• 제목/요약/키워드: PLC (Power line communication)

검색결과 278건 처리시간 0.028초

Design and Implementation of the Basic Technology for Solitary Senior Citizen's Lonely Death Monitor ing System using PLC

  • Huh, Jun-Ho;Seo, Kyungryong
    • 한국멀티미디어학회논문지
    • /
    • 제18권6호
    • /
    • pp.742-752
    • /
    • 2015
  • The communications through the power lines are called as the PLC and this is a common name for the communication modes for the information delivery. This technology transmits the data through the power lines on which the information is stored with the form of high frequency signal. The characteristic of the frequency signal is that the signal can be separated from the power line through exclusive power line modem and transmitted to the terminal devices. In this paper, 'In-home Headcount' checking algorithm using Wi-Fi and taking above mentioned advantages is proposed, and the basic Technology for such Solitary Senior Citizen's Lonely Death monitoring system has been designed and implemented. The comparative analysis has been conducted in this paper with the test-operated and test bed-completed 'Hyosimi 119 Safety-Welfare System' which is still being tested since 2008. With the 'In-home Headcount Checking Algorithm', Wi-Fi connection/disconnection status and SSIDs of relevant Wi-Fis will be checked. We expect that our proposed method will become as the basic Technology which can prevent lonely deaths of elderly people living alone. Since the PLC technology can be normally implement all the functions used on internet anticipate that the technology could be applied to many areas to construct a new form of communication network.

듀얼 모드형 고신뢰 PLC 모뎀 칩 설계 및 구현 (Design and Implementation of the Dual-Mode Type Reliable PLC Modem Chip)

  • 이원태;최성수;윤성하;이영철
    • 전기학회논문지
    • /
    • 제57권3호
    • /
    • pp.488-493
    • /
    • 2008
  • This paper represents a dual-mode type transmission technique for a high reliable narrow-band power line communication(PLC) modem, and its design and implementation of a system-on-chip(SoC). The proposed transmission technique is based on a Chirp modulation for the purpose of overcoming time variations of power line channel environments in the narrow-bandwidth of the frequency range of 95-145.5 kHz. The designed modem is fabricated utilizing a mixed 0.18 ${\mu}m$ CMOS technology. Especially, according to the power line channel environments the data transmission rate can be selectively changed into 2.5 kbps and 480 bps. The total hardware complexity of the implemented chip is about 50,000 gates, the power consumption is about 26mW, and the operating frequency is up to 5.12 MHz.

전력선통신 기반 영상 송수신시스템 설계 및 구현 (Design and Implementation of Image Communication System Based on Power Line Communication)

  • 장락주;이순이;강석원
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2010년도 춘계 종합학술대회 논문집
    • /
    • pp.31-33
    • /
    • 2010
  • 본 논문에서는 전력선통신(Power Line Communication : PLC)을 이용하여 고열, 고압등 매우 열악한 작업 환경에서 작업자의 상황을 실시간 관리 할 수 있는 영상 송수신시스템을 설계 및 구현하였다. 시스템 설계의 중점 고려사항으로 단순화 구조의 적용, 설치 및 이동의 용이성 뿐만 아니라 고열이나 고압 등을 충분히 견딜 수 있고 다양한 노이즈 환경에서도 깨끗한 영상을 전송 할 수 있는 측면에 역점을 두었다.

  • PDF

Performance of a Multi-Code CDMA Scheme on Non-Gaussian Noises in Power Line Communication Channels

  • Na, Sung-Ju;Yoan Shin
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 ITC-CSCC -1
    • /
    • pp.132-135
    • /
    • 2000
  • In this paper, we propose to exploit a multi-code CDMA scheme for power line communication (PLC) systems, and its performance on non-Gaussian impulse and harmonic noises is presented. The proposed multi-code CDMA scheme utilizes convolutional coding and block interleaving to combat with the non-Gaussian noises, and simulation results indicate effective alleviation of these noises, and thus significant bit error rate improvement by the proposed scheme even under strict restriction of frequency band allowed in PLC systems.

