• 제목/요약/키워드: PLASMA SURFACE TREATMENT

검색결과 989건 처리시간 0.028초

Nd : YAG LASER 조사가 치과 임플란트의 물성과 온도 상승에 미치는 영향 (EFFECT OF ND : YAG LASING ON TEMPERATURE RISING AND PROPERTIES OF MATTER OF DENTAL IMPLANTS)

  • 이호용
    • 대한치과보철학회지
    • /
    • 제34권3호
    • /
    • pp.489-500
    • /
    • 1996
  • Pulsed Nd : YAG LASER has been applied to various fields in clinical dentistry including the treatment of peri-implantitis. However, LASER can affect properties of matter of dental implants which are important to maintaining the health of peri-implant tissue and can raise its temperature during lasing. So there have been warings of using LASER to treat peri-implantitis. But, the effects of laser on dental implants itself are not certain yet. So we measured the temperature rising, examined matter of properties by SEM and EDX before and after pulsed Nd : YAG lasing various intensity. 7 TPS implants and 7 HPS implants were used and pulsed Nd : YAG LASER was used in 0.3W, 1.0W, and 2.0W. 1. 2.0W LASER made polished neck portion of HPS implants reach $39.2^{\circ}C$ after 5 seconds lasing. 2. LASER made crater-like defects on plasma sprayed surface and surfaces were melted and divided by fragments after lasing. 3. There was no specific evidence of element change after lasing.

  • PDF

대기압 플라즈마 처리에 의한 PMMA의 표면개질 특성 (Surface Characteristics of PMMA by Atmospheric Pressure Plasma Treatment)

  • 이창호;전병준;이재복;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.313-316
    • /
    • 2009
  • 본 연구에서는 대기압 플라즈마의 처리 조건에 따른 폴리프로필렌(PMMA)의 접착력 향상을 위한 접촉각 및 표면에너지의 변화를 관찰하였다. 대기압 플라즈마의 처리 변수로는 처리 속도, 방전 전력, 시료와 플라즈마 헤드 사이의 방전 갭이며, 측정된 접촉각을 이용하여 표면에너지 변화를 계산한 후 접촉각 및 표면에너지의 변화를 분석하였다. 그 결과는 방전전력이 증가할수록 접촉각은 낮아지고 표면에너지는 증가하였으며, 시료와 플라즈마 헤드 사이의 방전 간격은 3[mm]에서 접촉각이 낮고 표면에너지가 높게 나타나 PMMA의 접착력 향상을 위한 친수성 물질로 표면 개질됨을 확인할 수 있었다.

  • PDF

유전체 장벽 방전내에서 오존발생 특성 (Ozone Generation Characteristics in Dielectric Barrier Discharge)

  • 이형호;조국희;김영배;서길수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권12호
    • /
    • pp.673-678
    • /
    • 2000
  • The dielectric barrier discharge(DBD) is a common method to create a nonthermal plasma in which electrical energy is used to create electrons with a high average kinetic energy. The unique aspect of dielectric barrier discharges is the large array of short lifetime(10ns) silent discharges created over the surface of the dielectric. A silent discharge is generated when the applied voltage exceeds the breakdown voltage of the carrier gas creating a conduction path between the applied electrode and grounded electrode. As charge accumulates on the dielectric, the electric field is reduced below the breakdown field of the carrier gas and the silent discharge self terminates preventing the DBD cell from producing a thermal arc. In fact, the most significant application of dielectric barrier discharges is to generate ozone for contaminated water treatment. Therefore, experiments were perfomed at 1∼2[bar] pressure using a coaxial geometry single dielectric barrier discharge for ozone concentrations and energy densities. The main result show that the concentration and efficiency of ozone are influenced by gas nature, gas quantity, gas pressure, supplied voltage and frequency.

