGA & RCA TV-out ports supporting mirroring & multiple dual-display modes by windows 0/5. With the choice of versatile stands, panel mount, or VESA wall-mount swing arm and connecting to modem. Wireless keyboard, Customer Display and Card Reader, is your idea Panel system for the application of TOP(Touch Operation Pannel), KIOSK, or Office / Factory Automation. TOP is the hardware and software product that transacts all kind of functions for advanced technology equipment to button, switch, voice and graph etc so that let consumer use easily Industrial HMI System Touch Panel. System characteristics: Easy of use and flexibility to the user, Present a high value solution and advanced function for many Application, Factory Automation, Office Automation, Building Automation System, Information Service System, etc. Analog Touch - 2MB Flash Memory for Saving Screen Data - RS-232C/422 Serial Port - Multi Language Support.

  • PDF

A Study on Implementation of Powerline Carrier Modem using 5-ary Frequency Shift Keying Method (5-ary 주파수 천이 키잉 방식을 이용한 전력선 캐리어 모뎀 구현에 관한 연구)

  • Park, Sung-Wook;Park, Jong-Wook
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.42 no.3
    • /
    • pp.39-44
    • /
    • 2005
  • In this paper, we use the 5-ary frequency shift keying method for robust powerline communication. To transmit the data by the 3-ary carrires among 5-ary carrirers and three carriers are 115kHz, 120kHz and 125kHz. Each time of three carrires is 0.33ms and total transmitting time duration from zero crossing point has 1ms. We use the dummy carriers which are 50kHz and 350kHz for monitoring the powerline channel state, dummy signal duration is received during 1ms. Experimentation result is shown that the implemented PLC transceiver has better than chirp transceiver at the capacitive load testing in spite of low transmission power.

Performance analysis of legacy line communication using high current powerlines in midrange wind turbines (중형급 풍력 발전기내 전력선을 이용한 무배선 통신 성능분석)

  • Kim, Kyoung-Hwa;Jeong, Seong-Uk;Nam, Seung-Yun;Kim, Hyun-Sik;Sohn, Kyung-Rak
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.4
    • /
    • pp.336-341
    • /
    • 2016
  • This paper presents an implementation of a communication network in wind turbines, which exploits the power-line communication system (PLC). We used an inductive coupling unit and a multi-interface device to connect a data-communication terminal to the power line, to ensure that stable communication was possible at various electric current and voltage values of the generator. The results of the operation tests conducted on an operational wind turbine showed that the implemented PLC demonstrated a transmission rate of at least 43 Mbps with a 100% success rate. Moreover, a real-time image was transmitted. Thus, the system could be a useful alternative for implementing a communication network in wind turbines that does not require additional channels. Since the presented system is easy to implement, and can support various interfaces for data communication, it will be quite useful when a real-time monitoring system is launched in wind turbines.

Home Network Control Protocol for Networked Home Appliances and Its Application

  • Lee Jae-Min;Myoung Kwan-Joo;Kim Dong-Sung;Kwon Wook-Hyun;Ko Beom-Seog;Kim Young-Man;Kim Yo-Hee
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.1 no.1
    • /
    • pp.26-39
    • /
    • 2002
  • This paper describes design and implementation of home network control protocol for networked home appliances. The proposed network protocol has four-layered protocol structure and device-modem interface structure for the flexibility of modems based on power line communication. The standard message set is specified to guarantee the interoperability between various home appliances The proposed protocol can be easily implemented because it has minimum network overhead.

  • PDF

A Study on the wired&wireless Bridge modem development for AMI (다양한 환경의 AMI 구성을 위한 유무선 네트워크를 지원하는 브릿지 모뎀 개발 사례)

  • Han, Jeong Hoon;Kim, Yong Bae;Kim, Beom Joo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2016.10a
    • /
    • pp.781-782
    • /
    • 2016
  • 본 논문은 스마트그리드 중요 인프라인 AMI 시스템 성능 제고를 위해 다양한 환경에서의 원격검침이 가능한 솔루션 개발에 있어 통신환경 등을 고려하였을 때 다양한 통신기술에 맞춰 원격검침 서비스를 제공할 수 있는 복합 브릿지 모뎀의 개발 사례를 다루고자 한다. 유무선 복합 기술을 적용하기 위해 TVWS 대역 무선 통신, 저속 PLC를 복합적으로 적용하였다. 본 개발 모뎀은 현재 시작품 형태로 제작이 되어 있으며, 현재 진행 중인 연구가 완료되는 시점에는 제품수준의 복합 모뎀이 산출될 예정이다.

Implementation of Intelligent Home Network and u-Healthcare System based on Smart-Grid

  • Kim, Tae Yeun;Bae, Sang Hyun
    • Journal of Integrative Natural Science
    • /
    • v.9 no.3
    • /
    • pp.199-205
    • /
    • 2016
  • In this paper, we established ZIGBEE home network and combined smart-grid and u-Healthcare system. We assisted for amount of electricity management of household by interlocking home devices of wireless sensor, PLC modem, DCU and realized smart grid and u-Healthcare at the same time by verifying body heat, pulse, blood pressure change and proceeded living body signal by using SVM algorithm and variety of ZIGBEE network channel and enabled it to check real-time through IHD which is developed by user interface. In addition, we minimized the rate of energy consumption of each sensor node when living body signal is processed and realized Query Processor which is able to optimize accuracy and speed of query. We were able to check the result that is accuracy of classification 0.848 which is less accounting for average 17.9% of storage more than the real input data by using Mjoin, multiple query process and SVM algorithm.