  • PDF

전력선통신을 이용한 납축전지용 Battery Management System의 설계 및 구현

  • 장태욱;이현우
    • 정보와 통신
    • /
    • 제33권7호
    • /
    • pp.53-58
    • /
    • 2016
  • 본 논문에서는 전력선(Power Line Communication, 이하 PLC)통신을 이용하여, 납축배터리의 효율적인 충방전 관리 및 배터리 수명의 지표로 쓰일 수 있는 내부저항 측정 방법에 대하여 알아본다. 또한 이러한 시스템에 대한 임베디드 플랫폼을 설계하고, 실제 UPS환경과 연동시 고려해야 할 사항에 대하여 알아본 후, 이를 해결 할 수 있는 방안을 제시한다.

A Signal Anti-reduction System for Power Line Communication

  • Ko Jong-Sun;Kim Hyun-Sik;Hong Soon-Chan
    • Journal of Power Electronics
    • /
    • 제4권4호
    • /
    • pp.256-260
    • /
    • 2004
  • A new communication system is suggested using a single-phase full-bridge inverter with high efficiency ferrite core for power line communication (PLC). The conventional system has a decreasing signal voltage problem due to internal resistance. The proposed system has almost zero internal impedance and replaces a linear amplifier.

P2HYMN: 발전소 정비지원 하이브리드 네트워크 시스템 (P2HYMN: Hybrid Network Systems for Maintenance Support in Power Plants)

  • 진영훈;추영열
    • 제어로봇시스템학회논문지
    • /
    • 제20권7호
    • /
    • pp.782-787
    • /
    • 2014
  • Due to the complicated steel structure and safety concern, it is very difficult to deploy wireless networks in power plants. This paper presents a hybrid network, named as $P^2HYMN$ (Power Plant HYbrid Maintenance Network), encompassing PLC (Power Line Communication), TLC (Telephone Line Communication), and Wireless LAN. The design goal of $P^2HYMN$ is to integrate multimedia data such as design drawings of control equipment, process data, and video image data for maintenance operation in electric power plants. A Multiplex Line Communication (MLC) device was designed and implemented to integrate PLC, TLC, and Wireless LAN into $P^2HYMN$. Performance test of $P^2HYMN$ has been conducted on a testbed under various conditions. The throughput of TLC was shown as 39 Mbps. Because the bandwidth requirement per camera is 8.5 Mbps on average, TLC is expected to support more thant four video camera at the same time.

제어용 PLC 모뎀을 위한 대기전력 절감 모듈 개발 (A Development of Module Operating on Standby-power Reduction for PLC Control Modem)

  • 김기현;김지홍;김남균;김상철;서길수;김은동
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.296-299
    • /
    • 2004
  • This paper introduces a supplementary module reducing tile standby-power of Power Line Communication(PLC) modem, one of the network equipments that take up much of tile stand-by power. This supplementary module consists of three parts, such as a compare part, a control part, and a switch part. This supplementary module controls the power going from the power supply element into PLC modem, which brings about the effect of standby-power reduction. It is assured that over 30% standby-power reduction is estimated when we applied this module to a low-speedy PLC control modem.

  • PDF

전력선 통신 시스템을 위한 신호 감쇠 저하 장치 연구 (A Study on the Signal Anti-reduction Equipment in Power Line Communication)

  • 김주환
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.103-106
    • /
    • 2000
  • In this paper a communication system that is not using the communication line but power line is presented. It will be very useful for an information-oriented society with tele-metering and home automation. Conventional system has a difficulty in transmitting information due to decreasing communication voltage and increasing carrier, current. Proposed idea is a special type switching amplifier system which has a low inner resistance. It can provide reactive power and dose not have low impedance between the transceivers. This new system is proposed to overcome the loss of conductor load in a PLC system.

  • PDF

고압 배전선로를 이용한 고속 전력선 통신 가입자망 구축 연구 (Field Trial of Power Line Communication Access Network over Medium Voltage Power Distribution Grid)

  • 이재조;오휘명;박영진;김관호;이대영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 D
    • /
    • pp.3040-3042
    • /
    • 2005
  • During the last several years, interest in broad-band power line communications (PLC) has been grown over medium voltage(MV) power distribution lines as well as low voltage lines. This paper introduces a medium voltage PLC test field that is set up in the suburbs of Euiwang city in Korea. This test field could be used not only for the measurement of communication channel environment but also for internet service. This paper shows the configuration of medium voltage test field with network devices like MV signal coupler and the results of channel environment like noise and impulse response. It also shows the service performance of PLC access network through network management system.

  • PDF