  • PDF

나노입자를 첨가한 전극용 무연 silver 페이스트의 제조 (Preparation of Lead-free Silver Paste with Nanoparticles for Electrode)

  • 박성현;박근주;장우양;이종국
    • 열처리공학회지
    • /
    • 제19권4호
    • /
    • pp.219-224
    • /
    • 2006
  • Silver paste with low sintered temperature has been developed in order to apply electronic parts, such as bus electrode, address electrode in PDP (Plasma Display Panel) with large screen area. In this study, nano-sized silver particles with 10-30 nm were synthesized from silver nitrate ($AgNO_3$) solution by chemical reduction method and silver paste with low sintered temperature was prepared by mixing silver nanoparticles, conventional silver powder with the particle size 1.6 um and Pb-free frit. Conductive thick film from silver paste was fabricated by screen printing on alumina substrate. After firing at $540^{\circ}C$, the cross section and surface morphology of the thick films were analyzed by FE-SEM. Also, the sheet resistivity of the fired thick films was measured using the four-point technique.

Hydrogenated Amorphous Silicon Thin Films as Passivation Layers Deposited by Microwave Remote-PECVD for Heterojunction Solar Cells

  • Jeon, Min-Sung;Kamisako, Koichi
    • Transactions on Electrical and Electronic Materials
    • /
    • 제10권3호
    • /
    • pp.75-79
    • /
    • 2009
  • An intrinsic silicon thin film passivation layer is deposited by the microwave remote-plasma enhanced chemical vapor deposition at temperature of $175^{\circ}C$ and various gas ratios for solar cell applications. The good quality amorphous silicon films were formed at silane $(SiH_4)$ gas flow rates above 15 seem. The highest effective carrier lifetime was obtained at the $SiH_4$, flow rate of 20 seem and the value was about 3 times higher compared with the bulk lifetime of 5.6 ${\mu}s$ at a fixed injection level of ${\Delta}n\;=\;5{\times}10^{14}\;cm^{-3}$. An annealing treatment was performed and the carrier life times were increased approximately 5 times compared with the bulk lifetime. The optimal annealing temperature and time were obtained at 250 $^{\circ}C$ and 60 sec respectively. This indicates that the combination of the deposition of an amorphous thin film at a low temperature and the annealing treatment contributes to the excellent surface and bulk passivation.

WETTABILITY AND DRUG DELIVERY OF FUNCTIONALLY GRADED NANO-MICRO POROUS TITANIUM SURFACE

  • Yun, Kwi-Dug;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Park, Ha-Ok;Lim, Hyun-Pil
    • 대한치과보철학회지
    • /
    • 제46권3호
    • /
    • pp.307-319
    • /
    • 2008
  • STATEMENT OF PROBLEM: It is known that an anodic oxidation technique, one of the methods for the implant surface treatment, remarkably increased surface area, enhanced wettability and accelerated the initial bone healing. Purpose: This study was performed to evaluate the wettability of anodized titanium surface which has a nanotubular structure, to assess osseointegration after the placement of implant with nano-size tubes on tibia of rats and to analyze quantitatively transferable rhBMP-2 on each surface. MATERIAL AND METHOD: Four different kinds of surface-treated titanium discs (polished (machined surface) group, micro (blasting surface) group, nano (anodizedmachined surface) group, and nano-micro (anodized-blasting surface) group) were fabricated (n=10). Three different media were chosen to measure the surface contact angles; distilled water, plasma and rhBMP-2 solution. After a single drop (0.025 $m{\ell}$) of solution, the picture was taken with the image camera, and contact angle was measured by using image analysis system. For the test of osseointegration, 2 kinds of anodized surface (anodized-machined surface, anodized-blasting surface) implants having 2.0 mm in diameter and 5.0 mm in length inserted into the tibia of Wistar rats. After 3 weeks, tibia were harvested and the specimens were stained with hematoxylin and eosin for histological analysis. To test the possibility of drug delivery, after soaking sample groups in the concentration of 250 ng/$m{\ell}$l of rhBMP-2 for 48 hours, the excess solution of rhBMP-2 were removed. After that, they were lyophilized for 24 hours, and then the rhBMP-2 on the surface of titanium was resolved for 72 hours in PBS. All the extracted solution was analyzed by ELISA. One-way analysis of variance (ANOVA) was performed on the data. RESULTS: The wettability is improved by anodic oxidation. The best wettability was shown on the nano-micro group, and it was followed by nano group, micro group, and polished group. In the histological findings, all implants showed good healing and the new bone formation were observed along the implant surface. After 3 days, nano-micro group delivered the most amount of rhBMP-2, followed by nano group, micro group, and polished group. CONCLUSION: It indicated that anodic oxidation on blasting surface produce functionally graded nano-micro porous structure and enhance hydrophilicity of the surface and osseointegration. The findings suggest that the nano-micro porous structure could be a useful carrier of osteogenic molecules like rhBMP-2.