Development of Time Information Broadcasting System using Power Line Communication (전력선 통신을 이용한 시각 방송 시스템 개발)

  • Na, Dong-Ho;Ryu, Dae-Hyun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.1
    • /
    • pp.217-223
    • /
    • 2012
  • Time synchronization problems is very important in everyday life and a variety of industries, In this paper, we developed PLB(Power Line Broadcasting) system which broadcast time information to each device through power line modems. In our system, the smartphone synchronized to GPS time is used as a time source and we propose, develop and evaluate a relay system to solve the difficulties of long-distance transmission of power line modem technology.

Development of Reefer Container Real-time Management System (실시간 냉동컨테이너 관리 시스템 개발)

  • Choi, Sung-Pill;Jung, Jun-Woo;Moon, Young-Sik;Kim, Tae-Hoon;Lee, Byung-Ha;Kim, Jae-Joong;Choi, Hyung-Lim;Lee, Eun-Kyu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.12
    • /
    • pp.2917-2923
    • /
    • 2015
  • In spite of a recent trend of container ships becoming larger in size, the current circumstance is that managing reefer containers marine transportation is being mostly dependent upon manpower. Particularly, in the case of bad weather or nighttime, reefer containers are not being monitored due to lack of safety device. For the purpose of reducing such risk, IMO is recommending a system using PLC but the system is not being used. In addition, they are still relying on manpower for control and reliability of freight in transit is decreasing due to lack of information during marine transportation for every subject related to freight as well as shipper. Accordingly, the purpose of this paper is to propose a real-time reefer container management system to effectively control all reefer containers widely being used across the world.

A Development Of Low Power PLC Modem for Monitoring of Power Consumption and Breaking of Abnormal Power (전력감시 및 이상전력 차단 기능을 갖는 저전력 전력선통신 모뎀 개발)

  • Yoon, Jae-Shik;Wee, Jung-Chul;Song, Yong-Jae;Park, Chung-Ha;Kim, Jae-Heon
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1964_1965
    • /
    • 2009
  • 최근 경제성장과 함께 생활수준의 향상으로 인하여 홈 게이트웨이는 디지털 홈 가전기기에 초고속 통신망 접속 기능을 제공하며 각종 기기들을 하나로 네트워크화 하는 중요한 기능을 담당하게 된다. 전력선 통신은 전력선을 매체로 하기 때문에 신규선로의 포설 없이 가전기기 및 정보화 서비스 모뎀들의 네트워크화에 용이할 뿐만 아니라 커버리지 확장에도 뛰어나서 디지털 가전, 원격검침, 전력설비 감시제어, 국가 재난 감시 시스템 등의 기본 통신 방식으로 가장 유력한 기술로써 디지털 가전을 포함한 유비쿼터스 전기설비 네트워크 구성에서 필수적 기술로 채택되고 있기 때문에 지능형 홈 네트워크, 전력IT 부가 서비스, 설비감시 네트워크, 유비쿼터스 네트워크 관련 기술에 대한 파급 효과가 매우 크며, 디지털 가전의 기본 통신 방식으로 가장 유력한 기술로써 디지털 가전 구성에서 필수적 기술로 채택되고 있다. 본 연구에서는 전력선통신모뎀을 이용하여 가전기기의 전력 소비를 감지할 수 있는 센서를 내장한 전력선 통신기반의 전력 감시 모듈을 개발하여 실시간 원격 모니터링을 통해 소비전력 패턴을 작성한다. 그리고 전력감시 모듈에 연결된 가전기기의 소비전력 패턴 분석을 통해 전력소비 이상 유무를 감지할 수 있는 알고리즘을 개발, 탑재하여 이상 유무를 판단하고 전력소비가 급증할 시 자동으로 전력을 차단하여 화재나 누전의 위험을 방지한다. 이에 본 연구는 전력감시 및 이상전력 차단기능을 갖는 저전력 전력선통신 모뎀 개발에 관한 것이다.

  • PDF

Development of a Remote Dust Collector Bag Control System using Power Line Communication (전력선 통신을 이용한 원격 집진기 bag 제어 시스템 개발)

  • Kim, Jung-Sook
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.4
    • /
    • pp.91-98
    • /
    • 2010
  • Advances in communications and control technology, the strengthening of the Internet, and the growing recognition of the urgency to reduce the risk and production cost are motivating the development of improvements in the traditional manufacturing industry. In this paper, we developed a remote dust collector bag control system which is a combination of advanced IT and traditional dust collector based on the event. At first, we made the A/D(Analog/Digital) converter using a micro processor because the differential pressure transmission, which is a sensor of the dust collector, produces analog volt data. A/D converter can provide RS-232 communication to connect with Power Line Communication(PLC) modem. And, n-bytes message format was defined for the efficient dust collector bag information transmission from a dust collector to a user. Also, we designed the data types to model the dust collector and the dust collector bag, and they were logically modeled using XML and object-oriented modeling method. In addition to that, we implemented the system for showing the dust collector bag exchange time exactly to users at real-time using various visual user interfaces.