흰쥐의 스트레스성 위궤양에 대한 Alove vera의 항궤양작용 (The Antiulcer Effects of Alove vera on the Stomach ulcer Induced by Stress in rats)

  • 박은지;이용욱
    • 한국식품위생안전성학회지
    • /
    • 제9권3호
    • /
    • pp.175-184
    • /
    • 1994
  • This was performed to investigate the antiulcer effects of Aloe vera on the stomach ulcer induced by restraint and water-immersion stress in rats. For this experiment, 60 male Sprague-Dawley strain were used. The experimental groups were divided into five: a control(CA) and 4 aloe treatment groups. Each dose of aloe was 50 mg/kg BW(AA), 100mg/kg BW(AB), 200 mg/kg BW(AC), and 400 mg/kg BW(AD). The rats were allocated to each group by 12 and observed for 4 weeks. The results are as following. 1. The stomach surface pH in each group showed no significant difference, byt the values of aloe treatment groups were higher than the value of the control group. 2. The gastric wall mucus was significantly increased in all aloe treatment groups(p<0.05) compared with the control group. Especially in AC and AD group the differences were higher(p<0.01). 3. At shear rate rate 11.25, 45.0, 90.0, 225.0 sec-1, whole blood viscosity and plasma viscosity were measured. Most of the values of aloe treatment groups were significantly low compared with those of the control group(P<0.05). 4. The ulcer index of aloe treatment groups were significantly low campared with control group(p<0.05). Especially in AC and AD group the differences were more significant(p<0.01). 5. Less severe ulcers were observed in AA and AB group than in the control group. Tissues of AC and AD group had only slight ulcers and necrosis of tissue was not observed in these groups. Especially in AD group, there was more mucus than other groups and it seemed that alove vera stimulated the epithelial regeneration. From the results of this study, it can be concluded that the oral administration of Alove vera results in protection of stomach ulcer by stimulating the secretion of gastric mucus and the circulation of blood.

  • PDF

질화탄소 표면층 및 열처리가 탄소 나노튜브 미세팁의 전계방출 및 장시간 안정성에 미치는 영향 (Effects of Carbon Nitride Surface Layers and Thermal Treatment on Field-Emission and Long-Term Stability of Carbon Nanotube Micro-Tips)

  • 노영록;김종필;박진석
    • 반도체디스플레이기술학회지
    • /
    • 제9권1호
    • /
    • pp.41-47
    • /
    • 2010
  • The effects of thermal treatment on CNTs, which were coated with a-$CN_x$ thin film, were investigated and related to variations of chemical bonding and morphologies of CNTs and also properties of field emission induced by thermal treatment. CNTs were directly grown on nano-sized conical-type tungsten tips via the inductively coupled plasma-chemical vapor deposition (ICP-CVD) system, and a-$CN_x$ films were coated on the CNTs using an RF magnetron sputtering system. Thermal treatment on a-$CN_x$ coated CNT-emitters was performed using a rapid thermal annealing (RTA) system by varying temperature ($300-700^{\circ}C$). Morphologies and microstructures of a-$CN_x$/CNTs hetero-structured emitters were analyzed by FESEM and HRTEM. Chemical composition and atomic bonding structures were analyzed by EDX, Raman spectroscopy, and XPS. The field emission properties of the a-$CN_x$/CNTs hetero-structured emitters were measured using a high vacuum (below $10^{-7}$ Torr) field-emission measurement system. For characterization of emission stability, the fluctuation and degradation of the emission current were monitored in terms of operation time. The results were compared with a-$CN_x$ coated CNT-emitters that were not thermally heated as well as with the conventional non-coated CNT-emitters.

초임계이산화탄소를 이용한 플라즈마 손상된 다공성 저유전 막질의 복원 (Repair of Plasma Damaged Low-k Film in Supercritical Carbon Dioxide)

  • 정재목;임권택
    • 청정기술
    • /
    • 제16권3호
    • /
    • pp.191-197
    • /
    • 2010
  • 초임계이산화탄소에서 실릴화제를 사용하여 반응시간, 압력, 온도를 변화하며 플라스마에 의해 손상된 다공성 p-SiOCH 필름의 실릴화 보수반응을 진행하였다. FT-IR 분석 결과 $3150{\sim}3560cm^{-1}$ 영역의 $SiOH/H_2O$ 특성밴드의 감소는 다소 확인할 수 있었지만, 메틸화 peak의 변화치는 관찰하기 어려웠다. 그러나 실릴화에 따른 표면 소수성은 빠른 반응시간 내에 복원되었다. 내부 복원반응을 효과적으로 유도하기 위하여 열 전처리 공정을 상압 또는 진공 조건에서 진행하였으며, 전처리에 따라 표면 접촉각이 약간 상승하였고, 뒤이은 초임계 실릴화반응으로 표면 소수성이 완전히 복원되는 것을 관찰하였다. 플라스마 손상과정에서 표면 내부 메틸기의 감소가 나타나지만 실릴화 보수반응에 따라 메틸기의 복원은 눈에 띄게 나타나지 않음을 FT-IR, spectroscopic ellipsometry 와 secondary ion mass spectroscopy의 분석결과를 통하여 확인하였다. 막질에 대한 Ti 증착 후 glow discharge spectrometry로 내부 Ti 원소를 분석한 결과, 초임계 실릴화반응을 통하여 손상된 p-SiOCH막질의 열린 기공의 봉인효과가 나타나는 것을 확인하였다.

나노임프린트 공정에서 실란커플링제 기상증착을 이용한 표면처리 효과 (The Surface Treatment Effect for Nanoimprint Lithography using Vapor Deposition of Silane Coupling Agent)

  • 이동일;김기돈;정준호;이응숙;최대근
    • Korean Chemical Engineering Research
    • /
    • 제45권2호
    • /
    • pp.149-154
    • /
    • 2007
  • 나노임프린트 공정기술은 나노구조물이 패턴된 스템프(혹은 몰드)를 이용하여 적절한 기판 위에 나노구조물을 복제하여 패턴을 전사하는 기술이다. 효과적인 나노임프린트 공정을 위해서는 몰드의 이형처리뿐 아니라 반대쪽의 기질과 레지스트 사이에 접착력 증가(adhesion promoter) 처리가 매우 중요한 역할을 한다. 본 연구에서는 자기조립 실란커플링제의 기상증착을 이용하여 나노임프린트 공정에서 사용되는 접착 증가막 및 표면처리 방법을 비교 분석 하였다. 이를 위해서 평탄화층(DUV-30J), 산소 플라즈마 처리, 실란커플링제 자기조립막이 비교되었다. 실란커플링제 자기조립막이 형성된 실리콘 표면은 전체적으로 나노 두께의 균일한 막이 형성되며 임프린트시 구조물들을 정밀하게 전사하였으며 3-acryloxypropyl methyl dichlorosilane(APMDS)을 이용한 자기조립막(SAMs) 처리가 평탄화층과 산소 플라즈마 처리보다 강한 접착력을 가지고 있어 나노임프린트 공정에 적합함을 알 수 있었다.